At least 199 records · Page 11

Long-term microwave power drift of a cesium frequency standard and its effect on output frequency

It has been shown that the long-term frequency stability of a cesium (Cs) frequency standard is affected by variations in the standard's internal microwave power source. Studies were performed on a commercial Cs frequency standard for a period of 20 days, to determine the stability of its microwave power source. The results were then analyzed statistically, and the effects of microwave power drift on the standard's frequency stability were calculated.

Johnson, W. A.↗

Linear Ion Trap For Atomic Clock

Linear, radio-frequency ion trap increases frequency stability of atomic frequency standard device. Confines ions with less radio-frequency motion than does point ion trap.

Prestage, John D.↗

Interim results from the characterization testing of the Engineering Development (EDM) rubidium clocks for satellite applications

Some interim results from the environmental testing program to evaluate the Engineering Design Model (EDM) of the EG and G Spaceborne Rubidium Clock are presented. This effort is in support of the Global Positioning System (GPS) BLOCK IIR program and is intended to characterize the performance of EG and G design for BLOCK IIR satellite applications. Two EG and G EDM units are currently under test at NRL's Clock Test Facility to measure the long-term frequency stability, drift, and frequency versus temperature characteristics.

Powers, Edward D., Jr.↗

Error Analysis of Wind Measurements for the University of Illinois Sodium Doppler Temperature System

Four-frequency lidar measurements of temperature and wind velocity require accurate frequency tuning to an absolute reference and long term frequency stability. We quantify frequency tuning errors for the Illinois sodium system, to measure absolute frequencies and a reference interferometer to measure relative frequencies. To determine laser tuning errors, we monitor the vapor cell and interferometer during lidar data acquisition and analyze the two signals for variations as functions of time. Both sodium cell and interferometer are the same as those used to frequency tune the laser. By quantifying the frequency variations of the laser during data acquisition, an error analysis of temperature and wind measurements can be calculated. These error bounds determine the confidence in the calculated temperatures and wind velocities.

Pfenninger, W. Matthew↗

Precision frequency synthesizing sources with excellent time/frequency performances

Precision frequency synthesizing sources are needed in the time / frequency measuring system, atomic frequency standards, telemetry, communication, and radar systems. This kind of frequency synthesizing source possesses high frequency accuracy and excellent long term and short term frequency stability. Several precision frequency synthesizing sources developed by Beijing Institute of Radio Metrology and Measurement (BIRMM) which have been successfully applied to the time / frequency measuring system, atomic frequency standards system, and radar system are described. In addition, the working principle, implementation approach, and the main technical specifications of the frequency synthesizing sources are also given.

Zhou, Liren↗

NASA Tech Briefs, May 2012

Topics covered include: An "Inefficient Fin" Non-Dimensional Parameter to Measure Gas Temperatures Efficiently; On-Wafer Measurement of a Multi-Stage MMIC Amplifier with 10 dB of Gain at 475 GHz; Software to Control and Monitor Gas Streams; Miniaturized Laser Heterodyne Radiometer (LHR) for Measurements of Greenhouse Gases in the Atmospheric Column; Anomaly Detection in Test Equipment via Sliding Mode Observers; Absolute Position of Targets Measured Through a Chamber Window Using Lidar Metrology Systems; Goldstone Solar System Radar Waveform Generator; Fast and Adaptive Lossless Onboard Hyperspectral Data Compression System; Iridium Interfacial Stack - IrIS; Downsampling Photodetector Array with Windowing; Optical Phase Recovery and Locking in a PPM Laser Communication Link; High-Speed Edge-Detecting Line Scan Smart Camera; Optical Communications Channel Combiner; Development of Thermal Infrared Sensor to Supplement Operational Land Imager; Amplitude-Stabilized Oscillator for a Capacitance-Probe Electrometer; Automated Performance Characterization of DSN System Frequency Stability Using Spacecraft Tracking Data; Histogrammatic Method for Determining Relative Abundance of Input Gas Pulse; Predictive Sea State Estimation for Automated Ride Control and Handling - PSSEARCH; LEGION: Lightweight Expandable Group of Independently Operating Nodes; Real-Time Projection to Verify Plan Success During Execution; Automated Performance Characterization of DSN System Frequency Stability Using Spacecraft Tracking Data; Web-Based Customizable Viewer for Mars Network Overflight Opportunities; Fabrication of a Cryogenic Terahertz Emitter for Bolometer Focal Plane Calibrations; Fabrication of an Absorber-Coupled MKID Detector; Graphene Transparent Conductive Electrodes for Next- Generation Microshutter Arrays; Method of Bonding Optical Elements with Near-Zero Displacement; Free-Mass and Interface Configurations of Hammering Mechanisms; Wavefront Compensation Segmented Mirror Sensing and Control; Long-Life, Lightweight, Multi-Roller Traction Drives for Planetary Vehicle Surface Exploration; Reliable Optical Pump Architecture for Highly Coherent Lasers Used in Space Metrology Applications; Electrochemical Ultracapacitors Using Graphitic Nanostacks; Improved Whole-Blood-Staining Device; Monitoring Location and Angular Orientation of a Pill; Molecular Technique to Reduce PCR Bias for Deeper Understanding of Microbial Diversity; Laser Ablation Electrodynamic Ion Funnel for In Situ Mass Spectrometry on Mars; High-Altitude MMIC Sounding Radiometer for the Global Hawk Unmanned Aerial Vehicle; PRTs and Their Bonding for Long-Duration, Extreme-Temperature Environments; Mid- and Long-IR Broadband Quantum Well Photodetector; 3D Display Using Conjugated Multiband Bandpass Filters; Real-Time, Non-Intrusive Detection of Liquid Nitrogen in Liquid Oxygen at High Pressure and High Flow; Method to Enhance the Operation of an Optical Inspection Instrument Using Spatial Light Modulators; Dual-Compartment Inflatable Suitlock; Large-Strain Transparent Magnetoactive Polymer Nanocomposites; Thermodynamic Vent System for an On-Orbit Cryogenic Reaction Control Engine; Time Distribution Using SpaceWire in the SCaN Testbed on ISS; and Techniques for Solution- Assisted Optical Contacting.

Source record↗

(abstract) The Role of the Deep Space Network for Cassini

Cassini radio science experiments have several categories of requirements for DSN tracking services. The three main areas for upgrade are in Ka-band, long-term frequence stability, and short-term frequency stability/phase noise level.

Cassini Deep Space Network telecommunications Grav↗

Cryogenic masers

Various factors affecting the frequency stability of hydrogen masers are described and related to maser design parameters. The long-term frequency stability of a hydrogen maser is limited by the mechanical stability of the cavity, and the magnitudes of the wall relaxation, spin exchange, and recombination rates which affect the Q of the line. Magnetic resonance studies of hydrogen atoms at temperatures below 1 K and in containers coated with liquid helium films demonstrated that cryogenic masers may allow substantial improvements in all of these parameters. In particular the thermal expansion coefficients of most materials are negligible at 1 K. Spin exchange broadening is three orders of magnitude smaller at 1 K than at room temperature, and the recombination and wall relaxation rates are negligible at 0.52 K where the frequency shift due to the 4 He-coated walls of the container has a broad minimum as a function of temperature. Other advantages of the helium-cooled maser result from the high purity, homogeneity, and resilence of helium-film-coated walls and the natural compatibility of the apparatus with helium-cooled amplifiers.

Berlinsky, A. J.↗

Laser heterodyne spectrometer for helioseismology

The technique of laser heterodyne spectroscopy has been applied to the measurement of solar oscillations. Coherent mixing of solar radiation with the output of a frequency-stabilized CO2 laser permits the measurement of fully resolved profiles of solar absorption lines with high spectral purity and excellent frequency stability. This technique has been used to measure OH pure rotation lines in the infrared solar spectrum. Power spectra of these line frequency measurements show the well-known 5-min oscillations as well as significant velocity power at shorter periods.

Glenar, D. A.↗

Interplanetary phase scintillation and the search for very low frequency gravitational radiation

Observations of radio-wave phase scintillation are reported which used the Viking spacecraft having an earth-spacecraft link very similar to that which will be used in very low-frequency (VLF) gravitational-wave searches. The phase power-spectrum level varies by seven orders of magnitude as the sun-earth-spacecraft (elongation) angle changes from 1 to 175 deg. It is noteworthy that a broad minimum in the S-band (2.3 GHz) phase fluctuation occurs in the antisolar direction; the corresponding fractional frequency stability (square root Allan variance) is about 3 x 10 to the -14th for 1000-s integration times. A simultaneous two-frequency two-station observation indicates that the contribution to the phase fluctuation from the ionosphere is significant but dominated by the contribution from the interplanetary medium. Nondispersive tropospheric scintillation was not detected (upper limit to fractional frequency stability about 5 x 10 to the -14th). Evidently, even observations in the antisolar direction will require higher radio frequencies, phase scintillation calibration, and correlation techniques in the data processing, for detection of gravitational bursts at the anticipated strain amplitude levels of no more than 10 to the -15th.

Armstrong, J. W.↗

Precision and Fast Wavelength Tuning of a Dynamically Phase-Locked Widely-Tunable Laser

We report a precision and fast wavelength tuning technique demonstrated for a digital-supermode distributed Bragg reflector laser. The laser was dynamically offset-locked to a frequency-stabilized master laser using an optical phase-locked loop, enabling precision fast tuning to and from any frequencies within a ~40-GHz tuning range. The offset frequency noise was suppressed to the statically offset-locked level in less than ~40 s upon each frequency switch, allowing the laser to retain the absolute frequency stability of the master laser. This technique satisfies stringent requirements for gas sensing lidars and enables other applications that require such well-controlled precision fast tuning.

Numata, Kenji↗

Physics of systematic frequency variations in hydrogen masers

The frequency stability of hydrogen masers for intervals longer than 10 exp 4 s is currently limited by systematic processes. The physics of frequency-determining mechanisms internal to the maser that are susceptible to systematic variations, and the connections between these internal mechanisms and external environmental factors are discussed. From estimates of the magnitudes of systematic effects, it is found that the primary internal mechanisms limiting long-term maser frequency stability are cavity pulling, at the level of parts in 1015 per day, and wall shift variations, at the level of parts in 10 exp 16 to parts in 10 exp 15 per day. Strategies for reducing systematic frequency variations are discussed.

Mattison, Edward M.↗

Physics of systematic frequency variations in hydrogen masers

The frequency stability of hydrogen masers for intervals longer that 10(exp 4) seconds is limited at present by systematic processes. Researchers discuss the physics of frequency-determining mechanisms internal to the maser that are susceptible to systematic variations, and the connections between these internal mechanisms and external environmental factors. Based upon estimates of the magnitudes of systematic effects, they find that the primary internal mechanisms currently limiting long-term maser frequency stability are cavity pulling, at the level parts in 10(exp 15) per day, and wall shift variations, at the level of parts in 10(exp 16) to parts in 10(exp 15) per day. They discuss strategies for reducing systematic frequency variations.

Mattison, Edward M.↗

Automated frequency standard stability data reduction

A design using a medium sized computer, a fiber optic communication link, and a desk top computer to reduce data collected at a remote site for analysis of frequency standard tests is described. Data generated at the Interim Frequency Standards Test Facility is collected on magnetic tape, which is then transported to a Sigma 5 computer. An Allan variance (two sample variance) is then calculated. The Allan variance (sigma vs tau) is then written to a data file in the Sigma 5. A fiber optic communication link between the Sigma 5 and a desk top computer was designed to transmit data in the Sigma 5 file to the desk top computer. A program was written for the desk top computer that will automatically access the data file in the Sigma 5, process the data and provide a data plot.

Knapp, L. J.↗

Prospects for advances in microwave atomic frequency standards

Traditional standards based on rubidium, cesium and hydrogen have been greatly refined over the past decade, such that the frequency stability of the current generation of devices is generally limited by those basic concepts on which they are based. Future advances in frequency stability will principally come from changes in the concepts on which the standards are based, and only secondarily from more careful engineering of the old concepts. The fundamental limitations in these standards are considered and the important conceptual and component advances which could have a major impact on future performance of these standards are indicated. A very promising new class of microwave standards based on ion storage techniques is examined.

Walls, F. L.↗

The flight performance of the Galileo orbiter USO

Results are presented in this article from an analysis of radio metric data received by the DSN stations from the Galileo spacecraft using an Ultrastable Oscillator (USO) as a signal source. These results allow the health and performance of the Galileo USO to be evaluated, and are used to calibrate this Radio Science instrument and the data acquired for Radio Science experiments such as the Redshift Observation, Solar Conjunction, and Jovian occultations. Estimates for the USO-referenced, spacecraft-transmitted frequency and frequency stability were made for 82 data acquisition passes conducted between launch (Oct. 1989) and Nov. 1991. Analyses of the spacecraft-transmitted frequencies show that the USO is behaving as expected. The USO was powered off and then back on in Aug. 1991 with no adverse effect on its performance. The frequency stabilities measured by Allan deviation are consistent with expected values due to thermal wideband noise and the USO itself at the appropriate time intervals. The Galileo USO appears to be healthy and functioning normally in a reasonable manner.

Morabito, D. D.↗

The flight performance of the Galileo orbiter USO

Results are presented from an analysis of radio metric data received by the DSN stations from the Galileo spacecraft using an Ultrastable Oscillator (USO) as a signal source. These results allow the health and performance of the Galileo USO to be evaluated, and are used to calibrate this Radio Science instrument and the data acquired for Radio Science experiments such as the Red-shift Observation, Solar Conjunction, and Jovian occultations. Estimates for the USO-referenced spacecraft-transmitted frequency and frequency stability were made for 82 data acquisition passes conducted between launch (October 1989) and November 1991. Analyses of the spacecraft-transmitted frequencies show that the USO is behaving as expected. The USO was powered off and then back on in August 1991 with no adverse effect on its performance. The frequency stabilities measured by Allan deviation are consistent with expected values due to thermal wideband noise and the USO itself at the appropriate time intervals. The Galileo USO appears to be healthy and functioning normally in a reasonable manner.

Morabito, D. D.↗