Search NASA⌕ Search

SEARCH · Search NASA

Results for “flow test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Flow field design for zero-gap microbial electrolysis cells using synthetic and real wastewater

Increasing performance in microbial electrolysis cells (MECs) requires the development of optimized reactor configurations with minimal internal resistance and capable to operate with real wastewater. Here, the impact of two different flow fields (serpentine and circular) was examined in zero-gap MECs with synthetic and real wastewaters. The serpentine flow field enabled a uniform distribution of the electrolyte in the anode chamber, resulting in larger current densities at lower flow rates compared to the circular flow field. Electrochemical tests using synthetic media with high buffer capacity revealed more stable and higher performance with the serpentine flow field compared to the circular flow path, producing larger current density (23.7 ± 0.8 A/m 2 vs 21.9 ± 5.6 A/m 2 ), hydrogen production rate (75.8 ± 4.1 L/L-d vs 54.3 ± 2.4 L/L-d), cathodic coulombic efficiency (>91 % vs >50 %), and an overall lower internal resistance (12.5 ± 0.5 mΩm 2 vs 14.8 ± 3.7 mΩm 2 ). Continuous operation for over 30 days with real wastewater indicated higher tolerance of the MECs with serpentine flow field toward media with large concentration of suspended solids, producing a current density of 5.4 ± 1.1 A/m 2 and a hydrogen production rate of 22.2 ± 6.2 L/L-d. Furthermore, the results presented here underscore the importance of reactor design and architecture in optimizing MEC performance for hydrogen production from liquid wastes.

flow path↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing, determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rates along with the average and maximum qualified stack flow rates for each of the LAB facility stacks. For each stack, the operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10°, except for the LB-C2 Fan A results, which were an average of 13.7°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 4.1% COV, which were all within the range of the target percent coefficient of variation values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental and Computational Characterization of a Modified Sioutas Cascade Impactor for Respirable Radioactive Aerosols

Oak Ridge National Laboratory is collecting and characterizing aerosols released when spent nuclear fuel (SNF) rods are fractured in bending. An aerosol collection system was designed and tested to collect respirable sized (<10 μm aerodynamic diameter [AED]) particulates inside a hot cell facility. The setup is a modified version of the commercially available Sioutas cascade impactor, to which additional stages were added to expand the aerosol collection range from 2.5 to ~15 μm AED. To accommodate the additional stages and specific test conditions, the operating flow rate for aerosol collection was reduced, and testing was conducted by using pressure drop measurements, surrogate dust collection, and particle size characterization. The fluid flow distribution within the cascade and its stages was simulated in STAR-CCM+, and the stage-wise pressure drops obtained using the computational fluid dynamics model were then compared to experimental data. Lagrangian particle simulations were also performed, and stage-wise collection statistics were obtained from the simulation for comparison with the experimental data obtained using SNF-surrogate dust particles. The results provide valuable insights into the stage-wise particle collection characteristics of the modified cascade impactor and can also be used to improve the prediction accuracy of the manufacturer-determined analytical correlations.

aerosol modeling↗

Comparison of animal and human blood for in vitro dynamic thrombogenicity testing of biomaterials

Abstract Background To determine suitable alternatives to human blood for in vitro dynamic thrombogenicity testing of biomaterials, four different animal blood sources (ovine, bovine, and porcine blood from live donors, and abattoir porcine blood) were compared to fresh human blood. Methods To account for blood coagulability differences between individual donors and species, each blood pool was heparinized to a donor‐specific concentration immediately before testing in a dynamic flow loop system. The target heparin level was established using a static thrombosis pre‐test. For dynamic testing, whole blood was recirculated at room temperature for 1 h at 200 ml/min through a flow loop containing a single test material. Four materials with varying thrombotic potentials were investigated: latex (positive control), polytetrafluoroethylene (PTFE) (negative control), silicone (intermediate thrombotic potential), and high‐density polyethylene (HDPE) (historically thromboresistant). Thrombus weight and surface area coverage on the test materials were quantified, along with platelet count reduction in the blood. Results While donor‐specific heparin levels varied substantially from 0.6 U/ml to 7.0 U/ml among the different blood sources, each source was able to differentiate between the thrombogenic latex and the thromboresistant PTFE and HDPE materials ( p < 0.05). However, only donor ovine and bovine blood were sensitive enough to differentiate an increased response for the intermediate thrombotic silicone material compared to PTFE and HDPE. Conclusions These results demonstrated that multiple animal blood sources (particularly donor ovine and bovine blood) may be suitable alternatives to fresh human blood for dynamic thrombogenicity testing when appropriate control materials and donor‐specific anticoagulation levels are used.

Engineering↗

Epsilon Metal: A Waste Form for Noble Metals from Used Nuclear Fuel

Epsilon metal (e-metal) is the metallic phase that forms as inclusions at the grain boundaries in the UO2 fuel during reactor operation. This metal is composed of Pd, Mo, Rh, Ru, and Tc. These metallic inclusions are insoluble in strong acid and remnants of these metallic inclusions have been found in the UO2 matrix that remains from the natural reactors in Gabon that were active 1.8 billion years ago, therefore e-metal should be an excellent waste form for the immobilization of the long-lived isotopes 107Pd (6.5 ? 106 a) and 99Tc (2.13 ? 105 a), with 99Tc being the isotope of interest for repository performance. Therefore, the chemical durability of this potential waste form is assessed in this study. Typically, corrosion rates for metallic materials are measured electrochemically because they are quick, inexpensive, and can reveal the mechanism by which a metal corrodes, at least initially. However, in a repository the waste form would be subjected to slowly flowing water without an applied electrical potential over long time periods. Therefore, the corrosion rates of e-metal specimens were measured with both electrochemical tests and the single-pass flow-through test (SPFT). Potentiodynamic and potentiostatic polarization results suggest that a thin passive film exists on the alloy surface, which seems to be responsible for its high corrosion resistance. Additionally, X-Ray photoelectron spectroscopic results suggest that Pd oxides are significantly enriched in the passive film Results from the SPFT show that the dissolution rates were weakly dependent on pH. Only Mo and Re were found in solution and were used for the calculation of the dissolution rates. In general, the electrochemically determined corrosion rates agree reasonably well with the initial dissolution rate measured with the SPFT test, but they are about one or two orders of magnitude higher than the steady state rates. The causes for this discrepancy are discussed.

epsilon-metal, nuclear waste form, corrosion, sing↗

Overview of On-Line Optical Measurements at High Pressure for Flue Gases, Particulates and Acid-dew Point of Pressurized Oxy-Combustion

Optical flow cells are critical measurement interfaces, yet sampling under harsh conditions — high pressure, high temperature, particles, moisture, or corrosive gases — makes it difficult to maintain optical quality without perturbing the measurement. To address this challenge, a new flow cell was developed using a laminar coaxial flow field that separates the purge and sample flows. A dedicated test system was built to evaluate particle size distribution (PSD) measurements using a Malvern Panalytical Insitec analyzer. Results demonstrated that the sample flow alone defines the measurement zone, while the purge flow effectively shields the optical windows from deposition, eliminating sampling bias. The flow cell enables reliable PSD measurement under high pressure and temperature in moist, corrosive environments. As a key demonstration, the instrument was successfully deployed for on-line PSD measurement of flue gas from a 100 kWth pressurized oxy-coal combustor at 15 bara.

Cheng, Mao↗

Eddy Current Flow Meter Measurements and Modeling Validation

The goal of the eddy current flow meter (ECFM) is to monitor velocities and temperatures of conductive liquid metals. The ECFM can also detect voids in two-phase liquid metal flows. Measurement of these flows can greatly improve the accuracy of the empirical formulas used for fluid dynamics near the reactor core and aid in mapping any non-uniformities in fluid flow such as estimates of temperature and phase. While the eventual goal is to develop the ECFM for the liquid sodium surrounding the Versatile Test Reactor (VTR) core, this report focuses on modeling and experimental validation of ECFM for a moving solid test rod and for liquid mercury in the Target Test Facility (TTF) flow loop to better understand and further develop ECFM measurement capabilities by validating model predictions with benchmark experiments. Eventually the models could be used to design and optimize future ECFMs for specific applications such as monitoring flow within the VTR pool.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Instrumentation development and testing of a wind turbine blade for sub-scale wake studies

Wind turbine blade aerodynamics and the resulting wake flow are complex, and wind tunnel testing of these flows can provide critical insight. The data from such tests are also valuable for validation of numerical models. For experiments using sub-scale turbines to be useful, the blade aerodynamics and wakes must exhibit the important features observed in utility-scale turbine flows. In this work, ~1 m blades designed to produce physics relevant to larger scale turbines were manufactured and affixed to an existing turbine. One of the blades was instrumented for blade surface pressure measurements. Time-dependent surface pressure measurements coupled with instantaneous measurements of the inflow with Cobra probes and the wake with particle image velocimetry allowed for characterization of the inflow, blade flow, and near wake. The results demonstrate that the instrumentation was effective in characterizing the blade loading and the flow field. For the one test case discussed in this paper, the measurements of inflow, blade loading, and wake properties facilitate understanding of the wake's behavior.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Geomechanical and Hydrogeological Evaluation of a Shallow Hydraulic Fracture at the Devine Fracture Pilot Site, Medina County, Texas

UT-Austin’s Devine Fracture Pilot Site, 50 miles southwest of San Antonio, Texas, has been targeted for a comprehensive, multidisciplinary development of fracture diagnostic techniques that are cross-validated by ground-truth data acquisition near a recently created, 175-ft-deep, horizontal hydraulic fracture (Ahmadian et al. 2018 Demonstration of proof of concept of electromagnetic geophysical methods for high resolution illumination of induced fracture networks. In Proceedings of the SPE Hydraulic Fracturing Technology Conference and Exhibition, The Woodlands, Texas, USA, 23–25 January 2018. SPE-189858-MS.). To evaluate the fracture diagnostic methods at this site, we conducted injection tests with a predefined volumetric flow-rate profile, resembling a diagnostic fracture injection test on September 2020. Subsequently, we developed hydrogeological and geomechanical models based on flow-rate and bottomhole-pressure measurements. History-matching efforts using a simplified layer-cake hydrogeological model resulted in the field-scale formation permeability of 9.87 × 10 –15 m 2 (10 mD) and Darcy-scale fracture permeability. The analysis of the bottomhole pressure and injection-rate history showed that (1) the newly created horizontal fracture was closed adjacent to the injection well pre-injection and (2) the initial pump-pressure increase at a nominal volumetric injection rate led to near-well fracture reopening, fluid conductivity increase, and abrupt injection-rate increase. To overcome hydrogeological-model limitations of predicting fracture reopening throughout injection, we extended the modeling to a finite-element, poroelastic analysis of horizontal-fracture growth using a cohesive-zone model. Using this fracture-reopening model, we improved the history match of the transient-pressure response during the experiment by adjusting the hydromechanical properties. Furthermore, post-injection pressure transient analyses helped reduce uncertainty in the overburden-stress gradient, and the initial hydraulic-fracturing simulation verified the plausibility of achieving the surveyed propped fracture area.

02 PETROLEUM↗

Atomic-scale homogeneous plastic flow beyond near-theoretical yield stress in a metallic glass

Abstract The onset of yielding and the related atomic-scale plastic flow behavior of bulk metallic glasses at room temperature have not been fully understood due to the difficulty in performing the atomic-scale plastic deformation experiments needed to gain direct insight into the underlying fundamental deformation mechanisms. Here we overcome these limitations by combining a unique sample preparation method with atomic force microscopy-based indentation, which allows study of the yield stress, onset of yielding, and atomic-scale plastic flow of a platinum-based bulk metallic glass in volumes containing as little as approximately 1000 atoms. Yield stresses markedly higher than in conventional nanoindentation testing were observed, surpassing predictions from current models that relate yield stress to tested volumes; subsequent flow was then established to be homogeneous without exhibiting collective shear localization or loading rate dependence. Overall, variations in glass properties due to fluctuations of free volume are found to be much smaller than previously suggested.

Yu, Jiaxin↗

A mountain-induced moist baroclinic wave test case for the dynamical cores of atmospheric general circulation models

Idealized test cases for the dynamical cores of atmospheric general circulation models are informative tools to assess the accuracy of the numerical designs and investigate the general characteristics of atmospheric motions. A new test case is introduced that is built upon a baroclinically unstable base state with an added orographic barrier. The topography is analytically prescribed and acts as a trigger of both baroclinic Rossby waves and inertia–gravity waves on a rotating, regular-sized planet. Both dry and idealized moist configurations are suggested. The latter utilizes the Kessler warm-rain precipitation scheme. The test case enhances the complexity of the existing test suite hierarchy and focuses on the impacts of two midlatitudinal mountain ridges on the circulation. Selected simulation examples from four dynamical cores are shown. These are the Spectral Element and Finite Volume dynamical cores, which are part of the National Center for Atmospheric Research (NCAR) Community Earth System Model (CESM), versions 2.1.3 and 2.2, and the Cubed-Sphere Finite Volume dynamical cores, which is new to CESM version 2.2. In addition, the Model for Prediction Across Scales (MPAS) is tested. The overall flow patterns agree well in the four dynamical cores, but the details can vary greatly. The examples highlight the broad palette of use cases for the test case and reveal physics–dynamics coupling issues.

58 GEOSCIENCES↗

Dynamic response of a freely rotating butterfly valve in the advanced test reactor – dynamic fluid-body interaction modeling

To regulate primary coolant flow in the Advanced Test Reactor (ATR), a butterfly valve was installed between the primary coolant pumps and the reactor core. If the mechanical connection between the valve's disk and its shaft ever fails, the disk will rotate freely. Rapid disk rotation may induce pressure surges that could damage upstream pipes. In the present work, the rotational trajectory and pressure evolution during a disk free-rotation scenario were analyzed via the dynamic fluid-body interaction (DFBI) approach in STAR-CCM+, with the movement of a solid being driven by the forces and moment/torque imposed by its surrounding fluid. Assuming a large initial opening angle, the disk accelerates slowly, but swiftly passes the closed position. As a result of the sudden valve closure, a pressure surge occurs in the upstream pipes, exceeding their maximum allowable pressure. Furthermore, the disk does not stabilize at the closed position but continually oscillates due to the unsteady nature of the coolant flow. Because of the significant and continuous water hammer effect, a fix to the butterfly valve is being implemented to prevent rapid valve closure due to failure at the valve's disk/shaft mechanical connection.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design, Flow Field, and Heat Transfer Characterization of the Conjugate Aero-Thermal Test Facility at NETL

A new aerothermal test facility was constructed for the purpose of studying film cooling performance in an environment that accurately simulates conjugate heat transfer characteristics that exist in engine operation. Here, this paper details the design of the facility and the plan for conducting steady state film cooling experiments to improve the understanding of conjugate heat transfer scaling from laboratory to engine conditions. The test facility consists of two separate low channels (hot gas/coolant) and each gas path has a flow conditioning section, a convergent nozzle and a test section/channel with viewports. Numerical simulations were conducted to predict flow field characteristics supporting the design of the flow loop facility. Preliminary experiments were conducted to characterize the flow field using velocity and temperature profile measurements. In addition, infrared (IR) thermography methods were developed to measure surface temperatures on the hot side of the test plate. The IR measurement methods including calibration of the IR camera is explained in detail. It was concluded that appropriate hot gas path flow conditioning could be achieved using a strainer-like tube, a perforated plate, and a honeycomb-mesh screen system upstream of the test section. Flow field measurements from preliminary experiments showed that the boundary layer profile follows the law of the wall.

47 OTHER INSTRUMENTATION↗

Experimental Performance of a Nonlinear Control Strategy to Regulate Temperature of a High-Temperature Solar Reactor

Abstract Despite the significant potential of solar thermochemical process technology for storing solar energy as solid-state solar fuel, several challenges have made its industrial application difficult. It is important to note that solar energy has a transient nature that causes instability and reduces process efficiency. Therefore, it is crucial to implement a robust control system to regulate the process temperature and tackle the shortage of incoming solar energy during cloudy weather. In our previous works, different model-based control strategies were developed namely a proportional integral derivative controller (PID) with gain scheduling and adaptive model predictive control (MPC). These methods were tested numerically to regulate the temperature inside a high-temperature tubular solar reactor. In this work, the proposed control strategies were experimentally tested under various operation conditions. The controllers were challenged to track different setpoints (500 °C, 1000 °C, and 1450 °C) with different amounts of gas/particle flowrates. Additionally, the flow controller was tested to regulate the reactor temperature under a cloudy weather scenario. The ultimate goal was to produce 5 kg of reduced solar fuel magnesium manganese oxide (MgMn2O4) successfully, and the controllers were able to track the required process temperature and reject disturbances despite the system's strong nonlinearity. The experimental results showed a maximum error in the temperature setpoint of less than 0.5% (6 °C), and the MPC controller demonstrated superior performance in reducing the control effort and rejecting disturbances.

Energy & Fuels↗

Evolution of Permeability in Sandstone During Confined Brazilian Testing

Permeability measurements were made on sandstone during confined Brazilian strength tests. The test involves 50 mm diameter disk-shaped, jacketed samples that are subjected to confining stresses while they are diametrically loaded. Specially designed end caps allow for concurrent gas flow measurements. The test configuration allows for the samples to be subjected to a range of stresses, with the confining stress as the intermediate principal stress. Furthermore, the majority of the tests measured permeability during loading to failure in the confined extension region. The permeability of the sandstone sample increases significantly well before the peak load is reached due to newly formed microcracks that continue to coalesce and dilate with further loading. Permeability increases are inversely proportional to the intermediate principal stress as increased confining pressures suppress growth, coalescence, and dilation of microcracks. Additional testing includes unloading and reloading cycles prior to failure. With each unloading–reloading cycle, permeability at comparable stresses is increased compared to the previous cycle, consistent with increasing damage in the form of an expanding microcrack network.

58 GEOSCIENCES↗

In-Situ Blade Strain Measurements of a Crossflow Turbine Operating in a Tidal Flow

This data was collected between October 25 and December 12 of 2022 at the University of New Hampshire (UNH) and Atlantic Marine Energy Center (AMEC) turbine deployment platform (TDP). The goal was to collect blade strain data from a crossflow turbine operating in a tidal flow. A table in ('Deployment Schedule.PNG') outlines the various dates when each instrument was operational, and more details can be found via literature listed in 'Related Publications'.txt. This dataset includes zipped folders for each instrument containing data in .csv files for the relevant duration specific to each instrument, along with separate README file for each measurement. Some instrument files are quite large and can pose a challenge for a visual spreadsheet editor to open. A processing software like MATLAB or Python is recommended. All data contained in this submission is unfiltered/unprocessed data unless otherwise noted in the README file. Blade strain was measured using 8 foil-based strain gauges along the span of a single turbine blade. Water currents were measured using Acoustic Doppler Current Profilers (ADCP's) and Acoustic Doppler Velocimeters (ADV's) both upstream and downstream of the turbine for inflow, wake and turbulence measurements. Electrical power output was measured using the Voltsys rectifier. Shaft speed was calculated based on the Voltsys measurements of the permanent magnet three phase generator AC generation frequency, coupled directly to the cross flow turbine under test (i.e., no gear box). Platform motions were captured using a Yost IMU (inertial measurement unit). Turbine thrust loading was measured using a reaction arm about the turbine deployment platform spanning beam, where two bi-directional load cells were connected to the system via a pinned connection. The TDP is a floating structure moored on the Portsmouth facing side of Memorial Bridge pier #2, which spans the Piscataqua River between Portsmouth, NH and Kittery, ME. The Piscataqua River connects the Great Bay Estuary to the Gulf of Maine and the river currents are dominated by tidal flow with water velocities exceeding 2.5 m/s during spring ebb tides at this site which were previously characterized by Chancey 2019. The turbine under test was a modified New Energy Corporation (Calgary, CA) model EVG-025 4-blade H-Darrius type vertical axis cross flow turbine that rotates in the clockwise direction with a rotor diameter of 3.2m and blade length of 1.7m. The hydro-foil profile was a NACA 0021 with a 10 inch chord length and a blade preset pitch angle of +4deg with a positive angle corresponding with the toe in direction. The standard EVG-025 has a rotor diameter of 3.4m and its rated power output is 25kW at 3 m/s. The rotor diameter was reduced to accommodate the size of the existing TDP moon-pool. A single blade of this turbine was further modified to accommodate 8 full-bridge strain gauges (Bharath et al 2023, Bichanich et al 2024). For power performance and other relevant details on the turbine and its characteristics, see O'Byrne 2022.

16 TIDAL AND WAVE POWER↗

Instability and treatments of the coupled discrete element and lattice Boltzmann method by the immersed moving boundary scheme

The immersed moving boundary (IMB) scheme has been extensively used to couple the discrete element method (DEM) with the lattice Boltzmann method (LBM). In the literature, only the formulation of IMB for lattice nodal cells covered by a single-solid particle was given. The treatment of situations where a nodal cell is covered by two or more solid particles is seldom discussed. It is found that some numerical instability can occur for such situations due to an inappropriate computation of the weighting function in the IMB formulation. This work presents an enhanced treatment that can resolve the issue and validates it using some benchmark tests. Furthermore, to avoid the extra costs associated with the treatment and simplify the complicated procedure introduced, a simplified IMB scheme is proposed. The accuracy of both enhanced and simplified IMB schemes are validated by test cases including single-particle sedimentation, two-particle drafting-kissing-tumbling phenomenon, and multiple-particle sedimentation. Then, the robustness of both schemes is examined and discussed using a specially designed flow past cylinders test. Overall, the simplified IMB scheme is proved to be robust and sufficiently accurate and simpler and more effective than the enhanced scheme.

42 ENGINEERING↗

Joint Estimation of Topology and Injection Statistics in Distribution Grids with Missing Nodes

Optimal operation of distribution grid resources relies on accurate estimation of its state and topology. Practical estimation of such quantities is complicated by the limited presence of real-time meters. This article discusses a theoretical framework to jointly estimate the operational topology and statistics of injections in radial distribution grids under limited availability of nodal voltage measurements. In particular, we show that our proposed algorithms are able to provably learn the exact grid topology and injection statistics at all unobserved nodes as long as they are not adjacent. The algorithm design is based on novel ordered trends in voltage magnitude fluctuations at node groups, that are independently of interest for radial physical flow networks. The complexity of the designed algorithms is theoretically analyzed and their performance is validated using both linearized and nonlinear ac power flow samples in test distribution grids.

97 MATHEMATICS AND COMPUTING↗