Search NASA⌕ Search

SEARCH · Search NASA

Results for “image spectrometer instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

On the Hunt for Detectable Biosignatures in Jezero Crater: What to Look for and Where

Introduction: The Perseverance rover, which is currently exploring Jezero crater on Mars, is equipped with seven instruments that allow for observation of textures, minerals, color, structure, and chemistry of rocks and sediments in order to search for signs of ancient life, understand the geologic history of the crater, and identify candidates for sample return (Farley et al. 2020). The first of these aims includes the direct detection of potential biosignatures, including textures, organic molecules, minerals, and elemental chemistries that are of biogenic origin (Mustard et al. 2013). The presence of these biosignatures will be constrained by the habitability of the local region, the preservation potential of the host rocks, and the sensitivity of the instrument suite, and their biogenicity will be investigated after return to Earth as part of the Mars Sample Return campaign. Here, we examine key targets on the three planned campaigns, potential biosignatures that may be present, and the capabilities of key rover instruments. High Potential Biosignature Sites in Jezero: To date, measurements have been made on multiple sites that both contain minerals known in terrestrial settings to preserve biosignatures and likely were habitable settings (Williford et al. 2021). Two examples include the fine-grained rocks at the base of the delta fan and the NW inner margin of the crater. Fine-grained Rocks at Base of Delta Fan. Fine-grained, clay-bearing rocks may have been deposited as muddy lake sediments that could have hosted life and preserved biosignatures settling out of the water column. The report of organic molecules by the Curiosity rover in the Sheepbed mudstone and Murray formation has highlighted this site in particular. Potential biosignatures in mudstones, especially those rich in silica (McMahon et al. 2018), microbialites and complex organics. NW Inner Margin of Crater. This unit, located along the inner margin of the crater, contains strong carbonate signatures and may have been the littoral zone of a lake (Horgan et al. 2020). The potential biosignatures here include microfossils, microbialites, biominerals, and complex organics. Detectability of Biosignatures by the Mars 2020 Instrument Suite: The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) instrument comprises a Deep UV spectrometer, context imager, and color camera to generate spatially resolved chemical maps (Bhartia et al. 2020). It is sensitive to trace organics as well as a range of minerals and can detect native fluorescence from aromatic organics; the WATSON and ACI cameras can be used to observe morphologies such as stromatolitic laminations or filaments ranging from the tens of micron to millimeter scale. SHERLOC can detect organics that may be present in either of the high potential biosignature targets, as well as detect carbonates in the latter. However, the presence of high amounts of iron, such as in iron-rich clays, would cause attenuation of spectral response through UV absorption. The Planetary Instrument for X-ray Lithochemistry (PIXL) comprises an X-ray fluorescence spectrometer and camera that can scan rock surfaces to generate elemental maps (Allwood et al. 2020). PIXL can detect chemical biosignatures such as spatial variations of elemental abundances that may have resulted from biological activity. PIXL would be particularly useful in detecting fine textures and elemental chemistries in either high potential biosignature target, but cannot directly detect minerals such as carbonate. The SuperCam instrument performs three types of spectroscopy, color imaging, and acoustic recording to remotely examine elemental composition, minerals, organics, and textures (Maurice et al. 2021). Using laser induced breakdown spectroscopy and time resolved luminescence spectroscopy, SuperCam can detect major elemental building blocks of organics (i.e., C, H, N, O, P, S) and conjugated organic structures, respectively, which may be found in either site. While in other contexts, luminescence is a useful tool for biosignature identification, luminescence generated by the 532 nm laser may obscure the Raman signal. Conclusion: The three instruments discussed can be used collaboratively to establish the presence of potential biosignatures in samples. These high-priority samples may then be returned to Earth for detailed laboratory analysis.

S. Sharma↗

The Gamma-Ray Imaging Spectrometer (GRIS): A new balloon-borne experiment for gamma-ray line astronomy

High resolution gamma-ray spectroscopy is a relatively new field that holds great promise for further understanding of high energy astrophysical processes. When the high resolution gamma-ray spectrometer (GRSE) was removed from the GRO payload, a balloon program was initiated to permit continued development and improvement of instrumentation in this field, as well as continued scientific observations. The Gamma-Ray Imaging Spectrometer (GRIS) is one of the experiments selected as part of this program. The instrument contains a number of new and innovative features that are expected to produce a significant improvement in source location accuracy and sensitivity over previous balloon and satellite experiments.

Teegarden, B. J.↗

Robotic Subsurface Analyzer and Sample Handler for Resource Reconnaissance and Preliminary Site Assessment for ISRU Activities at the Lunar Cold Traps

Since the 1960s, claims have been made that water ice deposits should exist in permanently shadowed craters near both lunar poles. Recent interpretations of data from the Lunar Prospector-Neutron Spectrometer (LP- NS) confirm that significant concentrations of hydrogen exist, probably in the form of water ice, in the permanently shadowed polar cold traps. Yet, due to the large spatial resolution (45-60 Ian) of the LP-NS measurements relative to these shadowed craters (approx.5-25 km), these data offer little certainty regarding the precise location, form or distribution of these deposits. Even less is known about how such deposits of water ice might effect lunar regolith physical properties relevant to mining, excavation, water extraction and construction. These uncertainties will need to be addressed in order to validate fundamental lunar In Situ Resource Utilization (ISRU) precepts by 2011. Given the importance of the in situ utilization of water and other resources to the future of space exploration a need arises for the advanced deployment of a robotic and reconfigurable system for physical properties and resource reconnaissance. Based on a collection of high-TRL. designs, the Subsurface Analyzer and Sample Handler (SASH) addresses these needs, particularly determining the location and form of water ice and the physical properties of regolith. SASH would be capable of: (1) subsurface access via drilling, on the order of 3-10 meters into both competent targets (ice, rock) and regolith, (2) down-hole analysis through drill string embedded instrumentation and sensors (Neutron Spectrometer and Microscopic Imager), enabling water ice identification and physical properties measurements; (3) core and unconsolidated sample acquisition from rock and regolith; (4) sample handling and processing, with minimized contamination, sample containerization and delivery to a modular instrument payload. This system would be designed with three mission enabling goals, including: (1) a self-contained, low power, low mass, "black box'' configuration for operations from a lander, various classes of rovers or a surface-based platform with human assistance or robotic anchoring mechanisms; (2) reconfigurable and scalable sample handling for delivery to various types of instrumentation, depending on mission requirements; and (3) the use of advanced automation control and diagnostic techniques that will afford local human deployed, remote teleoperation and fully autonomous intelligent operations. Though a great deal of technology has been advanced toward these objectives, the SASH system faces significant design challenges, including the low gravity environment, various levels of autonomy in operations, radiation exposure, dust contamination, and temperature extremes and deltas. Significant input from the scientific and engineering communities, as well as a significant environmental testing program, will be required to guide the design process.

Gorevan, S. P.↗

Synegies Between Visible/Near-Infrared Imaging Spectrometry and the Thermal Infrared in an Urban Environment: An Evaluation of the Hyperspectral Infrared Imager (HYSPIRI) Mission

A majority of the human population lives in urban areas and as such, the quality of urban environments is becoming increasingly important to the human population. Furthermore, these areas are major sources of environmental contaminants and sinks of energy and materials. Remote sensing provides an improved understanding of urban areas and their impacts by mapping urban extent, urban composition (vegetation and impervious cover fractions), and urban radiation balance through measures of albedo, emissivity and land surface temperature (LST). Recently, the National Research Council (NRC) completed an assessment of remote sensing needs for the next decade (NRC, 2007), proposing several missions suitable for urban studies, including a visible, near-infrared and shortwave infrared (VSWIR) imaging spectrometer and a multispectral thermal infrared (TIR) instrument called the Hyperspectral Infrared Imagery (HyspIRI). In this talk, we introduce the HyspIRI mission, focusing on potential synergies between VSWIR and TIR data in an urban area. We evaluate potential synergies using an Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) and MODIS-ASTER (MASTER) image pair acquired over Santa Barbara, United States. AVIRIS data were analyzed at their native spatial resolutions (7.5m VSWIR and 15m TIR), and aggregated 60 m spatial resolution similar to HyspIRI. Surface reflectance was calculated using ACORN and a ground reflectance target to remove atmospheric and sensor artifacts. MASTER data were processed to generate estimates of spectral emissivity and LST using Modtran radiative transfer code and the ASTER Temperature Emissivity Separation algorithm. A spectral library of common urban materials, including urban vegetation, roofs and roads was assembled from combined AVIRIS and field-measured reflectance spectra. LST and emissivity were also retrieved from MASTER and reflectance/emissivity spectra for a subset of urban materials were retrieved from co-located MASTER and AVIRIS pixels. Fractions of Impervious, Soil, Green Vegetation (GV) and Non-photosynthetic Vegetation (NPV), were estimated using Multiple Endmember Spectral Mixture Analysis (MESMA) applied to AVIRIS data at 7.5, 15 and 60 m spatial scales. Surface energy parameters, including albedo, vegetation cover fraction, broadband emissivity and LST were also determined for urban and natural land-cover classes in the region. Fractions were validated using 1m digital photography.

Roberts, Dar A.↗

The Viking biology results

A brief review of the purposes and the results from the Viking Biology experiments is presented, in the expectation that the lessons learned from this mission will be useful in planning future approaches to the biological exploration of Mars. Since so little was then known about potential micro-environments on Mars, three different experiments were included in the Viking mission, each one based on different assumptions about what Martian organisms might be like. In addition to the Viking Biology Instrument (VBI), important corollary information was obtained from the Viking lander imaging system and from the molecular analysis experiments that were conducted using the gas chromatograph-mass spectrometer (GCMS) instrument. No biological objects were noted by the lander imaging instrument. The GCMS did not detect any organic compounds. A description of the tests conducted by the Gas Exchange Experiment, the Labeled Release experiment, and the Pyrolytic Release experiment is given. Results are discussed. Taken as a whole, the Viking data yielded no unequivocal evidence for a Martian biota at either landing site. The results also revealed the presence of one or more reactive oxidants in the surface material and these need to be further characterized, as does the range of micro-environments, before embarking upon future searches for extant life on Mars.

Klein, Harold P.↗

On-Orbit Performance of the TES Pulse Tube Cryocooler System and the Instrument - Six Years in Space

The Tropospheric Emission Spectrometer (TES) instrument pulse tube cryocoolers began operation 36 days after launch of the NASA Earth Observing System (EOS) Aura spacecraft on July 15, 2004. TES is designed with four infrared Mercury Cadmium Telluride focal plane arrays in two separate housings cooled by a pair of Northrup Grumman Aerospace Systems (NGAS) single-stage pulse tube cryocoolers. The instrument also makes use of a two-stage passive cooler to cool the optical bench. The instrument is a high-resolution infrared imaging Fourier transform spectrometer with 3.3-15.4 micron spectral coverage. After four weeks of outgassing, the instrument optical bench and focal planes were cooled to their operating temperatures to begin science operations. During the early months of the mission, ice contamination of the cryogenic surfaces including the focal planes led to increased cryocooler loads and the need for periodic decontamination cycles. After a highly successful 5 years of continuous in-space operations, TES was granted a 2 year extension. This paper reports on the TES cryogenic system performance including the two-stage passive cooler. After a brief overview of the cryogenic design, the paper presents detailed data on the highly successful space operation of the pulse tube cryocoolers and instrument thermal design over the past six years since the original turn-on in 2004. The data shows the cryogenic contamination decreased substantially to where decontamination cycles are now performed every six months. The cooler stroke required for constant-temperature operation has not increased indicating near-constant cooler efficiency and the instrument's thermal design has also provided a nearly constant heat rejection sink. At this time TES continues to operate in space providing important Earth science data.

cryocoolercraft↗

Common Calibration Source for Monitoring Long-term Ozone Trends

Accurate long-term satellite measurements are crucial for monitoring the recovery of the ozone layer. The slow pace of the recovery and limited lifetimes of satellite monitoring instruments demands that datasets from multiple observation systems be combined to provide the long-term accuracy needed. A fundamental component of accurately monitoring long-term trends is the calibration of these various instruments. NASA s Radiometric Calibration and Development Facility at the Goddard Space Flight Center has provided resources to minimize calibration biases between multiple instruments through the use of a common calibration source and standardized procedures traceable to national standards. The Facility s 50 cm barium sulfate integrating sphere has been used as a common calibration source for both US and international satellite instruments, including the Total Ozone Mapping Spectrometer (TOMS), Solar Backscatter Ultraviolet 2 (SBUV/2) instruments, Shuttle SBUV (SSBUV), Ozone Mapping Instrument (OMI), Global Ozone Monitoring Experiment (GOME) (ESA), Scanning Imaging SpectroMeter for Atmospheric ChartographY (SCIAMACHY) (ESA), and others. We will discuss the advantages of using a common calibration source and its effects on long-term ozone data sets. In addition, sphere calibration results from various instruments will be presented to demonstrate the accuracy of the long-term characterization of the source itself.

Kowalewski, Matthew↗

Physically-Retrieving Cloud and Thermodynamic Parameters from Ultraspectral IR Measurements

A physical inversion scheme has been developed, dealing with cloudy as well as cloud-free radiance observed with ultraspectral infrared sounders, to simultaneously retrieve surface, atmospheric thermodynamic, and cloud microphysical parameters. A fast radiative transfer model, which applies to the clouded atmosphere, is used for atmospheric profile and cloud parameter retrieval. A one-dimensional (1-d) variational multi-variable inversion solution is used to improve an iterative background state defined by an eigenvector-regression-retrieval. The solution is iterated in order to account for non-linearity in the 1-d variational solution. It is shown that relatively accurate temperature and moisture retrievals can be achieved below optically thin clouds. For optically thick clouds, accurate temperature and moisture profiles down to cloud top level are obtained. For both optically thin and thick cloud situations, the cloud top height can be retrieved with relatively high accuracy (i.e., error < 1 km). NPOESS Airborne Sounder Testbed Interferometer (NAST-I) retrievals from the Atlantic-THORPEX Regional Campaign are compared with coincident observations obtained from dropsondes and the nadir-pointing Cloud Physics Lidar (CPL). This work was motivated by the need to obtain solutions for atmospheric soundings from infrared radiances observed for every individual field of view, regardless of cloud cover, from future ultraspectral geostationary satellite sounding instruments, such as the Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS) and the Hyperspectral Environmental Suite (HES). However, this retrieval approach can also be applied to the ultraspectral sounding instruments to fly on Polar satellites, such as the Infrared Atmospheric Sounding Interferometer (IASI) on the European MetOp satellite, the Cross-track Infrared Sounder (CrIS) on the NPOESS Preparatory Project and the following NPOESS series of satellites.

Zhou, Daniel K.↗

Theory and Development of Position-Sensitive Quantum Calorimeters

Quantum calorimeters are being developed as imaging spectrometers for future X-ray astrophysics observatories. Much of the science to be done by these instruments could benefit greatly from larger focal-plane coverage of the detector (without increasing pixel size). An order of magnitude more area will greatly increase the science throughput of these future instruments. One of the main deterrents to achieving this goal is the complexity of the readout schemes involved. We have devised a way to increase the number of pixels from the current baseline designs by an order of magnitude without increasing the number of channels required for readout. The instrument is a high energy resolution, distributed-readout imaging spectrometer called a Position-Sensitive Transition-Edge Sensor (POST). A POST is a quantum calorimeter consisting of two Transition-Edge Sensors (TESS) on the ends of a long absorber capable of one-dimensional imaging spectroscopy. Comparing rise time and energy information from the two TESS, the position of the event in the POST is determined. The energy of the event is inferred from the sum of the two pulses. We have developed a generalized theoretical formalism for distributed-readout calorimeters and apply it to our devices. We derive the noise theory and calculate the theoretical energy resolution of a POST. Our calculations show that a 7-pixel POST with 6 keV saturation energy can achieve 2.3 eV resolution, making this a competitive design for future quantum calorimeter instruments. For this thesis we fabricated 7- and 15-pixel POSTS using Mo/Au TESs and gold absorbers, and moved from concept drawings on scraps of napkins to a 32 eV energy resolution at 1.5 keV, 7-pixel POST calorimeter.

Figueroa-Feliciano, Enectali↗

Development of the instruments for the Gamma Ray Observatory

The Gamma Ray Observatory (GRO) is to be launched in 1988 by the STS. The GRO will feature four very large instruments: the Oriented Scintillation Spectrometer Experiment (OSSE), the Imaging Compton Telescope (COMPTEL), the Energetic Gamma Ray Experiment Telescope (EGRET) and the Burst and Transient Source Experiment (BATSE). The instruments weigh from 900-1200 kg each, and required the development of specialized lifting and dolly devices to permit their assembly, manipulation and testing. The GRO is intended a{s a tool for studying discrete celestial objects such as black holes, neutron stars and other gamma-ray emitting objects, scanning for nucleosynthesis processes, mapping the Galaxy and other, high energy galaxies in terms of gamma rays, searching for cosmological effects and observing gamma ray bursts. The instruments will be sensitive from the upper end mof X-rya wavelengths to the highest energies possible. Details of the hardware and performance specifications of each of the instruments are discussed.

Madden, J. J.↗

AVIRIS onboard data handling and control

The timing and flow of detector and ancillary data for the Airborne Visible/Infrared imaging spectrometer (AVIRIS) are controlled within the instrument by its digital electronics assembly. In addition to providing detector and signal chain timing, the digital electronics receives, formats, and rate-buffers digitized science data; collects and formats ancillary (calibration and engineering) data; and merges both into a single tape record. Overall AVIRIS data handling is effected by a combination of dedicated digital electronics to control instrument timing, image data flow, and data rate buffering and a microcomputer programmed to handle real-time control of instrument mechanisms and the coordinated preparation of ancillary data.

Steinkraus, Ronald E.↗

AVIRIS onboard data handling and control

The timing and flow of detector and ancillary data for the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) are controlled within the instrument by its digital electronics assembly. In addition to providing detector and signal chain timing, the digital electronics receives, formats, and rate-buffers digitized science data; collects and formats ancillary (calibration and engineering) data; and merges both into a single tape record. Overall AVIRIS data handling is effected by a combination of dedicated digital electronics to control instrument timing, image data flow, and data rate buffering and a microcomputer programmed to handle real-time control of instrument mechanisms and the coordinated preparation of ancillary data.

Steinkraus, Ronald E.↗

A Status of U-Class Earth Science Instruments at JPL

With advancements in CubeSat technologies and low-cost launch opportunities, CubeSats could play a role in meeting NASA’s key Earth science measurement objectives, especially in extreme weather and ecosystem processes. In this paper, we discuss the development of “science grade” hyperspectral imager, microwave spectrometer, IR sounder, and Ka-band radar instruments at JPL. They are scheduled to launch in early to late 2018 while the hyperspectral imager is being developed for airborne flights and for space in the future. The limitations in power, mass, and volume imposed by the CubeSat platform required the identification of new technologies in order to miniaturize instruments into a specific form factor. In conclusion, we will summarize strategies to implement small and low-cost instruments and suggest an architecture for enabling a constellation of U-class instruments.

Hyon, Jason J.↗

HIRIS - The High Resolution Imaging Spectrometer

The High-Resolution Imaging Spectrometer (HIRIS) is a JPL facility instrument designed for NASA's Earth Observing System (Eos).It will have 10-nm wide spectral bands from 0.4-2.5 microns at 30 m spatial resolution over a 30 km swath. The spectral resolution allows identification of many minerals in rocks and soils, important algal pigments in oceans and inland waters, spectral changes associated with plant canopy biochemistry, composition of atmospheric aerosols, and grain size of snow and its contamination by absorbing impurities. The bands wil have 12-bit quantization over a dynamic range suitable for bright targets, such as snow. For targets of low brightness, such as water bodies, image-motion compensation will allow gains up to a factor of eight to increase signal-to-noise ratios. In the 824-km orbit altitude proposed for Eos, the crosstrack pointing capability will allow 4-5 views during a 16-day revisit cycle.

Dozier, Jeff↗

Global Patterns of Tectonism on Titan from Mountain Chains and Virgae

This research is based on the exploration of tectonic patterns on Titan from a global perspective. Several moons in the outer solar system display patterns of surface tectonic features that imply global stress fields driven or modified by global forces. Patterns such as these are seen in Europa's tidally induced fracture patterns, Enceladus's tiger stripes, and Ganymede's global expansion induced normal fault bands. Given its proximity to Saturn, as well as its eccentric orbit, tectonic features and global stresses may be present on Titan as well. Titan displays possible tectonic structures, such as mountain chains along its equator (Radebaugh et al. 2007), as well as the unexplored dark linear streaks termed virgae by the IAU. Imaged by Cassini with the RADAR instrument, mountain chains near the equator are observed with a predominante east-west orientation (Liu et al. 2012, Mitri et al. 2010). Orientations such as these can be explained by modifications in the global tidal stress field induced by global contraction followed by rotational spin-up. Also, due to Titan's eccentric orbit, its current rotation rate may be in an equilibrium between tidal spin-up near periapsis and spin-down near apoapsis (Barnes and Fortney 2003). Additional stress from rotational spin-up provides an asymmetry to the stress field. This, combined with an isotropic stress from radial contraction, favors the formation of equatorial mountain chains in an east-west direction. The virgae, which have been imaged by Cassini with both the Visual and Infrared Mapping Spectrometer (VIMS) and Imaging Science Subsystem (ISS) instruments, are located predominately near 30 degrees latitude in either hemisphere. Oriented with a pronounced elongation in the east-west direction, all observed virgae display similar characteristics: similar relative albedos as the surrounding terrain however darkened with an apparent neutral absorber, broken-linear or rounded sharp edges, and connected, angular elements with distinct, linear edges. Virgae imaged during northern latitude passes are oriented with their long dimensions toward Titan's antiSaturn point. If the virgae are of tectonic origin, for instance if the turn out to be i.e. grabens, they could serve as markers to Titan's global stress field. Using them in this way allows for a mapping of global tectonic patterns. These patterns will be tested for consistency against the various sources of global stress and orientations of mountain chains. By determining what drives Titan's tectonics globally, we will be able to place Titan within the context of the other outer planet icy satellites.

Cook, C.↗

Global spectroscopy and imaging of atmospheric X-ray bremsstrahlung - Instrumentation and initial results from the PEM/AXIS instrument aboard the Upper Atmosphere Research Satellite

The Atmospheric X-ray Imaging Spectrometer (PEM/AXIS) aboard NASA's Upper Atmosphere Research Satellite provides continuous horizon to horizon images, both day and night, of the 3- to 100-keV X-ray flux emitted from the top of the atmosphere. AXIS achieves a spatial resolution to better than 100 km using a one-dimensional array of 16 passively cooled silicon detectors. The primary purpose of this instrument is to provide a global monitor of electron energy input to the upper atmosphere. We describe the design, development, and calibration of AXIS and provide an assessment of its excellent on-orbit performance. The unique capabilities of X-ray imaging spectrometers are demonstrated through an analysis of specific examples from October and November 1991. Important new developments for follow-on instruments also will be described.

Chenette, D. L.↗

Field observations using an AOTF polarimetric imaging spectrometer

This paper reports preliminary results of recent field observations using a prototype acousto-optic tunable filter (AOTF) polarimetric imaging spectrometer. The data illustrate application potentials for geoscience. The operation principle of this instrument is different from that of current airborne multispectral imaging instruments, such as AVIRIS. The AOTF instrument takes two orthogonally polarized images at a desired wavelength at one time, whereas AVIRIS takes a spectrum over a predetermined wavelength range at one pixel at a time and the image is constructed later. AVIRIS does not have any polarization measuring capability. The AOTF instrument could be a complement tool to AVIRIS. Polarization measurement is a desired capability for many applications in remote sensing. It is well know that natural light is often polarized due to various scattering phenomena in the atmosphere. Also, scattered light from canopies is reported to have a polarized component. To characterize objects of interest correctly requires a remote sensing imaging spectrometer capable of measuring object signal and background radiation in both intensity and polarization so that the characteristics of the object can be determined. The AORF instrument has the capability to do so. The AOTF instrument has other unique properties. For example, it can provide spectral images immediately after the observation. The instrument can also allow observations to be tailored in real time to perform the desired experiments and to collect only required data. Consequently, the performance in each mission can be increased with minimal resources. The prototype instrument was completed in the beginning of this year. A number of outdoor field experiments were performed with the objective to evaluate the capability of this new technology for remote sensing applications and to determine issues for further improvements.

Cheng, Li-Jen↗

Filling-In of Broad Far-Red Solar Lines by Terrestrial Fluorescence and Atmospheric Raman Scattering as Detected by SCIAMACHY Satellite Measurements

Global mapping of terrestrial vegetation fluorescence from space has recently been accomplished with high spectral resolution measurements from the Japanese Greenhouse gases Observing SATellite (GOSAT). These data are of interest because they can potentially provide global information on the functional status of vegetation including light use efficiency and global primary productivity that can be used for global carbon cycle modeling. Quantifying the impact of fluorescence on the O2-A band is important as this band is used for cloud- and aerosol-characterization for other trace-gas retrievals including CO2. Here, we demonstrate that fluorescence information can be derived from space using potentially lower-cost hyperspectral instrumentation, i.e., more than an order of magnitude less spectral resolution than GOSAT, with a relatively simple algorithm. As a demonstration, we use the filling-in of one of the few wide and deep solar Fraunhofer lines in the red and far-red chlorophylla fluorescence bands, the calcium II line near 866 nm, to retrieve fluorescence with the SCanning Imaging Absorption spectroMeter for Atmospheric CHartographY (SCIAMACHY) satellite instrument. Although the signal from vegetation fluorescence is extremely weak at 866 nm, our results suggest that useful information may be obtained after adjustments are made to the observed spectra to correct for instrumental artifacts. We compare fluorescence from SCIAMACHY with that retrieved at 758 and 770 nm from similarly-corrected GOSAT data as well with the Enhanced Vegetation Index (EVI) from the MODerate-resolution Imaging Spectroradiometer (MODIS). We also show that filling-in occurs at 866 nm over barren areas, possibly originating from luminescent minerals in rock and soil.

Joiner, J.↗