Search NASA⌕ Search

SEARCH · Search NASA

Results for “forced cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Orographic Cirrus and Its Radiative Forcing in NCAR CAM6

Cirrus clouds play an important role in the Earth's radiative energy budget, thereby affecting the climate state and climate change. Orographic gravity wave (OGW)-induced sub-grid scale vertical velocity (i.e., cooling rate) is not resolved by large-scale models and its impact on ice formation in cirrus clouds is not well quantified. In this study, one sub-grid scale OGW scheme (e.g., McFarlane) is used in the Community Atmosphere Model version 6 (CAM6) to generate vertical velocity variance (σw) for cirrus formation. Results from the default model and simulations with the OGW-induced σw are evaluated against the DOE ARM Small Particles in Cirrus (SPARTICUS) campaign observations. The OGW based on the McFarlane scheme increases the sub-grid scale σw over mountains compared to the default model and improves the model agreement with the SPARTICUS observations. Larger σ w due to OGWs can trigger more frequent homogeneous nucleation in orographic cirrus and generates a higher number concentration of ice crystals observed during the SPARTICUS campaign. Moreover, our evaluation of the model simulations against satellite observations indicates that the McFarlane scheme generates high in-cloud ice number concentrations (>200 L -1 ) in the upper troposphere over mountains and high plateaus at mid- and high-latitudes of the winter hemisphere as shown in the observations. More ice crystals with smaller sizes absorb more infrared radiation (+0.523 ± 0.125 W m -2 ). The net radiative cloud forcing change at the top of the atmosphere is +0.330 W m -2 due to the orographic cirrus.

54 ENVIRONMENTAL SCIENCES↗

Summary Report of the FY24 DOE Contributions to the GIF VHTR CMVB

The Generation-IV Forum (GIF) Very-High-Temperature Reactor-Computational Methods Validation and Benchmark (VHTR-CMVB) initiative, involving organizations from Korea Atomic Energy Research Institute (KAERI) (South Korea), Institute of Nuclear and New Energy Technology of Tsinghua University (INET) (China), U.S. Department of Energy (DOE) (U.S.), Joint Research Centre (JRC) (Europe), and Japan Atomic Energy Agency (JAEA) (Japan), is dedicated to the verification and validation of tools for High-Temperature Gas-Cooled Reactors (HTGRs) analysis, using data shared by Computational Methods Validation and Benchmark (CMVB) signatories. For FY24, the US DOE CMVB has committed to several critical activities. Under WP1, led by the US, the integration of the High Temperature Gas Cooled Reactor - Pebble-Bed Module (HTR-PM) Phenomena Identification and Ranking Table (PIRT) into the comparative PIRT is progressing, with a new draft of the comparison tables issued earlier this year and currently being utilized by INET for their contribution. Neutronic validation efforts under WP3 include the preparation of the burnup analysis benchmark, preliminary calculations, and the development of reference models and results. In WP2, a validation exercise for hot gas mixing in the lower plenum of HTR-PM is in progress, using experimental data from INET (China) to validate modeling approaches. A model of the experimental facility has been developed using StarCCM+, with initial calculations slated for presentation at the GIF CMVB meeting this fall. Another WP2 activity focuses on validating numerical models for air-cooled Reactor Cavity Cooling System (RCCS) with experimental data from the Wisconsin Madison RCCS facility. A high-fidelity model, developed using NEK-RS, is currently being validated with available data from a low power forced convection test. These efforts are aimed at enhancing and confirming the accuracy of HTGR analysis tools, ensuring their alignment with experimental data and regulatory requirements.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

There and Back Again: Reimagining Cryogenic Cooling for Scalable Arrays of Dilution Refrigerators for future Quantum Datacenters

While pulse tube cryocoolers enabled the rapid expansion of dilution refrigerator technology over the past two decades, the transition to large-scale quantum systems is now driving a reassessment of the DR’s higher-temperature-stage cooling strategies and how these systems can be effectively scaled in a modular way. Quasi-wet architectures based on centralized cryoplants and forced-flow helium distribution offer compelling advantages in energy efficiency, operational cost, and scalability. With appropriate redundancy, standardized interfaces, and optimized distribution system designs, these architectures will provide a practical and robust path forward for the next generation of quantum computing infrastructure.

Hansen, B. [Fermilab]↗

Development of a scintillator based fast-ion loss detector for the Wendelstein 7-X stellarator

A new scintillator based fast-ion loss detector (FILD) system has been designed for the Wendelstein 7-X (W7-X) stellarator. The mechanical design of the system is presented here along with engineering analyses of the system. This includes an assessment of the structural loads which also considers electromagnetic forces calculated for possible disruption scenarios as well as a mode frequency analysis of the system. Furthermore, an analysis of the thermal characteristics of the actively cooled probe head under prescribed steady state and transient heat loads is presented. Finally, the optical relay system is described and its properties used to forward model synthetic camera signals using the FILDSIM code and based on theoretical fast-ion losses incident on the probe head calculated using the ASCOT5 code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dependence of Uranium Oxide Polymorphism on Plasma Synthesis Conditions

Here, we synthesized uranium oxide nanoparticles using a plasma flow reactor (PFR) and studied the effects of three different experimental parameters on the resulting morphologies and speciation of the particles: (1) collection duration, (2) collection substrate temperature, and (3) radial collection position due to radial temperature gradients in the PFR. We also induced three distinct temperature histories along the axis of the plasma flow reactor by varying the gas flow rates downstream of the plasma torch. Transmission electron microscopy (TEM) analyses of collected particles showed two phases of uranium oxides (fcc-UO 2 and α-UO 3 ). The chemical compositions of the resulting uranium oxide particles were not altered by the three parameters investigated in this work but varied based on the temperature history induced. Preheating of the collection substrate led to deposition of fewer particles, which is attributed to a reduction in thermophoretic force caused by the reduced temperature gradient for preheated substrates. The relative amounts of UO 2 to UO 3 and particle size varied depending on the cooling history employed during synthesis.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

OCEANFILMS (Organic Compounds from Ecosystems to Aerosols: Natural Films and Interfaces via Langmuir Molecular Surfactants) sea spray organic aerosol emissions – implementation in a global climate model and impacts on clouds

Sea spray aerosol is one of the major sources of atmospheric particulate matter globally. It has increasingly been recognized that organic matter derived from ocean biological precursors contributes significantly to the composition of submicron sea spray and may modify sea spray aerosol impacts on clouds and climate. This paper describes the implementation of the OCEANFILMS (Organic Compounds from Ecosystems to Aerosols: Natural Films and Interfaces via Langmuir Molecular Surfactants) parameterization for sea spray organic aerosol emissions in a global Earth system model, the Energy Exascale Earth System Model (E3SM). OCEANFILMS is a physically based model that links sea spray chemistry with ocean biogeochemistry using a Langmuir partitioning approach. We describe the implementation details of OCEANFILMS within E3SM, compare simulated aerosol fields with observations, and investigate impacts on simulated clouds and climate. Four sensitivity cases are tested, in which organic emissions either strictly add to or strictly replace sea salt emissions (in mass and number) and are either fully internally or fully externally mixed with sea salt. The simulation with internally mixed, added organics agrees reasonably well with observed seasonal cycles of organic matter in marine aerosol and has been selected as the default configuration of the E3SM. In this configuration, sea spray organic aerosol contributes an additional source of cloud condensation nuclei, adding up to 30 cm -3 to Southern Ocean boundary-layer cloud condensation nuclei concentrations (supersaturation = 0.1 %). The addition of this new aerosol source strengthens shortwave radiative cooling by clouds by -0.36 W m -2 in the global annual mean and contributes more than -3.5 W m -2 to summertime zonal mean cloud forcing in the Southern Ocean, with maximum zonal mean impacts of about -4 W m -2 around 50–60°S. This is consistent with a previous top-down, satellite-based empirical estimate of the radiative forcing by sea spray organic aerosol over the Southern Ocean. Through its mechanistic approach, OCEANFILMS offers a path towards improved understanding of the feedbacks between ocean biology, sea spray organic matter, and climate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Economic and environmental impacts of a non-traditional combined heat and power system for a discrete manufacturing facility

Combined heat and power (CHP) is an electricity generation strategy that benefits all sides with a vested interest in the nations’ energy future. The technology allows for the efficient production of electricity and heat, which in turn reduces the carbon footprint and energy costs of a facility with significant heat and electricity loads. This paper investigates, through a detailed dynamic simulation, how a highly non-traditional CHP facility can leverage those forces to economically and environmentally benefit. Four system configurations of a composites manufacturing facility, one existing and three proposed systems, including two CHP configurations and one combined cooling, heating, and power (CCHP) configuration are evaluated from both economic and environmental views. The three proposed configurations are based on a 600 kW microturbine as the primary mover. The dynamic model showed great potential to capture the dynamics of the system configurations including the dynamics of temperature, oven exhaust fraction, electrical efficiency, and overall efficiency of the system configurations. All 3 CHP systems have a payback period between 8.03 and 8.33 years. The proposed system configurations reduce up to 22.7% of the CO 2 emission compared to the existing facility, supplying the demands in a cleaner manner.

42 ENGINEERING↗

Dark black holes in the mass gap

Abstract In the standard picture of stellar evolution, pair-instability — the energy loss in stellar cores due to electron-positron pair production — is predicted to prevent the collapse of massive stars into black holes with mass in the range between approximately 50 and 130 solar masses — a range known as the “black hole mass gap”. LIGO and Virgo detection of black hole binary mergers containing one or both black holes with masses in thismass gapthus challenges the standard picture, possibly pointing to an unexpected merger history, unanticipated or poorly understood astrophysical mechanisms, or new physics. Here, we entertain the possibility that a “dark sector” exists, consisting of dark electrons, dark protons, and electromagnetic-like interactions, but no nuclear forces. Dark stars would inevitably form given such dark sector constituents, possibly collapsing into black holes with masses within the mass gap. We study in detail the cooling processes necessary for successful stellar collapse in the dark sector and show that for suitable choices of the particle masses, we indeed predict populating the mass gap with dark sector black holes. In particular, we numerically find that the heavier of the two dark sector massive particles cannot be lighter than, approximately, the visible sector proton for the resulting dark sector black holes to have masses within the mass gap. We discuss constraints on this scenario and how to test it with future, larger black hole merger statistics.

Astronomy & Astrophysics↗

AI for Extreme Volcanic Climate Forcing and Feedback Forecasting in the 21st century

Our paradigm-shifting framework will apply machine learning and perform physical analysis of contemporary volcanoes to develop sound forecasts of extreme eruptions in the 21stcentury and their abrupt drying and cooling impacts on the warming climate. We will also bridge climate data driven regression models and earth system model output to trace teleconnections that exacerbate regional impacts such as Arctic amplification and western US droughts.

54 ENVIRONMENTAL SCIENCES↗

On the Effect of Historical SST Patterns on Radiative Feedback

Here, we investigate the dependence of radiative feedback on the pattern of sea-surface temperature (SST) change in fourteen Atmospheric General Circulation Models (AGCMs) forced with observed variations in SST and sea-ice over the historical record from 1871 to near-present. We find that over 1871-1980, the Earth warmed with feedbacks largely consistent and strongly correlated with long term climate sensitivity feedbacks (diagnosed from corresponding atmosphere-ocean GCM abrupt 4xCO2 simulations). Post 1980 however, the Earth warmed with unusual trends in tropical Pacific SSTs (enhanced warming in the west, cooling in the east) and cooling in the Southern Ocean that drove climate feedback to be uncorrelated with – and indicating much lower climate sensitivity than – that expected for long-term CO 2 increase. We show that these conclusions are not strongly dependent on the AMIP II SST dataset used to force the AGCMs, though the magnitude of feedback post 1980 is generally smaller in nine AGCMs forced with alternative HadISST1 SST boundary conditions. We quantify a ‘pattern effect’ (defined as the difference between historical and longterm CO 2 feedback) equal to 0.48 ± 0.47 [5-95%] W m -2 K -1 for the time-period 1871-2010 when the AGCMs are forced with HadISST1 SSTs, or 0.70 ± 0.47 [5-95%] W m -2 K -1 when forced with AMIP II SSTs. Assessed changes in the Earth’s historical energy budget agree with the AGCM feedback estimates. Furthermore satellite observations of changes in top-of-atmosphere radiative fluxes since 1985 suggest that the pattern effect was particularly strong over recent decades but may be waning post 2014.

54 ENVIRONMENTAL SCIENCES↗

Variant selection in laser powder bed fusion of non-spherical Ti-6Al-4V powder

The presence of α/α' on prior β/β grain boundaries directly impacts the final mechanical properties of the titanium alloys. The β/β grain boundary variant selection of titanium alloys has been assumed to be unlikely owing to the high cooling rates in laser powder bed fusion (L-PBF). However, we hypothesize that powder characteristics such as morphology (non-spherical) and particle size (50–120 µm) could affect the initial variant selection in L-PBF processed Ti-6Al-4V alloy by locally altering the cooling rates. Despite the high cooling rate found in L-PBF, the results showed the presence of β/β grain boundary α' lath growth inside two adjacent prior β grains. Electron backscatter diffraction micrographs confirmed the presence of β/β grain boundary variant selection, and synchrotron X-ray high-speed imaging observation revealed the role of the “shadowing effect” on the locally decreased cooling rate because of keyhole depth reduction and the consequent β/β grain boundary α' lath growth. The self-accommodation mechanism was the main variant selection driving force, and the most abundant α/α boundary variant was type 4 (63.26°//[ $\bar{10}$ 5 5 $\bar{3}$ ]). The dominance of Category II α lath clusters associated with the type 4 α/α boundary variant was validated using the phenomenological theory of martensite transformations and analytical calculations, from which the stress needed for the β→α' transformation was calculated.

36 MATERIALS SCIENCE↗

SD-WAN Evaluation Criteria for a Defense Information Systems Network Expeditionary Customer Edge

The Defense Information Systems Agency (DISA) has identified a service provision gap midway between the capacity and capability of a Defense Information Systems Network (DISN) transport Edge Points of Presence (POP) and U.S. Department of Defense (DoD) Enterprise Classified Travel Kit (DECTK). Some deployed force 100-user Tactical Operations Centers are in field locations far removed from the DISN transport core, in challenging environmental conditions with limitations on space, weight, power, and cooling for network equipment. As part of a multi-phase project, Pacific Northwest National Laboratory (PNNL) will gather and analyze requirements, design, develop, prototype, and test a miniaturized and ruggedized DISN Customer Edge POP scaled to support approximately 100 users in a field Tactical Operations Center. An Expeditionary Customer Edge (ECE) will be more suitable for field deployment than a DISN transport Edge POP, using ruggedized hardware and network function virtualization (NFV) to operate in challenging field environmental conditions, plus reduce weight, power, and cooling requirements. A key enabling technology for ECE is Software Defined Wide Area Networking (SD-WAN). This document provides: • A brief overview of SD-WAN use cases and how they apply to ECE • How SD-WAN technology compares to existing networks like DISN that use Optical Transport Networking (OTN) and Multiprotocol Label Switching (MPLS) • SD-WAN functional requirements relevant to ECE • A description of an ECE Virtual Prototype, including simulated wide area network paths and a DISN-representative implementation of MPLS, in Cisco Modeling Labs • Detailed network flow walkthroughs • Evaluation criteria based on ECE-relevant SD-WAN functional requirements Finally, an appendix provides an informal evaluation of Speedify—a commercial retail Virtual Private Network service—against the ECE SD-WAN evaluation criteria.

42 ENGINEERING↗

Response of Indian summer monsoon rainfall to remote carbonaceous aerosols at short time scales: Teleconnections and feedbacks

The effect of atmospheric aerosols on Indian monsoon is one of the scientifically challenging and societally relevant research issues of the recent decades. Past studies have derived inferences mostly based on local emissions and their impacts thereupon. However, more recent studies have shown that the remote effects driven by aerosols elsewhere could also impact the monsoon system on different time scales. Our study using an atmospheric general circulation model (AGCM) shows that regional carbonaceous aerosol emissions (from North America, Europe and North Africa and Asia) can significantly alter Indian summer monsoon rainfall. It is interesting to note that the effects of remote aerosols are larger and bear a resemblance to each other in comparison to local emissions. Here, our study reveals that the modulation of large-scale circulation induced by regional warming by carbonaceous aerosols leads to teleconnection patterns around the globe, thereby changing the precipitation depending on the phase of these disturbances. We also find that the effects of remote carbonaceous aerosols are strengthened by modulation/feedback through natural dust aerosols over the Arabian Sea with subsequent increase in rainfall over India. The results signify that the changes in the aerosol emissions in one region could lead to the change in precipitation over other regions through global teleconnection and associated feedbacks induced by regional atmospheric warming and/or cooling.

Carbonaceous aerosols↗

Optimal Design and Operation of Intensified Absorbers with 3D-Printed Packing for Solvent-Based CO 2 Capture

Many potential solvent-based carbon capture processes suffer from a high heat of absorption of CO 2 that adversely affects the thermodynamic driving force. While interstage coolers are often used for removing a portion of the generated heat by removing the solvent or a portion of the solvent from a stage and cooling and returning it back to the absorber, they can be placed only at discrete locations in the tower. This work investigates intensified absorbers with 3D-printed packing that includes an internal cooler and therefore can be potentially used for maximizing the operational efficiency of the absorbers for CO 2 capture. The intensified absorber is modeled by using a generic, first-principles, equation-oriented absorber column model. Since the placement of these intensified packings would cause a loss of area/volume used for mass transfer, optimization of the proposed intensified absorber is performed by optimally selecting the locations at which to place these devices and designing them such that the trade-off due to the addition of the heat removal area and the resulting loss in the mass transfer area is accounted for. Results show that optimally placed and designed intensified packings can lead to a significant increase in the capture efficiency of the process in comparison to a similar column with no internal cooling. It is also observed that by optimally placing and designing intensified packings, the lean solvent flow rate to the absorber can be decreased, and the CO 2 lean loading can be increased while still maintaining the same capture efficiency. These process changes can lead to a substantial reduction in the cost of capture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

North Atlantic Oscillation response in GeoMIP experiments G6solar and G6sulfur: why detailed modelling is needed for understanding regional implications of solar radiation management

The realization of the difficulty of limiting global-mean temperatures to within 1.5 or 2.0°C above pre-industrial levels stipulated by the 21st Conference of Parties in Paris has led to increased interest in solar radiation management (SRM) techniques. Proposed SRM schemes aim to increase planetary albedo to reflect more sunlight back to space and induce a cooling that acts to partially offset global warming. Under the auspices of the Geoengineering Model Intercomparison Project, we have performed model experiments whereby global temperature under the high-forcing SSP5-8.5 scenario is reduced to follow that of the medium-forcing SSP2-4.5 scenario. Two different mechanisms to achieve this are employed: the first via a reduction in the solar constant (experiment G6solar) and the second via modelling injections of sulfur dioxide (experiment G6sulfur) which forms sulfate aerosol in the stratosphere. Results from two state-of-the-art coupled Earth system models (UKESM1 and CESM2-WACCM6) both show an impact on the North Atlantic Oscillation (NAO) in G6sulfur but not in G6solar. Both models show a persistent positive anomaly in the NAO during the Northern Hemisphere winter season in G6sulfur, suggesting an increase in zonal flow and an increase in North Atlantic storm track activity impacting the Eurasian continent and leading to high-latitude warming over Europe and Asia. These results are broadly consistent with previous findings which show similar impacts from stratospheric volcanic aerosol on the NAO and emphasize that detailed modelling of geoengineering processes is required if accurate impacts of SRM effects are to be simulated. Differences remain between the two models in predicting regional changes over the continental USA and Africa, suggesting that more models need to perform such simulations before attempting to draw any conclusions regarding potential continental-scale climate change under SRM.

36 MATERIALS SCIENCE↗

Design Challenges in High-Current Pulsed Striplines

The Long Baseline Neutrino Facility (LBNF) will produce the worlds most intense neutrino beam. Three series connected magnetic horns will require 5 kV, 300 kA, 800 $\mu$s pulses at a rate of 1.4 Hz to focus the beam. Connecting a single power supply to these focusing horns will require a low impedance connection measuring over 60 m in length. To meet the challenging requirements of connecting the horns to the power supply, this connection is engineered as a nine-conductor, high-current pulsed stripline. It must pass through a harsh radiation environment, be passively cooled, and have an operational lifetime of at least 30 years. This paper discusses mechanical and electrical considerations such as high-voltage holdoff, clamped joint performance, and Lorentz force mitigations in order to meet the specified requirements. The results of tests and experiments on several prototypes of key design features will be presented and discussed.

43 PARTICLE ACCELERATORS↗

AI for Extreme Volcanic Climate Forcing and Feedback Forecasting in the 21st century

Focal Areas: Our paradigm-shifting framework will apply machine learning and perform physical analysis of contemporary volcanoes to develop sound forecasts of extreme eruptions in the 21st century and their abrupt drying and cooling impacts on the warming climate. We will also bridge climate data driven regression models and earth system model output to trace teleconnections that exacerbate regional impacts such as Arctic amplification and western US droughts.

54 ENVIRONMENTAL SCIENCES↗

Thermodynamic Model and Initial Experimental Investigation of Air Dehumidification through Electrically Charged Vapor Capturing Electrostatic Droplets

The removal of water vapor from the air to reduce relative humidity is a well known indoor environmental comfort requirement. Common dehumidification approaches require a substantial amount of energy and usually involve the cooling of atmospheric humid air below its dew point or the use of absorbent/adsorbent materials to extract water vapor out of the air. More recently, researchers investigated the effect of electrostatic forces for enhancing water vapor condensation with the goal to reduce the energy consumption associated with dehumidification. However, the studies are limited, and there is a lack of correlations that can predict the dehumidification rate. In this thesis, a broad theoretical investigation to study the electrostatically enhanced condensation processes was carried out. These processes consist of the use of highly charged particles, preferably highly charged water droplets to attract polar water vapor molecules to their surfaces and promote condensation, a phenomenon known as dielectrophoresis. The electrical charge promotes the reduction of the vapor pressure on the droplets' surface with respect to the saturated pressure predicted by the Kelvin equation on curved surfaces and, consequently, the equilibrium between evaporation and condensation is shifted towards condensation. This investigation resulted in the development of a thermodynamics model, which was able to predict an effective size range of the charged droplets for optimal dehumidification, under ideal conditions. The range resulted in about 2 to 4 m in diameter, while the electrical charge was kept to the maximum limit predicted by the Rayleigh model. A sensitivity analysis on the variation of the size and the charge of the charged droplets was also performed. In terms of dehumidification rates, when six electrospray heads, i.e. the maximum number of heads tested in the experimental campaign, were considered, the model predicted very limited rates, way lower than the target of this research, i.e. a dehumidification rate in terms of relative humidity of 5 % with an air flow rate of 5 cfm. While ways to increase this rate existed, their implementation proved difficult for this initial investigation. According to the requirements predicted by the model, the use of electrosprays appeared the most suitable solution for the production of small but highly charged droplets. The electrospray features and operational modes were studied in detail and an electrospray assembly was designed to be tested in this initial experimental investigation. For this initial investigation, an experimental system was designed and built to validate the thermodynamics model and with the goal to achieve a dehumidification rate of 5 % in terms of relative humidity with an air flow rate of 5 cfm. The experimental system consisted of a wind tunnel test apparatus, dew point sensors, thermocouples for temperature measurements, pressure sensors and other devices. The experimental system was equipped with a computerized data acquisition and storage system. The system was suitable to evaluate the air water content differential before and after the test section where the electrospray heads were installed. The air water content differential was evaluated in terms of the ∆ω/ω_1 ratio, to eliminate the dependence on the dry bulb temperature along the test apparatus. This work presented initial experimental data for electrostatically enhanced dehumidification processes. Working parameters, such as air and water flow rates, high voltage potentials and polarity, deionized water types with different electrical conductivity, were varied to find the best combination for an improved dehumidification. With the set up used and the conditions considered, it was never possible to achieve a 5 % dehumidification rate with 5 cfm. In general, the dehumidification rate was always limited and lower than 1 % for all the air flow rates considered and mainly within the uncertainty of the dew point sensors. These results confirmed the already limited predictions of the thermodynamics model, for ideal conditions and the interesting and promising results obtained in some experimental investigations available in the open literature were not achievable in this thesis. The more probable reasons were the higher air flow rates considered and the complete absence of the use of cooling power, which was mainly implemented to facilitate the vapor condensation.

Morcelli, Stefano↗