Search NASA⌕ Search

SEARCH · Search NASA

Results for “guidelines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Countdown to perovskite space launch: Guidelines to performing relevant radiation-hardness experiments

Perovskite photovoltaics (PVs) are under intensive development for promise in terrestrial energy production. Soon, the community will find out how much of that promise may become reality. Perovskites also open new opportunities for lower cost space power. However, radiation tolerance of space environments requires appropriate analysis of relevant devices irradiated under representative radiation conditions. We present guidelines designed to rigorously test the radiation tolerance of perovskite PVs. We review radiation conditions in common orbits, calculate nonionizing and ionizing energy losses (NIEL and IEL) for perovskites, and prioritize proton radiation for effective nuclear interactions. Low-energy protons (0.05-0.15 MeV) create a representative uniform damage profile, whereas higher energy protons (commonly used in ground-based evaluation) require significantly higher fluence to accumulate the equivalent displacement damage dose due to lower scattering probability. Furthermore, high-energy protons may "heal" devices through increased electronic ionization. These procedural guidelines differ from those used to test conventional semiconductors.

14 SOLAR ENERGY↗

Siting guidelines for concentrating solar power plants in the Sahel: Case study of Burkina Faso

Selecting a site that meets the technical requirements for a concentrating solar power plant (CSP) is a very critical exercise. This paper points out crucial factors and provides guidelines regarding the selection of suitable sites. It especially focuses on Sahelian countries which have their own climatic peculiarities. These countries, characterized by low access to electricity, are well endowed in solar resources. They are potentially good locations for concentrating solar power plants since their mean daily solar radiation exceeds 5.5 kWh/m{sup 2}. CSP presents therefore, a good opportunity for them to increase in a sustainable manner, their energy supply. The guidelines developed in this paper are applied to Burkina Faso as a case study. (author)

14 SOLAR ENERGY↗

Field assessment of semi-aerobic condition and the methane correction factor for the semi-aerobic landfills provided by IPCC guidelines

Highlights: • CH{sub 4}/CO{sub 2} and CH{sub 4} + CO{sub 2}% are proposed as indices to evaluate semi-aerobic landfills. • A landfill which CH{sub 4}/CO{sub 2} > 1.0 is difficult to be categorized as semi-aerobic landfill. • Field conditions should be carefully investigated to determine landfill types. • The MCF default value for semi-aerobic landfills underestimates the methane emissions. - Abstract: According to IPCC guidelines, a semi-aerobic landfill site produces one-half of the amount of CH{sub 4} produced by an equally-sized anaerobic landfill site. Therefore categorizing the landfill type is important on greenhouse gas inventories. In order to assess semi-aerobic condition in the sites and the MCF value for semi-aerobic landfill, landfill gas has been measured from vent pipes in five semi-aerobically designed landfills in South Korea. All of the five sites satisfied requirements of semi-aerobic landfills in 2006 IPCC guidelines. However, the ends of leachate collection pipes which are main entrance of air in the semi-aerobic landfill were closed in all five sites. The CH{sub 4}/CO{sub 2} ratio in landfill gas, indicator of aerobic and anaerobic decomposition, ranged from 1.08 to 1.46 which is higher than the values (0.3–1.0) reported for semi-aerobic landfill sites and is rather close to those (1.0–2.0) for anaerobic landfill sites. The low CH{sub 4} + CO{sub 2}% in landfill gas implied air intrusion into the landfill. However, there was no evidence that air intrusion has caused by semi-aerobic design and operation. Therefore, the landfills investigated in this study are difficult to be classified as semi-aerobic landfills. Also MCF of 0.5 may significantly underestimate methane emissions compared to other researches. According to the carbon mass balance analyses, the higher MCF needs to be proposed for semi-aerobic landfills. Consequently, methane emission estimate should be based on field evaluation for the semi-aerobically designed landfills.

54 ENVIRONMENTAL SCIENCES↗

Guidelines for investigating causality of sequence variants in human disease

The discovery of rare genetic variants is accelerating, and clear guidelines for distinguishing disease-causing sequence variants from the many potentially functional variants present in any human genome are urgently needed. Without rigorous standards we risk an acceleration of false-positive reports of causality, which would impede the translation of genomic research findings into the clinical diagnostic setting and hinder biological understanding of disease. Here we discuss the key challenges of assessing sequence variants in human disease, integrating both gene-level and variant-level support for causality. We propose guidelines for summarizing confidence in variant pathogenicity and highlight several areas that require further resource development.

59 BASIC BIOLOGICAL SCIENCES↗

Guidelines for internal optics optimization of the ITER EC H and CD upper launcher

The importance of localized injection of Electron Cyclotron waves to control Magneto-HydroDynamic instability is well assessed in tokamak physics and the set of four Electron Cyclotron (EC) Upper Launchers (UL) in ITER is mainly designed for this purpose. Each of the 4 ULs uses quasi-optical mirrors (shaping and planes, fixed and steerable) to redirect and focus 8 beams (in two rows, with power close to 1 MW per beam coming from the EC transmission lines) in the plasma region where the instability appears. Small beam dimensions and maximum beam superposition guarantee the necessary localization of the driven current. To achieve the goal of MHD stabilization with minimum EC power to preserve the energy confinement in the outer half of the plasma cross section, optimization of the quasi-optical design is required and a guideline of a strategy is presented. As a result of this process and following the guidelines indicated, modifications of the design (new mirrors positions, rotation axes and/or focal properties) will be proposed for the next step of an iterative process, including the mandatory compatibility check with the mechanical constraints.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Guidelines for creating artificial neural network empirical interatomic potential from first-principles molecular dynamics data under specific conditions and its application to $α$-Ag 2 Se

First-principles molecular dynamics (FPMD) simulations are highly accurate, but due to their high calculation cost, the computational scale is often limited to hundreds of atoms and few picoseconds under specific temperature and pressure conditions. As such, we present here the guidelines for creating artificial neural network empirical interatomic potential (ANN potential) trained with such a limited FPMD data, which can perform long time scale MD simulations at least under the same conditions. The FPMD data for training are prepared on the basis of the convergence of radial distribution function [$g(r)$]. While training the ANN using total energy and atomic forces of the FPMD data, the error of pressure is also monitored and minimized. To create further robust potential, we add a small amount of FPMD data to reproduce the interaction between two atoms that are close to each other. ANN potentials for $α$-Ag 2 Se were created as an application example, and it has been confirmed that not only $g(r)$ and mean square displacements but also the specific heat requiring a long time scale simulation matched the FPMD and the experimental values. In addition, the MD simulation using the ANN potential achieved over 10 4 acceleration over the FPMD one. The guidelines proposed here mitigate the creation difficulty of the ANN potential, and a lot of FPMD data sleeping on the hard disk after the research may be put on the front stage again.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-P-38: Comparison of Capri Applicator HDR Planning Methods to Meet the NCCN Uterine Neoplasm 2.2015 Guidelines

Purpose: To establish a systematic planning approach for Capri intravaginal multichannel balloon applicators that meet updated Version 2.2015 NCCN guidelines for uterine neoplasms, which dictate delivery of 400 to 600 cGy in 2 to 3 fractions prescribed to the vaginal mucosa for HDR combined with EBRT as well as a regimen of 600 cGy x 5 (to the vaginal mucosa) for HDR brachytherapy alone. Methods: Studies have shown three different channel configurations of the Capri applicator are optimal for dosimetric conformity: central channel combined with the six inner ring channels (R12), all inner and outer ring channels (R23), or all thirteen channels (R123). To minimize the dose to the vaginal mucosa, a traditional 0.5cm expansion contour from the Capri surface was created. Optimization limits were set to push 600 cGy to 100% of the Capri volume, while simultaneously restricting dose to the expansion contour. Results: Plans were created using all three configurations (R12, R23, R123) and evaluated to determine which was best for delivering 600 cGy to the vaginal mucosa. Our criteria was: Capri V100 > 98%, Vaginal Mucosa Dmax < 125%, Bladder Dmax < 100%, Rectum Dmax < 100%. All configurations show Capri V100 values greater than 98.5%, with differences between plans varying by less than 1%. Vaginal mucosal Dmax values showed differences of roughly 5% of prescription. The R12 configuration proved the lowest vaginal mucosa Dmax, on average. The OAR Dmax values showed an average dose difference of roughly 2% of prescription, with the R23 configuration having the best results. Conclusion: The R12 channel configuration optimally fits our planning criteria and NCCN guidelines for 600 cGy prescribed to the vaginal mucosa. On average, it produced the highest Capri V100, the lowest vaginal mucosal Dmax, and a marginally higher OAR Dmax doses compared to the R23 and R123 plans.

60 APPLIED LIFE SCIENCES↗

SU-E-T-322: Dosimetric Evaluation of Rib Dose in Peripheral Lung Tumors Treated with X-Ray Voxel Monte Carlo (XVMC) Based Lung Stereotactic Body Radiotherapy (SBRT) Following RTOG 0915 Guidelines

Purpose: To evaluate XVMC computed rib doses for peripherally located non-small-cell-lung tumors treated with SBRT following RTOG-0915 guidelines. Methods: Twenty patients with solitary peripherally located non-small-cell-lung tumors were treated using XVMC-based SBRT to 50–54Gy in 5−3 fractions, respectively, for PTV(V100%)=95%. Based on 4D-CT, ITV was delineated on MaximumIP images and organs-at-risk(OARs) including ribs were contoured on MeanIP images. Mean PTV(ITV+5mm uniform margin) was 46.1±38.7cc (range, 11.1–163.0cc). XVMC SBRT treatment plans were generated with a combination of non-coplanar 3D-conformal arcs/beams, and were delivered by Novalis-TX consisting of HD-MLCs and a 6MV-SRS(1000MU/min) beam, following RTOG-0915 criteria. XVMC rib maximum dose and dose to <1cc, <5cc, <10cc were evaluated as a function of PTV, prescription dose and 3D-distance from tumor isocenter to the most proximal rib contour. Plans were re-computed using heterogeneity-corrected pencil-beam (PB-hete) algorithm utilizing identical beam geometry/MLC positions and MUs and subsequently compared to XVMC. Results: XVMC average maximum rib dose was 50.9±6.4Gy (range, 35.1–59.3Gy). XVMC mean rib dose to <1cc was 41.6±5.6Gy (range, 27.9–47.9Gy), <5cc was 31.2±7.3Gy (range, 10.6–43.1Gy), and <10cc was 21.2±8.7Gy (range, 1.1–36Gy), respectively. For the given prescription, correlation between PTV and rib doses to <5cc (p=0.005) and <10cc (p=0.018) was observed. 3D-distance from the tumor isocenter to the proximal rib contour strongly correlated with maximum rib dose (p=0.0001). PB-hete algorithm overestimated maximum rib dose and dose to <1cc, <5cc, and <10cc of ribs by 5%, 3%, 3%, and 3%, respectively. Conclusion: PB-hete overestimates ribs dose relative to XVMC. Since all the clinical XVMC plans were generated without compromising the target coverage (per RTOG-0915), almost all patient’s ribs doses were higher than the protocol guidelines. As expected, larger tumor size and proximity to ribs received higher absolute dose to ribs. Prospective observation is needed to determine if XVMC delivered rib doses correlates with patient symptoms including chest wall pain and/or rib fractures.

60 APPLIED LIFE SCIENCES↗

Guidelines by the AAPM and GEC-ESTRO on the use of innovative brachytherapy devices and applications: Report of Task Group 167

Although a multicenter, Phase III, prospective, randomized trial is the gold standard for evidence-based medicine, it is rarely used in the evaluation of innovative devices because of many practical and ethical reasons. It is usually sufficient to compare the dose distributions and dose rates for determining the equivalence of the innovative treatment modality to an existing one. Thus, quantitative evaluation of the dosimetric characteristics of innovative radiotherapy devices or applications is a critical part in which physicists should be actively involved. The physicist’s role, along with physician colleagues, in this process is highlighted for innovative brachytherapy devices and applications and includes evaluation of (1) dosimetric considerations for clinical implementation (including calibrations, dose calculations, and radiobiological aspects) to comply with existing societal dosimetric prerequisites for sources in routine clinical use, (2) risks and benefits from a regulatory and safety perspective, and (3) resource assessment and preparedness. Further, it is suggested that any developed calibration methods be traceable to a primary standards dosimetry laboratory (PSDL) such as the National Institute of Standards and Technology in the U.S. or to other PSDLs located elsewhere such as in Europe. Clinical users should follow standards as approved by their country’s regulatory agencies that approved such a brachytherapy device. Integration of this system into the medical source calibration infrastructure of secondary standard dosimetry laboratories such as the Accredited Dosimetry Calibration Laboratories in the U.S. is encouraged before a source is introduced into widespread routine clinical use. The American Association of Physicists in Medicine and the Groupe Européen de Curiethérapie-European Society for Radiotherapy and Oncology (GEC-ESTRO) have developed guidelines for the safe and consistent application of brachytherapy using innovative devices and applications. The current report covers regulatory approvals, calibration, dose calculations, radiobiological issues, and overall safety concerns that should be addressed during the commissioning stage preceding clinical use. These guidelines are based on review of requirements of the U.S. Nuclear Regulatory Commission, U.S. Department of Transportation, International Electrotechnical Commission Medical Electrical Equipment Standard 60601, U.S. Food and Drug Administration, European Commission for CE Marking (Conformité Européenne), and institutional review boards and radiation safety committees.

60 APPLIED LIFE SCIENCES↗

Methods—Design Guidelines for Tubular Flow-through Electrodes for Use in Electroanalytical Studies of Redox Reaction Kinetics

The tubular flow-through electrode (FTE) is a facile electroanalytical tool for investigating electrochemical reaction kinetics; however, its suitability for this purpose requires careful design and operation under conditions that guarantee uniform current distribution. In this perspective article, we provide a scaling analysis of the transport and reaction processes within a tubular FTE leading to quantitative guidelines for the FTE design and operation. Two dimensionless parameters (classical Wagner number Wa I and modified Wagner number incorporating the effect of mass transport Wa II ) are utilized to compare the magnitudes of the ohmic, activation and transport resistances of the tubular FTE, and to quantify its current distribution uniformity. With the aid of analytical modeling of the current distribution, optimal ranges for these two dimensionless parameters are defined so as to ascertain uniform current distribution. Application of these guidelines to a graphite tubular FTE is shown to enable the precise determination of the charge-transfer kinetics of the ferri/ferrocyanide redox reaction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Derived concentration guideline levels for Argonne National Laboratory's building 310 area.

The derived concentration guideline level (DCGL) is the allowable residual radionuclide concentration that can remain in soil after remediation of the site without radiological restrictions on the use of the site. It is sometimes called the single radionuclide soil guideline or the soil cleanup criteria. This report documents the methodology, scenarios, and parameters used in the analysis to support establishing radionuclide DCGLs for Argonne National Laboratory's Building 310 area.

54 ENVIRONMENTAL SCIENCES↗

Strategy Guideline: Quality Management in Existing Homes - Cantilever Floor Example

This guideline is designed to highlight the QA process that can be applied to any residential building retrofit activity. The cantilevered floor retrofit detailed in this guideline is included only to provide an actual retrofit example to better illustrate the QA activities being presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Ventilation Cooling

The purpose of this measure guideline on ventilation cooling is to provide information on a cost-effective solution for reducing cooling system energy and demand in homes located in hot-dry and cold-dry climates. This guideline provides a prescriptive approach that outlines qualification criteria, selection considerations, and design and installation procedures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Postdoctoral Program Guidelines

We, the Postdoc Professional Development Program (PD2P) leadership team, wrote these postdoc guidelines to be a starting point for communication between new postdocs, their staff mentors, and their managers. These guidelines detail expectations and responsibilities of the three parties, as well as list relevant contacts. The purpose of the Postdoc Program is to bring in talented, creative people who enrich Sandia's environment by performing innovative R&D, as well as by stimulating intellectual curiosity and learning. Postdocs are temporary employees who come to Sandia for career development and advancement reasons. In general, the postdoc term is 1 year, renewable up to five times for a total of six years. However, center practices may vary; check with your manager. At term, a postdoc may apply for a staff position at Sandia or choose to move to university, industry or another lab. It is our vision that those who leave become long-term collaborators and advocates whose relationships with Sandia have a positive effect upon our national constituency.

99 GENERAL AND MISCELLANEOUS↗

Measure Guideline: Basement Insulation Basics

This guideline is intended to describe good practices for insulating basements in new and existing homes, and is intended to be a practical resources for building contractors, designers, and also to homeowners. These flowcharts are provided as a very high-level overview of the planning and selection process for basement insulation systems. Note that these guidelines—and certainly these charts—are not exhaustive. Many references are provided that discuss several viable basement systems as well as achieving thermal performance well above code minimums.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: High Efficiency Natural Gas Furnaces

This Measure Guideline covers installation of high-efficiency gas furnaces. Topics covered include when to install a high-efficiency gas furnace as a retrofit measure, how to identify and address risks, and the steps to be used in the selection and installation process. The guideline is written for Building America practitioners and HVAC contractors and installers. It includes a compilation ofinformation provided by manufacturers, researchers, and the Department of Energy as well as recent research results from the Partnership for Advanced Residential Retrofit (PARR) Building America team.

03 NATURAL GAS↗

Derived concentration guideline levels for Argonne National Laboratory's building 330 area

The derived concentration guideline level (DCGL) is the allowable residual radionuclide concentration that can remain in soil after remediation of the site without radiological restrictions on the use of the site. It is sometimes called the single radionuclide soil guideline or the soil cleanup criteria. This report documents the methodology, scenarios, and parameters used in the analysis to support establishing radionuclide DCGLs for Argonne National Laboratory’s Building 330 area.

Kamboj, S.↗

Strategy Guideline: Demonstration Home

This guideline will provide a general overview of the different kinds of demonstration home projects, a basic understanding of the different roles and responsibilities involved in the successful completion of a demonstration home, and an introduction into some of the lessons learned from actual demonstration home projects. Also, this guideline will specifically look at the communication methods employed during demonstration home projects. And lastly, we will focus on how to best create a communication plan for including an energy efficient message in a demonstration home project and carry that message to successful completion.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗