Rover imaging system for the Mars rover/sample return mission

In the past year, the conceptual design of a panoramic imager for the Mars Environmental Survey (MESUR) Pathfinder was finished. A prototype camera was built and its performace in the laboratory was tested. The performance of this camera was excellent. Based on this work, we have recently proposed a small, lightweight, rugged, and highly capable Mars Surface Imager (MSI) instrument for the MESUR Pathfinder mission. A key aspect of our approach to optimization of the MSI design is that we treat image gathering, coding, and restoration as a whole, rather than as separate and independent tasks. Our approach leads to higher image quality, especially in the representation of fine detail with good contrast and clarity, without increasing either the complexity of the camera or the amount of data transmission. We have made significant progress over the past year in both the overall MSI system design and in the detailed design of the MSI optics. We have taken a simple panoramic camera and have upgraded it substantially to become a prototype of the MSI flight instrument. The most recent version of the camera utilizes miniature wide-angle optics that image directly onto a 3-color, 2096-element CCD line array. There are several data-taking modes, providing resolution as high as 0.3 mrad/pixel. Analysis tasks that were performed or that are underway with the test data from the prototype camera include the following: construction of 3-D models of imaged scenes from stereo data, first for controlled scenes and later for field scenes; and checks on geometric fidelity, including alignment errors, mast vibration, and oscillation in the drive system. We have outlined a number of tasks planned for Fiscal Year '93 in order to prepare us for submission of a flight instrument proposal for MESUR Pathfinder.

Source record↗

Heart Imaging System

Johnson Space Flight Center's device to test astronauts' heart function in microgravity has led to the MultiWire Gamma Camera, which images heart conditions six times faster than conventional devices. Dr. Jeffrey Lacy, who developed the technology as a NASA researcher, later formed Proportional Technologies, Inc. to develop a commercially viable process that would enable use of Tantalum-178 (Ta-178), a radio-pharmaceutical. His company supplies the generator for the radioactive Ta-178 to Xenos Medical Systems, which markets the camera. Ta-178 can only be optimally imaged with the camera. Because the body is subjected to it for only nine minutes, the radiation dose is significantly reduced and the technique can be used more frequently. Ta-178 also enables the camera to be used on pediatric patients who are rarely studied with conventional isotopes because of the high radiation dosage.

Source record↗

Highly Protable Airborne Multispectral Imaging System

A portable instrumentation system is described that includes and airborne and a ground-based subsytem. It can acquire multispectral image data over swaths of terrain ranging in width from about 1.5 to 1 km. The system was developed especially for use in coastal environments and is well suited for performing remote sensing and general environmental monitoring. It includes a small,munpilotaed, remotely controlled airplance that carries a forward-looking camera for navigation, three downward-looking monochrome video cameras for imaging terrain in three spectral bands, a video transmitter, and a Global Positioning System (GPS) reciever.

Lehnemann, Robert↗

Analysis of spatial pseudodepolarizers in imaging systems

The objective of a number of optical instruments is to measure the intensity accurately without bias as to the incident polarization state. One method to overcome polarization bias in optical systems is the insertion of a spatial pseudodepolarizer. Both the degree of depolarization and image degradation (from the polarization aberrations of the pseudodepolarizer) are analyzed for two depolarizer designs: (1) the Cornu pseudodepolarizer, effective for linearly polarized light, and (2) the dual Babinet compensator pseudodepolarizer, effective for all incident polarization states. The image analysis uses a matrix formalism to describe the polarization dependence of the diffraction patterns and optical transfer function.

Mcguire, James P., Jr.↗

New Method for Calibration for Hyperspectral Pushbroom Imaging Systems

A new, easy-to-implement approach for achieving highly accurate spectral and radiometric calibration of array-based, hyperspectral pushbroom imagers is presented in this paper. The equivalence of the plane of the exit port of an integrating sphere to a Lambertian surface is utilized to provide a field-filling radiance source for the imager. Several different continuous wave lasers of various wavelengths and a quartz-tungsten-halogen lamp internally illuminate the sphere. The imager is positioned to "stare" into the port, and the resultant data cube is analyzed to determine wavelength calibrations, spectral widths of channels, radiometric characteristics, and signal-to-noise ratio, as well as an estimate of signal-to-noise performance in the field. The "smile" (geometric distortion of spectra) of the system can be quickly ascertained using this method. As the price and availability of solid state laser sources improve, this technique could gain wide acceptance.

Ryan, Robert↗

Advanced scanners and imaging systems for earth observations

Assessments of present and future sensors and sensor related technology are reported along with a description of user needs and applications. Five areas are outlined: (1) electromechanical scanners, (2) self-scanned solid state sensors, (3) electron beam imagers, (4) sensor related technology, and (5) user applications. Recommendations, charts, system designs, technical approaches, and bibliographies are included for each area.

Source record↗

Improving the geometric fidelity of imaging systems employing sensor arrays

A sensor assembly to be carried on an aircraft or spacecraft which will travel along an arbitrary flight path, for providing an image of terrain over which the craft travels, is disclosed. The assembly includes a main linear sensor array and a plurality of auxiliary sensor arrays oriented parallel to, and at respectively different distances from, the main array. By comparing the image signals produced by the main sensor array with those produced by each auxiliary array, information relating to variations in velocity of the craft carrying the assembly can be obtained. The signals from each auxiliary array will provide information relating to a respectively different frequency range.

Jones, Kenneth L.↗

Apparent limitations of head-up-displays and thermal imaging systems

A simulated helicopter flight through a slalom course was presented on a Silicon Graphics IRIS 3130. The display represented the major visual characteristics of thermal images. Subjects were asked to maintain a designated altitude, while flying a slalom course between regularly spaced pylons. The presence of some of the high frequency details in the image improved subjects' ability to reach and maintain the correct altitude. A head-up-display helped in maintaining altitude, but impaired maneuvering around the poles. The results are interpreted in terms of the competition for visual resources between the HUD and the world view.

Brickner, Michael S.↗

Geometric fiedlity of imaging systems employing sensor arrays

A sensor assembly to be carried on an aircraft or spacecraft which will travel along an arbitrary flight path, for providing an image of terrain over which the craft travels. The assembly includes a main linear sensor array and a plurality of auxiliary sensor arrays oriented parallel to, and at respectively different distances from, the main array. By comparing the image signals produced by the main sensor array with those produced by each auxiliary array, information relating to variations in velocity of the craft carrying the assembly can be obtained. The signals from each auxiliary array will provide information relating to a respectively different frequency range.

Jones, Kenneth L.↗

Survey of candidate gamma-ray sources at TeV energies using a high-resolution Cerenkov imaging system - 1988-1991

The steady TeV gamma-ray emission from the Crab Nebula has been used to optimize the sensitivity of the Whipple Observatory atmospheric Cerenkov imaging telescope. Using this method, which is of order 20 times more sensitive than the standard method using a simple non-imaging detector, it is possible to detect the Crab Nebula at a significance level in excess of 6 standard deviations (6 sigma) in under 1 hr on source (with a corresponding time observing a background comparison region); a source one-tenth the strength of the Crab Nebula can be detected at the 4 sigma level after 40 hr on the source (and 40 hr on a background region). A variety of sources have been monitored using this technique over the period 1988-1991, but none were detected apart from the Crab Nebula. Upper limits are presented which in many instances are a factor of 10 below the flux of the Crab Nebula. These upper limits assume steady emission from the source and cannot rule out sporadic gamma-ray emission with short duty cycles.

Reynolds, P. T.↗

Development of Next Generation Lifetime PSP Imaging Systems

This paper describes a lifetime PSP system that has recently been developed using pulsed light-emitting diode (LED) lamps and a new interline transfer CCD camera technology. This system alleviates noise sources associated with lifetime PSP systems that use either flash-lamp or laser excitation sources and intensified CCD cameras for detection. Calibration curves have been acquired for a variety of PSP formulations using this system, and a validation test was recently completed in the Subsonic Aerodynamic Research Laboratory (SARL) at Wright-Patterson Air Force Base (WPAFB). In this test, global surface pressure distributions were recovered using both a standard intensity-based method and the new lifetime system. Results from the lifetime system agree both qualitatively and quantitatively with those measured using the intensity-based method. Finally, an advanced lifetime imaging technique capable of measuring temperature and pressure simultaneously is introduced and initial results are presented.

Watkins, A. Neal↗

Compact Mid-Wave Imaging System (CMIS) for Retrieval of Cloud Motion Vectors and Cloud Geometric Heights

The Johns Hopkins University Applied Physics Laboratory (JHU/APL) is developing a compact, light-weight, and low power midwave-infrared (MWIR) imager called the Compact Midwave Imaging Sensor (CMIS), under the support of the NASA Earth Science Technology Office Instrument Incubator Program. The goal of this CMIS instrument development and demonstration project is to increase the technical readiness of CMIS, a multi-spectral sensor capable of retrieving 3D winds and cloud heights 24/7, for a space mission. The CMIS instrument employs an advanced MWIR detector that requires less cooling than traditional technologies and thus permits a compact, low-power design, which enables accommodation on small spacecraft such as CubeSats. CMIS provides the critical midwave component of a multi-spectral sensor suite that includes a high-resolution Day-Night Band and a longwave infrared (LWIR) imager to provide global cloud characterization and theater weather imagery. In this presentation, an overview of the CMIS project, including the high-level sensor design, the concept of operations, and measurement capability will be presented. System performance for a variety of different scenes generated by a cloud resolving model (CRM) will also be discussed.

midwave↗

Multispectral Imaging Systems Using Acousto-Optic Tunable Filter

This paper discusses recent activities of Jet Propulsion Laboratory (JPL) in the development of a new type of remote sensing multispectral imaging instruments using acousto-optic tunable filter (AOTF) as programmable bandpass filter. This remote sensor provides real-time operation; observational flexibility; measurements of spectral, spatial, and polarization information using a single insturment; and compact, solid state structure without moving parts.

Multispectral↗

The utilization of an infrared imaging system as a cooling slot blockage detector in the inspection of a transpiration cooled nozzle

A comprehensive examination of the 8 foot temperature tunnel's transpiration cooled nozzle was completed using an infrared imaging radiometer to locate regions of cooling flow irregularities caused by obstruction of three or more adjacent cooling slots. Restrictions in the cooling flow were found and cataloged. Blockages found were due primarily to the presence of residual phosphoric acid being discharged from some of the cooling slots. This acid was used during construction of the nozzle components and was to have been purged prior to its delivery to the NASA Langley Research Center (LaRC). In addition, a radial displacement of one selection of discs located in the spool piece was inspected and cataloged for future reference. There did not seem to be a serious restriction of flow in this defect, but evidence from the infrared images indicated reduced slot activity within the gouge. The radiometer survey uncovered regions where closer inspection is recommended but did not cover the entire surface area of the three nozzle subsections due to equipment limitations. A list of areas with suspected problems is included in Appendix A.

Borg, Stephen E.↗

Fabry-Perot-interferometer imaging system for thermospheric temperature and wind measurements

Doppler-broadened Fabry-Perot fringes of weak (less than 1-kR) auroral forbidden O I 5577- and 6300-A emissions have been detected in real time (1/60 sec) with the aid of a low-light level image-orthicon TV camera coupled to a two-stage image intensifier. The imaging scheme permits static-mode operation of a Fabry-Perot interferometer. For maximum use of all the information contained in every TV frame, each circular fringe may be sectioned into several annuli, and the corresponding annuli from all rings are summed to yield an intensity value. This procedure for deriving a fringe profile requires a video digitizer coupled to a digital processing system and should provide fast real-time (1/60 sec) measurements of E- and F-region temperatures and winds. With forbidden O I 5577-A intensity of 750 R, visually prominent TV images of the Fabry-Perot fringes were recorded in 0.5 sec, and the temperature of the emitting region was determined from two percent of the total information in the TV image.

Sivjee, G. G.↗

Large-area soft X-ray imaging system

System consists of large-area focusing collector and position sensitive proportional counter. Device can be used to study plasmas, with X-ray imaging in biological sciences, and crystallography.

Gorenstein, P.↗

Photosensor aperture shaping to reduce aliasing in optical-mechanical line-scan imaging systems.

Review of optical-mechanical scanning techniques that are generally employed in instruments specifically designed to characterize variations in scene brightness spectrally or radiometrically. Special attention is given to the effect of aliasing on the spatial detail of the reconstructed image. Aliasing may be caused by linescan sampling and can, in turn, severely degrade images that emphasize the spatial characterization of a scene. Photosensor aperture shaping and line-scan spacing are investigated as means for reducing this degradation.

Katzberg, S. J.↗