Search NASA⌕ Search

SEARCH · Search NASA

Results for “histogram”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Damage Proxy Map from Interferometric Synthetic Aperture Radar Coherence

A method, apparatus, and article of manufacture provide the ability to generate a damage proxy map. A master coherence map and a slave coherence map, for an area prior and subsequent to (including) a damage event are obtained. The slave coherence map is registered to the master coherence map. Pixel values of the slave coherence map are modified using histogram matching to provide a first histogram of the master coherence map that exactly matches a second histogram of the slave coherence map. A coherence difference between the slave coherence map and the master coherence map is computed to produce a damage proxy map. The damage proxy map is displayed with the coherence difference displayed in a visually distinguishable manner.

Yun, Sang-Ho↗

Magnetospheric Multiscale Observations of Turbulent Magnetic and Electron Velocity Fluctuations in Earth's Magnetosheath Downstream of a Quasi-Parallel Bow Shock

We present statistical single-spacecraft observations of magnetic and electron velocity fluctuations in Earth's magnetosheath, likely in the vicinity of the magnetopause, downstream of a bow shock immersed in quasi-parallel interplanetary magnetic field conditions, a situation conducive to plasma turbulence in the downstream flow. These fluctuations exhibit scale-dependent behavior, wherein histograms of their Partial Variance of Increments (PVIB or PVIV(sub e)) demonstrate highly non-Gaussian forms at small scales and are reasonably well-described by kappa distributions, albeit with fitted values of the kappa parameter only slightly larger than 1.5, exemplifying their power law nature at large values of PVI. At larger scales, the PVI histograms lose their non-Gaussian nature and are well described by both Gaussian and kappa distributions with large values of the kappa parameter. The PVI histograms furthermore exhibit kurtosis that increases with decreasing scale, a characteristic that is much more prominent in the magnetic fluctuations than in the electron velocity fluctuations. This feature that is not yet explained. In both cases, the results are characteristic of turbulent intermittency.

Pollock, C. J.↗

Probabilistic Processing of Asynchronous Geiger-Mode Avalanche Photodiode Arrays for Background Rate Measurements

A system-level performance evaluation of Geiger-mode avalanche photodiode (GmAPD) arrays requires accurate measurement and prediction of the background rate of the device due to dark counts and other spurious detection events. Since a GmAPD detector reports only a binary value and timestamp associated with an avalanche event, dark count rates are typically measured by averaging thousands of frames to support a statistically significant measurement. For both synchronous and asynchronous detector, the Poisson distributed background rates are referenced to the time each pixel is armed. Unlike for synchronous GmAPD imagers where all the pixels are armed to an array-wide arm signal, an asynchronous pixel operates independently from its neighboring pixels; requiring the background rates to be calculated using an interarrival histogram. For both types of imagers, the background rate is typically evaluated by fitting an exponential distribution to a fixed window within a measured histogram of time intervals between detection events However, if the statistics of the background rate are insufficient – whether that is due to low population sizes, saturation, or a large dynamic range of population size across the array, the pixel, or array-wide, performance metrics may report results with varying accuracy. This paper reports on an implementation of an algorithm that evaluates GmAPD background rates based on statistical metrics rather than fixed windows. The algorithm functions by determining the appropriate integration window within the interarrival time histogram based on a per-pixel count rate set by a predetermined tolerable measurement error. The implementation of the algorithm allows us to characterize GmAPD arrays with orders of magnitude spread in background rates across the detector using common statistical parameters.

Mumolo, J.↗

Reconstruction of Six-Dimensional Phase Space

A phase space is a mathematical representation of all possible physical states of a system. Particle beams at Fermilab exist within a six-dimensional (6D) phase space defined by three positional components, (x, y, z) and three momentum components, (px, py, pz). To reconstruct this space implies taking measurement data from detectors and mapping out particle behavior using computational methods. The beam detectors, however, are only able to detect spatial distribution among the events of the beam, therefore being limited to positional data. Also, due to the vast number of events in a particle beam, it is extremely difficult to analyze and differentiate every single one’s behavior. However, with Machine Learning (ML), which can distinguish between patterns and map out particle behavior more efficiently. We first used the particle beam software, G4beamline, to simulate a 10,000-event muon beam, adjusting parameters such as initial momentum magnitude (p¬0) and virtual detector position. Using ten virtual detectors, we analyzed p0 values such that minimum 9,990 events were analyzed by every detector. We then input the data from these beam simulations to a C++ program, that randomly selects 100 events, and creates a 2D histogram based on spatial distribution, detector position, and event intensity. This process is repeated 100 times to create 100 histograms per p0 value. These images were then input to a modified ResNet18 Convolutional Neural Network (CNN) for training, and to predict p0 from some unseen set of histograms. The model was accurate when trained on momentum increments of 5 MeV/c and provided with denser training samples around highly variable test values. These results displayed machine learning being able to accurately predict p0 from being trained on different particle behaviors.

Shirlee, Jermain [Fermilab]↗

Binary Analysis with Architecture and Code Section Detection using Supervised Machine Learning

When presented with an unknown binary, which may or may not be complete, having the ability to determine information about it is critical to future reverse engineering, particularly in discovering the binary’s intended use and potentially malicious nature. This paper details techniques to both identify the machine architecture of the binary, as well as to locate the important code segments within the file. This identification of unknown binaries makes use of a technique called byte histogram in addition to various machine learning (ML) techniques, which we call “What is it Binary” or WiiBin. Benefits of byte histograms reflect the simplicity of calculation and do not rely on file headers or metadata, allowing for acceptable results when only a small portion of the original file is available. Utilizing WiiBin, we were able to accurately (>80%) determine the architecture of test binaries with as little as a 20% contagious portion of the file present. We were also able to determine the location of code sections within a binary by utilizing the WiiBin framework. Ultimately, the more information that can be gleaned from a binary file, the easier it is to successfully reverse engineer.

99 GENERAL AND MISCELLANEOUS↗

Factorization-based texture segmentation

This study introduces a factorization-based approach that efficiently segments textured images. We use local spectral histograms as features, and construct an M × N feature matrix using M-dimensional feature vectors in an N-pixel image. Based on the observation that each feature can be approximated by a linear combination of several representative features, we factor the feature matrix into two matrices-one consisting of the representative features and the other containing the weights of representative features at each pixel used for linear combination. The factorization method is based on singular value decomposition and nonnegative matrix factorization. The method uses local spectral histograms to discriminate region appearances in a computationally efficient way and at the same time accurately localizes region boundaries. Finally, the experiments conducted on public segmentation data sets show the promise of this simple yet powerful approach.

97 MATHEMATICS AND COMPUTING↗

Simulations of cloud‐radiation interaction using large‐scale forcing derived from the CINDY/DYNAMO northern sounding array

Abstract The recently completed CINDY/DYNAMO field campaign observed two Madden‐Julian oscillation (MJO) events in the equatorial Indian Ocean from October to December 2011. Prior work has indicated that the moist static energy anomalies in these events grew and were sustained to a significant extent by radiative feedbacks. We present here a study of radiative fluxes and clouds in a set of cloud‐resolving simulations of these MJO events. The simulations are driven by the large‐scale forcing data set derived from the DYNAMO northern sounding array observations, and carried out in a doubly periodic domain using the Weather Research and Forecasting (WRF) model. Simulated cloud properties and radiative fluxes are compared to those derived from the S‐PolKa radar and satellite observations. To accommodate the uncertainty in simulated cloud microphysics, a number of single‐moment (1M) and double‐moment (2M) microphysical schemes in the WRF model are tested. The 1M schemes tend to underestimate radiative flux anomalies in the active phases of the MJO events, while the 2M schemes perform better, but can overestimate radiative flux anomalies. All the tested microphysics schemes exhibit biases in the shapes of the histograms of radiative fluxes and radar reflectivity. Histograms of radiative fluxes and brightness temperature indicate that radiative biases are not evenly distributed; the most significant bias occurs in rainy areas with OLR less than 150 W/m 2 in the 2M schemes. Analysis of simulated radar reflectivities indicates that this radiative flux uncertainty is closely related to the simulated stratiform cloud coverage. Single‐moment schemes underestimate stratiform cloudiness by a factor of 2, whereas 2M schemes simulate much more stratiform cloud.

54 ENVIRONMENTAL SCIENCES↗

Using the apparent diffusion coefficient to identifying MGMT promoter methylation status early in glioblastoma: importance of analytical method

Accurate knowledge of O{sup 6}-methylguanine methyltransferase (MGMT) gene promoter subtype in patients with glioblastoma (GBM) is important for treatment. However, this test is not always available. Pre-operative diffusion MRI (dMRI) can be used to probe tumour biology using the apparent diffusion coefficient (ADC); however, its ability to act as a surrogate to predict MGMT status has shown mixed results. We investigated whether this was due to variations in the method used to analyse ADC. We undertook a retrospective study of 32 patients with GBM who had MGMT status measured. Matching pre-operative MRI data were used to calculate the ADC within contrast enhancing regions of tumour. The relationship between ADC and MGMT was examined using two published ADC methods. A strong trend between a measure of ‘minimum ADC’ and methylation status was seen. An elevated minimum ADC was more likely in the methylated compared to the unmethylated MGMT group (U = 56, P = 0.0561). In contrast, utilising a two-mixture model histogram approach, a significant reduction in mean measure of the ‘low ADC’ component within the histogram was associated with an MGMT promoter methylation subtype (P < 0.0246). This study shows that within the same patient cohort, the method selected to analyse ADC measures has a significant bearing on the use of that metric as a surrogate marker of MGMT status. Thus for dMRI data to be clinically useful, consistent methods of data analysis need to be established prior to establishing any relationship with genetic or epigenetic profiling.

60 APPLIED LIFE SCIENCES↗

Juxtatumoral perinephric fat analysis in clear cell renal cell carcinoma

Purpose: The purpose of the study was to evaluate the feasibility of using contrast-enhanced computed tomography (CECT)-based texture analysis (CTTA) metrics to differentiate between juxtatumoral perinephric fat (JPF) surrounding low-grade (ISUP 1–2) versus high-grade (ISUP 3–4) clear cell renal cell carcinoma (ccRCC). Methods: In this IRB-approved study, we retrospectively queried the surgical database between June 2009 and April 2016 and identified 83 patients with pathologically confirmed ccRCC (low grade: n = 54, mean age = 61.5 years, 18F/35M; high grade n = 30, mean age = 61.7 years, 8F/22M) who also had pre-operative multiphase CT acquisitions. CT images were transferred to a 3D workstation, and nephrographic phase JPF regions were manually segmented. Using an in-house developed Matlab program, a CTTA panel comprising of texture metrics extracted using six different methods, histogram, 2D- and 3D-Gray-level co-occurrence matrix (GLCM) and Gray-level difference matrix (GLDM), and 2D-Fast Fourier Transform (FFT) analyses, was applied to the segmented images to assess JPF textural heterogeneity in low- versus high-grade ccRCC. Univariate analysis and receiver-operator characteristics (ROC) analysis were used to assess interclass differences in texture metrics and their prediction accuracy, respectively. Results: All methods except GLCM consistently revealed increased heterogeneity in the JPF surrounding high- versus low-grade ccRCC. FFT showed increased complexity index (p < 0.01). Histogram analysis showed increased kurtosis and positive skewness in (p < 0.03), and GLDM analysis showed decreased measure of correlation coefficient (MCC) (p < 0.04). Several of the GLCM metrics showed statistically significant (p < 0.04) textural differences between the two groups, but with no consistent trend. ROC analysis showed that MCC in GLCM analysis had an area under the curve of 0.75. Conclusions: Our study suggests that CTTA of ccRCC shows statistically significant textural differences in JPF surrounding high- versus low-grade ccRCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accounting for Parameter Uncertainty in Reservoir Uncertainty Assessment: The Conditional Finite-Domain Approach

An important aim of modern geostatistical modeling is to quantify uncertainty in geological systems. Geostatistical modeling requires many input parameters. The input univariate distribution or histogram is perhaps the most important. A new method for assessing uncertainty in the histogram, particularly uncertainty in the mean, is presented. This method, referred to as the conditional finite-domain (CFD) approach, accounts for the size of the domain and the local conditioning data. It is a stochastic approach based on a multivariate Gaussian distribution. The CFD approach is shown to be convergent, design independent, and parameterization invariant. The performance of the CFD approach is illustrated in a case study focusing on the impact of the number of data and the range of correlation on the limiting uncertainty in the parameters. The spatial bootstrap method and CFD approach are compared. As the number of data increases, uncertainty in the sample mean decreases in both the spatial bootstrap and the CFD. Contrary to spatial bootstrap, uncertainty in the sample mean in the CFD approach decreases as the range of correlation increases. This is a direct result of the conditioning data being more correlated to unsampled locations in the finite domain. The sensitivity of the limiting uncertainty relative to the variogram and the variable limits are also discussed.

97 MATHEMATICS AND COMPUTING↗

Measurement uncertainty of rossi-alpha neutron experiments

Rossi-alpha neutron experiments are used to estimate the prompt neutron decay constant of a fissile assembly, a quantity of widespread interest in applications including in nuclear nonproliferation and criticality safety. This work develops a mathematical model to efficiently estimate measurement uncertainty of Rossi-alpha neutron experiments inferred from a two-exponential fit model with histogram binning. The derived uncertainty estimates were validated using repeated Rossi-alpha measurements of a subcritical, 4.5-kg sphere of weapons-grade, alpha-phase plutonium with nickel, copper, tungsten, and polyethylene reflectors. The estimates of uncertainty for the histogram data produced by the model were conservative and agree with the reference uncertainties within noise. The estimates of the prompt neutron decay constant uncertainty agreed with the reference uncertainties within one standard deviation. In conclusion, the proposed model will reduce total measurement times, ultimately reducing operational and procedural costs in application.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Probability Density Function Control for Stochastic Nonlinear Systems using Monte Carlo Simulation

This paper presents a fast implementation framework of output probability density function (PDF) control for a class of stochastic nonlinear systems which are subjected to non-Gaussian noises. The statistical properties of the system outputs can be adjusted by shaping the dynamic output probability density function to track the reference stochastic distribution. However, the dynamic probability density function evolution is very difficult to obtain analytically even if the system model and the stochastic distributions of the noises are known. Motivated by Monte Carlo simulation, the dynamic probability density function can be estimated by sampling data which forms the contribution of this paper. In particular, the sampling points are generated following the stochastic distribution of the noise for each instant. These points go through the system would generate the histogram for system outputs, then the dynamic model can be established based on the dynamic histogram which reflects the randomness and the nonlinear dynamics of the investigated system. Based on the established model, the output probability density function tracking can be achieved and the simulation results and discussions show the effectiveness and benefits of the presented framework.

Zhang, Qichun↗

A direct numerical simulation study for confined non-isothermal jet impingement at moderate nozzle-to-plate distances: Capturing jet-to-ambient density effects

A direct numerical simulation (DNS) campaign is deployed for a series of confined downward oriented, non-isothermal turbulent impinging jet configurations. A baseline Reynolds number of 9960 is obtained through a precursor DNS pipe flow simulation (Re τ = 505). Three jet temperature configurations (confinement height to nozzle diameter of three) enter a cylindrical domain that share ambient and impingement plate temperatures (298.15 K). The range of jet temperatures are crafted such that the ratio of inlet to ambient density varies from unity to 0.52, showcasing the effect of density disparity on flow characteristics such as core collapse, radial mixing of momentum and energy, near-wall stagnation behavior, wall-jet profiles, and large-scale vortical structures. Surface quantities provided include mean radial heat flux and wall-shear stress profiles, and heat flux histograms at select radial stations. Results showcase increased radial normal stresses for higher temperature jets that support increased mixing, resulting in large-scale recirculation structures that are smaller, while retaining similar normalized radial wall profiles for shear stress, heat flux and pressure. Furthermore, radial plots for wall shear stress and Nusselt number showcase strong radial decay as compared to previous configurations that share similar jet and ambient temperatures. For the 373.15 K case, a Gaussian-like histogram for heat fluxes at the impingement plate transitions to a log-normal profile as radial distances increase. In contrast, the 573.15 K configuration displays a bi-modal heat flux characteristic at the impingement plate, and in similar manner to the moderate temperature counterpart, transitions to a log-normal profile at larger radial distances.

33 ADVANCED PROPULSION SYSTEMS↗

Clinical and Dosimetric Predictors of Late Rectal Syndrome After 3D-CRT for Localized Prostate Cancer: Preliminary Results of a Multicenter Prospective Study

Purpose: To assess the predictors of late rectal toxicity in a prospectively investigated group of patients treated at 70-80 Gy for prostate cancer (1.8-2 Gy fractions) with three-dimensional conformal radiotherapy. Methods and Materials: A total of 1,132 patients were entered into the study between 2002 and 2004. Three types of rectal toxicity, evaluated by a self-administered questionnaire, mainly based on the subjective objective management, analytic late effects of normal tissue system, were considered: stool frequency/tenesmus/pain, fecal incontinence, and bleeding. The data from 506 patients with a follow-up of 24 months were analyzed. The correlation between a number of clinical and dosimetric parameters and Grade 2 or greater toxicity was investigated by univariate and multivariate (MVA) logistic analyses. Results: Of the 1,132 patients, 21, 15, and 30 developed stool frequency/tenesmus/pain, fecal incontinence, and bleeding, respectively. Stool frequency/tenesmus/pain correlated with previous abdominal/pelvic surgery (MVA, p = 0.05, odds ratio [OR], 3.3). With regard to incontinence, MVA showed the volume receiving {>=}40 Gy (V{sub 40}) (p = 0.035, OR, 1.037) and surgery (p = 0.02, OR, 4.4) to be the strongest predictors. V{sub 40} to V{sub 70} were highly predictive of bleeding; V{sub 70} showed the strongest impact on MVA (p = 0.03), together with surgery (p = 0.06, OR, 2.5), which was also the main predictor of Grade 3 bleeding (p = 0.02, OR, 4.2). Conclusions: The predictive value of the dose-volume histogram was confirmed for bleeding, consistent with previously suggested constraints (V{sub 50} <55%, V{sub 60} <40%, V{sub 70} <25%, and V{sub 75} <5%). A dose-volume histogram constraint for incontinence can be suggested (V{sub 40} <65-70%). Previous abdominal/pelvic surgery correlated with all toxicity types; thus, a modified constraint for bleeding (V{sub 70} <15%) can be suggested for patients with a history of abdominal/pelvis surgery, although further validation on a larger population with longer follow-up is needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Strategy for Online Correction of Rotational Organ Motion for Intensity-Modulated Radiotherapy of Prostate Cancer

Purpose: To develop and evaluate a correction strategy for prostate rotation using gantry and collimator angle adjustments. Methods and Materials: Gantry and collimator angle adjustments were used to correct for prostate rotation without rotating the table. A formula to partially correct for left-right (LR) rotations was derived through geometric analysis of rotation-induced clinical target volume (CTV) beam's-eye-view shape changes. For 10 prostate patients, intensity-modulated radiotherapy (IMRT) plans with different margins were created. Simulating CTV LR rotation and correcting each beam by a collimator rotation, the corrected CTV dose was compared with the original and uncorrected dose. Effects of residual geometric uncertainties were assessed using a Monte Carlo technique. A large number of treatments representative for prostate patients were simulated. Dose probability histograms of the minimum CTV dose (D{sub min}) were derived, with and without online correction, resulting in a more realistic margin estimate. Results: Dosimetric analysis of all IMRT plans showed that, with rotational correction and a 2-mm margin, D{sub min} was constant to within 3% for LR rotations up to {+-}15{sup o}. The Monte Carlo dose probability histograms showed that, with correction, a margin of 4 mm ensured that 90% of patients received a D{sub min} {>=}95% of the prescribed dose. Without correction a margin of 6 mm was required. Conclusions: We developed and tested a practical method for (online) correction of prostate rotation, allowing safe and straightforward implementation of margin reduction and dose escalation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adenocarcinoma of the Esophagogastric Junction: The Pattern of Metastatic Lymph Node Dissemination as a Rationale for Elective Lymphatic Target Volume Definition

Purpose: Regional nodal metastasis after neoadjuvant chemoradiation of adenocarcinoma of the esophagogastric junction (AEG) predicts survival. We aimed to clarify the lymph node (LN) distribution of AEG according to location of the tumor mass and invasion of neighboring areas for the selection of radiotherapy planning target volume (PTV) margins. Methods and Materials: Patterns of regional spread were analyzed in pathology reports of 326 patients patients with AEG who had undergone primary resection, with {>=}15 lymph nodes examined. Tumors were classified into AEG types based on endoscopy and pathology reports. Fisher's exact test was used to compare nodal disease and tumor characteristics. Pulmonary dose-volume histograms were tested in 8 patients. Results: Nodes were positive in 81% of T2 to T4 tumors. Type of AEG, tumor size, lymphovascular invasion, and grading significantly influenced nodal distribution. We found that marked esophageal invasion of AEG II/III significantly correlated with paraesophageal nodal disease, and T3 to T4 AEG II/III had a significant rate of splenic hilum/artery nodes. Middle and lower paraesophageal nodes should be treated in T2 to T4 AEG I and AEG II with {>=}15 mm involvement above the Z-line, and T3 to T4 AEG II. The splenic hilum and artery nodes can be spared in T2 AEG tumors, especially Type I tumors. The influence of paraesophageal nodal treatment on the risk of postoperative pulmonary complications can be estimated from dose-volume histograms. Conclusions: Accurate pretherapeutic staging predicts the risk of subclinical nodal disease and should be used to select the appropriate radiotherapeutic PTV. Careful selection of the PTV can be used to maximize the therapeutic window in multimodal therapy for AEG.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intensity-Modulated Radiotherapy of Pelvic Lymph Nodes in Locally Advanced Prostate Cancer: Planning Procedures and Early Experiences

Purpose: We present planning and early clinical outcomes of a study of intensity-modulated radiotherapy (IMRT) for locally advanced prostate cancer. Methods and Materials: A total of 43 patients initially treated with an IMRT plan delivering 50 Gy to the prostate, seminal vesicles, and pelvic lymph nodes, followed by a conformal radiotherapy (CRT) plan delivering 20 Gy to the prostate and seminal vesicles, were studied. Dose-volume histogram (DVH) data for the added plans were compared with dose-volume histogram data for the sum of two CRT plans for 15 cases. Gastrointestinal (GI) and genitourinary (GU) toxicity, based on the Radiation Therapy Oncology Group scoring system, was recorded weekly throughout treatment as well as 3 to 18 months after treatment and are presented. Results: Treatment with IMRT both reduced normal tissue doses and increased the minimum target doses. Intestine volumes receiving more than 40 and 50 Gy were significantly reduced (e.g., at 50 Gy, from 81 to 19 cm{sup 3}; p = 0.026), as were bladder volumes above 40, 50, and 60 Gy, rectum volumes above 30, 50, and 60 Gy, and hip joint muscle volumes above 20, 30, and 40 Gy. During treatment, Grade 2 GI toxicity was reported by 12 of 43 patients (28%), and Grade 2 to 4 GU toxicity was also observed among 12 patients (28%). With 6 to 18 months of follow-up, 2 patients (5%) experienced Grade 2 GI effects and 7 patients (16%) experienced Grade 2 GU effects. Conclusions: Use of IMRT for pelvic irradiation in prostate cancer reduces normal tissue doses, improves target coverage, and has a promising toxicity profile.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cardiac Dose From Tangential Breast Cancer Radiotherapy in the Year 2006

Purpose: To quantify the radiation doses received by the heart and coronary arteries from contemporary tangential breast or chest wall radiotherapy. Methods and Materials: Fifty consecutive patients with left-sided breast cancer and 5 consecutive patients with right-sided breast cancer treated at a large United Kingdom radiotherapy center during the year 2006 were selected. All patients were irradiated with 6- or 8-MV tangential beams to the breast or chest wall. For each dose plan, dose-volume histograms for the heart and left anterior descending (LAD) coronary artery were calculated. For 5 of the left-sided and all 5 right-sided patients, dose-volume histograms for the right and circumflex coronary arteries were also calculated. Detailed spatial assessment of dose to the LAD coronary artery was performed for 3 left-sided patients. Results: For the 50 patients given left-sided irradiation, the average mean (SD) dose was 2.3 (0.7) Gy to the heart and 7.6 (4.5) Gy to the LAD coronary artery, with the distal LAD receiving the highest doses. The right and circumflex coronary arteries received approximately 2 Gy mean dose. Part of the heart received >20 Gy in 22 left-sided patients (44%). For the 5 patients given right-sided irradiation, average mean doses to all cardiac structures were in the range 1.2 to 2 Gy. Conclusions: Heart dose from left-tangential radiotherapy has decreased considerably over the past 40 years, but part of the heart still receives >20 Gy for approximately half of left-sided patients. Cardiac dose for right-sided patients was generally from scattered irradiation alone.

62 RADIOLOGY AND NUCLEAR MEDICINE↗