Overview of Fluid Dynamics Activities at the Marshall Space Flight Center

Since its inception 40 years ago, Marshall Space Flight Center (MSFC) has had the need to maintain and advance state-of-the-art flow analysis and cold-flow testing capability to support its roles and missions. This overview discusses the recent organizational changes that have occurred at MSFC with emphasis on the resulting three groups that form the core of fluid dynamics expertise at MSFC: the Fluid Physics and Dynamics Group, the Applied Fluid Dynamics Analysis Group, and the Experimental Fluid Dynamics Group. Recently completed activities discussed include the analysis and flow testing in support of the Fastrac engine design, the X-33 vehicle design, and the X34 propulsion system design. Ongoing activities include support of the RLV vehicle design, Liquid Fly Back Booster aerodynamic configuration definition, and RLV focused technologies development. Other ongoing activities discussed are efforts sponsored by the Center Director's Discretionary Fund (CDDF) to develop an advanced incompressible flow code and to develop optimization techniques. Recently initiated programs and their anticipated required fluid dynamics support are discussed. Based on recent experiences and on the anticipated program needs, required analytical and experimental technique improvements are presented. Due to anticipated budgetary constraints, there is a strong need to leverage activities and to pursue teaming arrangements in order to advance the state-of-the-art and to adequately support concept development. Throughout this overview there is discussion of the lessons learned and of the capabilities demonstrated and established in support of the hardware development programs.

Garcia, Roberto↗

Probabilistic and Other Neural Nets in Multi-Hole Probe Calibration and Flow Angularity Pattern Recognition

The use of probabilistic (PNN) and multilayer feed forward (MLFNN) neural networks are investigated for calibration of multi-hole pressure probes and the prediction of associated flow angularity patterns in test flow fields. Both types of networks are studied in detail for their calibration and prediction characteristics. The current formalism can be applied to any multi-hole probe, however the test results for the most commonly used five-hole Cone and Prism probe types alone are reported in this article.

Baskaran, Subbiah↗

Flow properties in expansion tube with helium, argon, air, and CO2

Test flow velocities from 5 to 7 km/sec were generated in a 6-in. expansion tube using helium, argon, air, and CO2 test gases. Pitot pressure profiles across the flow at the test section are presented for the four test gases, and measured flow quantities are compared to computer predicted values. Comparison of predicted and measured flow quantities suggests the expansion to be near thermochemical equilibrium for all test gases and implies the existence of a totally reflected shock at the secondary diaphragm. Argon, air, and CO2 flows were observed to attenuate while traversing the acceleration section, whereas no attenuation was observed for helium.

Miller, C. G.↗

Experimental study of flow distribution with circumferential manifolds

Water flow test results on fluid flow distribution and pressure loss in curved manifolds with tangential or radial entry are reported. Manifolds were studied both as inlet and outlet manifolds. Manifolds can be used for boilers and/or heat exchangers for advanced space electric power plants.

Dittrich, R. T.↗

Development of the technology for the fabrication of reliable laminar from control panels

Materials were assessed and fabrication techniques were developed for use in the manufacture of wing surface materials compatible with the application of both aluminum alloys and nonmetallic composites. The concepts investigated included perforations and slots in the metallic test panels and microporosity and perforations in the composite test panels. Perforations were produced in the metallic test panels by the electron beam process and slots were developed by controlled gaps between the metal sheets. Microporosity was produced in the composite test panels by the resin bleed process, and perforations were produced by the fugitive fiber technique. Each of these concepts was fabricated into test panels, and air flow tests were conducted on the panels.

Meade, L. E.↗

The NASA Lewis Research Center Internal Fluid Mechanics Facility

An experimental facility specifically designed to investigate internal fluid duct flows is described. It is built in a modular fashion so that a variety of internal flow test hardware can be installed in the facility with minimal facility reconfiguration. The facility and test hardware interfaces are discussed along with design constraints of future test hardware. The plenum flow conditioning approach is also detailed. Available instrumentation and data acquisition capabilities are discussed. The incoming flow quality was documented over the current facility operating range. The incoming flow produces well behaved turbulent boundary layers with a uniform core. For the calibration duct used, the boundary layers approached 10 percent of the duct radius. Freestream turbulence levels at the various operating conditions varied from 0.64 to 0.69 percent of the average freestream velocity.

Porro, A. R.↗

Oscillating-flow regenerator test rig: Woven screen and metal felt results

We present correlating expressions, in terms of Reynolds or Peclet numbers, for friction factors, Nusselt numbers, enhanced axial conduction ratios, and overall heat flux ratios in four porous regenerator samples representative of stirling cycle regenerators: two woven screen samples and two random wire samples. Error estimates and comparison of data with others suggest our correlations are reliable, but we need to test more samples over a range of porosities before our results will become generally useful.

Gedeon, D.↗

A computational investigation of fuel mixing in a hypersonic scramjet

A parabolized, Navier-Stokes code, SHIP3D, is used to numerically investigate the mixing between air injection and hydrogen injection from a swept ramp injector configuration into either a mainstream low-enthalpy flow or a hypervelocity test flow. The mixing comparisons between air and hydrogen injection reveal the importance of matching injectant-to-mainstream mass flow ratios. In flows with the same injectant-to-mainstream dynamic pressure ratio, the mixing definition was altered for the air injection cases. Comparisons of the computed results indicate that the air injection cases overestimate the mixing performance associated with hydrogen injection simulation. A lifting length parameter, to account for the time a fluid particle transverses through the mixing region, is defined and used to establish a connection of injectant mixing in hypervelocity flows, based on nonreactive, low-enthalpy flows.

Fathauer, Brett W.↗

Oscillating-flow regenerator test rig

This report summarizes work performed in setting up and performing tests on a regenerator test rig. An earlier status report presented test results, together with heat transfer correlations, for four regenerator samples (two woven screen samples and two felt metal samples). Lessons learned from this testing led to improvements to the experimental setup, mainly instrumentation as well as to the test procedure. Given funding and time constraints for this project it was decided to complete as much testing as possible while the rig was set up and operational, and to forego final data reduction and analysis until later. Additional testing was performed on several of the previously tested samples as well an on five newly fabricated samples. The following report is a summary of the work performed at OU, with many of the final test results included in raw data form.

Wood, J. G.↗

Aeroacoustic Characteristics of Model Jet Test Facility Flow Conditioners

An experimental investigation of flow conditioning devices used to suppress internal rig noise in high speed, high temperature experimental jet facilities is discussed. The aerodynamic and acoustic characteristics of a number of devices including pressure loss and extraneous noise generation are measured. Both aerodynamic and acoustic characteristics are strongly dependent on the porosity of the flow conditioner and the closure ratio of the duct system. For unchoked flow conditioners, the pressure loss follows conventional incompressible flow models. However, for choked flow conditioners, a compressible flow model where the duct and flow conditioner system is modeled as a convergent-divergent nozzle can be used to estimate pressure loss. Choked flow conditioners generate significantly more noise than unchoked conditioners. In addition, flow conditioners with small hole diameters or sintered metal felt material generate less self-noise noise compared to flow conditioners with larger holes.

Kinzie, Kevin W.↗

Madidrop for Passive Silver Dosing

Madidrop is a rectangular ceramic tablet originally designed to dose a 10-20-liter volume of water with silver to act as a biocide for remote communities with unreliable water sources. Silver as a biocide is a proposed method to control bacteria on the International Space Station or future Artemis missions. This would replace iodine currently used due to issues with a dual biocide system in place between Russian and US segments and the extra cost of iodine removal required before consumption. NASA has been reviewing this Madidrop technology and its potential application with a water reclamation system on orbit to dose silver after purifying the water. While there are a couple alternative methods to dosing silver on station, this method is like the existing passive dosing method used currently to dose iodine. Tests conducted characterize the manufacturer’s original intent to leave the tablet in a tank for a specified amount of time before removing and testing alternative passive flow-through methods. Passive flow testing involved two options: keeping the tablet intact or crushing the tablet into smaller particle sizes to increase the surface area while varying particle sizes. The results of these tests revealed a large amount of silver output at first that quickly reduced to a constant lower output within a reasonable dosing concentration range. The initial high concentration peaks after a couple days of quiescence and could be useful for shocking the initial tank water contents. Madidrop used as a passive particle doser could act as a stand-in replacement for iodine in future spaceflight water reclamation systems.

Ryan Ogilvie↗

Madidrop for Passive Silver Dosing

Madidrop is a rectangular ceramic tablet originally designed to dose a 10-20-liter volume of water with silver to act as a biocide for remote communities with unreliable water sources. Silver as a biocide is a proposed method to control bacteria on the International Space Station or future Artemis missions. This would replace iodine currently used due to issues with a dual biocide system in place between Russian and US segments and the extra cost of iodine removal required before consumption. NASA has been reviewing this Madidrop technology and its potential application with a water reclamation system on orbit to dose silver after purifying the water. While there are a couple alternative methods to dosing silver on station, this method is like the existing passive dosing method used currently to dose iodine. Tests conducted characterize the manufacturer’s original intent to leave the tablet in a tank for a specified amount of time before removing and testing alternative passive flow-through methods. Passive flow testing involved two options: keeping the tablet intact or crushing the tablet into smaller particle sizes to increase the surface area while varying particle sizes. The results of these tests revealed a large amount of silver output at first that quickly reduced to a constant lower output within a reasonable dosing concentration range. The initial high concentration peaks after a couple days of quiescence and could be useful for shocking the initial tank water contents. Madidrop used as a passive particle doser could act as a stand-in replacement for iodine in future spaceflight water reclamation systems.

Ryan Ogilvie↗

Numerical simulation of transient hypervelocity flow in an expansion tube

Several numerical simulations of the transient flow of helium in an expansion tube are presented in an effort to identify some of the basic mechanisms which cause the noisy test flows seen in experiments. The calculations were performed with an axisymmetric Navier-Stokes code based on a finite volume formulation and upwinding techniques. Although laminar flow and ideal bursting of the diaphragms was assumed, the simulations showed some of the important features seen in experiments. In particular, the discontinuity in tube diameter of the primary diaphragm station introduced a transverse perturbation to the expanding driver gas and this perturbation was seen to propagate into the test gas under some flow conditions. The disturbances seen in the test flow can be characterized as either small amplitude, low frequency noise possibly introduced during shock compression or large amplitude, high frequency noise associated with the passage of the reflected head of the unsteady expansion.

Jacobs, P. A.↗

CFD Validation with LDV Test Data for Payload/Fairing Internal Flow

Flowfield testing of a 1/5th scale model of a payload/fairing configuration, typical of an expendable launch vehicle, has been performed. Two-dimensional (planar) velocity measurements were carried out in four planes with the aid of Laser Doppler Velocimetry (LDV). Computational Fluid Dynamics (CFD) analysis results for the scale model flowfleld are compared with the test data. The CFD results are in general agreement with the test data. The ability of the CFD methodology in identifying the global flow features (including critical points such as vortex, saddle point, etc.) has been demonstrated. Practical problems and difficulties associated with the LDV method applied to the complex geometry under consideration have been summarized.

Kandula, max↗