Search NASA⌕ Search

SEARCH · Search NASA

Results for “injection test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Applying colloidal silica suspensions injection and sequential gelation to block vertical water flow in well annulus: laboratory testing on rheology, gelation, and injection

We evaluated the application of silica suspension injection and sequential gelation to block vertical water flow in the annuli of long-screened wells. First, we studied the viscosity, rheological behavior, and gelation performance of colloidal silica suspensions in batch tests. Then, we tested the injection of silica suspensions and the water flow blocking efficiency of the later formed silica gel in column and bench-scale sandbox experiments. Micron-sized fumed powder silica suspensions and nanosized silica suspensions recovered from geothermal fluids were tested in this work. Fumed silica suspensions showed shear thinning, while nanosized silica suspensions exhibited Newtonian flow behavior. During the gelation process, the nanosized silica suspension changed from a Newtonian fluid to a shear thinning fluid while increasing its overall viscosity. At comparable concentrations, the nanosized silica suspensions have much lower viscosity than that of the fumed silica suspensions. Increases in the Na + concentration and silica particle concentration in these suspensions shortened the gelation time. Silica suspension gelation in sand columns completely blocked the water flow and sustained the injection pressure up to 50 psig (344.7 kPa). A silica suspension was successfully injected into the target zone in the annulus of a bench-scale sandbox mimicking long-screened wells in the field. The silica gel formed in the annulus effectively blocked chemical transport through the gelled zone. Our research reveals that a process using silica suspension injection and sequential gelation technology is promising for blocking the vertical water flow and chemical transport through the filter pack in targeted zones within the annulus of long-screened well systems.

54 ENVIRONMENTAL SCIENCES↗

Development of ion injection into the BNL test electron beam ion source using a prototype low energy beam transfer switchyard and a hollow cathode ion source (abstract)

In order to provide a variety of ion species to the BNL relativistic heavy ion collider (RHIC) and NASA Space Radiation Laboratory facilities on a pulse-to-pulse basis, the BNL RHIC electron beam ion source (EBIS) will use injection of primary ''seed'' ions from external low charged ion sources. As part of the prototype for the RHIC EBIS low energy beam transport line, a switchyard for seed ion injection and extracted EBIS ion beams has been constructed. The ion injection line includes a hollow cathode ion source (HCIS), four quadrupole lenses, a switchyard, gridded lenses, and other deflection optics. The HCIS is based on one obtained from CEA Saclay [B. Visentin et al., Phys. Scr., T 71, 204 (1997).] and has been used in bench studies in the production of low charged metal and gas ions, as well as in BNL test EBIS injection studies for the production of highly charged ions. The HCIS geometry and extraction optics have been modified to be able to reach the output currents necessary to seed the test EBIS. Ion currents greater than 60 {mu}A Cu{sup +} and 130 {mu}A Ne{sup +} have been extracted from the modified HCIS at 12-15 kV and plasma aperture of 1-1.5 mm. The HCIS discharge is initiated by a rf coil and can be operated stably at pulse rates from 1 to 100 Hz. Measurement of the emittance of injector beam before and after the injection switchyard will be provided, as well as results from ion injection into the test EBIS using the new injector configuration.

43 PARTICLE ACCELERATORS↗

Design and Testing of Trace Contaminant Injection and Monitoring Systems

In support of the Carbon dioxide And Moisture Removal Amine Swing-bed (CAMRAS) testing, a contaminant injection system as well as a contaminant monitoring system has been developed by the Johnson Space Center Air Revitalization Systems (JSC-ARS) team. The contaminant injection system has been designed to provide trace level concentrations of contaminants generated by humans in a closed environment during space flight missions. The contaminant injection system continuously injects contaminants from three gas cylinders, two liquid reservoirs and three permeation ovens. The contaminant monitoring system has been designed to provide real time gas analysis with accurate flow, humidity and gas concentration measurements for collection during test. The contaminant monitoring system consists of an analytical real time gas analyzer, a carbon monoxide sensor, and an analyzer for ammonia and water vapor.

Broerman, Craig D.↗

Hanford 100-D Area Biostimulation Soluble Substrate Field Test: Interim Data Summary for the Substrate Injection and Process Monitoring Phases of the Field Test

Pacific Northwest National Laboratory is conducting a treatability test designed to demonstrate that in situ biostimulation can be applied to help meet cleanup goals in the Hanford Site 100-D Area. The in situ biostimulation technology is intended to provide supplemental treatment upgradient of the In Situ Redox Manipulation (ISRM) barrier by reducing the concentration of the primary oxidizing species in groundwater (i.e., nitrate and dissolved oxygen) and chromate, and thereby increasing the longevity of the ISRM barrier. This report summarizes the initial results from field testing of an in situ biological treatment zone implemented through injection of a soluble substrate. The field test is divided into operational phases that include substrate injection, process monitoring, and performance monitoring. The results summarized herein are for the substrate injection and process monitoring phase encompassing the first approximately three months of field testing. Performance monitoring is ongoing at the time this report was prepared and is planned to extend over approximately 18 months. As such, this report is an interim data summary report for the field test. The treatability testing has multiple objectives focused on evaluating the performance of biostimulation as a reducing barrier for nitrate, oxygen, and chromate. The following conclusions related to these objectives are supported by the data provided in this report. Substrate was successfully distributed to a radius of about 15 m (50 ft) from the injection well. Monitoring data indicate that microbial growth initiated rapidly, and this rapid growth would limit the ability to inject substrate to significantly larger zones from a single injection well. As would be expected, the uniformity of substrate distribution was impacted by subsurface heterogeneity. However, subsequent microbial activity and ability to reduce the targeted species was observed throughout the monitored zone during the process monitoring period, and low nitrate and oxygen concentrations were maintained. Chromate concentrations in the treatment zone began to increase about two months after substrate injection, up to about 30 percent of the background concentration upgradient of the test site. The performance monitoring phase will provide additional data to interpret the performance of the biostimulation process and information for scale-up as a reducing barrier.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Single-well experimental design for studying residual trapping of superciritcal carbon dioxide

The objective of our research is to design a single-well injection-withdrawal test to evaluate residual phase trapping at potential CO{sub 2} geological storage sites. Given the significant depths targeted for CO{sub 2} storage and the resulting high costs associated with drilling to those depths, it is attractive to develop a single-well test that can provide data to assess reservoir properties and reduce uncertainties in the appraisal phase of site investigation. The main challenges in a single-well test design include (1) difficulty in quantifying the amount of CO{sub 2} that has dissolved into brine or migrated away from the borehole; (2) non-uniqueness and uncertainty in the estimate of the residual gas saturation (S{sub gr}) due to correlations among various parameters; and (3) the potential biased S{sub gr} estimate due to unaccounted heterogeneity of the geological medium. To address each of these challenges, we propose (1) to use a physical-based model to simulation test sequence and inverse modeling to analyze data information content and to quantify uncertainty; (2) to jointly use multiple data types generated from different kinds of tests to constrain the Sgr estimate; and (3) to reduce the sensitivity of the designed tests to geological heterogeneity by conducting the same test sequence in both a water-saturated system and a system with residual gas saturation. To perform the design calculation, we build a synthetic model and conduct a formal analysis for sensitivity and uncertain quantification. Both parametric uncertainty and geological uncertainty are considered in the analysis. Results show (1) uncertainty in the estimation of Sgr can be reduced by jointly using multiple data types and repeated tests; and (2) geological uncertainty is essential and needs to be accounted for in the estimation of S{sub gr} and its uncertainty. The proposed methodology is applied to the design of a CO{sub 2} injection test at CO2CRC's Otway Project Site, Victoria, Australia.

54 ENVIRONMENTAL SCIENCES↗

On the Design and Test of a Liquid Injection Electric Thruster

A liquid injection electric thruster (LINJET) was designed and tested. The results of the tests were very encouraging with thruster performance levels well in excess of design goals. Supporting activities to the engine design and test included a five-million pulse life test on the main capacitor, a 46-million pulse test on the trigger electronics, design and fabrication of a zero resistance torque connector for use with the torsional pendulum thrust stand, design and fabrication of a logic box for control of engine firing, and a physical and chemical properties characterization of the perfluorocarbon propellant. While the results were encouraging, testing was limited, as many problems existed with the design. The most significant problem was involved with excessive propellant flow which contributed to false triggering and shorting. Low power active thermal control of the propellant storage cavity, coupled with a re-evaluation of the injection ring pore size and area exposed to the main capacitor discharge are areas that should be investigated should this design be carried forward.

Jones, T. A.↗

Review of Design Elements within Power Infrastructure Cyber–Physical Test Beds as Threat Analysis Environments

Cyber–physical systems (CPSs) are an integral part of modern society; thus, enhancing these systems’ reliability and resilience is paramount. Cyber–physical testbeds (CPTs) are a safe way to test and explore the interplay between the cyber and physical domains and to cost-effectively enhance the reliability and resilience of CPSs. Here a review of CPT elements, broken down into physical components (simulators, emulators, and physical hardware), soft components (communication protocols, network timing protocols), and user interfaces (visualization-dashboard design considerations) is presented. Various methods used to validate CPS performance are reviewed and evaluated for potential applications in CPT performance validation. Last, initial simulated results for a CPT design, based on the IEEE 33 bus system, are presented, along with a brief discussion on how model-based testing and fault–injection-based testing (using scaling and ramp-type attacks) may be used to help validate CPT performance.

14 SOLAR ENERGY↗

Radio observations of GRB 100418a: Test of an energy injection model explaining long-lasting GRB afterglows

We present the results of our radio observational campaign of gamma-ray burst (GRB) 100418a, for which we used the Australia Telescope Compact Array, the Very Large Array, and the Very Long Baseline Array. GRB 100418a was a peculiar GRB with unusual X-ray and optical afterglow profiles featuring a plateau phase with a very shallow rise. This observed plateau phase was believed to be due to a continued energy injection mechanism that powered the forward shock, giving rise to an unusual and long-lasting afterglow. The radio afterglow of GRB 100418a was detectable several weeks after the prompt emission. We conducted long-term monitoring observations of the afterglow and attempted to test the energy injection model advocating that the continuous energy injection is due to shells of material moving at a wide range of Lorentz factors. We obtained an upper limit of γ < 7 for the expansion rate of the GRB 100418a radio afterglow, indicating that the range-of-Lorentz factor model could only be applicable for relatively slow-moving ejecta. A preferred explanation could be that continued activity of the central engine may have powered the long-lasting afterglow.

79 ASTRONOMY AND ASTROPHYSICS↗

Effect of Viscosity on Fuel Leakage Between Lapped Plungers and Sleeves and on the Discharge from a Pump-Injection System

Test data and analysis show that the rate of fuel leakage between a lapped plunger and sleeve varies directly with the density of the fuel, the diameter of the plunger, the pressure producing the leakage, and the cube of the mean clearance between the plunger and sleeve. The rate varies inversely as the length of the lapped fit and the viscosity of the fuel. With a mean clearance between the plunger and sleeve of 0.0001 inch the leakage amounts to approximately 0.2 percent of the fuel injected with gasoline and as low as 0.01 percent with diesel fuel oils. With this mean clearance an effective seal is obtained when the length of the lap is three times the diameter of the lap. The deformation of the sleeve and plunger under pressure is sufficient to change the rate of leakage appreciably from that which would be obtained if the clearance was constant under pressure.

Rothrock, A M↗

Field Testing of Activated Carbon Injection Options for Mercury Control at TXU's Big Brown Station

The primary objective of the project was to evaluate the long-term feasibility of using activated carbon injection (ACI) options to effectively reduce mercury emissions from Texas electric generation plants in which a blend of lignite and subbituminous coal is fired. Field testing of ACI options was performed on one-quarter of Unit 2 at TXU's Big Brown Steam Electric Station. Unit 2 has a design output of 600 MW and burns a blend of 70% Texas Gulf Coast lignite and 30% subbituminous Powder River Basin coal. Big Brown employs a COHPAC configuration, i.e., high air-to-cloth baghouses following cold-side electrostatic precipitators (ESPs), for particulate control. When sorbent injection is added between the ESP and the baghouse, the combined technology is referred to as TOXECON{trademark} and is patented by the Electric Power Research Institute in the United States. Key benefits of the TOXECON configuration include better mass transfer characteristics of a fabric filter compared to an ESP for mercury capture and contamination of only a small percentage of the fly ash with AC. The field testing consisted of a baseline sampling period, a parametric screening of three sorbent injection options, and a month long test with a single mercury control technology. During the baseline sampling, native mercury removal was observed to be less than 10%. Parametric testing was conducted for three sorbent injection options: injection of standard AC alone; injection of an EERC sorbent enhancement additive, SEA4, with ACI; and injection of an EERC enhanced AC. Injection rates were determined for all of the options to achieve the minimum target of 55% mercury removal as well as for higher removals approaching 90%. Some of the higher injection rates were not sustainable because of increased differential pressure across the test baghouse module. After completion of the parametric testing, a month long test was conducted using the enhanced AC at a nominal rate of 1.5 lb/Macf. During the time that enhanced AC was injected, the average mercury removal for the month long test was approximately 74% across the test baghouse module. ACI was interrupted frequently during the month long test because the test baghouse module was bypassed frequently to relieve differential pressure. The high air-to-cloth ratio of operations at this unit results in significant differential pressure, and thus there was little operating margin before encountering differential pressure limits, especially at high loads. This limited the use of sorbent injection as the added material contributes to the overall differential pressure. This finding limits sustainable injection of AC without appropriate modifications to the plant or its operations. Handling and storage issues were observed for the TOXECON ash-AC mixture. Malfunctioning equipment led to baghouse dust hopper plugging, and storage of the stagnant material at flue gas temperatures resulted in self-heating and ignition of the AC in the ash. In the hoppers that worked properly, no such problems were reported. Economics of mercury control at Big Brown were estimated for as-tested scenarios and scenarios incorporating changes to allow sustainable operation. This project was funded under the U.S. Department of Energy National Energy Technology Laboratory project entitled 'Large-Scale Mercury Control Technology Field Testing Program--Phase II'.

01 COAL, LIGNITE, AND PEAT↗

Silurian "Clinton" Sandstone Reservoir Characterization for Evaluation of CO 2 -EOR Potential in the East Canton Oil Field, Ohio

The purpose of this study was to evaluate the efficacy of using CO 2 -enhanced oil recovery (EOR) in the East Canton oil field (ECOF). Discovered in 1947, the ECOF in northeastern Ohio has produced approximately 95 million barrels (MMbbl) of oil from the Silurian “Clinton” sandstone. The original oil-in-place (OOIP) for this field was approximately 1.5 billion bbl and this study estimates by modeling known reservoir parameters, that between 76 and 279 MMbbl of additional oil could be produced through secondary recovery in this field, depending on the fluid and formation response to CO 2 injection. A CO 2 cyclic test (“Huff-n-Puff”) was conducted on a well in Stark County to test the injectivity in a “Clinton”-producing oil well in the ECOF and estimate the dispersion or potential breakthrough of the CO 2 to surrounding wells. Eighty-one tons of CO 2 (1.39 MMCF) were injected over a 20-hour period, after which the well was shut in for a 32-day “soak” period before production was resumed. Results demonstrated injection rates of 1.67 MMCF of gas per day, which was much higher than anticipated and no CO 2 was detected in gas samples taken from eight immediately offsetting observation wells. All data collected during this test was analyzed, interpreted, and incorporated into the reservoir characterization study and used to develop the geologic model.

02 PETROLEUM↗

Program for impact testing of spar-shell fan blades, test report

Six filament-wound, composite spar-shell fan blades were impact tested in a whirligig relative to foreign object damage resulting from ingestion of birds into the fan blades of a QCSEE-type engine. Four of the blades were tested by injecting a simulated two pound bird into the path of the rotating blade and two were tested by injecting a starling into the path of the blade.

Ravenhall, R.↗

Architecture, implementation, and testing of a multiple-shell gas injection system for high current implosions on the Z accelerator

Tests are ongoing to conduct {approx}20 MA z-pinch implosions on the Z accelerator at Sandia National Laboratory using Ar, Kr, and D{sub 2} gas puffs as the imploding loads. The relatively high cost of operations on a machine of this scale imposes stringent requirements on the functionality, reliability, and safety of gas puff hardware. Here we describe the development of a prototype gas puff system including the multiple-shell nozzles, electromagnetic drivers for each nozzle's valve, a UV pre-ionizer, and an inductive isolator to isolate the {approx}2.4 MV machine voltage pulse present at the gas load from the necessary electrical and fluid connections made to the puff system from outside the Z vacuum chamber. This paper shows how the assembly couples to the overall Z system and presents data taken to validate the functionality of the overall system.

42 ENGINEERING↗

Aboveground Injection System Mechanical Integrity Test Results Report

An In-Situ Bioremediation (ISB) Pilot Test Treatability Study is planned at Sandia National Laboratories, New Mexico (SNL/NM) Technical Area-V (TA-V) Groundwater Area of Concern. The Treatability Study is designed to gravity inject an electron-donor substrate and bioaugmentation bacteria into groundwater using an injection well. The constituents of concern (COCs) are nitrate and trichloroethene (TCE). The Pilot Test Treatability Study will evaluate the effectiveness of bioremediation and COC treatment over a prescribed period of time. Results of the pilot test will provide data that will be used to evaluate the cost and effectiveness of a full-scale system.

54 ENVIRONMENTAL SCIENCES↗

Flow Simulation of Solid Rocket Motors: Injection Induced Water-Flow Tests from Porous Media - 1

Prior to selecting a proper porous material for use in simulating the internal port flow of a solid rocket motor (SRM), in cold-flow testing, the flow emerging from porous materials is experimentally investigated. The injection-flow emerging from a porous matrix always exhibits a lumpy velocity profile that is spatially stable and affects the development of the longitudinal port flow. This flow instability, termed pseudoturbulence, is an inherent signature of the porous matrix and is found to generally increase with the wall porosity and with the injection flow rate. Visualization studies further show that the flow from porous walls made from shaving-type material (sintered stainless-steel) exhibits strong recirculation zones that are conspicuously absent in walls made from nodular or spherical material (sintered bronze). Detailed flow visualization observations and hot-film measurements are reported from tests of injection-flow and a coupled cross-flow from different porous wall materials. Based on the experimental data, discussion is provided on the choice of suitable material for SRM model testing while addressing the consequences and shortcomings from such a test.

Ramachandran, N.↗

Active Recycling Control Through Lithium Injection in EAST

The coating of tokamak walls with thin layers of lithium has been demonstrated to reduce plasma recycling from the plasma-facing surfaces and to improve overall plasma performance. These effects, including reduced divertor D α emission, the elimination of edge-localized modes, and increased energy confinement have been observed in multiple experiments when lithium coatings are applied before plasma discharges. However, this coating technology does not extrapolate to future long-pulse devices, since the lithium coatings will be passivated by the continual plasma flux onto the surface. In order to provide active conditioning capability, a new technology has been developed that is capable of injecting lithium powder into the scrape-off layer plasma during plasma discharges, where it quickly liquefies and turns into an aerosol. The use of this “lithium dropper” is under study at the Experimental Advanced Superconducting Tokamak (EAST), where the potential benefits of real-time wall conditioning via lithium injection are being tested. Here, we present an analysis of the recycling characteristics during EAST experiments testing active lithium injection in order to assess recycling reduction and control. Lithium aerosol was injected from the top of the machine, with one system dropping lithium near the X-point and another into the low-field side divertor leg. The injection of lithium into the SOL reduced divertor recycling, as evidenced by reduced D α emission with ion flux measured by probes relatively unchanged. This effect is strongest in the active divertor, confirming the lithium is transported to strongly plasma-wetted areas. Furthermore, quantitative analysis of the recycling changes using the SOLPS edge plasma and neutral transport code indicated a ~20% reduction in recycling coefficient with lithium injection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mars Ascent Vehicle Hybrid Propulsion Development

Mars Ascent Vehicle Study Agenda: Potential Mars Sample Return (MSR); Potential Hybrid Design; 2019 Preliminary Architecture Assessment; Propellant Combination - Fuel; Propellant Combination - Oxidizer; Full Scale Testing thru 2018; Hypergolic Ignition; TEA/TEB (triethylaluminum/triethylborane) Ignition; Solid Hypergolic Additives; 2018 test - longest duration test; 2019 test; Liquid Injection Thrust Vector Control; White Sands Test Facility; FY19 and Future Work; Summary.

Story, George↗