Search NASA⌕ Search

SEARCH · Search NASA

Results for “humidity sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

The effects of ground hydrology on climate sensitivity to solar constant variations

The effects of two different evaporation parameterizations on the climate sensitivity to solar constant variations are investigated by using a zonally averaged climate model. The model is based on a two-level quasi-geostrophic zonally averaged annual mean model. One of the evaporation parameterizations tested is a nonlinear formulation with the Bowen ratio determined by the predicted vertical temperature and humidity gradients near the earth's surface. The other is the linear formulation with the Bowen ratio essentially determined by the prescribed linear coefficient.

Chou, S. H.↗

Variational assimilation of VAS data into a mesoscale model Assimilation method and sensitivity experiments

The assimilation of temperature and moisture gradient information from the Visible IR Spin-Scan Radiometer's Atmospheric Sounder (VAS) into a mesoscale model is presently undertaken by means of a variational method and followed by tests of the sensitivity of both diabatic and adiabatic versions of the model to VAS data assimilations for the case of July 20-21, 1981. The synoptic scale effects of the assimilation of VAS data are noted to be negligible; the greatest impact was instead on mesoscale forecasts of convective instability patterns. The additional assimilation of relative humidity gradients did not significantly change the patterns of the forecast instabilities. The greatest improvements from assimilation resulted from the resolution of the strong mesoscale temperature gradients by the asynoptic VAS data.

Cram, J. M.↗

Comparison of INP Parameterizations for Dust Minerals in Climatological Simulations With a Global Model

The effect of aerosol particles on ice nucleation and, in turn, the formation of ice and mixed phase clouds is recognized as one of the largest sources of uncertainty in weather and climate prediction. We utilize an improved sectional dust module in NASA GISS Earth System ModelE2.1, which distinguishes eight different mineral species and accretions between iron oxides and the other minerals. Simulations over a period of 20 years have been carried out with this model, and the mineral fields and other model variables (temperature, relative humidity) are used to calculate the ice nucleating particle (INP) number concentration, applying time-independent and time-dependent INP parameterizations, such as active site parameterization and water activity based immersion freezing model (ABIFM). We study how the dependence of the parameterizations on different model variables affects the mean INP number concentration. The sensitivity of the INP number concentration to fundamental dust properties such as emitted mineral size distributions and mixing state between minerals is also investigated. Results show that the sensitivity of the total INP number concentration to the emitted dust size distribution is rather small, but the sensitivity over the whole size range obscures offsetting differences in the magnitude and the sign of the sensitivity between smaller and larger particles.

INP Parameterizations↗

Atmospheric refractivity corrections in satellite laser ranging

Atmospheric refraction can cause significant errors in satellite laser ranging (SLR) systems. There are two techniques which can be used to correct for these errors. Atmospheric models based upon surface measurements of pressure, temperature, and relative humidity have been shown by ray tracing to be accurate to within a few centimeters at 20 deg elevation angle. The residual errors in the models are thought to be primarily caused by horizontal gradients in the refractivity. Although models have been developed to predict the gradient effects, initial studies show that they can be sensitive to local topographic effects. Atmospheric turbulence can introduce random fluctuations in the refractivity, but only introduces centimeter level errors at elevation angles below 10 deg. Pulsed two-color ranging systems can directly measure the atmospheric delay in satellite ranging. These systems require mode-locked multiple-frequency lasers and streak-camera-based receivers and currently appear capable of measuring the atmospheric delay with an accuracy of 0.5 cm or better.

Abshire, J. B.↗

Analyses of moisture in polymers and composites

A suitable method for the direct measurement of moisture concentrations after humidity/thermal exposure on state of the art epoxy and polyimide resins and their graphite and glass fiber reinforcements was investigated. Methods for the determination of moisture concentration profiles, moisture diffusion modeling and moisture induced chemical changes were examined. Carefully fabricated, precharacterized epoxy and polyimide neat resins and their AS graphite and S glass reinforced composites were exposed to humid conditions using heavy water (D20), at ambient and elevated temperatures. These specimens were fixtured to theoretically limit the D20 permeation to a unidirectional penetration axis. The analytical techniques evaluated were: (1) laser pyrolysis gas chromatography mass spectrometry; (2) solids probe mass spectrometry; (3) laser pyrolysis conventional infrared spectroscopy; and (4) infrared imaging thermovision. The most reproducible and sensitive technique was solids probe mass spectrometry. The fabricated exposed specimens were analyzed for D20 profiling after humidity/thermal conditioning at three exposure time durations.

Ryan, L. E.↗

Comments on "The Sensitivity Study of Radiative-Convective Equilibrium in the Tropics with a Convective Resolving Model"

In general, there are two broad scientific objectives when using cloud resolving models (CRMs or cloud ensemble models-CEMs) to study tropical convection. The first one is to use them as a physics resolving models to understand the dynamic and microphysical processes associated with the tropical water and energy cycles and their role in the climate system. The second approach is to use the CRMs to improve the representation of moist processes and their interaction with radiation in large-scale models. In order to improve the credibility of the CRMs and achieve the above goals, CRMs using identical initial conditions and large-scale influences need to produce very similar results. Two CRMs produced different statistical equilibrium (SE) states even though both used the same initial thermodynamic and wind conditions. Sensitivity tests to identify the major physical processes that determine the SE states for the different CRM simulations were performed. Their results indicated that atmospheric horizontal wind is treated quite differently in these two CRMs. The model that had stronger surface winds and consequently larger latent and sensible heat fluxes from the ocean produced a warmer and more humid modeled thermodynamic SE state. In addition, the domain mean thermodynamic state is more unstable for those experiments that produced a warmer and more humid SE state. Their simulated wet (warm and humid) SE states are thermally more stable in the lower troposphere (from the surface to 4-5 km in altitude). The large-scale horizontal advective effects on temperature and water vapor mixing ratio are needed when using CRMs to perform long-term integrations to study convective feedback under specified large-scale environments. In addition, it is suggested that the dry and cold SE state simulated was caused by enhanced precipitation but not enough surface evaporation. We find some problems with the interpretation of these three phenomena.

Tao, W.-K.↗

A simulation model for the analysis of Space Station gas-phase trace contaminants

A simulation model for the analysis of gas-phase trace contaminants in the cabin air of the NASA Space Station Reference Configuration was developed at the NASA Langley Research Center. The model predicts changes in trace contaminant concentrations from both physical and chemical sources and sinks as a function of time. Simulations were performed in which values for relative humidity, temperature, radiation intensity, pressure, and initial species concentrations were constrained to values for these parameters measured and modeled in the continental tropics at the earth's surface. Species concentrations simulated using the model compared favorably with concentrations in the continental tropics which demonstrated that the chemical mechanism in the trace contaminant model approximates changes in atmospheric species concentrations. The sensitivity of initial species concentrations to producing changes in additional species concentrations was also assessed. Results from the model indicated that chemical reactions will be important in determining the composition of cabin air in the Space Station. It is anticipated that the trace contaminant model will be useful in assessing the impact of experiments and commercial operations on the composition of the cabin air in the Space Station.

Brewer, Dana A.↗

On the Sensitivity of the Diurnal Cycle in the Amazon to Convective Intensity

This presentation uses publicly available CERES and radiosonde data to investigate the sensitivity of thetropical convective diurnal cycle to atmosphere state. Averaging surface observations into regimes of convective intensitydefined by satellite shows great promise for physical understandingof convection.• Convective processes in the Amazon are highly variable seasonallyand locally.• Buoyancy/CIN more important JJA– Mesoscale/synoptic features easier to separate– Length/depth of buoyancy layer very important in DJF (EL).• Moisture more important DJF, esp. UTH– Humidity of lower atmosphere significantly impacts LTS, LCL and abilityfor parcels to reach LFC.• Lower level jet strength/direction important• Convective initiation correlated with LTS, LR, LTH, EL• Duration/Phase better correlated with humidity variables• Surface Flux amplitude well correlated with convection

Itterly, Kyle↗

The 2006 Cape Canaveral Air Force Station Range Reference Atmosphere Model Validation Study and Sensitivity Analysis to the National Aeronautics and Space Administration's Space Shuttle

NASA's Space Shuttle utilizes atmospheric thermodynamic properties to evaluate structural dynamics and vehicle flight performance impacts by the atmosphere during ascent. Statistical characteristics of atmospheric thermodynamic properties at Kennedy Space Center (KSC) used in Space. Shuttle Vehicle assessments are contained in the Cape Canaveral Air Force Station (CCAFS) Range Reference Atmosphere (RRA) Database. Database contains tabulations for monthly and annual means (mu), standard deviations (sigma) and skewness of wind and thermodynamic variables. Wind, Thermodynamic, Humidity and Hydrostatic parameters 1 km resolution interval from 0-30 km 2 km resolution interval 30-70 km Multiple revisions of the CCAFS RRA database have been developed since initial RRA published in 1963. 1971, 1983, 2006 Space Shuttle program utilized 1983 version for use in deriving "hot" and "cold" atmospheres, atmospheric density dispersions for use in vehicle certification analyses and selection of atmospheric thermodynamic profiles for use in vehicle ascent design and certification analyses. During STS-114 launch preparations in July 2005 atmospheric density observations between 50-80 kft exceeded density limits used for aerodynamic ascent heating constraints in vehicle certification analyses. Mission specific analyses were conducted and concluded that the density bias resulted in small changes to heating rates and integrated heat loading on the vehicle. In 2001, the Air Force Combat Climatology Center began developing an updated RRA for CCAFS.

Decker, Ryan↗

Airborne and Ground-Based Measurements Using a High-Performance Raman Lidar

A high-performance Raman lidar operating in the UV portion of the spectrum has been used to acquire, for the first time using a single lidar, simultaneous airborne profiles of the water vapor mixing ratio, aerosol backscatter, aerosol extinction, aerosol depolarization and research mode measurements of cloud liquid water, cloud droplet radius, and number density. The Raman Airborne Spectroscopic Lidar (RASL) system was installed in a Beechcraft King Air B200 aircraft and was flown over the mid-Atlantic United States during July August 2007 at altitudes ranging between 5 and 8 km. During these flights, despite suboptimal laser performance and subaperture use of the telescope, all RASL measurement expectations were met, except that of aerosol extinction. Following the Water Vapor Validation Experiment Satellite/Sondes (WAVES_2007) field campaign in the summer of 2007, RASL was installed in a mobile trailer for groundbased use during the Measurements of Humidity and Validation Experiment (MOHAVE-II) field campaign held during October 2007 at the Jet Propulsion Laboratory s Table Mountain Facility in southern California. This ground-based configuration of the lidar hardware is called Atmospheric Lidar for Validation, Interagency Collaboration and Education (ALVICE). During theMOHAVE-II field campaign, during which only nighttime measurements were made, ALVICE demonstrated significant sensitivity to lower-stratospheric water vapor. Numerical simulation and comparisons with a cryogenic frost-point hygrometer are used to demonstrate that a system with the performance characteristics of RASL ALVICE should indeed be able to quantify water vapor well into the lower stratosphere with extended averaging from an elevated location like Table Mountain. The same design considerations that optimize Raman lidar for airborne use on a small research aircraft are, therefore, shown to yield significant dividends in the quantification of lower-stratospheric water vapor. The MOHAVE-II measurements, along with numerical simulation, were used to determine that the likely reason for the suboptimal airborne aerosol extinction performance during theWAVES_2007 campaign was amisaligned interference filter. With full laser power and a properly tuned interference filter,RASL is shown to be capable ofmeasuring themain water vapor and aerosol parameters with temporal resolutions of between 2 and 45 s and spatial resolutions ranging from 30 to 330 m from a flight altitude of 8 km with precision of generally less than 10%, providing performance that is competitive with some airborne Differential Absorption Lidar (DIAL) water vapor and High Spectral Resolution Lidar (HSRL) aerosol instruments. The use of diode-pumped laser technology would improve the performance of an airborne Raman lidar and permit additional instrumentation to be carried on board a small research aircraft. The combined airborne and ground-based measurements presented here demonstrate a level of versatility in Raman lidar that may be impossible to duplicate with any other single lidar technique.

Whiteman, David N.↗

Detecting Airborne Mercury by Use of Gold Nanowires

Like the palladium chloride (PdCl2) films described in the immediately preceding article, gold nanowire sensors have been found to be useful for detecting airborne elemental mercury at concentrations on the order of parts per billion (ppb). Also like the PdCl2 films, gold nanowire sensors can be regenerated under conditions much milder than those necessary for regeneration of gold films that have been used as airborne-Hg sensors. The interest in nanowire sensors in general is prompted by the expectation that nanowires of a given material covering a given surface may exhibit greater sensitivity than does a film of the same material because nanowires have a greater surface area. In preparation for experiments to demonstrate this sensor concept, sensors were fabricated by depositing gold nanowires, variously, on microhotplate or microarray sensor substrates. In the experiments, the electrical resistances were measured while the sensors were exposed to air at a temperature of 25 C and relative humidity of about 30 percent containing mercury at various concentrations from 2 to 70 ppb (see figure). The results of this and other experiments have been interpreted as signifying that sensors of this type can detect mercury at ppb concentrations in room-temperature air and can be regenerated by exposure to clean flowing air at temperatures <40 C.

Ryan, Margaret↗

Desiccant humidity control system

A water vapor and carbon dioxide sorbent material (designated HS-C) was developed for potential application to the space shuttle and tested at full scale. Capacities of two percent for carbon dioxide and four percent for water vapor were achieved using space shuttle cabin adsorption conditions and a space vacuum for desorption. Performance testing shows that water vapor can be controlled by varying the air process flow, while maintaining the ability to remove carbon dioxide. A 2000 hour life test was successfully completed, as were tests for sensitivity to cleaning solvent vapors, vibration resistance, and flammability. A system design for the space shuttle shows a 200 pound weight advantage over competitive systems and an even larger advantage for longer missions.

Lunde, P. J.↗

Feasibility Assessment of an EVA Glove Sensing Platform to Evaluate Potential Hand Injury Risk Factors

Injuries to the hands are common among astronauts who train for extravehicular activity (EVA). When the gloves are pressurized, they restrict movement and create pressure points during tasks, sometimes resulting in pain, muscle fatigue, abrasions, and occasionally more severe injuries such as onycholysis. A brief review of the Lifetime Surveillance of Astronaut Health's injury database reveals that 58% of total astronaut hand and arm injuries from NBL training between 1993 and 2010 occurred either to the fingernail, MCP, or fingertip. The purpose of this study was to assess the potential of using small sensors to measure force acting on the fingers and hand within pressurized gloves and other variables such as blood perfusion, skin temperature, humidity, fingernail strain, skin moisture, among others. Tasks were performed gloved and ungloved in a pressurizable glove box. The test demonstrated that fingernails saw greater transverse strain levels for tension or compression than for longitudinal strain, even during axial fingertip loading. Blood perfusion peaked and dropped as the finger deformed during finger presses, indicating an initial dispersion and decrease of blood perfusion levels. Force sensitive resistors to force plate comparisons showed similar force curve patterns as fingers were depressed, indicating suitable functionality for future testing. Strategies for proper placement and protection of these sensors for ideal data collection and longevity through the test session were developed and will be implemented going forward for future testing.

Reid, Christopher R.↗

Estimating ocean-air heat fluxes during cold air outbreaks by satellite

Nomograms of mean column heating due to surface sensible and latent heat fluxes were developed. Mean sensible heating of the cloud free region is related to the cloud free path (CFP, the distance from the shore to the first cloud formation) and the difference between land air and sea surface temperatures, theta sub 1 and theta sub 0, respectively. Mean latent heating is related to the CFP and the difference between land air and sea surface humidities q sub 1 and q sub 0 respectively. Results are also applicable to any path within the cloud free region. Corresponding heat fluxes may be obtained by multiplying the mean heating by the mean wind speed in the boundary layer. The sensible heating estimated by the present method is found to be in good agreement with that computed from the bulk transfer formula. The sensitivity of the solutions to the variations in the initial coastal soundings and large scale subsidence is also investigated. The results are not sensitive to divergence but are affected by the initial lapse rate of potential temperature; the greater the stability, the smaller the heating, other things being equal. Unless one knows the lapse rate at the shore, this requires another independent measurement. For this purpose the downwind slope of the square of the boundary layer height is used, the mean value of which is also directly proportional to the mean sensible heating. The height of the boundary layer should be measurable by future spaceborn lidar systems.

Chou, S. H.↗

Getting the GeoSTAR Instrument Concept Ready for a Space Mission

The Geostationary Synthetic Thinned Array Radiometer - GeoSTAR - is a microwave sounder intended for geostationary satellites. First proposed for the EO-3 New Millennium mission in 1999, the technology has since been developed under the Instrument Incubator Program. Under IIP-03 a proof-of-concept demonstrator operating in the temperature sounding 50 GHz band was developed to show that the aperture synthesis concept results in a realizable, stable and accurate imaging-sounding radiometer. Some of the most challenging technology, such as miniature low-power 183- GHz receivers used for water vapor sounding, was developed under IIP-07. The first such receiver has recently been adapted for use in the High Altitude MMIC Sounding Radiometer (HAMSR), which was previously developed under IIP-98. This receiver represents a new state of the art and outperforms the previous benchmark by an order of magnitude in radiometric sensitivity. It was first used in the GRIP hurricane field campaign in 2010, where HAMSR became the first microwave sounder to fly on the Global Hawk UAV. Now, under IIP-10, we will develop flight-like subsystems and a brassboard testing system, which will facilitate rapid implementation of a space mission. GeoSTAR is the baseline payload for the Precipitation and All-weather Temperature and Humidity (PATH) mission - one of NASA's 15 "decadal-survey" missions. Although PATH is currently in the third tier of those missions, the IIP efforts have advanced the required technology to a point where a space mission can be initiated in a time frame commensurate with second-tier missions. An even earlier Venture mission is also being considered.

millimeter-wave↗

Indicator Devices for Detection of Trace Gaseous Hydrazines

The relatively recent decrease in the acceptable time-weighted-average for hydrazines from 100 parts-per-billion (ppb) to 10 ppb rendered many trace hydrazine detectors either insensitive or inaccurate. Development of a rapid detection method for hydrazines at the new 10-ppb concentration was necessary so that test area personnel could reliably assess airborne hydrazines concentrations of a potentially contaminated area prior to entry. The reduction of Au(III) to Au(0) by hydrazines is a well characterized reaction and application of the corresponding yellow to purple color change was selected as a potentially useful means for detection of trace hydrazines in air. Tests with small quantities of KAuCl4 deposited on a variety of substrates were conducted using verified sources of 1,1-dimethylhydrazine, methylhydrazine, and hydrazine at approximately 10 ppb in air. Substrates tested were glass fiber filter paper, glass beads, anion exchange resin (AuCl4- form), and diatomaceous earth. The most successful of these substrates were glass fiber filter paper and diatomaceous earth. The KAuC14 impregnated glass fiber filter paper appeared to be somewhat light sensitive so further tests were conducted using the diatomaceous earth substrate. KAuCl4 concentration, substrate particle size, and sampler configuration were evaluated. Based on these tests, the device selected for further evaluation was a 5mm OD by 50mm glass tube containing 0.02-0.03g of 45/60 mesh diatomaceous earth coated with 2 percent KAuCl4. When connected to a sampling pump, response of the device to changes in relative humidity, ambient light, and high levels of other fluids, which might also be found in a propellant test area, was evaluated. False positive responses were not detected for exposures to relative humidity changes from 10 to 80 percent, sunlight for greater than 10 minutes, or percent levels of ammonia, isopropyl alcohol, nitrogen dioxide, and hydrogen. In addition, body emissions did not produce a false positive response in view of potential application for use inside protective clothing. The device was shown to reliably detect less than 10 ppb of the hydrazines tested using a 10 to 20L sample followed by a 2 to 5 minute color development time. Some field tests were conducted in parallel with conventional acidic firebrick sorbent tubes. There was generally very good agreement between the devices and firebrick sorbent tubes when greater than 10 ppb of a hydrazine was present.

Dee, Lou A.↗

Development of a two-dimensional zonally averaged statistical-dynamical model. I - The parameterization of moist convection and its role in the general circulation

The moist convection parameterization used in the GISS 3-D GCM is adapted for use in a two-dimensional (2-D) zonally averaged statistical-dynamical model. Experiments with different versions of the parameterization show that its impact on the general circulation in the 2-D model does not parallel its impact in the 3-D model unless the effect of zonal variations is parameterized in the moist convection calculations. A parameterization of the variations in moist static energy is introduced in which the temperature variations are calculated from baroclinic stability theory, and the relative humidity is assumed to be constant. Inclusion of the zonal variations of moist static energy in the 2-D moist convection parameterization allows just a fraction of a latitude circle to be unstable and enhances the amount of deep convection. This leads to a 2-D simulation of the general circulation very similar to that in the 3-D model. The experiments show that the general circulation is sensitive to the parameterized amount of deep convection in the subsident branch of the Hadley cell. The more there is, the weaker are the Hadley cell circulations and the westerly jets. The experiments also confirm the effects of momentum mixing associated with moist convection found by earlier investigators and, in addition, show that the momentum mixing weakens the Ferrel cell. An experiment in which the moist convection was removed while the hydrological cycle was retained and the eddy forcing was held fixed shows that moist convection by itself stabilizes the tropics, reduces the Hadley circulation, and reduces the maximum speeds in the westerly jets.

Yao, Mao-Sung↗

Document Monitor

The charters of Freedom Monitoring System will periodically assess the physical condition of the U.S. Constitution, Declaration of Independence and Bill of Rights. Although protected in helium filled glass cases, the documents are subject to damage from light vibration and humidity. The photometer is a CCD detector used as the electronic film for the camera system's scanning camera which mechanically scans the document line by line and acquires a series of images, each representing a one square inch portion of the document. Perkin-Elmer Corporation's photometer is capable of detecting changes in contrast, shape or other indicators of degradation with 5 to 10 times the sensitivity of the human eye. A Vicom image processing computer receives the data from the photometer stores it and manipulates it, allowing comparison of electronic images over time to detect changes.

Source record↗