Search NASA⌕ Search

SEARCH · Search NASA

Results for “high temperature conversion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

A Perspective on Multi-Source Energy Harvesting Technology Using Piezoelectric and Thermoelectric Materials

Energy harvesting using various locally available energy sources such as vibration energy, heat, sound, or magnetic field have become attractive topics for supplying power to modular electronic devices making them run independently in extreme environments. In this paper, we will be discussing the perspectives on thermoelectric (TE) and piezoelectric materials and devices, and then the concept of multi-source energy harvester using piezoelectric and thermoelectric devices and integration of them into a reliable and independent power source. TE materials having low thermal conductivity and high figure-of-merit ( zT ) are developed to convert even a small temperature gradient efficiently into electrical energy with the state-of-the-art conversion efficiency of ~15% and output power of ~56 W from single device. The piezoelectric device architecture is configured using high performance piezoelectric ceramics (Cu-Mn-PIN-PMN-PT). These ceramics exhibit high piezoelectric coefficient with high mechanical quality factor and low dielectric loss factor. Using these piezoelectric materials, power density as high a 2 mW/cm 2 is demonstrated in 1-1.5 g vibration environments. The piezoelectric device is attached on the surface of TE module to capture both the vibration and thermal energy sources to realize dual mode energy harvester. The multi-energy transfer strategy opens opportunities for a future generation of wireless and modular electronic devices. These devices would be useful in powering wearable electronic devices, micro sensor chargers, etc. in extreme environmental conditions using body heat/thermal sources and induced motion/vibrations.

Piezoelectric↗

Design, Qualification and Integration Testing of the High-Temperature Resistance Temperature Device for Stirling Power System

The Advanced Stirling Radioisotope Generator (ASRG), developed from 2006 to 2013 under the joint sponsorship of the United States Department of Energy (DOE) and National Aeronautics and Space Administration (NASA) to provide a high-efficiency power system for future deep space missions, employed Sunpower Incorporated's Advanced Stirling Convertors (ASCs) with operating temperature up to 840 C. High-temperature operation was made possible by advanced heater head materials developed to increase reliability and thermal-to-mechanical conversion efficiency. During a mission, it is desirable to monitor the Stirling hot-end temperature as a measure of convertor health status and assist in making appropriate operating parameter adjustments to maintain the desired hot-end temperature as the radioisotope fuel decays. To facilitate these operations, a Resistance Temperature Device (RTD) that is capable of high-temperature, continuous long-life service was designed, developed and qualified for use in the ASRG. A thermal bridge was also implemented to reduce the RTD temperature exposure while still allowing an accurate projection of the ASC hot-end temperature. NASA integrated two flight-design RTDs on the ASCs and assembled into the high-fidelity Engineering Unit, the ASRG EU2, at Glenn Research Center (GRC) for extended operation and system characterization. This paper presents the design implementation and qualification of the RTD, and its performance characteristics and calibration in the ASRG EU2 testing.

Deep Space↗

Development of High Temperature Dissimilar Joint Technology for Fission Surface Power Systems

NASA is developing fission surface power (FSP) system technology as a potential option for use on the surface of the moon or Mars. The goal is to design a robust system that takes full advantage of existing materials data bases. One of the key components of the power conversion system is the hot-side Heat Exchanger (HX). One possible design for this heat exchanger requires a joint of the dissimilar metals 316L stainless steel and Inconel 718, which must sustain extended operation at high temperatures. This study compares two joining techniques, brazing and diffusion bonding, in the context of forming the requisite stainless steel to superalloy joint. The microstructures produced by brazing and diffusion bonding, the effect of brazing cycle on the mechanical tensile properties of the alloys, and the strength of several brazed joints will be discussed.

Locci, Ivan E.↗

Investigation of B 4 C for inhibiting crystallization in silica at high temperatures

Amorphous silica has numerous high temperature applications due to its inherent thermal shock resistance and low coefficient of thermal expansion (CTE). However, at the high temperatures required for processing (>1200 °C), the metastable β-cristobalite phase preferentially forms and is accompanied by a volume change, and potential cracking, upon conversion to the low temperature α-cristobalite phase. The CTE of the final crystalline phase is an order of magnitude higher than its amorphous counterpart. Here experimental results demonstrate that small additions of B 4 C (3.5 wt%) effectively inhibit silica crystallization in powder and sintered gel-cast forms up to 22h at temperatures as high as 1500°C as confirmed via x-ray diffraction. Further, the oxidation of B 4 C to B 2 O 3 and its subsequent melt and evaporation disrupts the nucleation and growth of the cristobalite phase. The mechanism for crystallization inhibition is further explored through optical microscopy to probe changes in surface morphology.

36 MATERIALS SCIENCE↗

Optimize out-of-core thermionic energy conversion for nuclear electric propulsion

Thermionic energy conversion (TEC) potentialities for nuclear electric propulsion (NEP) are examined. Considering current designs, their limitations, and risks raises critical questions about the use of TEC for NEP. Apparently a reactor cooled by hotter-than-1675 K heat pipes has good potentialities. TEC with higher temperatures and greater power densities than the currently proposed 1650 K, 5-to-6 W/sq cm version offers substantial gains. Other approaches to high-temperature electric isolation appear also promising. A high-power-density, high-temperature TEC for NEP appears, therefore, attainable. It is recommended to optimize out-of-core thermionic energy conversion for nuclear electric propulsion. Although current TEC designs for NEP seem unnecessary compared with Brayton versions, large gains are apparently possible with increased temperatures and greater power densities.

Morris, J. F.↗

In-Situ Detection of Process-Induced Porosity During Cure of Out-of-Autoclave Composites

Composite materials offer unique benefits in aerospace applications, including high strength-to-weight ratio, and are becoming increasingly used by industry manufacturers. Current manufacturing and processing methods can lead to defects in the composites, which are identified after fabrication using inspection methods. This study utilized a high-temperature ultrasonic inspection system to detect process-induced porosity in an out-of-autoclave (OOA) composite panel during cure. In order to perform ultrasonic scans in-situ during cure, the system needed to be able to operate at oven temperatures up to 200 °C. There are no commercially available ultrasonic scanning systems that can operate continuously at these temperatures, so an enclosure was fabricated to insulate the ultrasonic system in the curing oven. The enclosure housed a MISTRAS® motorized X-Y raster scanner and contact transducer (Olympus® X2002). The Olympus® X2002 contact transducer is a continuous high-temperature delay line transducer with a center frequency of 2.25 MHz. In order to prevent the inside of the enclosure from reaching high temperatures, a sparge pipe inside the cooling enclosure was connected to a liquid nitrogen (LN2) tank outside of the oven via insulated hoses. The cooling system was automatically controlled by a temperature controller that was programmed to open a solenoid valve along the hose at 31 ℃ and close at 28 ℃ inside the cooling enclosure. When the solenoid valve was open, LN2 would flow from the LN2 tank and vaporize prior to reaching cooling enclosure. A U-shaped sparge pipe had holes drilled along its length to uniformly introduce cold nitrogen gas into the cooling enclosure. This prevented the motors from ever reaching the maximum desired operating temperature of 38 ℃. In the bottom of the enclosure, the tool plate was placed with the composite facing the outside of the enclosure, exposing it to the temperatures of the oven. The tool plate was 63.5 mm thick borosilicate glass, which was chosen for its low ultrasonic attenuation and moderate thermal conductivity. A thin layer of ultrasonic couplant was placed on the tool plate. The transducer sent and received ultrasonic waves through the tool plate into the composite. A MISTRAS® Remote UT System performed all wave generation, analog to digital conversion, and data acquisition and processing. The transducer was connected directly to the Remote UT System via a high-temperature BNC cable (CD International, RG-316). Polyimide insulated copper wire was used to connect the scanner to a 2-axis motor drive, which was connected to the Remote UT System. The motor drive and Remote UT System were located outside the industrial oven. A diagram of the ultrasonic system is shown in Figure 1. Figure 1: Diagram of ultrasonic in-situ defect detection system. In this study, a porosity gradient was introduced into the carbon fiber reinforced polymer (CFRP) composite through a misfit of the part and caul plate. A 24-ply quasi-isotropic ([0/90, ±45]12S) composite panel was laid up using Newport® AS4C-M/NB321 out-of-autoclave (OOA) plain weave (PW) prepreg (42% resin content, 195 g/m2). The first 16 plies were 203 mm × 203 mm. Ply drops were incorporated into the panel by decreasing the length of plies 17-24. The sizes of each ply are included in Table 1. All plies were centered along their length (x-axis) creating a trapezoidal type cross-section. Table 1: Ply sizes Plies Length (mm) Width (mm) 1-16 203 203 17-18 102 203 19-20 85 203 21-22 68 203 23-24 51 203 A 15-5 stainless steel caul plate (Size: 203 × 203 × 1.2 mm) was placed on the laminate. The composite and caul plate were vacuum bagged to the tool plate. Per the product datasheet, Newport 321 can be cured between 121 °C and 149 °C, depending on service temperature, with a hold for 90-120 minutes. Based on prior thermal testing of the cooling enclosure, the desired composite temperature cycle could be attained when the air temperature of the oven was ramped to 160 °C at a rate of 1.7 °C/min with a 3 hour hold. The extended hold was not necessary to cure the composite, but did allow for additional scans at the cure temperature during preliminary testing. The composite panel was under vacuum pressure for the entire cure cycle. Under vacuum, the caul plate deformed causing high and low pressure regions. The low-pressure regions formed high porosity in the composite part. The ultrasonic data collected showed that the inspection system was able to monitor the evolution of porosity within the composite throughout the cure cycle. Fifty scans of a 203 mm × 51 mm (8 in. × 2 in.) area of the composite were completed throughout the cure cycle. The scan speed was set to 43 mm/s in the x-direction and 36 mm/s in the y-direction, with a 1.0 mm/pixel resolution in both directions. Each scan took approximately five minutes to complete. Figure 2 shows C-scan amplitude data (top view) from one scan during the cure cycle. The color map indicates the maximum amplitude (%) measured with a time gate that contains reflections from the back surface (furthest from the transducer in contact with the caul plate) of the composite. Because porosity in the composite increases the ultrasonic attenuation in the composite part, a higher amplitude (red) indicates low porosity and a lower amplitude (blue) indicates high porosity. The regions where the caul plate was applying increased pressure (center and ends of the panel) resulted in reduced porosity, whereas the ply drop regions had reduced pressure and thus had higher porosity. Figure 2: Amplitude C-scan (top view) of OOA composite from one scan during the 160 °C temperature hold. Higher amplitude (red) indicates low porosity. Lower amplitude (blue) indicates high porosity. A B-scan is a two-dimensional image plotting the ultrasonic signals from a single y-position at every x-location of the composite panel. The travel time (μs) of the ultrasonic wave (representing the through-thickness location) is plotted along the y-axis, and the ultrasonic wave signal is represented as a contour map. Based on the B-scan data, the location of the defects with respect to the composite thickness was able to be determined. The ply drop regions had high porosity near the front (tool plate) surface of the composite (Figure 3). Figure 3: B-scan (cross-section view) of OOA composite from one scan during the 160 °C temperature hold. Using the data obtained from amplitude C-scans and B-scans throughout the cure cycle, the high and low porosity regions within the composite laminate were detected and localized with high spatial resolution. This paper will discuss the evolution of porosity content in the OOA composite during cure. OOA tests aided the transition of this system to an autoclave, which is the primary method of curing aerospace-grade thermoset composites.

Tyler B. Hudson↗

A modeling study of ocean thermal energy conversion resource and potential environmental effects around Kailua-Kona, Hawaii

Ocean Thermal Energy Conversion (OTEC) offers a promising renewable energy solution through a heat exchange process using the temperature difference between warm surface seawater and cold deep seawater. Because accurate resource characterization is critical for the optimal design and implementation of OTEC systems, a high-resolution numerical model is employed to better characterize the OTEC resource at Kona, Hawaii. Our model provides detailed spatial and temporal variability of the thermal gradient, which is essential for assessing the viability and efficiency of OTEC systems. The model results reveal distinct patterns and dynamics not captured by existing observations or models (e.g., lower-resolution information). These findings highlight the importance of using high-resolution models for accurate predictions of thermal gradient variability, ultimately supporting more efficient and sustainable OTEC deployment. Additionally, the study investigates the impacts of mixed water discharge from OTEC plants that can cause shock to organisms living in the surface water and potentially destabilize the water column. Understanding these effects is vital for minimizing any potential negative environmental consequences and ensuring the long-term viability of OTEC operations. Further, our model improves OTEC resource characterization, which can lead to optimal design and deployment of OTEC systems. The analysis of OTEC water discharge impacts can accelerate the development of OTEC technologies, overcoming permitting/consenting challenges. These findings contribute to the broader adoption of high-resolution modeling in ocean energy resource characterization, particularly for OTEC applications.

30 DIRECT ENERGY CONVERSION↗

Effects of Adiabatic Heating on the High Strain Rate Deformation of Polymer Matrix Composites

Polymer matrix composites (PMCs) are increasingly being used in aerospace structures that are expected to experience complex dynamic loading conditions throughout their lifetime. As such, a detailed understanding of the high strain rate behavior of the constituents, particularly the strain rate, temperature, and pressure dependent polymer matrix, is paramount. In this paper, preliminary efforts in modeling experimentally observed temperature rises due to plastic deformation in PMCs subjected to dynamic loading are presented. To this end, an existing isothermal viscoplastic polymer constitutive formulation is extended to model adiabatic conditions by incorporating temperature dependent elastic properties and modifying the components of the inelastic strain rate tensor to explicitly depend on temperature. It is demonstrated that the modified polymer constitutive model is capable of capturing strain rate and temperature dependent yield as well as thermal softening associated with the conversion of plastic work to heat at high rates of strain. The modified constitutive model is then embedded within a strength of materials based micromechanics framework to investigate the manifestation of matrix thermal softening, due to the conversion of plastic work to heat, on the high strain rate response of a T700Epon 862 (T700E862) unidirectional composite. Adiabatic model predictions for high strain rate composite longitudinal tensile, transverse tensile, and in-plane shear loading are presented. Results show a substantial deviation from isothermal conditions; significant thermal softening is observed for matrix dominated deformation modes (transverse tension and in-plane shear), highlighting the importance of accounting for the conversion of plastic work to heat in the polymer matrix in the high strain rate analysis of PMC structures.

polymer matrix composites↗

Evaporator Temperature Transient Testing of a High-Performance Sodium Filled Heat Pipe

Heat pipes are two-phase heat transfer devices that enable passive removal of heat from the reactor core to the power conversion system in heat pipe-cooled microreactor designs. Experimental investigations of heat pipe transients are needed for technology demonstration, verification and validation of numerical codes, and the establishment of regulatory requirements. The Single Primary Heat Extraction and Removal Emulator (SPHERE) facility at Idaho National Laboratory (INL) serves as a platform for evaluating the dynamic response of high-temperature heat pipes under a variety of operating conditions. The present work details the experimental investigation of a high-performance, defined as over 2 kW sodium heat pipe subjected to rapid input power fluctuations induced by sudden changes in the evaporator temperature setpoint. In addition, the heat pipe was subjected to an asymmetrical heat load where a subset of heaters operated at 30% and 70% below their nominal power. These experimental conditions were chosen to simulate thermal and operational stresses expected to be encountered in microreactors to provide data on heat pipe behavior during such important transient events. Key data and performance metrics, including time series of temperatures and strains, axial temperature profiles, thermal response times, and heat transfer capabilities, the thermal output over thermal input, were reported and discussed. The results highlight the resilience of heat pipes, revealing their potential to maintain thermal stability and efficiency under varying power loads. Lastly, the paper concludes with a discussion on the significance of the results and their implications for future research.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Renewal of corrosion protection of coated aluminum after welding

Effectiveness of conversion coatings designed to protect aluminum alloys against atmospheric corrosion is reduced after exposure to high temperature or welding. Damaged coating should be manually stripped six inches from the weld and then recoated by sponge or spray with the original solution.

Higgins, R. H.↗

Better Proton-Conducting Polymers for Fuel-Cell Membranes

Polyoxyphenylene triazole sulfonic acid has been proposed as a basis for development of improved proton-conducting polymeric materials for solid-electrolyte membranes in hydrogen/air fuel cells. Heretofore, the proton-conducting membrane materials of choice have been exemplified by a family of perfluorosulfonic acid-based polymers (Nafion7 or equivalent). These materials are suitable for operation in the temperature of 75 to 85 C, but in order to reduce the sizes and/or increase the energy-conversion efficiencies of fuel-cell systems, it would be desirable to increase temperatures to as high as 120 C for transportation applications, and to as high as 180 C for stationary applications. However, at 120 C and at relative humidity values below 50 percent, the loss of water from perfluorosulfonic acid-based polymer membranes results in fuel-cell power densities too low to be of practical value. Therefore, membrane electrolyte materials that have usefully high proton conductivity in the temperature range of 180 C at low relative humidity and that do not rely on water for proton conduction at 180 C would be desirable. The proposed polyoxyphenylene triazole sulfonic acid-based materials have been conjectured to have these desirable properties. These materials would be free of volatile or mobile acid constituents. The generic molecular structure of these materials is intended to exploit the fact, demonstrated in previous research, that materials that contain ionizable acid and base groups covalently attached to thermally stable polymer backbones exhibit proton conduction even in the anhydrous state.

Narayan, Sri↗

Fuel cell environmental life cycle assessment : a progress report

Energy generation using fuel cells offers the possibility of high conversion efficiency and reduced pollution. Thus, in the futue, conventional methods of energy generation using coalfired power plants, natural gas turbines and internal combustion engines can potentially be replaced by fuel cells. The United States, Japan and several countries in Europe are currently developing fuel cells for transportation, distributed energy generation and portable electronics applications. On a system basis, the efficiency of chemical to electrical energy conversion in fuel cells can be as high as 45%. Also, because of the lower operating temperatures compared to turbines and internal combustion engines, emissions such as carbon monoxide and nitrogen oxides are extremely small. An assessment of the environmental impact of fuel cells over the entire lifecycle is needed to determine the specific benefits in various application scenarios. Such a comparative pollutants assessment must include a "cradle to grave" approach encompassing fuel production, fuel transportation, materials/manufacturing processes, waste management, and recycling. A comparative pollutant model would be a useful tool for industry and government in estimating energy savings and environmental credits, and providing a holistic understanding on regulatory needs. Another important benefit would be the ability to make appropriate comparisons with competitive energy generation technologies such as hybrids, turbines, and internal combustion engines, and to set up realistic targets. Also, exercising the model will assist in the initial screening for potential hot spots and showstoppers and focus on the right component technologies design for manufacturing, designs for input substitution and waste minimization, and prevent any unforeseen burdens.

Narayanan, S. R.↗

Durability of Passive Thermal Control Materials Exposed to Low Earth Orbit Environment

Spacecraft components for passive thermal control need to resist degradation in the space environment. The Materials on International Space Station Experiment (MISSE) 11th, 15th, and 16th flights and the Materials Exposure and Technology Innovation in Space (METIS) 1st and 2nd flights exposed a variety of materials to the low Earth orbital environment. Materials discussed in this presentation include chemical conversion coatings per MIL-DTL-5541, thermal control coatings, and thermal protection materials for high temperature applications. Space environmental and molecular contamination effects on optical properties are reviewed. Future MISSE and METIS experiments are discussed.

space environment↗

Ortho-para-hydrogen equilibration on Jupiter

Voyager IRIS observations reveal that the Jovian para-hydrogen fraction is not in thermodynamic equilibrium near the NH3 cloud top, implying that a vertical gradient exists between the high-temperature equilibrium value of 0.25 at depth and the cloud top values. The height-dependent para-hydrogen profile is obtained using an anisotropic multiple-scattering radiative transfer model. A vertical correlation is found to exist between the location of the para-hydrogen gradient and the NH3 cloud, strongly suggesting that paramagnetic conversion on NH3 cloud particle surfaces is the dominant equilibration mechanism. Below the NH3 cloud layer, the para fraction is constant with depth and equal to the high-temperature equilibrium value of 0.25. The degree of cloud-top equilibration appears to depend on the optical depth of the NH3 cloud layer. Belt-zone variations in the para-hydrogen profile seem to be due to differences in the strength of the vertical mixing.

Carlson, Barbara E.↗

Achieving Innovation and Affordability Through Standardization of Materials Development and Testing

The successful expansion of development, innovation, and production within the aeronautics industry during the 20th century was facilitated by collaboration of government agencies with the commercial aviation companies. One of the initial products conceived from the collaboration was the ANC-5 Bulletin, first published in 1937. The ANC-5 Bulletin had intended to standardize the requirements of various government agencies in the design of aircraft structure. The national space policy shift in priority for NASA with an emphasis on transferring the travel to low earth orbit to commercial space providers highlights an opportunity and a need for the national and global space industries. The same collaboration and standardization that is documented and maintained by the industry within MIL-HDBK-5 (MMPDS-01) and MIL-HBDK-17 (nonmetallic mechanical properties) can also be exploited to standardize the thermal performance properties, processing methods, test methods, and analytical methods for use in aircraft and spacecraft design and associated propulsion systems. In addition to the definition of thermal performance description and standardization, the standardization for test methods and analysis for extreme environments (high temperature, cryogenics, deep space radiation, etc) would also be highly valuable to the industry. Its subsequent revisions and conversion to MIL-HDBK-5 and then MMPDS-01 established and then expanded to contain standardized mechanical property design values and other related design information for metallic materials used in aircraft, missiles, and space vehicles. It also includes guidance on standardization of composition, processing, and analytical methods for presentation and inclusion into the handbook. This standardization enabled an expansion of the technologies to provide efficiency and reliability to the consumers. It can be established that many individual programs within the government agencies have been overcome with development costs generated from these nonstandard requirements. Without industry standardization and acceptance, the programs are driven to shoulder the costs of determining design requirements, performance criteria, and then material qualification and certification. A significant investment that the industry could make to both reduce individual program development costs and schedules while expanding commercial space flight capabilities would be to invest in standardizing material performance properties for high temperature, cryogenic, and deep space environments for both metallic and nonmetallic materials.

Bray, M. H.↗

Room-Temperature Methane Oxidation to Formaldehyde Mediated by CoMoO + Gas-Phase Cations

Formaldehyde (HCHO) is a fundamental chemical feedstock with widespread industrial applications. The direct oxidation of methane by oxygen to formaldehyde (CH 4 + 1/2O 2 → H 2 + HCHO) under mild conditions represents an attractive but challenging transformation, as it requires both activation of the inert C–H bonds of CH 4 and suppression of overoxidation to products such as carbon dioxide. In this work, mass spectrometry experiments combined with theoretical calculations reveal that CoMoO + cations can efficiently mediate this transformation at room temperature. The unique electronic structure of CoMoO + facilitates the formation of a crucial CoMoOCH 2 + intermediate during the reaction with CH 4 and prevents methanol formation. In the subsequent oxidation reaction, the Mo atom in CoMoO + serves as the active site for O 2 adsorption, and both Mo and Co atoms act as electron donors to activate O 2 , leading to the formation of the C–O bond in formaldehyde. This work reports the first gas-phase example of achieving conversion of CH 4 to HCHO and its radical derivatives by O 2 at room temperature using heteronuclear non-noble metal cations. Remarkably, the CoMoOCH 2 + cation maintains high reactivity after adsorbing one or two CH 4 molecules. Finally, these findings provide new mechanistic insights into selective methane activation and conversion.

aldehydes↗

Investigation of applications for high-power, self-critical fissioning uranium plasma reactors

Analytical studies were conducted to investigate potentially attractive applications for gaseous nuclear cavity reactors fueled by uranium hexafluoride and its decomposition products at temperatures of 2000 to 6000 K and total pressures of a few hundred atmospheres. Approximate operating conditions and performance levels for a class of nuclear reactors in which fission energy removal is accomplished principally by radiant heat transfer from the high temperature gaseous nuclear fuel to surrounding absorbing media were determined. The results show the radiant energy deposited in the absorbing media may be efficiently utilized in energy conversion system applications which include (1) a primary energy source for high thrust, high specific impulse space propulsion, (2) an energy source for highly efficient generation of electricity, and (3) a source of high intensity photon flux for heating working fluid gases for hydrogen production or MHD power extraction.

Rodgers, R. J.↗

Pyrolysis of high-density polyethylene: Degradation behaviors, kinetics, and product characteristics

Pyrolysis is a promising technology for converting plastic waste into valuable raw materials while offering a potential solution to the global plastic pollution crisis. In this study, the thermal pyrolysis of high-density polyethylene (HDPE) is investigated in a drop tube reactor under nearly isothermal conditions. The impact of reaction temperature and gas/volatile residence time on carbon conversion and product distribution is examined across a range of 500–900°C and 3.6–32.2s, respectively. Non-condensable gas products detected by online mass spectrometry are H 2 , CH 4 , C 2 H 4 , C 2 H 6 , C 3 H 6 , and C 3 H 8 . At elevated temperatures and prolonged residence time, H 2 yield reaches as high as 8.6 wt% of the initial HDPE mass due to intensified cracking reactions of C 2 –C 3 hydrocarbons and long-chain aliphatic compounds. Consequently, pyrolysis tars consist mainly of polycyclic aromatic hydrocarbons (PAHs) with 5–7 rings, accompanied by visible coke deposition within the reactor. HDPE decomposition to volatiles is an endothermic process and it is complete at a temperature between 492°C and 525°C, depending on the heating rate employed, from non-isothermal thermogravimetric analysis and differential scanning calorimetry (TGA-DSC) measurements. The thermal degradation of HDPE pellets follows the two-dimensional nucleation growth model for conversion levels up to 0.8 with an apparent activation energy of 259–270 kJ/mol and a pre-exponential factor of 4.83 × 10 17 –1.37 × 10 19 min -1 , determined from various isoconversional methods such as Flynn-Wall-Ozawa (FWO), Kissinger-Akahira-Sunose (KAS), and Starink, along with Criado's master plots. Further, these findings provide valuable insights into optimizing process parameters and refining reactor design for pyrolysis, which can be integrated with gasification and reforming processes to enhance hydrogen production on a larger scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗