Experimental system for studying temperature gradient-driven fracture of oxide nuclear fuel out of reactor

Temperature gradients in ceramic light water reactor (LWR) uranium dioxide (UO 2 ) nuclear fuel pellets generate thermal stresses that cause fractures in the fuel beginning early in the life of fresh fuel. The combination of heating due to fission and forced convective cooling on the exterior of LWR fuel rods generates a temperature profile that is difficult to replicate outside the reactor environment. In the present study, a state-of-the-art experimental set-up using electrical heating to replicate fission heating was built and surrogate fuel materials such as ceria (CeO 2 ) were used to validate the system. Cracking experiments were conducted on these surrogates by inducing reactivity-initiated-accident (RIA) like temperature gradients in the pellets via induction and direct resistance heating. Induction heating was done using copper coils and molybdenum susceptors which heated the surrogates to a threshold temperature that is sufficiently high for the fuel material to conduct current. Thereafter, direct resistance heating was used by a D.C. power supply to introduce volumetric heating to replicate LWR operating conditions analogous to fission heating. The pellets were held against nickel electrodes and mounted on a boron nitride test-stand. All the tests were carried out in a stainless-steel vacuum chamber. Simultaneous real-time dual imaging of the surrogate pellet surface has been implemented using an optical and infrared camera system which will be mounted along axial and perpendicular directions to the pellet surface respectively. A beam-splitter was used to split the incoming radiation from the sample into two halves. While one of the beams is transmitted from the splitter through a bandpass filter to obtain optical images, the other beam is reflected from the splitter to the thermal camera to capture full field temperature gradients of the as fabricated pellet surface during crack initiation and propagation. In the current series of tests, a 2-color pyrometer was used for recording and comparing the surface and centerline temperatures of the surrogate pellets in lieu of the thermal camera. A LabVIEW data acquisition system has been set up for collecting useful data during experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The second filter’s second coming

We measured sound-evoked vibrations at the stereociliary side of inner and outer hair cells and their surrounding supporting cells, using optical coherence tomography interferometry in living anesthetized guinea pigs. Our measurements demonstrate a gradient in frequency tuning among different cell types, going from a high best frequency at the inner hair cells to a lower one at the Hensen cells. This causes the locus of maximum inner hair cell activation to be shifted toward the apex of the cochlea as compared to the outer hair cells. These observations show that additional processing and filtering of acoustic signals occurs within the organ of Corti prior to inner hair cell excitation, thus reinstating a transformed second filter as a mechanism contributing to cochlear frequency tuning.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Testing Fast Reactor Fuels in a Thermal Reactor: A Comparison Report

The testing of fast reactor fuels in the thermal-spectrum of the Advanced Test Reactor using cadmium-filtering has been underway since 2003. The objective of this experimental approach to create a temperature profile inside of test fuel rodlets that is nearly prototypic of corresponding fast reactor conditions. This requires, necessarily, that the power generation profile inside of test fuel rodlets also be nearly prototypic of corresponding fast reactor conditions. By doing so, this experimental approach should allow for the study of fast reactor fuel performance phenomena that are primarily dependent upon the conditions of temperature and/or temperature gradient inside the fuel to be possible using a thermal test reactor. Validation of this assertion has been undertaken by both supporting analyses and by comparing fuel performance phenomena observed in fuels irradiated in cadmium-filtered positions in ATR to similar or identical fuels irradiated under similar conditions in genuine fast reactors. This report documents a preliminary comparison of fuel performance data available from the testing of metallic, oxide, and nitride fuels in cadmium-filtered positions in the ATR to the performance of identical or similar fuels irradiated in genuine fast reactors. Although a variety of fuel performance metrics are presented, particular attention is paid to those phenomena that are primarily, or significantly, dependent on conditions of temperature and temperature gradient with the fuel. Although the comparisons presented in this report are at this time limited in scope and preliminary in nature, they do support the assertion that the objectives of the cadmium-filtered testing approach in ATR are both feasible and appear sound. The analyses and comparisons presented in this report show that ATR irradiations performed using cadmium shrouding are sufficiently prototypic that they can be used with confidence in the development and testing of fast reactor fuels.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Electron energy distribution function and plasma parameters across magnetic filters

The electron energy distribution function (EEDF) is measured across a magnetic filter in inductively coupled plasmas. The measured EEDFs are found to be Maxwellian in the elastic energy range with the corresponding electron temperature monotonously decreasing along the positive gradient of the magnetic field. At the maximum of the magnetic field, the electron temperature reaches its minimum and remains nearly constant in the area of the negative gradient of the field, where the plasma density distribution exhibits a local minimum.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ENHANCING CORONAL STRUCTURES WITH THE FOURIER NORMALIZING-RADIAL-GRADED FILTER

Images of the corona have a high dynamic range which is excellent for quantitative photometric analysis. To understand the processes governing the solar corona, it is essential to have information about the absolute brightness as well as the underlying structure. However, due to the steep radial gradient of brightness in the images, and to the fact that structures closer to the solar disk have higher contrast than structures further from the disk, human vision cannot view the intricate structure of the corona in such images. The recently developed normalizing-radial-graded filter (NRGF) is an effective way for revealing the coronal structure. In this work, we present a more adaptive filter inspired by the NRGF, which we call the Fourier normalizing-radial-graded filter (FNRGF). It approximates the local average and the local standard deviation by a finite Fourier series. This method enables the enhancement of finer details, especially in regions of lower contrast. We also show how the influence of additive noise is reduced by a modification to the FNRGF. To illustrate the power of the method, the FNRGF is applied to images of emission from coronal forbidden lines observed during the 2010 July 11 total solar eclipse. It is also successfully applied to space-based observations of the low corona in the extreme ultraviolet and to white light coronagraph observations, thus demonstrating the validity of the FNRGF as a new tool that will help the interpretation of the information embedded in most types of coronal images.

79 ASTRONOMY AND ASTROPHYSICS↗

Electrically tunable spin filtering for electron tunneling between spin-resolved quantum Hall edge states and a quantum dot

Spin filtering with electrically tunable efficiency is achieved for electron tunneling between a quantum dot and spin-resolved quantum Hall edge states by locally gating the two-dimensional electron gas (2DEG) leads near the tunnel junction to the dot. The local gating can change the potential gradient in the 2DEG and consequently the edge state separation. We use this technique to electrically control the ratio of the dot–edge state tunnel coupling between opposite spins and finally increase spin filtering efficiency up to 91%, the highest ever reported, by optimizing the local gating.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Differences in urban plant community compositions across an urban-rural gradient in Knoxville, TN

Urban forests, or vegetation in areas under heavy human influence, provide many ecosystem services to urban residents such as localized cooling via evapotranspiration, shade, filtering of air pollution, and the associated health benefits of natural spaces. In order to quantify the magnitude of localized cooling by trees growing in varying levels of urbanization (based on % impervious surfaces, e.g., buildings, pavement), urban forest species composition, tree size, and tree density must be characterized. As a part of Oak Ridge National Laboratory’s (ORNL) urban forest temperature study, we conducted tree censuses in five Knoxville city parks where ORNL meteorological stations are deployed. Moreover, we measured every woody plant ≥ 5 cm diameter at breast height (DBH) within a 50 m radius of each site’s meteorological station for its DBH and species identification. When possible, individuals were identified down to species. Certain genera (Quercus spp., Carya spp., Pinus spp.) were identified down to genera in interest of time. Individual and total site basal area were calculated from measured DBH data. Results show notable differences in urban plant community compositions and total woody plant basal area across sites, with more urban sites closer to downtown (West View and SEEED) having lower tree basal area than the more suburban sites (West Hills, Cumberland Estates, and Victor Ashe). We identified 54 species across all sites, with West Hills and Victor Ashe having the highest species diversity. Our results show differences in forest compositions and sizes across Knoxville, which are currently informing ORNL’s evapotranspiration estimates for each site. Data Summary: Census data for West Hills (WH), Cumberland Estates (CE), Victor Ashe (VA), West View (WV), and Socially Equal Energy Efficient Development or SEEED (SD) urban forests in Knoxville, TN, USA, including tree size based on diameter at breast height (DBH; 1.3 m), species identification (Latin and common names), and basal area per stem (BA=π×[.5*DBH]^2). Field data are summarized in this file: “Community_Composition_Data.CSV”. Site-specific data detailing each site’s coordinates, number of stems measured at DBH, average tree DBH, α-diversity (number of species present), and total site basal area (sum of individual basal areas per site) are in this file: “Site_Comparisons.CSV”.

Warren, Jeffrey [ORNL] (ORCID:0000000206804697)↗

Potential High Resolution Dosimeters For MRT

Microbeam Radiation Therapy (MRT) uses highly collimated, quasi-parallel arrays of X-ray microbeams of 50-600 keV, produced by 2nd and 3rd generation synchrotron sources, such as the National Synchrotron Light Source (NSLS) in the U.S., and the European Synchrotron Radiation Facility (ESRF) in France, respectively. High dose rates are necessary to deliver therapeutic doses in microscopic volumes, to avoid spreading of the microbeams by cardiosynchronous movement of the tissues. A small beam divergence and a filtered white beam spectrum in the energy range between 30 and 250 keV results in the advantage of steep dose gradients with a sharper penumbra than that produced in conventional radiotherapy. MRT research over the past 20 years has allowed a vast number of results from preclinical trials on different animal models, including mice, rats, piglets and rabbits. Microbeams in the range between 10 and 100 micron width show an unprecedented sparing of normal radiosensitive tissues as well as preferential damage to malignant tumor tissues. Typically, MRT uses arrays of narrow ({approx}25-100 micron-wide) microplanar beams separated by wider (100-400 microns centre-to-centre, c-t-c) microplanar spaces. We note that thicker microbeams of 0.1-0.68 mm used by investigators at the NSLS are still called microbeams, although some invesigators in the community prefer to call them minibeams. This report, however, limits it discussion to 25-100 {mu}m microbeams. Peak entrance doses of several hundreds of Gy are surprisingly well tolerated by normal tissues. High resolution dosimetry has been developed over the last two decades, but typical dose ranges are adapted to dose delivery in conventional Radiation Therapy (RT). Spatial resolution in the sub-millimetric range has been achieved, which is currently required for quality assurance measurements in Gamma-knife RT. Most typical commercially available detectors are not suitable for MRT applications at a dose rate of 16000 Gy/s, micron resolution and a dose range over several orders of magnitude. This paper will give an overview of all dosimeters tested in the past at the ESRF with their advantages and drawbacks. These detectors comprise: Ionization chambers, Alanine Dosimeters, MOSFET detectors, Gafchromic registered films, Radiochromic polymers, TLDs, Polymer gels, Fluorescent Nuclear Track Detectors (Al{sub 2}O{sub 3}:C, Mg single crystal detectors), OSL detectors and Floating Gate-based dosimetry system. The aim of such a comparison shall help with a decision on which of these approaches is most suitable for high resolution dose measurements in MRT. The principle of these detectors will be presented including a comparison for some dosimeters exposed with the same irradiation geometry, namely a 1x1 cm{sup 5} field size with microbeam exposures at the surface, 0.1 cm and 1 cm in depth of a PMMA phantom. For these test exposures, the most relevant irradiation parameters for future clinical trials have been chosen: 50 micron FWHM and 400 micron c-t-c distance. The experimental data are compared with Monte Carlo calculations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Estimating scalar turbulent fluxes with slow-response sensors in the stable atmospheric boundary layer

Conventional and recently developed approaches for estimating turbulent scalar fluxes under stable atmospheric conditions are evaluated, with a focus on gases for which fast sensors are not readily available. First, the relaxed eddy accumulation (REA) classical approach and a recently proposed mixing length parameterization, labeled A22, are tested against eddy-covariance computations. Using high-frequency measurements collected from two contrasting sites (the frozen tundra near Utqiaġvik, Alaska, and a sparsely vegetated grassland in Wendell, Idaho, during winter), it is shown that the REA and A22 models outperform the conventional Monin–Obukhov similarity theory (MOST) utilized widely to infer fluxes from mean gradients. Second, scenarios where slow trace gas sensors are the only viable option in field measurements are investigated using digital filtering applied to fast-response sensors to simulate their slow-response counterparts. With a filtered scalar signal, the observed filtered eddy-covariance fluxes are referred to here as large-eddy-covariance (LEC) fluxes. A virtual eddy accumulation (VEA) approach, akin to the REA model but not requiring a mechanical apparatus to separate the gas flows, is also formulated and tested. A22 outperforms VEA and LEC in predicting the observed unfiltered (total) eddy-covariance (EC) fluxes; however, VEA can still capture the LEC fluxes well. This finding motivates the introduction of a sensor response time correction into the VEA formulation to offset the effect of sensor filtering on the underestimated net averaged fluxes. The only needed parameter for this correction is the mean velocity at the instrument height, a surrogate of the advective timescale. The VEA approach is very suitable and simple to use with gas sensors of intermediate speed (∼ 0.5 to 1 Hz) and with conventional open- or closed-path setups.

58 GEOSCIENCES↗

Comparison of Several Numerical Methods for Simulation of Compressible Shear Layers

An investigation is conducted on several numerical schemes for use in the computation of two-dimensional, spatially evolving, laminar variable-density compressible shear layers. Schemes with various temporal accuracies and arbitrary spatial accuracy for both inviscid and viscous terms are presented and analyzed. All integration schemes use explicit or compact finite-difference derivative operators. Three classes of schemes are considered: an extension of MacCormack's original second-order temporally accurate method, a new third-order variant of the schemes proposed by Rusanov and by Kutier, Lomax, and Warming (RKLW), and third- and fourth-order Runge-Kutta schemes. In each scheme, stability and formal accuracy are considered for the interior operators on the convection-diffusion equation U(sub t) + aU(sub x) = alpha U(sub xx). Accuracy is also verified on the nonlinear problem, U(sub t) + F(sub x) = 0. Numerical treatments of various orders of accuracy are chosen and evaluated for asymptotic stability. Formally accurate boundary conditions are derived for several sixth- and eighth-order central-difference schemes. Damping of high wave-number data is accomplished with explicit filters of arbitrary order. Several schemes are used to compute variable-density compressible shear layers, where regions of large gradients exist.

Kennedy, Christopher A.↗

Prostate Localization on Daily Cone-Beam Computed Tomography Images: Accuracy Assessment of Similarity Metrics

Purpose: To evaluate different similarity metrics (SM) using natural calcifications and observation-based measures to determine the most accurate prostate and seminal vesicle localization on daily cone-beam CT (CBCT) images. Methods and Materials: CBCT images of 29 patients were retrospectively analyzed; 14 patients with prostate calcifications (calcification data set) and 15 patients without calcifications (no-calcification data set). Three groups of test registrations were performed. Test 1: 70 CT/CBCT pairs from calcification dataset were registered using 17 SMs (6,580 registrations) and compared using the calcification mismatch error as an endpoint. Test 2: Using the four best SMs from Test 1, 75 CT/CBCT pairs in the no-calcification data set were registered (300 registrations). Accuracy of contour overlays was ranked visually. Test 3: For the best SM from Tests 1 and 2, accuracy was estimated using 356 CT/CBCT registrations. Additionally, target expansion margins were investigated for generating registration regions of interest. Results: Test 1-Incremental sign correlation (ISC), gradient correlation (GC), gradient difference (GD), and normalized cross correlation (NCC) showed the smallest errors ({mu} {+-} {sigma}: 1.6 {+-} 0.9 {approx} 2.9 {+-} 2.1 mm). Test 2-Two of the three reviewers ranked GC higher. Test 3-Using GC, 96% of registrations showed <3-mm error when calcifications were filtered. Errors were left/right: 0.1 {+-} 0.5mm, anterior/posterior: 0.8 {+-} 1.0mm, and superior/inferior: 0.5 {+-} 1.1 mm. The existence of calcifications increased the success rate to 97%. Expansion margins of 4-10 mm were equally successful. Conclusion: Gradient-based SMs were most accurate. Estimated error was found to be <3 mm (1.1 mm SD) in 96% of the registrations. Results suggest that the contour expansion margin should be no less than 4 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gravity gradient measurements

It is shown that, for floated satellite gradiometers subject to very low levels of unmodeled forces and torques, dynamic estimation can dramatically reduce rotation correction errors. The filter structure is developed, and the value of factorization techniques is examined. Numerical examples are given for a few practical cases using plausible instrument ensembles. To achieve these early results, great simplifications have been made, and important error sources have been suppressed.

Sonnabend, D.↗

Determination of Total Magnetic Anomalies and Their Vertical Gradients of Swarm-A Satellite over Central Europe and Pannonian Basin

Our paper discusses the determination of total magnetic field anomalies derived from the Swarm–A satellite data; one of two low orbiting satellites of the three Swarm formations. This procedure requires several modifications. The first step is the conversion of the measured CDF data to the ASCII format. This step is followed by the selection of the data with K(sub p) index ≤ 1(sub +). The anomalies are determined by the removal of the IGRF from the resulting satellite data. There are two Swarm–A data sets: descending (6000) orbits and ascending (5688) orbits. For our study the descending orbits were used. The next step of calculations is to determine the difference of the two-dimensional linear field fitted to the Swarm–A anomalies and the anomalies given. These anomalies are filtered by Gaussian low-pass filter. The last step of the corrections is the removal of the direct component, zero spatial frequency, from the descending anomalies. The anomalies and their vertical gradients are qualitatively interpreted over Central Europe and the Pannonian Basin.

Kis, K.↗

Real-time breath analysis towards a healthy human breath profile

Abstract The direct analysis of molecules contained within human breath has had significant implications for clinical and diagnostic applications in recent decades. However, attempts to compare one study to another or to reproduce previous work are hampered by: variability between sampling methodologies, human phenotypic variability, complex interactions between compounds within breath, and confounding signals from comorbidities. Towards this end, we have endeavored to create an averaged healthy human ‘profile’ against which follow-on studies might be compared. Through the use of direct secondary electrospray ionization combined with a high-resolution mass spectrometry and in-house bioinformatics pipeline, we seek to curate an average healthy human profile for breath and use this model to distinguish differences inter- and intra-day for human volunteers. Breath samples were significantly different in PERMANOVA analysis and ANOSIM analysis based on Time of Day, Participant ID, Date of Sample, Sex of Participant, and Age of Participant ( p < 0.001). Optimal binning analysis identify strong associations between specific features and variables. These include 227 breath features identified as unique identifiers for 28 of the 31 participants. Four signals were identified to be strongly associated with female participants and one with male participants. A total of 37 signals were identified to be strongly associated with the time-of-day samples were taken. Threshold indicator taxa analysis indicated a shift in significant breath features across the age gradient of participants with peak disruption of breath metabolites occurring at around age 32. Forty-eight features were identified after filtering from which a healthy human breath profile for all participants was created.

60 APPLIED LIFE SCIENCES↗

An updated estimate of the Mu2e experiment sensitivity

The Mu2e experiment at Fermilab will search for the conversion of a negative muon into an electron inside the field of a nucleus. This process does not conserve charged-lepton flavour and is heavily suppressed in the Standard Model (SM), with a branching ratio < 10-50. Any evidence of it would be an undeniable evidence of new physics beyond the SM. The project sets out to achieve a single event sensitivity of $\sim 3 × 10^{-17}$ on the ratio between the probability for a conversion of a negative muon into an electron and the one for a muon capture by the nucleus. Such a sensitivity would represent a 4 orders of magnitude improvement on the previous upper limit for the process, making possible to test predictions of different extensions of the SM. Mu2e uses three superconducting solenoids to produce and measure the muon conversions. In the first solenoid, the Production Solenoid, pions and kaons are produced, together with other secondary products, by 8 GeV kinetic energy proton interactions in a tungsten target. A gradient magnetic field is specifically designed to direct low momentum particles into the Transport Solenoid, an S-shaped magnet that filters out particles with unwanted charge and momentum. Muons, produced by pion and kaon decays, finally reach the aluminum Stopping Target in the Detector Solenoid, where they eventually stop and convert. The result of the conversion process is a monochromatic electron of ~105 MeV/c momentum. The Detector Solenoid also hosts the two main detectors: a straw tube tracker and two CsI calorimeter disks, both providing measurement of event kinematics. A germanium detector and a LaBr crystal are located downstream of the Detector Solenoid to measure the X and gamma rays produced by the muon captures in the Stopping Target. A veto system of scintillators covering the Detector Solenoid and half of the Transport Solenoid is used to identify and reject cosmic rays interactions. With respect to the initial project, the Mu2e running plan has evolved to a staged configuration with 2 years at reduced intensity before the 2025 accelerator shutdown for the neutrino beam upgrade and 2 or 3 years at full intensity after that. This, together with geometry changes and a better knowledge of detector performances obtained by the first slice tests, has required a full revision of the signal over background selection that is the subject of this thesis. In order to achieve a new estimate of Mu2e sensitivity, the simulation of the data corresponding to the first 2 years of data acquisition has been performed. This includes both conversion electrons (CE) and the main sources of background: cosmics, decay-in orbits (DIO), radiative pion captures (RPC) and antiprotons. The characteristics of the signal and of the main backgrounds have been studied to define the best selection variables for CE. A special effort has been devoted to the evaluation of the antiproton background. The lack of experimental data for antiproton production cross section makes the systematic uncertainty on this background significant. A new parameterization of the cross section has been developed to fit the existing data and to provide a more reliable estimate of the systematic uncertainty by comparing the results of the old and the new model. A special effort has been devoted to the optimization of the antiprotons Monte Carlo generator. This study has also revealed that the dominant component within this background is represented by antiprotons produced in the opposite direction with respect to the Transport Solenoid entrance and then redirected to it by back-scattering processes in the Production Target. This ultimately highlights the sensitivity of the background estimate to the G4 handling of antiproton interactions in the 1 to 3 GeV/c momentum range. Finally, the final experimental sensitivity has been studied. The momentum and time selection have been optimized to obtain the 5-sigma discovery reach or, in case of no signal, the upper limit on conversion probability. The results confirm that, in the firs t two years of data taking, Mu2e will be able to improve the current experimental sensitivity for muon-to-electron conversion in an atomic field by more than 3 order of magnitudes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Description and discussion of the NRL TGDCC

The NRL thermal gradient diffusion cloud chamber (TGDCC) consists of two plates 7.5 cm in diameter separated by 1.25 cm and covered with saturated filter paper. The cylindrical wall separating the plates is glass. The top plate is at room temperature and the bottom plate is cooled with a thermoelectric cooler. The temperature difference is measured with several sets of thermocouples. The CCN concentration was determined from the video recording. This procedure of averaging the maximum count obtained on several successive recordings at the same supersaturation results in concentrations which are somewhat higher than concentrations calculated from an average across the plateau.

Hoppel, W. A.↗

Toward a gradiometer analytic model

A new model is developed to model the data type, formulate the filter structure, and perform covariance for an orbiting gravity gradiometer, which is much more elaborate and realistic than the earlier gravity gradient model of Sonnabend and McEneaney (1988). The main new features of the new model are a general inertia tensor for the floated instrument, air drag and radiation pressure models using cubic power spectra, and more reasonable kinematics.

Sonnabend, Dave↗