Search NASA⌕ Search

SEARCH · Search NASA

Results for “image coding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Visual communication - Information and fidelity

This assessment of visual communication deals with image gathering, coding, and restoration as a whole rather than as separate and independent tasks. The approach focuses on two mathematical criteria, information and fidelity, and on their relationships to the entropy of the encoded data and to the visual quality of the restored image. Past applications of these criteria to the assessment of image coding and restoration have been limited to the link that connects the output of the image-gathering device to the input of the image-display device. By contrast, the approach presented in this paper explicitly includes the critical limiting factors that constrain image gathering and display. This extension leads to an end-to-end assessment theory of visual communication that combines optical design with digital processing.

Huck, Freidrich O.↗

Quantification of LEU Holdup using gamma ray imaging and inverse transport solver

Holdup is the residual amount of special nuclear material (SNM) remaining in a processing facility after the bulk materials have been cleaned out. In commercial uranium processing facilities, quantification of holdup is a major challenge because of the highly variable shapes and sizes of the deposits. Any method that attempts to generalize and calibrate deposit shapes in order to quantify holdup will be prone to high uncertainties. Uncertainties on the order of ±50% are typical in holdup results. In international safeguards applications, a ±50% uncertainty can result in a large amount of material unaccounted for (MUF) thereby increasing the difficulty of detecting material diversion and facility misuse. An imaging-based methodology has been developed with the objective of significantly reducing this uncertainty by using the true deposit shape, instead of relying on oversimplified geometric assumptions. The project is a collaboration between ORNL, Y-12, and the University of Tennessee, Knoxville, TN. Uranium sources of known masses were measured using the Germanium Gamma-ray Imager (GeGI), a high-resolution imaging spectrometer, creating a pixelated map for each spectral bin. Two different gamma imaging methods are employed in this work: coded aperture imaging and Compton imaging. A validated MonteCarlo model of the detector has been developed using the GEANT4 code for determining the intrinsic response of the detector, its enclosure, and the coded aperture mask. An inverse transport solver based on the Markov Chain Monte-Carlo approach known as Differential Evolution Adaptive Metropolis (DREAM) is employed to use the measurement data from the image pixels (coded aperture or Compton) to solve for the mass of 235 U in the deposit. A reliable method based on the DREAM solver has been developed to flag the infinite thickness condition of a uranium deposit. The project team is working towards improving the image reconstruction for Compton imaging so that a better localization of the source can be achieved. Besides treating the coded aperture and Compton imaging methods independently, the project is also evaluating a combined method that uses the Compton scatter data from a coded aperture measurement. GEANT4 simulations are being performed to evaluate the combined approach. The impact on the DREAM optimization as the source thickness progressively approaches infinite thickness is being evaluated. A number of uranium sources available at ORNL have been measured, and the DREAM results have been tested and validated for the coded aperture imaging. A similar effort will be carried out to validate the Compton based method once the development of algorithms for better localization are complete. The imaging based quantification is very amenable to unattended monitoring of holdup accumulation at key measurement points. A proof of concept measurement has been completed to demonstrate this capability The current work used the high energy resolution imager GeGI. However, the approach and methodologies are applicable to other imagers such as the cadmium zin telluride (CZT) based imager manufactured by H3D, Inc.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Real-time Free-moving Active Coded Mask 3D Gamma-Ray Imaging

The ability to localize and map the distribution of gamma-ray emitting radionuclides in 3D has applications ranging from medical imaging to nuclear security. In the case of radiological source search and nuclear contamination remediation, the deployment of freely moving detection systems such as hand- held instruments or ground/aerial-based vehicles are critical in overcoming the inverse square law and complex shielding scenarios. Using contextual sensors, these systems can simultaneously generate 3D maps of the surrounding environment and track the position and orientation of the gamma-ray sensitive detectors in that environment. The fusion of contextual scene data and gamma-ray detector data to facilitate real-time 3D gamma-ray image reconstruction has been demonstrated with mobile HPGe and CdZnTe-based Compton cameras for gamma-ray energies ranging from a few hundred keV to several MeV. Here we apply this approach for lower energy (50-400 keV) gamma-rays, using a hand-held CdZnTe-based omnidirectional imaging system and an active coded mask imaging modality. Here, we present our approach to real-time reconstruction using a scene data constrained GPU- accelerated list-mode MLEM algorithm and show results from several measurements in the lab and in the field.

3D gamma-ray imaging↗

Computational models of direct and indirect X‐ray breast imaging detectors for in silico trials

Abstract Background To facilitate in silico studies that investigate digital mammography (DM) and breast tomosynthesis (DBT), models replicating the variety in imaging performance of the DM and DBT systems, observed across manufacturers are needed. Purpose The main purpose of this work is to develop generic physics models for direct and indirect detector technology used in commercially available systems, with the goal of making them available open source to manufacturers to further tweak and develop the exact in silico replicas of their systems. Methods We recently reported on an in silico version of the SIEMENS Mammomat Inspiration DM/DBT system using an open‐source GPU‐accelerated Monte Carlo x‐ray imaging simulation code (MC‐GPU). We build on the previous version of the MC‐GPU codes to mimic the imaging performances of two other Food and Drug Administration (FDA)‐approved DM/DBT systems, such as Hologic Selenia Dimensions (HSD) and the General Electric Senographe Pristina (GSP) systems. In this work, we developed a hybrid technique to model the optical spread and signal crosstalk observed in the GSP and HSD systems. MC simulations are used to track each x‐ray photon till its first interaction within the x‐ray detector. On the other hand, the signal spread in the x‐ray detectors is modeled using previously developed analytical equations. This approach allows us to preserve the modeling accuracy offered by MC methods in the patient body, while speeding up secondary carrier transport (either electron–hole pairs or optical photons) using analytical equations in the detector. The analytical optical spread model for the indirect detector includes the depth‐dependent spread and collection of optical photons and relies on a pre‐computed set of point response functions that describe the optical spread as a function of depth. To understand the capabilities of the computational x‐ray detector models, we compared image quality metrics like modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE), simulated with our models against measured data. Please note that the purpose of these comparisons with measured data would be to gauge if the model developed as part of this work could replicate commercially used direct and indirect technology in general and not to achieve perfect fits with measured data. Results We found that the simulated image quality metrics such as MTF, NNPS, and DQE were in reasonable agreement with experimental data. To demonstrate the imaging performance of the three DM/DBT systems, we integrated the detector models with the VICTRE pipeline and simulated DM images of a fatty breast model containing a spiculated mass and a calcium oxalate cluster. In general, we found that the images generated using the indirect model appeared more blurred with a different noise texture and contrast as compared to the systems with direct detectors. Conclusions We have presented computational models of three commercially available FDA‐approved DM/DBT systems, which implement both direct and indirect detector technology. The updated versions of the MC‐GPU codes that can be used to replicate three systems are available in open source format through GitHub.

Sengupta, Aunnasha↗

Development of GPU-based Monte Carlo code for fast CT imaging dose calculation on CUDA Fermi architecture

This paper describes the development of a Graphics Processing Unit (GPU) accelerated Monte Carlo photon transport code, ARCHER{sub GPU}, to perform CT imaging dose calculations with good accuracy and performance. The code simulates interactions of photons with heterogeneous materials. It contains a detailed CT scanner model and a family of patient phantoms. Several techniques are used to optimize the code for the GPU architecture. In the accuracy and performance test, a 142 kg adult male phantom was selected, and the CT scan protocol involved a whole-body axial scan, 20-mm x-ray beam collimation, 120 kVp and a pitch of 1. A total of 9 x 108 photons were simulated and the absorbed doses to 28 radiosensitive organs/tissues were calculated. The average percentage difference of the results obtained by the general-purpose production code MCNPX and ARCHER{sub GPU} was found to be less than 0.38%, indicating an excellent agreement. The total computation time was found to be 8,689, 139 and 56 minutes for MCNPX, ARCHER{sub CPU} (6-core) and ARCHER{sub GPU}, respectively, indicating a decent speedup. Under a recent grant funding from the NIH, the project aims at developing a Monte Carlo code with the capability of sub-minute CT organ dose calculations. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Low bit rate coding of Earth science images

In this paper, the authors discuss compression based on some new ideas in vector quantization and their incorporation in a sub-band coding framework. Several variations are considered, which collectively address many of the individual compression needs within the earth science community. The approach taken in this work is based on some recent advances in the area of variable rate residual vector quantization (RVQ). This new RVQ method is considered separately and in conjunction with sub-band image decomposition. Very good results are achieved in coding a variety of earth science images. The last section of the paper provides some comparisons that illustrate the improvement in performance attributable to this approach relative the the JPEG coding standard.

Kossentini, Faouzi↗

Out of distribution evaluation for neural image compression

Official code for the NeurIPS 2023 paper "Neural Image Compression: Generalization, Robustness, and Spectral Biases". This code can be used to: - Computing spectral distortion errors of images compressed with traditional codes or neural image compression models (as proposed in the aformentioned paper) - Visualize power spectral densities and fourier heatmaps (as proposed in the aformentioned paper) - Train and test a variety of neural image compression models

Lieberman, KelseyA↗

Estimation of Aerosol Optical Depth, Pressure Elevation, Water Vapor and Calculation of Apparent Surface Reflectance from Radiance Measured by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) Using a Radiative Transfer Code

The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) is an imaging spectrometer that measures spatial images of the total up welling spectral radiance from 400 to 2500 nm at 10 nm spectral intervals. Quantitiative research and application objectives for surface investigations require conversion of the measured radiance to surface reflectance or surface leaving radiance. In this paper we describe a set of algorithms to estimate aerosol optical depth, atmospheric water vapor, and surface pressure height from the AVIRIS measured radiance.

infrared↗

Quantitative Holdup Determinations Using Coded-Aperture Gamma-Ray Imaging

Passive gamma-ray imaging can be used to create images of distributed nuclear materials. Inherently quantitative, the images provide a means to directly determine the amount of nuclear material in the imager’s field of view. However, to take advantage of quantitative imaging, one must correct for changes to the imager’s efficiency across the image. This paper presents work on detailed calibration of a coded-aperture imager based on a portable, mechanically cooled, high-purity germanium detector. This enables the use of gamma-ray imaging as a tool to determine nuclear holdup. By applying the calibrations to images of small amounts of distributed 235U, quantity estimates within a few percent of the actual amounts present were obtained, validating the approach.

Ziock, Klaus-Peter↗

Study and simulation of low rate video coding schemes

The semiannual report is included. Topics covered include communication, information science, data compression, remote sensing, color mapped images, robust coding scheme for packet video, recursively indexed differential pulse code modulation, image compression technique for use on token ring networks, and joint source/channel coder design.

Sayood, Khalid↗

Simulation and modeling for the stand-off radiation detection system (SORDS) using GEANT4

A Stand-Off Radiation Detection System (SORDS) is being developed through a joint effort by Raytheon, Los Alamos National Laboratory, Bubble Technology Industries, Radiation Monitoring Devices, and the Massachusetts Institute of Technology, for the Domestic Nuclear Detection Office (DNDO). The system is a mobile truck-based platform performing detection, imaging, and spectroscopic identification of gamma-ray sources. A Tri-Modal Imaging (TMI) approach combines active-mask coded aperture imaging, Compton imaging, and shadow imaging techniques. Monte Carlo simulation and modeling using the GEANT4 toolkit was used to generate realistic data for the development of imaging algorithms and associated software code.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A CMOS Imager with Focal Plane Compression using Predictive Coding

This paper presents a CMOS image sensor with focal-plane compression. The design has a column-level architecture and it is based on predictive coding techniques for image decorrelation. The prediction operations are performed in the analog domain to avoid quantization noise and to decrease the area complexity of the circuit, The prediction residuals are quantized and encoded by a joint quantizer/coder circuit. To save area resources, the joint quantizerlcoder circuit exploits common circuitry between a single-slope analog-to-digital converter (ADC) and a Golomb-Rice entropy coder. This combination of ADC and encoder allows the integration of the entropy coder at the column level. A prototype chip was fabricated in a 0.35 pm CMOS process. The output of the chip is a compressed bit stream. The test chip occupies a silicon area of 2.60 mm x 5.96 mm which includes an 80 X 44 APS array. Tests of the fabricated chip demonstrate the validity of the design.

Leon-Salas, Walter D.↗

Information theoretical assessment of digital imaging systems

The end-to-end performance of image gathering, coding, and restoration as a whole is considered. This approach is based on the pivotal relationship that exists between the spectral information density of the transmitted signal and the restorability of images from this signal. The information-theoretical assessment accounts for (1) the information density and efficiency of the acquired signal as a function of the image-gathering system design and the radiance-field statistics, and (2) the improvement in information efficiency and data compression that can be gained by combining image gathering with coding to reduce the signal redundancy and irrelevancy. It is concluded that images can be restored with better quality and from fewer data as the information efficiency of the data is increased. The restoration correctly explains the image gathering and coding processes and effectively suppresses the image-display degradations.

John, Sarah↗

Cyclic codes over the ring F{sub 2}+uF{sub 2}+vF{sub 2}

In this paper, we study linear and cyclic codes over the ring F{sub 2}+uF{sub 2}+vF{sub 2}. The ring F{sub 2}+uF{sub 2}+vF{sub 2} is the smallest non-Frobenius ring. We characterize the structure of cyclic codes over the ring R=F{sub 2}+uF{sub 2}+vF{sub 2} using of the work Abualrub and Saip (Des Codes Cryptogr 42:273–287, 2007). We study the rank and dual of cyclic codes of odd length over this ring. Specially, we show that the equation |C||C{sup ⊥}|=|R|{sup n} does not hold in general for a cyclic code C of length n over this ring. We also obtain some optimal binary codes as the images of cyclic codes over the ring F{sub 2}+uF{sub 2}+vF{sub 2} under a Gray map, which maps Lee weights to Hamming weights. Finally, we give a condition for cyclic codes over R that contains its dual and find quantum codes over F{sub 2} from cyclic codes over the ring F{sub 2}+uF{sub 2}+vF{sub 2}.

97 MATHEMATICS AND COMPUTING↗

IMAGING ANALYSIS OF THE HARD X-RAY TELESCOPE ProtoEXIST2 AND NEW TECHNIQUES FOR HIGH-RESOLUTION CODED-APERTURE TELESCOPES

Wide-field (≳100 deg{sup 2}) hard X-ray coded-aperture telescopes with high angular resolution (≲2′) will enable a wide range of time domain astrophysics. For instance, transient sources such as gamma-ray bursts can be precisely localized without the assistance of secondary focusing X-ray telescopes to enable rapid followup studies. On the other hand, high angular resolution in coded-aperture imaging introduces a new challenge in handling the systematic uncertainty: the average photon count per pixel is often too small to establish a proper background pattern or model the systematic uncertainty in a timescale where the model remains invariant. We introduce two new techniques to improve detection sensitivity, which are designed for, but not limited to, a high-resolution coded-aperture system: a self-background modeling scheme which utilizes continuous scan or dithering operations, and a Poisson-statistics based probabilistic approach to evaluate the significance of source detection without subtraction in handling the background. We illustrate these new imaging analysis techniques in high resolution coded-aperture telescope using the data acquired by the wide-field hard X-ray telescope ProtoEXIST2 during a high-altitude balloon flight in fall 2012. We review the imaging sensitivity of ProtoEXIST2 during the flight, and demonstrate the performance of the new techniques using our balloon flight data in comparison with a simulated ideal Poisson background.

79 ASTRONOMY AND ASTROPHYSICS↗

Imaging Analysis of the Hard X-Ray Telescope ProtoEXIST2 and New Techniques for High-Resolution Coded-Aperture Telescopes

Wide-field (greater than or approximately equal to 100 degrees squared) hard X-ray coded-aperture telescopes with high angular resolution (greater than or approximately equal to 2 minutes) will enable a wide range of time domain astrophysics. For instance, transient sources such as gamma-ray bursts can be precisely localized without the assistance of secondary focusing X-ray telescopes to enable rapid followup studies. On the other hand, high angular resolution in coded-aperture imaging introduces a new challenge in handling the systematic uncertainty: the average photon count per pixel is often too small to establish a proper background pattern or model the systematic uncertainty in a timescale where the model remains invariant. We introduce two new techniques to improve detection sensitivity, which are designed for, but not limited to, a high-resolution coded-aperture system: a self-background modeling scheme which utilizes continuous scan or dithering operations, and a Poisson-statistics based probabilistic approach to evaluate the significance of source detection without subtraction in handling the background. We illustrate these new imaging analysis techniques in high resolution coded-aperture telescope using the data acquired by the wide-field hard X-ray telescope ProtoEXIST2 during a high-altitude balloon flight in fall 2012. We review the imaging sensitivity of ProtoEXIST2 during the flight, and demonstrate the performance of the new techniques using our balloon flight data in comparison with a simulated ideal Poisson background.

balloons - instrumentation: detectors - techniques↗

Combining Measurements with Three-Dimensional Laser Scanning System and Coded Aperture Gamma-Ray Imaging Systems for International Safeguards Applications

Being able to verify the operator's declaration in regards to technical design of nuclear facilities is an important aspect of every safeguards approach. In addition to visual observation, it is relevant to know if nuclear material is present or has been present in piping and ducts not declared. The possibility of combining different measurement techniques into one tool should optimize the inspection effort and increase safeguards effectiveness. Oak Ridge National Laboratory (ORNL) is engaged in a technical collaboration project involving two U.S. Department of Energy foreign partners to investigate combining measurements from a three-dimensional (3D) laser scanning system and gamma-ray imaging systems. ORNL conducted simultaneous measurements with a coded-aperture gamma-ray imager and the 3D laser scanner in an operational facility with complex configuration and different enrichment levels and quantities of uranium. This paper describes these measurements and their results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗