Search NASA⌕ Search

SEARCH · Search NASA

Results for “in situ instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Absolute mass calibration of fission product distributions measured with the E-$v$ method

The mass calibration of fission product distributions measured with the energy–velocity (E-v) method constitutes a technical challenge. The energy loss of the fission fragments in the various dead layers of the spectrometer and other sources of pulse-height defects of the energy detectors are a significant source of systematic uncertainty in the mass calculations used to determine the measured fission product yields. Here, in this study, the absolute calibration of the fission mass distributions is accomplished by measuring prompt γ-rays in coincidence with the fission fragments. This allows for the direct calibration of the mass spectra and eliminates any dependence on potentially complicated energy corrections. The first test measurement was performed at the Los Alamos Neutron Science Center employing the SPectrometer for Ion DEtermination in fission Research (SPIDER). SPIDER is a 2E-2v spectrometer designed for measuring independent fission product yields from neutron-induced fission. In this test, the single-arm SPIDER (E-v) system and an array of 252 Cf sources were used. The single-arm system consisted of two time pick-off detectors for measuring the time-of-flight of the fission fragments and a double-sided silicon strip detector (DSSD) for measuring the kinetic energy. Characteristic γ-rays from fission fragments were detected using three high-purity germanium (HPGe) detectors. For the mass calibration, γ–mass coincidence events from twelve product isotopes were used. The measured FPYs from 252 Cf spontaneous fission were found to be in excellent agreement with the evaluated data after applying the absolute mass calibration. From the γ–mass coincidence events, the mass resolution of the system was also extracted. An average mass resolution of ~1.4 AMU (FWHM) for the light fragments and ~2.4 AMU (FWHM) for the heavy fragments were found. This was the first in-situ calibration and characterization of the SPIDER spectrometer, which paves the way for high-quality FPY measurements with this instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In situ electron microscopy: atomic-scale dynamics of metal oxidation and corrosion

Corrosion degrades metals through complex microscopic processes that traditional methods often fail to capture. In-situ transmission electron microscopy (TEM) bridges this gap by providing real-time atomic-scale imaging of oxidation and corrosion dynamics. Gas-phase TEM uncovers critical oxidation mechanisms like oxide nucleation and alloying effects, while liquid-phase TEM tracks corrosion initiation. Coupled with emerging techniques like ultrafast direct electron detection cameras, these advancements promise unprecedented resolution in understanding material degradation.

36 MATERIALS SCIENCE↗

Phase Stability of Yttrium Titanium Oxide

This proposed study aims at elevating Idaho National Laboratory (INL)’s portfolio in nuclear material research on two major fronts: 1) expanding INL’s material characterization capabilities to provide holistic microstructural and microchemical characterization ranging from atomic scale to millimeter scale, and 2) filling the knowledge gap on the effect of microstructural evolution on material phase stability at extreme conditions resembling those inside nuclear reactors, using Yttrium-Titanium-Oxide (YTO) as a model material. Previous research indicated the kinetics of phase transition of YTO materials varies between bulk samples and powder samples, suggesting that microstructural characteristics such as defect, micro-strain, and crystallite size could play a significant role in phase transition. The effect of crystallite size on the thermodynamics of phase transition has been well documented for other ceramic materials at nanometer crystallite size, with potential impacts from surface and strain energy and defects. In this proposed study, we will perform microstructural (micro-strain, crystallite size, defects, phase) and microchemical (elemental mapping) analyses through in-situ high temperature measurements using X-ray diffraction (XRD; at millimeter scale for powder and bulk samples) and transmission electron microscopy (TEM, at nanometer scale and atomic scale for powder and thin foil samples), to provide a comprehensive view of the effect of microstructural and microchemical evolution on phase transition and phase stability of YTO materials. These findings will also establish a roadmap and provide new insights on the phase stability of other materials that are critical to nuclear energy and other renewable energy infrastructure. Besides advancing our understanding of this fundamental material science question, this project will also enable the development of state-of-the-art material characterization capabilities at INL/MFC for microstructural and microchemical analysis at high temperature conditions. The new collaboration between the High-Resolution Materials Characterization group at INL and the Electron Microscopy group at the University of Florida (UF) in this project will open the possibilities for more fruitful and synergetic cutting-edge nuclear material research in the future.

36 MATERIALS SCIENCE↗

Evaluation of ARM tethered-balloon system instrumentation for supercooled liquid water and distributed temperature sensing in mixed-phase Arctic clouds

A tethered-balloon system (TBS) has been developed and is being operated by Sandia National Laboratories (SNL) on behalf of the U.S. Department of Energy's (DOE) Atmospheric Radiation Measurement (ARM) User Facility in order to collect in situ atmospheric measurements within mixed-phase Arctic clouds. Periodic tethered-balloon flights have been conducted since 2015 within restricted airspace at ARM's Advanced Mobile Facility 3 (AMF3) in Oliktok Point, Alaska, as part of the AALCO (Aerial Assessment of Liquid in Clouds at Oliktok), ERASMUS (Evaluation of Routine Atmospheric Sounding Measurements using Unmanned Systems), and POPEYE (Profiling at Oliktok Point to Enhance YOPP Experiments) field campaigns. The tethered-balloon system uses helium-filled 34 m 3 helikites and 79 and 104 m 3 aerostats to suspend instrumentation that is used to measure aerosol particle size distributions, temperature, horizontal wind, pressure, relative humidity, turbulence, and cloud particle properties and to calibrate ground-based remote sensing instruments. Supercooled liquid water content (SLWC) sondes using the vibrating-wire principle, developed by Anasphere Inc., were operated at Oliktok Point at multiple altitudes on the TBS within mixed-hase clouds for over 200 h. Sonde-collected SLWC data were compared with liquid water content derived from a microwave radiometer, Ka-band ARM zenith radar, and ceilometer at the AMF3, as well as liquid water content derived from AMF3 radiosonde flights. The in situ data collected by the Anasphere sensors were also compared with data collected simultaneously by an alternative SLWC sensor developed at the University of Reading, UK; both vibrating-wire instruments were typically observed to shed their ice quickly upon exiting the cloud or reaching maximum ice loading. Temperature sensing measurements distributed with fiber optic tethered balloons were also compared with AMF3 radiosonde temperature measurements. Combined, the results indicate that TBS-distributed temperature sensing and supercooled liquid water measurements are in reasonably good agreement with remote sensing and radiosonde-based measurements of both properties. From these measurements and sensor evaluations, tethered-balloon flights are shown to offer an effective method of collecting data to inform and constrain numerical models, calibrate and validate remote sensing instruments, and characterize the flight environment of unmanned aircraft, circumventing the difficulties of in-cloud unmanned aircraft flights such as limited flight time and in-flight icing.

47 OTHER INSTRUMENTATION↗

Integrated fluorescence light microscopy-guided cryo-focused ion beam-milling for in situ montage cryo-ET

Cryogenic-electron tomography (cryo-ET) permits the in situ visualization of biological macromolecules at the molecular level. Owing to the variable thickness of cells, tissues and organisms, frozen specimens may need to be thinned by cryo-focused ion beam (FIB) milling to produce thin (<500 nm) cryo-lamellae suitable for cryo-ET. Locating regions of interest remains a challenge because untargeted milling can lead to inadvertent ablation and removal of regions of interest. Correlative light and electron microscopy, combined with cryo-FIB milling, can guide the identification of labeled targets in the cellular milieu. Multiple transfers between cryo-imaging instruments, cumbersome correlation algorithms, limited accuracy and low throughput have hindered the routine adoption of cryo-FIB milling within a multimodal correlative workflow for in situ structural biology. Here, in this study, we present a workflow for 3D correlative cryo-fluorescence light microscopy-FIB-ET that streamlines fluorescence light microscopy-guided FIB milling, improving throughput while preserving both structural and contextual information. The complete integration of hardware and software described here minimizes sample contamination from cross-platform exchanges and greatly enhances the efficiency of 3D targeting in cryo-milling. We then describe procedures for implementing montage parallel array cryo-ET (MPACT), which can be easily adapted to any modern life-science transmission electron microscope. MPACT supports high-throughput cryo-ET acquisitions (10 tilt series in 1.5 h) for structure determination and comprehensive contextual understanding of macromolecules within their native surroundings. A complete session from sample preparation to MPACT data processing takes 5−7 d for an individual experienced in both cryo-EM and cryo-FIB milling.

Yang, Jie E. [Univ. of Wisconsin, Madison, WI (Uni↗

An in-situ conductometric apparatus for physicochemical characterization of solutions and in-line monitoring of separation processes at elevated temperatures and pressures

Specific conductance and frequency-dependent resistance (impedance) data are widely utilized for understanding the physicochemical characteristics of aqueous and non-aqueous fluids and for evaluating the performance of chemical processes. However, the implementation of such an in-situ probe in high-temperature and high-pressure environments is not trivial. This work provides a description of both the hardware and software associated with implementing a parallel-type in-situ electrochemical sensor. The sensor can be used for in-line monitoring of thermal desalination processes and for impedance measurements in fluids at high temperature and pressure. Further, a comparison between the experimental measurements on the specific conductance in aqueous sodium chloride solutions and the conductance model demonstrate that the methodology yields reasonable agreement with both the model and literature data. A combination of hardware components, a software-based correction for experimental artifacts, and computational fluid dynamics (CFD) calculations used in this work provide a sound basis for implementing such in-situ electrochemical sensors to measure frequency-dependent resistance spectra.

47 OTHER INSTRUMENTATION↗

High-throughput mass spectrometry analysis using immediate drop-on-demand technology coupled with an open port sampling interface

Rationale: The sampling throughput of immediate drop-on-demand technology (I.DOT) coupled with an open port sampling interface (OPSI) is limited by software communication. To enable much-needed high-throughput mass spectrometry (MS) analysis capabilities, a novel software was developed that allows for flexible sample selection from a 96-well plate and for maximized analysis throughput using I.DOT/OPSI-MS coupling. Methods: Wells of a 96-well I.DOT plate were filled with propranolol solution and were used to test maximum sampling throughput strategies to minimize analysis time. Demonstration of chemical reaction monitoring was done using acid-catalyzed ring closure of 2,3-diaminonaphthalene (DAN) with nitrite to form 2,3-naphthotriazole (NAT). Analytes were detected in positive electrospray ionization mode using selected reaction monitoring. Results: A maximum throughput of 1.54 s/sample (7.41 min/96-well plate with three technical replicates) was achieved, and it was limited by the peak width of the MS signal resulting in an occasional slight overlap between the peaks. Further, relative standard deviation was 10 ± 1% with all tested sampling strategies. Chemical reaction monitoring of DAN to NAT using nitrite was successfully accomplished with 2 s/sample throughout showing almost complete transformation in 10 min with no signal overlap. Conclusions: This work illustrates the development of a noncontact, automated I.DOT/OPSI-MS system with improved throughput achieved through an optimized software interface. Its achievable analysis time and precision make it a viable approach for drug discovery and in situ reaction monitoring studies.

47 OTHER INSTRUMENTATION↗

ExoMars Mars Organic Molecule Analyzer (MOMA) Laser Desorption/Ionization Mass Spectrometry (LDI-MS) Analysis of Phototrophic Communities from a Silica-Depositing Hot Spring in Yellowstone National Park, USA

The Mars Organic Molecule Analyzer (MOMA) is a key scientific instrument on the ExoMars Rover mission. MOMA is designed to detect and characterize organic compounds, over a wide range of volatility and molecular weight, in samples obtained from up to two meters below the martian surface. Thorough analog sample studies are required to best prepare to interpret MOMA data collected on Mars. We present here the MOMA characterization of Mars analog samples collected from an alkaline silica depositing hot spring in Yellowstone National Park, WY, USA. These samples contain microbial streamer communities composed primarily of oxygenic and anoxygenic phototrophs. Additionally, in a study focused on detection of key classes of nonvolatile organics, samples of microbial streamers and their total lipid extract (TLE) have been measured on a MOMA Engineering Test Unit (ETU) instrument using its laser desorption/ionization mass spectrometry (LDI-MS) mode. MOMA LDI-MS detected a variety of lipids and pigments in the TLE sample. Species such as chlorophyll a were also detected from the streamer sample with the help of mass isolation. The results add to the LDI-MS sample characterization database, as well as demonstrate the benefit of using mass isolation on the MOMA instrument to reveal the presence of complex organics, and potential biomarkers, preserved in a natural sample, providing guidance to the in situ analysis of surface samples during Mars operations.

59 BASIC BIOLOGICAL SCIENCES↗

Calibration of the liquid argon ionization response to low energy electronic and nuclear recoils with DarkSide-50

DarkSide-50 has demonstrated the high potential of dual-phase liquid argon time projection chambers in exploring interactions of WIMPs in the GeV=c 2 mass range. The technique, based on the detection of the ionization signal amplified via electroluminescence in the gas phase, allows us to explore recoil energies down to the sub-keV range. We report here on the DarkSide-50 measurement of the ionization yield of electronic recoils down to ~180 eV er , exploiting 37 Ar and 39 Ar decays, and extrapolated to a few ionization electrons with the Thomas-Imel box model. Further, we present a model-dependent determination of the ionization response to nuclear recoils down to ~500 eV nr , the lowest ever achieved in liquid argon, using in situ neutron calibration sources and external datasets from neutron beam experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Integrated atomic force microscopy and x-ray irradiation for in situ characterization of radiation-induced processes

Understanding radiation-induced chemical and physical transformations at material interfaces is important across diverse fields, but experimental approaches are often limited to either ex situ observations or in situ electron microscopy or synchrotron-based methods in which cases the radiation type and dose are inextricably tied to the imaging basis itself. In this work we overcome this limitation by demonstrating integration of an X-ray source with an atomic force microscope to directly monitor radiolytically-driven interfacial chemistry at the nanoscale. We illustrate the value of in situ observations by examining effects of radiolysis on material adhesion forces in aqueous solution, as well as examining the production of alkali nitrates at the interface between an alkali halide crystal surface and air. For the examined salt-air interface, direct visualization under flexible experimental conditions greatly extends prior observations by enabling the transformation process to be followed comprehensively from source-to-sink with mass balance quantitation. Overall, our novel rad-AFM opens doors into understanding the dynamics of radiolytically-driven mass transfer and surface alteration at the nanoscale in real-time.

47 OTHER INSTRUMENTATION↗

In-Situ Measurement of Power Loss for Crystalline Silicon Modules Undergoing Thermal Cycling and Mechanical Loading Stress Testing

An in-situ method is proposed for monitoring and estimating the power degradation of mc-Si photovoltaic (PV) modules undergoing thermo-mechanical degradation tests that primarily manifest through cell cracking, such as mechanical load tests, thermal cycling and humidity freeze tests. The method is based on in-situ measurement of the module’s dark current-voltage (I-V) characteristic curve during the stress test, as well as initial and final module flash testing on a Sun simulator. The method uses superposition of the dark I-V curve with final flash test module short-circuit current to account for shunt and junction recombination losses, as well as series resistance estimation from the in-situ measured dark I-Vs and final flash test measurements. The method is developed based on mc-Si standard modules undergoing several stages of thermo-mechanical stress testing and degradation, for which we investigate the impact of the degradation on the modules light I-V curve parameters, and equivalent solar cell model parameters. Experimental validation of the method on the modules tested shows good agreement between the in-situ estimated power degradation and the flash test measured power loss of the modules, of up to 4.31 % error (RMSE), as the modules experience primarily junction defect recombination and increased series resistance losses. However, the application of the method will be limited for modules experiencing extensive photo-current degradation or delamination, which are not well reflected in the dark I-V characteristic of the PV module.

14 SOLAR ENERGY↗

Accelerated and heterogeneous corrosion of Cr-doped uranium nitride fuel pellets

The steam oxidation of Cr-doped UN fuel pellets is analyzed during sequential isothermal holds up to 720 °C. In situ neutron diffraction results show how Cr is accommodated in a secondary U 2 CrN 3 phase, leading to the formation of a duplex UN/U 2 CrN 3 microstructure. Under corrosion, the oxidation of the two phases begins at 400 °C for UN and 430 °C for U 2 CrN 3 , respectively. Because the UN phase is preferentially oxidized in the presence of U 2 CrN 3 , addition of Cr in UN based nuclear fuel is found to accelerate the corrosion rate. At 430 °C the oxidation of UN in the UN/U 2 CrN 3 microstructure is ~ 5 times faster than pure UN, increasing to ~19 times faster at 460 °C. The oxidation of U 2 CrN 3 produces UO 2 via the formation of two transient intermediate phases. In situ neutron diffraction enables oxidation processes of UN and U 2 CrN 3 components to be followed separately within the two-phase system.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Scalable DAQ system operating the CHIPS-5 neutrino detector

The CHIPS R&D project focuses on development of low-cost water Cherenkov neutrino detectors through novel design strategies and resourceful engineering. This work presents an end-to-end DAQ solution intended for a recent 5 kt CHIPS prototype, which is largely based on affordable mass-produced components. Much like the detector itself, the presented instrumentation is composed of modular arrays that can be scaled up and easily serviced. A single such array can carry up to 30 photomultiplier tubes (PMTs) accompanied by electronics that generate high voltage in-situ and deliver time resolution of up to 0.69 ns. In addition, the technology is compatible with the White Rabbit timing system, which can synchronize its elements to within 100 ps. While deployment issues did not permit the presented DAQ system to operate beyond initial evaluation, the presented hardware and software successfully passed numerous commissioning tests that demonstrated their viability for use in a large-scale neutrino detector, instrumented with thousands of PMTs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stream Chemistry, Synoptic Surveys, East Fork Poplar Creek Watershed, TN, USA; April 2023 to February 2025

Impacts of developed land cover on stream chemistry can be difficult to discern from natural variability, particularly in carbonate watersheds where weathering of urban infrastructure and lithology generate similar signatures. We evaluated how spatial patterns of stream chemistry varied across perennial and non-perennial tributaries spanning an urban-to-forested gradient in a mid-order, carbonate-dominated watershed. This data package contains a processed and compiled summary of stream chemistry and properties obtained from 12 synoptic surveys of 54 stream sites across the East Fork Poplar Creek watershed located near Oak Ridge, TN, United States. The sites include non-perennial tributaries, perennial tributaries, and the main stem and span forested to urban (highly developed) land cover gradients. The data package includes the processed and flagged chemical data (WaDE_SynopticSummary_FinalChemistry), metadata describing data flagging and analysis (WaDE_SynopticSummary_Metadata), information about each site and its contributing subcatchment (WaDE_SynopticSummary_SiteInformation), and a comparison of instrument and field detection limits used to determine method detection limits for the study (WaDE_SynopticSummary_DetectionLimitComparison). Stream chemistry includes stream parameters measured in situ using multiparameter probes (dissolved oxygen, pH, specific conductance, temperature) and solutes including nutrients (nitrate, ammonium, soluble reactive phosphorus), dissolved organic carbon, dissolved inorganic carbon, major cations (calcium, magnesium, potassium, sodium), major anions (chloride, sulfate), and a broad suite of minor and trace elements.

EARTH SCIENCE > TERRESTRIAL HYDROSPHERE > SURFACE ↗

In Situ Soil Moisture and Thaw Depth Measurements Coincident with Airborne SAR Data Collections, Seward Peninsula, Alaska, 2019

The in-situ soil moisture and thaw depth measurements provided in this dataset were collected coincident with airborne overflights of L- and P-band SAR instruments at the Teller and Kougarok NGEE Arctic study sites on the Seward Peninsula, Alaska. Field measurements and flights were conducted in August 2019 as a collaboration between the NASA ABoVE Project's Airborne SAR Campaign and the NGEE Arctic Project. ABoVE protocols for establishing field measurement plots were followed. NGEE Arctic plots for the ground-based measurements are located at existing study sites where SAR data would also add value to current monitoring and characterization efforts of the NGEE Team. The ground-based data will be used by ABoVE to analyze, calibrate and validate the remote sensing products. This dataset follows the format and collection guidelines of the collaboration effort in 2017. Contained in this dataset are *.csv (including data dictionaries), .zip, .kml, .jpgs, .py, and .pdf files.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort (with some overlap with Covid-19 pandemic) to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Design of RUSL Irradiation Experiment with Free Standing Sample

During FY19, the MIMIC-RUSL TREAT test successfully measured the shift in resonance of a cantilever beam as it underwent a grain restructuring event in the TREAT reactor core. FY20 efforts focused on a new capsule design which would replace the cantilever beam with a free-free beam. The free-free beam configuration eliminates the cantilever boundary condition and enables internal friction measurements. A test capsule was designed which supported the sample beam at the nodal points of the first flexural vibration mode. Initial tests detected the resonance peak but the signal to noise level was not high enough for in-situ measurements. Several detection probes were tested and a significant increase in the signal to noise was achieved. Although adequate signals and clean resonance peaks were measured when the beam was centered, the beam did not self-center when displaced resulting in distorted and inconsistent resonance peaks. It was concluded that the free-free beam approach is likely not suited for in-situ measurements. Measurement of ZGV plate waves is another option for in-situ microstructure monitoring and should be considered for future work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗