Search NASA⌕ Search

SEARCH · Search NASA

Results for “image quality structure material”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Analysis of Multilayer Devices for Superconducting Electronics by High-Resolution Scanning Transmission Electron Microscopy and Energy Dispersive Spectroscopy

We used a focused ion beam to obtain cross-sectional specimens from both magnetic multilayer and Nb/Al-AlOx/Nb Josephson junction devices for characterization by scanning transmission electron microscopy (STEM) and energy dispersive X-ray spectroscopy (EDX). An automated multivariate statistical analysis of the EDX spectral images produced chemically unique component images of individual layers within the multilayer structures. STEM imaging elucidated distinct variations in film morphology, interface quality, and/or etch artifacts that could be correlated to magnetic and/or electrical properties measured on the same devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structural Anomalies Detected in Ceramic Matrix Composites Using Combined Nondestructive Evaluation and Finite Element Analysis (NDE and FEA)

Most reverse engineering approaches involve imaging or digitizing an object and then creating a computerized reconstruction that can be integrated, in three dimensions, into a particular design environment. The rapid prototyping technique builds high-quality physical prototypes directly from computer-aided design files. This fundamental technique for interpreting and interacting with large data sets is being used here via Velocity2 (an integrated image-processing software, ref. 1) using computed tomography (CT) data to produce a prototype three-dimensional test specimen model for analyses. A study at the NASA Glenn Research Center proposes to use these capabilities to conduct a combined nondestructive evaluation (NDE) and finite element analysis (FEA) to screen pretest and posttest structural anomalies in structural components. A tensile specimen made of silicon nitrite (Si3N4) ceramic matrix composite was considered to evaluate structural durability and deformity. Ceramic matrix composites are being sought as candidate materials to replace nickel-base superalloys for turbine engine applications. They have the unique characteristics of being able to withstand higher operating temperatures and harsh combustion environments. In addition, their low densities relative to metals help reduce component mass (ref. 2). Detailed three-dimensional volume rendering of the tensile test specimen was successfully carried out with Velocity2 (ref. 1) using two-dimensional images that were generated via computed tomography. Subsequent, three-dimensional finite element analyses were performed, and the results obtained were compared with those predicted by NDE-based calculations and experimental tests. It was shown that Velocity2 software can be used to render a three-dimensional object from a series of CT scan images with a minimum level of complexity. The analytical results (ref. 3) show that the high-stress regions correlated well with the damage sites identified by the CT scans and the experimental data. Furthermore, modeling of the voids collected via NDE offered an analytical advantage that resulted in more accurate assessments of the material s structural strength. The top figure shows a CT scan image of the specimen test section illustrating various hidden structural entities in the material and an optical image of the test specimen considered in this study. The bottom figure represents the stress response predicted from the finite element analyses (ref .3 ) for a selected CT slice where it clearly illustrates the correspondence of the high stress risers due to voids in the material with those predicted by the NDE. This study is continuing, and efforts are concentrated on improving the modeling capabilities to imitate the structural anomalies as detected.

Abdul-Aziz, Ali↗

Bond Line Thickness Estimation in Composite Structures Using Multiple Inspection Techniques

Imaging and other nondestructive evaluation techniques are commonly used for material characterization and defect recognition in safety critical aerospace applications, with data fusion providing the framework for uncertainty quantification in these contexts. Most commonly, forward physics-based modeling predicts the response conditioned on material properties and defect assumptions, and probabilistic methods are used to infer the hidden state of the subject of the inspection from a combination of prior information, likelihoods, and inspection data. In this paper Bayesian methods are used to estimate bond thickness in lap joints comprised of aluminum adherends using a combination of infrared thermography and ultrasound. The concept of the conflation of probability distributions is applied to combine the posterior distributions derived from thermography and ultrasound and the quality of the fused estimates are compared against the individual estimates against synthetic data that was created to mimic the inspection of a lap joint comprised of aluminum adherends.

thermal nondestructive evaluation↗

Toward In Situ Synchrotron Mapping of Crystal Selection Processes during Crystal Growth

In this work, we present an automated and rapid method for non-destructive mapping of crystal grains in a rod-shaped sample. The approach was designed for application to in situ float-zone crystal growth experiments at an x-ray synchrotron source, but could be useful in other applications. The methods have been tested on a TiO 2 boule grown in an optical float zone furnace. The approach applies a statistical filter to polycrystalline diffraction patterns on 2D detectors to rapidly determine the degree of powder-quality 1of the signal. When larger crystals emerge in the growth, their position, size and shape can be tracked using an automated blob-tracking algorithm that follows individual Bragg peaks as a function of position in a grid-scan, even when multiple crystals are contributing spots to diffraction images. This method is found to be robust as the same crystal shape can be independently reconstructed using different sets of Bragg reflections. Image segmentation methods are then used to map out the polycrystalline grains. We also note that other information about crystal quality, such as mosaicity or strain state, may be inferred and mapped from the intensity variation of the Bragg peaks at different locations within the sample.

36 MATERIALS SCIENCE↗

Structured scintillator for hard x-ray grating interferometry

Grating interferometry at conventional x-ray tubes improves the quality of radiographies and tomograms by providing phase and scattering contrast data. The main challenge encountered when applying this technique at high photon energies, as required by many applications to obtain sufficient penetration depth, is to maintain a high fringe visibility. In this letter, we report on a substantial improvement in fringe visibility and according improvements in image quality achieved by replacing the absorbing analyzer grating of the interferometer with a structured scintillator grating. This development represents a significant step toward the implementation of this technique in industrial testing and medical applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectral optimization for micro-CT

Purpose: To optimize micro-CT protocols with respect to x-ray spectra and thereby reduce radiation dose at unimpaired image quality. Methods: Simulations were performed to assess image contrast, noise, and radiation dose for different imaging tasks. The figure of merit used to determine the optimal spectrum was the dose-weighted contrast-to-noise ratio (CNRD). Both optimal photon energy and tube voltage were considered. Three different types of filtration were investigated for polychromatic x-ray spectra: 0.5 mm Al, 3.0 mm Al, and 0.2 mm Cu. Phantoms consisted of water cylinders of 20, 32, and 50 mm in diameter with a central insert of 9 mm which was filled with different contrast materials: an iodine-based contrast medium (CM) to mimic contrast-enhanced (CE) imaging, hydroxyapatite to mimic bone structures, and water with reduced density to mimic soft tissue contrast. Validation measurements were conducted on a commercially available micro-CT scanner using phantoms consisting of water-equivalent plastics. Measurements on a mouse cadaver were performed to assess potential artifacts like beam hardening and to further validate simulation results. Results: The optimal photon energy for CE imaging was found at 34 keV. For bone imaging, optimal energies were 17, 20, and 23 keV for the 20, 32, and 50 mm phantom, respectively. For density differences, optimal energies varied between 18 and 50 keV for the 20 and 50 mm phantom, respectively. For the 32 mm phantom and density differences, CNRD was found to be constant within 2.5% for the energy range of 21-60 keV. For polychromatic spectra and CMs, optimal settings were 50 kV with 0.2 mm Cu filtration, allowing for a dose reduction of 58% compared to the optimal setting for 0.5 mm Al filtration. For bone imaging, optimal tube voltages were below 35 kV. For soft tissue imaging, optimal tube settings strongly depended on phantom size. For 20 mm, low voltages were preferred. For 32 mm, CNRD was found to be almost independent of tube voltage. For 50 mm, voltages larger than 50 kV were preferred. For all three phantom sizes stronger filtration led to notable dose reduction for soft tissue imaging. Validation measurements were found to match simulations well, with deviations being less than 10%. Mouse measurements confirmed simulation results. Conclusions: Optimal photon energies and tube settings strongly depend on both phantom size and imaging task at hand. For in vivo CE imaging and density differences, strong filtration and voltages of 50-65 kV showed good overall results. For soft tissue imaging of animals the size of a rat or larger, voltages higher than 65 kV allow to greatly reduce scan times while maintaining dose efficiency. For imaging of bone structures, usage of only minimum filtration and low tube voltages of 40 kV and below allow exploiting the high contrast of bone at very low energies. Therefore, a combination of two filtrations could prove beneficial for micro-CT: a soft filtration allowing for bone imaging at low voltages, and a variable stronger filtration (e.g., 0.2 mm Cu) for soft tissue and contrast-enhanced imaging.

60 APPLIED LIFE SCIENCES↗

NASA Tech Briefs, September 2008

Topics covered include: Nanotip Carpets as Antireflection Surfaces; Nano-Engineered Catalysts for Direct Methanol Fuel Cells; Capillography of Mats of Nanofibers; Directed Growth of Carbon Nanotubes Across Gaps; High-Voltage, Asymmetric-Waveform Generator; Magic-T Junction Using Microstrip/Slotline Transitions; On-Wafer Measurement of a Silicon-Based CMOS VCO at 324 GHz; Group-III Nitride Field Emitters; HEMT Amplifiers and Equipment for their On-Wafer Testing; Thermal Spray Formation of Polymer Coatings; Improved Gas Filling and Sealing of an HC-PCF; Making More-Complex Molecules Using Superthermal Atom/Molecule Collisions; Nematic Cells for Digital Light Deflection; Improved Silica Aerogel Composite Materials; Microgravity, Mesh-Crawling Legged Robots; Advanced Active-Magnetic-Bearing Thrust- Measurement System; Thermally Actuated Hydraulic Pumps; A New, Highly Improved Two-Cycle Engine; Flexible Structural-Health-Monitoring Sheets; Alignment Pins for Assembling and Disassembling Structures; Purifying Nucleic Acids from Samples of Extremely Low Biomass; Adjustable-Viewing-Angle Endoscopic Tool for Skull Base and Brain Surgery; UV-Resistant Non-Spore-Forming Bacteria From Spacecraft-Assembly Facilities; Hard-X-Ray/Soft-Gamma-Ray Imaging Sensor Assembly for Astronomy; Simplified Modeling of Oxidation of Hydrocarbons; Near-Field Spectroscopy with Nanoparticles Deposited by AFM; Light Collimator and Monitor for a Spectroradiometer; Hyperspectral Fluorescence and Reflectance Imaging Instrument; Improving the Optical Quality Factor of the WGM Resonator; Ultra-Stable Beacon Source for Laboratory Testing of Optical Tracking; Transmissive Diffractive Optical Element Solar Concentrators; Delaying Trains of Short Light Pulses in WGM Resonators; Toward Better Modeling of Supercritical Turbulent Mixing; JPEG 2000 Encoding with Perceptual Distortion Control; Intelligent Integrated Health Management for a System of Systems; Delay Banking for Managing Air Traffic; and Spline-Based Smoothing of Airfoil Curvatures.

Source record↗

Reducing Artifacts in BF and HAADF-STEM Images of Pt/C Fuel Cells using MBIR-ARAR

Electron tomography is a powerful tool for characterization of three-dimensional (3D) nanoscale materials and devices. Bright-field (BF) and high-angle annular dark-field (HAADF) scanning transmission electron microscopy (STEM) are two widely used imaging modes in electron tomography. These imaging modalities have proven to be useful for characterizing the structure of carbon-supported platinum (Pt/C) electrocatalysts used in fuel cells, which are an important class of clean energy conversion systems. BF and HAADF-STEM images are typically simultaneously acquired due to the complementary information they contain, as BF-STEM is more suitable for characterizing carbon due to its ability to detect lighter elements, while HAADF-STEM is more suitable for characterizing platinum due to its sensitivity to atomic number. However, the quality of BF- and HAADF-STEM images is often compromised by various artifacts, such as local blurring due to abrupt contrast changes as well as missing wedge artifacts which can severely impact the accuracy of the reconstructed 3D images. The traditional methods of reconstruction, such as Filtered Back-projection (FBP), Simultaneous Iterative Reconstruction Technique (SIRT), and Model-Based Iterative Reconstruction (MBIR), are often not suitable for removing these artifacts effectively. Here, to address this challenge, we present a novel approach called MBIR with Artifact Reduction and Adaptive Regularization (MBIR-ARAR).

25 ENERGY STORAGE↗

Novel Platform for Digitization of Radiation Measurements, Decommissioning and Dismantling and Nuclear Waste Management - 18229

An innovative Platform for a seamless digitization of the information produced during the characterization of radioactive waste, contaminated objects, and in general radioprotection measurements has ben developed by CAEN SyS. The Platform is based on a spectroscopic handheld instrument integrating RFID technology, barcode reader, camera, voice recorder, and geo-localization, a selection of radiation tolerant RFID tags tested above 300 Gy integrated dose, ruggedized portable RFID readers and a secure database framework capable to collect data also from external sources such as gamma scanners and imaging systems. The Platform allows for real-time measurement of dose rate, radiation spectroscopy, tagging, tracking and inventorying of items. All data produced by the Platform are securely stored into the non-volatile memory of the RFID tags and in the database for both onsite and remote access to the information by operators. This paper presents the current development of the Platform and shows the advantages of such approach to achieve an easy yet reliable waste traceability, waste bagging optimization, and a structured methodology for radiation measurements, meeting an excellent quality control as increasingly required by Safety Authorities. Applications here envisaged and explored are dismantling and decontamination operations, radioprotection measurements and patrols, nuclear material management, safeguards and verification inspections. More in general, the Platform can address the needs of all plants, research laboratories and facilities that are looking to improve their Safety Standards, decrease operational costs, have a precise knowledge of the contaminated environment and objects as well as optimization for personnel dose minimization. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Strain annealing of SiC nanoparticles revealed through Bragg coherent diffraction imaging for quantum technologies

The crystalline strain properties of nanoparticles have broad implications in a number of emerging fields, including quantum and biological sensing in which heterogeneous internal strain fields are detrimental to performance. Here we used synchrotron-based Bragg coherent x-ray diffraction imaging (BCDI) to measure three-dimensional lattice strain fields within individual 3C-SiC nanoparticles, a candidate host material for quantum sensing, as a function of temperature during and after annealing up to 900 degrees C. We observed pronounced homogenization of the initial strain field at temperatures above 500 degrees C, and we find that the surface layers and central volumes of the nanoparticles reduce strain at similar rates, suggesting a uniform healing mechanism. Thus, we attribute the observed strain homogenization to activation of mobile point defects that annihilate and improve the overall quality of the crystal lattice. This work also establishes the feasibility of performing BCDI at high temperatures (up to 900 degrees C) to map structural hystereses relevant to the processing of quantum nanomaterials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study Thermographic Flaw Detection

The development of thermographic inspection methods for use on aerospace structures is under investigation. Several different material systems, structural geometries and defect types have been included in this study so as to establish a baseline from which future IRT testing can be made. This study examines various thermal loading techniques in an attempt to enhance the likelihood of capturing and identifying critically sized flaws under 'non-laboratory' actual working conditions. Qualification techniques and calibration standards are also being investigated to standardize the thermographic method. In conjunction with the thermographic inspections, advanced image processing techniques including digital filtering and neural networks have been investigated to increase the ability of 91 detecting and sizing flaws. Here, the digitized thermographic images are mathematically manipulated through various filtering techniques and/or artificial neural mapping schemes to enhance its overall quality, permitting accurate flaw identification even when the signal-to-noise ratio is low.

Walker, James L.↗

Study Thermographic Flaw Detection

The development of thermographic inspection methods for use on aerospace structures is under investigation. Several different material systems, structural geometries and defect types have been included in this study so as to establish a baseline from which future Infrared Thermography(IRT) testing can be made. This study examines various thermal loading techniques in an attempt to enhance the likelihood of capturing and identifying critically sized flaws under 'non laboratory' actual working conditions. Qualification techniques and calibration standards are also being investigated to standardize the thermographic method. In conjunction with the thermographic inspections, advanced image processing techniques including digital filtering and neural networks have been investigated to increase the ability of detecting and sizing flaws. Here, the digitized thermographic images are mathematically manipulated through various filtering techniques and/or artificial neural mapping schemes to enhance its overall quality, permitting accurate flaw identification even when the signal-to-noise ratio is low.

Walker, James L.↗

THE DESIGN OF LAYER TIME OPTIMIZATION IN LARGE SCALE ADDITIVE MANUFACTURING WITH FIBER REINFORCED POLYMER COMPOSITES

In this study, we have developed a method to optimize a layer deposition time (a.k.a. layer time) for large-scale additive manufacturing (AM) via physics-based simulations. A long layer time leads to an over-cooled surface on which a new layer is deposited, and therefore, it may result in a weak bonding or debonding between layers, cracking, or warping. A short layer time leads to a high temperature of the structure due to insufficient cooling, and therefore, the structure may not be stiff enough and may collapse during manufacturing. Therefore, it is important to estimate the optimal layer time in additive manufacturing for a high-quality product. The temperature of a top layer right before deposition is recommended to be slightly higher than the glass temperature of the material. A temperature cooling was approximated to an exponential function of time, and the optimized layer time was obtained based on a target temperature while maintaining a minimal printing time. The material used is carbon fiber-reinforced polycarbonate (CF/PC), and the large-scale deposition system used is LSAM TM from Thermwood Corporation. Three different layer time cases were used for experiments, and a series of thermal images were obtained via an infra-red (IR) camera during the entire AM processes. AM process simulations were performed using a finite element method and the temperature profiles from the simulation were in good agreement with those from experiments. The layer time optimization was performed based on the temperature profiles from the simulations. A layer temperature with the optimal layer time was confirmed as the target temperature through simulation.

Jo, Eonyeon↗

Interplay Between Plastic Deformations and Optical Properites of Metal Surfaces: A Multiscale Study

The design of metallic surfaces with required surface quality and visual appearance represents a significant challenge for scientists and engineers. For example, the surface of aluminum products such as reflector bright sheet, aerospace structural components, and architectural materials is always required to have an attractive appearance under different lighting conditions and to be free of defects and corrosion [ref. 1]. Industrial-scale modification processes of metal alloy products (heat treatment, rolling, stretching, extruding, etc.) are closely related to different plastic phenomena. Although plastic deformation takes place at the macroscopic level, it significantly changes the surface geometry at the meso- and microscopic scales which may result in spectacular modifications of visual appearance of the deformed surface. Here we use a combination of confocal optical microscopy, orientation imaging microscopy with electron back scattering diffraction (EBSD), original morphological image analysis approach developed by the authors, and finite element simulations, in order to investigate the interplay of different plastic instabilities emerging in the course of plastic deformation, and visual appearance. It is demonstrated that visual brightness of aluminum sheet products could be significantly suppressed by some widely used industrial processes such as uniaxial stretching of the sheet. On the other hand, a properly designed “texture rolling” (i.e., embossing additional controlled engineered features into the metal surface) makes it significantly brighter than a conventionally rolled surface because these features may serve as sinks for otherwise incompatible plastic deformations and enhance brightness due to the suppression of roughness. It is expected that such “imaging transitions” are of general nature and could be observed for different metals and alloys exhibiting plastic instabilities. In turn, these results provide guidelines for the control of metal surface morphology in order to achieve desirable visual appearance, such as visual brightness and omnidirectional coloration.

36 MATERIALS SCIENCE↗

Tilt generation in step-graded In{sub x}Ga{sub 1-x}As metamorphic pseudosubstrate on a singular GaAs substrate using a low-temperature grown InGaP interlayer

Metamorphic pseudosubstrates of In{sub 0.42}Ga{sub 0.58}As were grown by molecular beam epitaxy using step-graded In{sub x}Ga{sub 1-x}As buffer layers grown either directly on a (001) GaAs substrate or on a GaAs substrate overgrown with a layer of low-temperature grown In{sub 0.51}Ga{sub 0.49}P (LT-InGaP). The structures were examined using x-ray reciprocal space mapping to determine the characteristics of the pseudosubstrates and buffer layers. For the sample grown on the LT-InGaP layer, the pseudosubstrate exhibited an asymmetric tilt around [110] toward the [110] direction. Weak-beam dark-field electron imaging shows an imbalance of misfit dislocations with opposite sign Burgers vector. An explanation for this tilt is given and it is suggested that it may be responsible for the improved quality of epitaxial layers grown on such pseudosubstrates.

36 MATERIALS SCIENCE↗

Photonic devices fabricated from (111)‐oriented single crystal diamond

Abstract Diamond is a material of choice in the pursuit of integrated quantum photonic technologies. So far, the majority of photonic devices fabricated from diamond are made from (100)‐oriented crystals. In this work, we demonstrate a methodology for the fabrication of optically active membranes from (111)‐oriented diamond. We use a liftoff technique to generate membranes, followed by chemical vapor deposition of diamond in the presence of silicon to generate homogenous silicon vacancy color centers with emission properties that are superior to those in (100)‐oriented diamond. We further use the diamond membranes to fabricate microring resonators with quality factors exceeding ~ 3000. Supported by finite‐difference time‐domain calculations, we discuss the advantages of (111)‐oriented structures as building blocks for quantum nanophotonic devices. image

Regan, Blake↗

Image-Guided Radiotherapy for Cervix Cancer: High-Tech External Beam Therapy Versus High-Tech Brachytherapy

Purpose: Many studies comparing external-beam therapy (EBT) and brachytherapy (BT) are biased because advanced EBT is compared with conventional BT. This study compares high-tech EBT against high-tech BT. Methods and Materials: Nine patients were selected with locally advanced cervix cancer, representing typical clinical situations according to initial tumor extension and response after EBT. Patients were treated either with intracavitary, combined interstitial/intracavitary, or complex interstitial BT. Gross tumor volume, high-risk clinical target volume (CTV), intermediate-risk CTV, bladder, rectum, and sigmoid were delineated. Magnetic resonance-guided BT planning was manually optimized with respect to organ dose limits. Margins (3 and 5 mm) were added to BT CTVs to construct planning target volumes (PTVs) for EBT. Inversely planned EBT with photons (IMRT) and protons (IMPT) was challenged to deliver the highest possible doses to PTVs while respecting D{sub 1cc} and D{sub 2cc} limits from BT, assuming the same fractionation (4 x 7 Gy). The D90 for target structures and normal tissue volumes receiving fractionated doses between 3 and 7 Gy were compared. Results: High-risk CTV doses depended on the clinical situation and radiation quality. If IMRT was limited to D{sub 2cc} and D{sub 1cc} from BT, the D90 for high-risk PTV and intermediate-risk PTV was mostly lower. Volumes receiving 60 Gy (in equivalent dose in 20 Gy fractions) were approximately twice as large for IMRT compared with BT. For IMPT, this volume ratio was lower. Planning target volume doses of IMPT plans with 3-mm margins were comparable to those with BT. Gross tumor volume doses were mostly lower for both IMRT and IMPT. Conclusion: For benchmarking high-tech EBT, high-tech BT techniques have to be used. For cervix cancer boost treatments, both IMRT and IMPT seem to be inferior to advanced BT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Structural and optical properties of zinc oxide film using RF-sputtering technique

This paper reports the fabrication of zinc oxide (ZnO) film using RF-sputtering technique. Determination of the structural properties using High Resolution X-ray Diffraction (HRXRD) confirmed that ZnO film deposited on silicon (Si) substrate has a high quality. This result is in line with the Scanning Electron Microscopy (SEM) and Atomic Force Microscopy (AFM) which were used to image the morphology of the film, in which a rough surface was demonstrated. Photoluminescence (PL) emission is included to study the optical properties of ZnO film that shows two PL peak in the UV region at 371 nm and in visible region at 530 nm respectively.

36 MATERIALS SCIENCE↗