Search NASA⌕ Search

SEARCH · Search NASA

Results for “gamma detection system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Micro cavity fission chamber radiation detection system

A radiation detector to monitor the neutron flux of a nuclear reactor or other high-radiation environment, that can withstand the high temperatures and radiation fields of such environment, is provided. A small dielectric substrate with a low neutron-activation cross section is provided. The substrate is coated with a neutron conversion material, such as uranium oxide or thorium oxide. One or more substrates form a micro-sized detection cavity that is filled with a detection gas. A voltage is provided across anode and cathode wires in the detection cavity. A neutron absorbed in the conversion material may release reaction products into the gas, causing ionization of the gas which then produces a current or voltage signal. The small detector volume minimizes energy deposition into the detection gas by competing particles such as gamma rays, fast electrons, and beta particles, and therefore minimizes false counts while retaining large signals from neutron interactions.

McGregor, Douglas S.↗

Towards a new generation of solid total-energy detectors for neutron-capture time-of-flight experiments with intense neutron beams

Challenging neutron-capture cross-section measurements of small cross sections and samples with a very limited number of atoms require high-flux time-of-flight facilities. In turn, such facilities need innovative detection setups that are fast, have low sensitivity to neutrons, can quickly recover from the so-called γ-flash, and offer the highest possible detection sensitivity. In this paper, we present several steps towards such advanced systems. Specifically, we describe the performance of a high-sensitivity experimental setup at CERN n_TOF EAR2. It consists of nine sTED detector modules in a compact cylindrical configuration, two conventional used large-volume C 6 D 6 detectors, and one LaCl 3 (Ce) detector. The performance of these detection systems is compared using 93 Nb(n, γ) data. We also developed a detailed G EANT small4 Monte Carlo model of the experimental EAR2 setup, which allows for a better understanding of the detector features, including their efficiency determination. This Monte Carlo model has been used for further optimization, thus leading to a new conceptual design of a γ detector array, STAR, based on a deuterated-stilbene crystal array. Finally, the suitability of deuterated-stilbene crystals for the future STAR array is investigated experimentally utilizing a small stilbene-d12 prototype. The results suggest a similar or superior performance of STAR with respect to other setups based on liquid-scintillators, and allow for additional features such as neutron-gamma discrimination and a higher level of customization capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

12 C(p,p') 12 C Reaction ( E p =19.5–30 MeV) for Active Interrogation of Special Nuclear Material

Passive detection of special nuclear material (SNM) is challenging due to its inherently low rate of spontaneous emission of penetrating radiation, the relative ease of shielding, and the fluctuating and frequently overwhelming background. Active interrogation, the use of external radiation to increase the emission rate of characteristic radiation from SNM, has long been considered to be a promising method to overcome those challenges. Current active-interrogation systems that incorporate radiography tend to use bremsstrahlung beams, which can deliver high radiation doses. Low-energy ion-driven nuclear reactions that produce multiple monoenergetic photons may be used as an alternative. The 12 C ( p , p ' ) 12 C reaction is one such reaction that could produce large yields of highly penetrating 4.4- and 15.1-MeV gamma rays. This reaction does not directly produce neutrons below the approximately 19.7 MeV threshold, and the 15.1-MeV gamma-ray line is well matched to the photofission cross section of 235 U and 238 U . In this article, we report the measurements of thick-target gamma-ray yields at 4.4 and 15.1 MeV from the 12 C ( p , p ' ) 12 C reaction at proton energies of 19.5, 25, and 30 MeV. Measurements are made with two 3 -in. EJ-309 cylindrical liquid scintillation detectors and thermoluminescent dosimeters placed at 0 ° and 90 ° , with an additional 1.5 -in. Na I ( Tl ) cylindrical scintillation detector at 0 ° . We estimate the highest yields of the 4.4- and 15.1-MeV gamma rays of 1.65 × 10 10 and 4.47 × 10 8 sr - 1 μ C - 1 at a proton energy of 30 MeV, respectively. The yields in all experimental configurations are greater than in a comparable deuteron-driven reaction that produces the same gamma-ray energies— 11 B ( d , n γ ) 12 C . However, a significant increase of the neutron radiation dose accompanies the proton energy increase from 19.5 to 30 MeV.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Gamma Discriminating Scintillation Screens for Digital Transfer Method Neutron Imaging

A collaborative project between Idaho National Laboratory (INL) and Paul-Scherrer Institute (PSI) is investigating a new type of scintillation screen that uses ZnS scintillator material with a dysprosium neutron converter instead of traditional prompt converters such as 6Li. Such a screen exposed to a neutron beam creates a latent image by neutron activation of the dysprosium in the scintillator screen. The activated screen is transported into a camera box allowing the camera to read a digital image from the photons emitted by the activated scintillation screen. Such an imaging system combines modern camera-based system architecture with the approach of traditional indirect transfer method radiography. The results show for the first time that the combination of dysprosium with a scintillation material like ZnS can produce light which is measurable under common camera-based detection conditions and that neutron radiographic images of reasonable quality can be produced. The resolution was poorer than expected at ~ 300 µm, but is on the order of the desired resolution of 100 µm. Potential improvements and additional converter materials may be investigated in the future that could increase the light output and improve spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Toward Trustworthy Detectors Detector Characterization for SuperCDMS SNOLAB Commissioning

SuperCDMS SNOLAB is a next generation direct detection experiment searching for low mass dark matter using cryogenic germanium and silicon detectors operated at millikelvin temperatures. As commissioning begins, establishing stable, predictable detector response to energy deposits is a prerequisite for future physics analysis. This work studies detector stability and calibration for four SuperCDMS SNOLAB detectors, det 7 and det 15 (germanium) and det 11 and det 14 (silicon), using Barium-133 calibration data (356 keV gamma ray reference) and low background data (ambient radiation, no external source). The Ba-133 data show no distinct line at the expected energy, and the low background data show a baseline that drifts and oscillates rather than remaining flat, consistently across multiple channels, suggesting a shared, detector wide cause. These observations point to the cryogenic support system as the likely source, since small temperature fluctuations could couple into the temperature sensitive detectors, informing the ongoing commissioning effort.

O'Hanlon, Vika [Skidmore Coll.]↗

Constraints on the Electromagnetic Counterpart of the Neutron-star–Black-hole Merger GW200115

We report the results of our follow-up campaign for the neutron-star—black-hole (NSBH) merger GW200115 detected during the O3 run of the Advanced LIGO and Advanced Virgo detectors. We obtained wide-field observations with the Deca-Degree Optical Transient Imager covering ~20% of the total probability area down to a limiting magnitude of w = 20.5 AB at ~23 hr after the merger. Our search for counterparts returns a single candidate (AT2020aeo), likely not associated with the merger. In total, only 25 sources of interest were identified by the community and later discarded as unrelated to the GW event. We compare our upper limits with the emission predicted by state-of-the-art kilonova simulations and disfavor high-mass ejecta (>0.1 M⊙), indicating that the spin of the system is not particularly high. By combining our optical limits with gamma-ray constraints from Swift and Fermi, we disfavor the presence of a standard short-duration burst for viewing angles ≲15° from the jet axis. Our conclusions are, however, limited by the large localization region of this GW event, and accurate prompt positions remain crucial to improving the efficiency of follow-up efforts.

79 ASTRONOMY AND ASTROPHYSICS↗

MeV–GeV Gamma-Ray Emission from SNR G327.1–1.1 Discovered by the Fermi-LAT

Abstract We report the discovery of MeV–GeV γ -ray emission by the Fermi-LAT positionally coincident with the TeV pulsar wind nebula (PWN) HESS J1554–550 within the host supernova remnant (SNR) G327.1–1.1. The γ -ray emission is point-like and faint but significant (>4 σ ) in the 300 MeV–2 TeV energy range. We report here the Fermi-LAT analysis of the observed γ -ray emission followed by a detailed multiwavelength investigation to understand the nature of the emission. The central pulsar powering the PWN within G327.1–1.1 has not been detected in any wave band; however, it is likely embedded within the X-ray nebula, which is displaced from the center of the radio nebula. The γ -ray emission is faint and therefore a pulsation search to determine if the pulsar may be contributing is not feasible. Prior detailed multiwavelength reports revealed an SNR system that is old, τ ∼ 18,000 yr, where the interaction of the reverse shock with the PWN is underway or has recently occurred. We find that the γ -ray emission agrees remarkably well with a detailed broadband model constructed in a prior report based on independent hydrodynamical and semianalytic simulations of an evolved PWN. We further investigate the physical implications of the model for the PWN evolutionary stage incorporating the new Fermi-LAT data and attempt to model the distinct particle components based on a spatial separation analysis of the displaced PWN counterparts.

79 ASTRONOMY AND ASTROPHYSICS↗

Mixed-Material Scintillators (MMSS Quarterly Report FY20Q2)

This project aims to invent, model, and prototype mixed-material scintillator systems (MMSSs), a new class of radiation detectors that use heterogenous internal structures of different scintillating materials to detect additional properties of radiation. These internal structures can be produced using additive manufacture (3D printing) of scintillator, a currently emerging application of additive manufacture technology. MMSSs combine the low cost and complexity of conventional scintillation detectors with capabilities currently only available in more expensive and complex detectors. By identifying promising MMSS designs, this project will enable a new class of detectors to meet DNN’s mission needs for SNM detection. This quarter, we delivered one the MMSS Particle-ID Modeling report, a major deliverable of this project. This report describes our results on simulations of the particle-ID (PID) class of detectors. We found that these detectors outperform competing approaches for neutron-gamma discrimination, neutron source pointing, and neutron spectroscopy. Further highlights of the report are described below. During this quarter, We alerted HQ to a change in schedule for the remaining simulations planned for this project: we plan to put off further simulation and reporting of the position-resolving (PR) detector class until July. This change in schedule has allowed us to go into additional detail in the PID work that is both very promising and motivates our upcoming proposal. The other active task in this project is prototyping 3D-printed scintillators with the aim of realizing the designs we’ve simulated. On that front, we had three focuses: measuring the light output, increasing the size of printed parts, and combining blue and green scintillators. We succeeded in measuring the light output, showing an output of 30% of commercial standard. This result leaves room for improvement but is within striking distance of where we need to be. We were on track to demonstrate a key requirement for increasing the size of parts and also to show combined green/blue prints before the laboratory moved to a Minimum Safe (MinSafe) Operations posture as a result of local Shelter In Place orders due to Covid-19.

42 ENGINEERING↗

How Bright in Gravitational Waves are Millisecond Pulsars for the Galactic Center GeV Gamma-Ray Excess? A Systematic Study

The existence of dark matter (DM) is supported by various macroscopic observations, but its microscopic nature remains elusive. The Galactic Center GeV gamma-ray excess (GCE) has been a leading candidate signal for particle dark matter annihilation. However, an unresolved population of millisecond pulsars (MSPs) in the bulge provides the alternative explanation for the excess. Identifying these MSPs in electromagnetic bands is difficult due to source confusion, pulse broadening, and extinction. Gravitational waves (GWs) provide a complementary probe: a steadily rotating, non-axisymmetric MSP emits a nearly monochromatic GW signal in the sensitive band of ground-based detectors, with amplitude set by its ellipticity. In this work, we systematically investigate the GW emission from the MSP population proposed to explain the GCE and its detectability with current and future detectors. We consider three major scenarios for the origin of ellipticity and model the population properties of these MSPs. We also consider both isolated MSPs and MSPs in binary systems, as well as Doppler effects in the detection. We find that while the signal is below the reach of current interferometers, next-generation detectors such as the Einstein Telescope (ET) and Cosmic Explorer (CE) can detect a fraction of those MSPs, offering a novel test of the MSP interpretation of the GCE. Future directed searches toward the Galactic Center with continued improvements in sensitivities will either uncover this long-sought MSP population or place stringent limits on their ellipticities and abundance, with important implications for both the astrophysical and dark-matter interpretations of the GCE.

Lei, Ming-Yu [Purple Mountain Observ.; USTC, Hefei↗

Spherical time-encoded radiation imaging simulations

Radiation source localization is important for nuclear nonproliferation and can be obtained using time-encoded imaging systems with unsegmented detectors. A scintillation crystal can be used with a moving coded-aperture mask to vary the detected count rate produced from radiation sources in the far field. The modulation of observed counts over time can be used to reconstruct an image with the known coded-aperture mask pattern. Current time-encoded imaging systems incorporate cylindrical coded-aperture masks and have limits to their fully coded imaging field-of-view. This work focuses on expanding the field-of-view to 4π by using a novel spherical coded-aperture mask. A regular icosahedron is used to approximate a spherical mask. This icosahedron consists of 20 equilateral triangles; the faces of which are each subdivided into four equilateral triangle-shaped voxels which are then projected onto a spherical surface, creating an 80-voxel coded-aperture mask. Furthermore, these polygonal voxels can be made from high-Z materials for gamma-ray modulation and/or low-Z materials for neutron modulation. In this work, we present Monte Carlo N-Particle (MCNP) simulations and simple models programmed in Mathematica to explore image reconstruction capabilities of this 80-voxel coded-aperture mask.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal aging effects on crosslinked polyethylene cable insulation with decabromodiphenyl ether flame retardant alternative

Decabromodiphenyl ether (decaBDE) has been extensively used as a flame retardant in several applications, including nuclear electrical cable insulation. However, decaBDE has been identified as a persistent, bioaccumulative and toxic (PBT) substance, leading to regulatory scrutiny. The Environmental Protection Agency (EPA) published a regulation on January 6, 2021, aimed at phasing out the manufacturing, processing, and distribution of decaBDE. This rule set a compliance deadline of March 8, 2021, for the manufacture and processing of decaBDE, and an extended deadline of January 6, 2023, for specific applications including wire and cable insulation in nuclear power generation facilities. In response to such regulations, RSCC, a major supplier of safety-related electrical cables and associated products to the U.S. nuclear industry updated the formula of their crosslinked polyethylene (XLPE) insulation to replace the historically used decaBDE flame retardant with an acceptable alternative. This change from the previous decaBDE-containing XLPE prompted interest in comparative performance of the two material formulations, especially with respect to characteristics relevant to safety-related function such as thermal and radiation resistance. RSCC graciously provided samples of wire insulated with the decaBDE-containing XLPE formulation and corresponding wire insulated with XLPE of the new formulation, containing a decaBDE alternative. In this work we compare characteristics of the two formulations and a previously produced commercial version of the RSCC decaBDE-containing XLPE insulation subjected to thermal aging at 150 °C and 165 °C. The comparison was focused on mechanical durability, thermal stability in the oxidative environment, and chemical structures. Briefly, • Tensile elongation at break (EAB) results showed loss of mechanical elasticity with longer aging time, as expected. Aging time dependence of EAB did not differ between the decaBDE-containing and decaBDE-alternative samples. • Subtle differences between the two materials can be detected from Fourier-transform infrared spectroscopy (FTIR) absorbance spectra in the range below 1700 cm -1 , are assumed to be related to decomposition of flame retardant additives during thermal aging. • The oxidation induction time (OIT) data seemed to show that the unaged decaBDE-containing XLPE material is more thermally stable than the unaged decaBDE-alternative material, but the discrepancy in OIT decreased with aging time and the OIT values of the two materials became similar starting with the 4 th day of aging at 165 °C. This thermal aging investigation confirmed that the mechanical durability, a key property monitored for cable qualification, was not significantly affected by the modification of the formulation with a decaBDE alternative flame-retardant system in the investigated thermal aging conditions. Further studies on the same sets of materials exposed to thermal and gamma radiation aging would further inform comparison of the materials safety-related function.

36 MATERIALS SCIENCE↗

Milky Way white dwarfs as sub-GeV to multi-TeV dark matter detectors

Here, we show that Milky Way white dwarfs are excellent targets for dark matter (DM) detection. Using Fermi and H.E.S.S. Galactic center gamma-ray data, we investigate sensitivity to DM annihilating within white dwarfs into long-lived or boosted mediators and producing detectable gamma rays. Depending on the Galactic DM distribution, we set new constraints on the spin-independent scattering cross section down to 10 -45 -10 -41 cm 2 in the sub-GeV DM mass range, which is multiple orders of magnitude stronger than existing limits. For a generalized NFW DM profile, we find that our white dwarf constraints exceed spin-independent direct detection limits across most of the sub-GeV to multi-TeV DM mass range, achieving sensitivities as low as about 10 -46 cm 2 . In addition, we improve earlier versions of the DM capture calculation in white dwarfs, by including the low-temperature distribution of nuclei when the white dwarf approaches crystallization. This yields smaller capture rates than previously calculated by a factor of a few up to two orders of magnitude, depending on white dwarf size and the astrophysical system.

79 ASTRONOMY AND ASTROPHYSICS↗

Rapid neutron and gamma-ray source localization using machine learning

Rapid localization of radiation sources is critical for applications including nuclear emergency response, safeguards, and security. However, conventional imaging systems such as neutron scatter cameras and Compton cameras depend on rare coincidence events, which often result in long acquisition times. In this work, we address the challenge of rapid source localization by developing a machine learning approach to predict the direction of a single radiation source using only count rates from an array of neutron and gamma-ray detectors. The proposed model is a fully connected neural network (FCNN) trained using Monte Carlo simulation data from a 252 Cf source. The model hyperparameters are optimized with a small set of routine 252 Cf measurements. We benchmarked the performance of the trained and optimized machine learning model using additional 252 Cf , 137 Cs , and PuBe measurements under laboratory conditions with varying source-detector configurations. For these measurements, the machine learning model achieved a mean localization error smaller than 30° with 3 x 10 3 system counts, corresponding to 8 s measurement time for the imaging system used in this work. In this low-statistics regime, the method outperformed traditional scatter-based imaging by more than 75% in localization accuracy for the evaluated measurement configurations. These results demonstrate that a machine learning-based approach can significantly reduce the time required for accurate single-source localization, providing a robust and computationally efficient alternative to traditional imaging systems in time-critical nuclear security and emergency response scenarios.

Gamma-ray imaging↗

Correlations Between Panoramic Imagery and Gamma-Ray Background in an Urban Area

When searching for radiological sources in an urban area, a vehicle-borne detector system will often measure complex, varying backgrounds primarily from natural gamma-ray sources. Much work has been focused on developing spectral algorithms that retain sensitivity and minimize the false-positive rate even in the presence of such spectral and temporal variability. However, information about the environment surrounding the detector system might also provide useful clues about the expected background, which if incorporated into an algorithm, could improve performance. Recent work has focused on extensive measuring and modeling of urban areas with the goal of understanding how these complex backgrounds arise. This work presents an analysis of panoramic video images and gamma-ray background data collected in Oakland, California, by the radiological multisensor analysis platform (RadMAP) vehicle. Features were extracted from the panoramic images by semantically labeling the images and then convolving the labeled regions with the detector response. A linear model was used to relate the image-derived features to gamma-ray spectral features obtained using nonnegative matrix factorization (NMF) under different regularizations. Here we find some gamma-ray background features correlate strongly with image-derived features that measure the response-adjusted solid angle subtended by sky and buildings, and we discuss the implications for the development of future, contextually aware detection algorithms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deep Search for Gamma-Ray Emission from the Accreting X-Ray Pulsar 1A 0535+262

Binary systems are a well-established subclass of gamma-ray sources. The high mass X-ray binary pulsar 1A 0535+262 has been considered to be a possible gamma-ray emitter for a long time, although former gamma-ray searches using the Fermi Large Area Telescope (LAT) and VERITAS data resulted in upper limits only. We aim at a deep search for gamma-ray emission and pulsations from 1A 0535+262 using more than 13 yr of Fermi-LAT data. The analysis was performed for both the whole Fermi-LAT data set, as well as for the X-ray outbursts that 1A 0535+262 has experienced since the launch of Fermi. Various X-ray observations have been used to generate the ephemeris for the pulsation search. We also investigate the long-term gamma-ray flux variability and perform orbital phase-resolved analysis for the outbursts. We did not detect any steady or pulsed gamma-ray emission from 1A 0535+262 during the whole Fermi-LAT mission span or its X-ray outbursts. We thus derived the deepest gamma-ray luminosity upper limits to date at the 95% confidence level to be around (2.3–4.7) × 10 32 erg s -1 depending on different spectral indices assumed, which results in a ratio of L γ to L X (2–150 keV) being (1.9–3.9) × 10 -6 .

79 ASTRONOMY AND ASTROPHYSICS↗

Mitigation of Cosmic Rays-Induced Errors in Superconducting Quantum Processors

Environmental radioactivity and cosmic-rays have recently been identified as a source of decoherence in super-conducting quantum bits (qubits). In particular, the absorption of cosmic-ray muons and gamma rays emitted by naturally occurring radioactive isotopes in the qubit substrate leads to correlated errors in superconducting quantum processors, posing significant challenges to quantum error correction. To enable quantum computing to scale, it is therefore necessary the devel-opment of mitigation strategies to prevent, or keep under control, error bursts due to particle impacts in the chip. While most environmental radioactive sources can be effectively suppressed using dedicated shielding, cosmic-ray muons, with their high penetration capability, can only be mitigated by moving the entire facility in a deep underground laboratory. This work explores the potential for developing a novel class of quantum processors equipped with an active veto system to protect superconducting-based quantum computers from the detrimental effects of atmospheric muons. Such a device would enable the identification of an atmospheric muon interaction within the processor and veto all operations performed during the occurrence of such an interaction. By demonstrating high detection efficiency and negligible dead time, we aim to establish that the future of quantum processors can be envisioned in above-around facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Analysis and Support for LANL Technology Testbed: High Altitude Balloon Gondola and Orion Eagle Gamma Ray Detection Instrument

The Analysis and Support for LANL Technology Testbed: High Altitude Balloon Gondola and Orion Eagle Gamma-Ray Detection Instrument is a project where Los Alamos National Laboratory (LANL), in conjunction with the University of Michigan, are looking into gamma-ray detection in a space-like environment. The purpose of the detection is to work on instruments that can assist with planetary exploration and nuclear deterrents using a High-Altitude Balloon (HAB). For this paper, the main focus is on the mechanical aspects related to the structural analysis of the gondola. It is vital to understand the structural analysis because it helps determine if the gondola can survive the changes in the environment and the different forces or shocks that it will experience when the parachute is deployed and at landing. Additionally, NASA's Balloon Program Office (BPO) has specific requirements to meet to achieve flight certifications. Part of those certifications requires the gondola to simulate different scenarios at specific conditions with various forces applied and orientations. Therefore, it is necessary to adjust the calculations of each method and the force applied to get the right results. Once that is done, the information is inputted into the structural analysis modeling system. The system will aid the mechanical team in assessing the conditions of the gondola at each scenario and determine its margin of safety. After the gondola and instrument are certified, the payload will be able to fly. The HAB and payload are launched from NASA's Columbia Scientific Balloon Facility (CSBF) at Fort Sumner, NM. The official flight was on September 26th, 2021.

42 ENGINEERING↗

Picosecond measurements of plastic scintillator pulse shapes from gamma-ray interactions

An understanding of the pulse shape of organic scintillators can provide insight into scintillation mechanisms and inform the selection of the optimal detector material for a given application. Although the timing properties of organic scintillators have been extensively studied, significant discrepancies persist in reported rise and decay times. New plastic scintillating media have also been developed in recent years for which no literature data exist. The goal of this work is to provide high-precision measurements of the pulse shape of a suite of fast plastic organic scintillators from Eljen Technology—EJ-200, EJ-204, EJ-208, EJ-230, EJ-232, and EJ-232Q (with 0.5% benzophenone)—under excitation from $γ$-ray sources. The contributors to the system temporal resolution were quantified, and the dominant source of uncertainty was identified as the determination of the start time of a scintillation event. A pulse shape model was applied to the reconstructed temporal distributions, and rise and decay times were extracted and compared with manufacturer specifications. This work outlines a measurement approach to obtain the pulse shape of organic scintillators in response to $γ$-rays with temporal resolution on the order of tens of picoseconds, yielding data required for modeling plastic scintillator based detection systems for a range of applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗