Search NASA⌕ Search

SEARCH · Search NASA

Results for “intact samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Estimation of coarse dead wood stocks in intact and degraded forests in the Brazilian Amazon using airborne lidar

Coarse dead wood is an important component of forest carbon stocks, but it is rarely measured in Amazon forests and is typically excluded from regional forest carbon budgets. Our study is based on line intercept sampling for fallen coarse dead wood conducted along 103 transects with a total length of 48 km matched with forest inventory plots where standing coarse dead wood was measured in the footprints of larger areas of airborne lidar acquisitions. We developed models to relate lidar metrics and Landsat time series variables to coarse dead wood stocks for intact, logged, burned, or logged and burned forests. Canopy characteristics such as gap area produced significant individual relations for logged forests. For total fallen plus standing coarse dead wood (hereafter defined as total coarse dead wood), the relative root mean square error for models with only lidar metrics ranged from 33 % in logged forest to up to 36 % in burned forests. The addition of historical information improved model performance slightly for intact forests (31 % against 35 % relative root mean square error), not justifying the use of a number of disturbance events from historical satellite images (Landsat) with airborne lidar data. Lidar-derived estimates of total coarse dead wood compared favorably with independent ground-based sampling for areas up to several hundred hectares. The relations found between total coarse dead wood and variables quantifying forest structure derived from airborne lidar highlight the opportunity to quantify this important but rarely measured component of forest carbon over large areas in tropical forests.

Brazilian Amazon↗

Thermal Pretreatment of Wood for Co-gasification/co-firing of Biomass and Coal

Utilization of biomass as a co-feed in coal and biomass co-firing and co-gasification requires size reduction of the biomass. Reducing biomass to below 0.2 mm without pretreatment is difficult and costly because biomass is fibrous and compressible. Torrefaction is a promising thermal pretreatment process and has the advantages of increasing energy density, improving grindability, producing fuels with more homogenous compositions and hydrophobic behavior. Temperature is the most important factor for the torrefaction process. Biomass grindability is related to cell wall structure, thickness and composition. Thermal treatment such as torrefaction can cause chemical changes that significantly affect the strength of biomass. The objectives of this study are to understand the mechanism by which torrefaction improves the grindability of biomass and discuss suitable temperatures for thermal pretreatment for co-gasification/co-firing of biomass and coal. Wild cherry wood was selected as the model for this study. Samples were prepared by sawing a single tangential section from the heartwood and cutting it into eleven pieces. The samples were consecutively heated at 220, 260, 300, 350, 450 and 550⁰C for 0.5 hr under flowing nitrogen in a tube furnace. Untreated and treated samples were characterized for physical properties (color, dimensions and weight), microstructural changes by SEM, and cell wall composition changes and thermal behaviors by TGA and DSC. The morphology of the wood remained intact through the treatment range but the cell walls were thinner. Thermal treatments were observed to decompose the cell wall components. Hemicellulose decomposed over the range of ~200 to 300⁰C and resulted in weakening of the cell walls and subsequently improved grindability. Furthermore, wood samples treated above 300⁰C lost more than 39% in mass. Therefore, thermal pretreatment above the hemicelluloses decomposition temperature but below 300⁰C is probably sufficient to improve grindability and retain energy value.

09 BIOMASS FUELS↗

STXM-XANES analyses of Murchison meteorite samples captured by aerogel after hypervelocity impacts: A potential implication of organic matter degradation for micrometeoroid collection experiments

The Tanpopo mission is an astrobiology space experiment at the Japanese Experiment Module (JEM) 'Kibo' on the International Space Station (ISS). One of the sub-divided themes of the Tanpopo mission is for the intact capture of organic bearing micrometeoroids in low Earth orbit using ultralow density silica aerogel (0.01 g/cm 3 ). In order to evaluate damage to organic matter in micrometeoroids during hyper velocity impacts into the aerogel, Murchison meteorite powdered samples, analogs of organic bearing micrometeoroids, were fired into flight-grade silica aerogel (0.01 g/cm 3 ) using a two-stage light-gas gun with velocities of 4.4 and 5.9 km/s. The recovered Murchison grains were analyzed using scanning transmission X-ray microscopy/X-ray absorption near edge structure (STXM/XANES), transmission electron microscopy (TEM) and nanoscale secondary ion mass spectrometry (NanoSIMS). TEM observation did not show significant modifications of the recovered Murchison grains. Carbon-XANES spectra, however, showed a large depletion of the organic matter after the 5.9 km/s impact, but no such effects nor any significant hydrogen isotopic fractionation were observed after the 4.4 km/s impact.

58 GEOSCIENCES↗

Site-Specific Preparation of Intact Solid–Liquid Interfaces by Label-Free In Situ Localization and Cryo-Focused Ion Beam Lift-Out

Abstract Scanning transmission electron microscopy (STEM) allows atomic scale characterization of solid–solid interfaces, but has seen limited applications to solid–liquid interfaces due to the volatility of liquids in the microscope vacuum. Although cryo-electron microscopy is routinely used to characterize hydrated samples stabilized by rapid freezing, sample thinning is required to access the internal interfaces of thicker specimens. Here, we adapt cryo-focused ion beam (FIB) “lift-out,” a technique recently developed for biological specimens, to prepare intact internal solid–liquid interfaces for high-resolution structural and chemical analysis by cryo-STEM. To guide the milling process we introduce a label-free in situ method of localizing subsurface structures in suitable materials by energy dispersive X-ray spectroscopy (EDX). Monte Carlo simulations are performed to evaluate the depth-probing capability of the technique, and show good qualitative agreement with experiment. We also detail procedures to produce homogeneously thin lamellae, which enable nanoscale structural, elemental, and chemical analysis of intact solid–liquid interfaces by analytical cryo-STEM. This work demonstrates the potential of cryo-FIB lift-out and cryo-STEM for understanding physical and chemical processes at solid–liquid interfaces.

36 MATERIALS SCIENCE↗

The impact of aqueous medium on zeolite framework integrity

Understanding the zeolite framework stability in aqueous phase is crucial to develop stable catalysts. Al K–edge, extended X–ray absorption fine structure and 27Al MAS NMR spectroscopies in combination with DFT calculations have been used to monitor both qualitative and quantitative structural changes of two well–characterized samples with BEA structure. The effects of various properties on stability were explored, including Al concentration, Al distribution, particle size and structural defects. As the samples were degraded by treatment in hot liquid water, the local structure about the Al T–site remained mostly intact, including the Al–O–Si angles and bond distances, while the nano–scale crystalline structure as measured by XRD and TEM was disrupted. The combined data suggest a three–step mechanism in which, initially, the HBEA framework crystallinity decreases via hydrolysis of T–O bonds along polymorph stacking faults and inter–grain boundaries in a mode similar to crack propagation in glass. With prolonged exposure, amorphization occurs via hydrolysis of surface Si–OH groups propagating inward through the zeolite lattice. In parallel, cracks propagate within the crystalline micro–domains along paths through specific T–O–T groups. Authors thank B. W. Arey (PNNL) for HIM measurements, T. Huthwelker for support during Al XAFS measurements at the Swiss Light Source (PSI, Switzerland) and M. Y. Hu (PNNL) for support during NMR experiments. This work was supported by the U. S. Department of Energy (DOE), Office of Science, Office of Basic Energy Sciences, Division of Chemical Sciences, Geosciences & Biosciences. NMR experiments were performed at the Environmental Molecular Science Laboratory, a national scientific user facility sponsored by the DOE’s Office of Biological and Environmental Research, and Physical Science Laboratory both located at Pacific Northwest National Laboratory (PNNL). PNNL is a multi–program national laboratory operated for DOE by Battelle under Contract No. DE–AC05–76RL01830.

Environmental Molecular Sciences Laboratory↗

A wide-field micro-computed tomography detector: micron resolution at half-centimetre scale

Ideal three-dimensional imaging of complex samples made up of micron-scale structures extending over mm to cm, such as biological tissues, requires both wide field of view and high resolution. For existing optics and detectors used for micro-CT (computed tomography) imaging, sub-micron pixel resolution can only be achieved for fields of view of <2 mm. This article presents a unique detector system with a 6 mm field-of-view image circle and 0.5 µm pixel size that can be used in micro-CT units utilizing both synchrotron and commercial X-ray sources. A resolution-test pattern with linear microstructures and whole adult Daphnia magna were imaged at beamline 8.3.2 of the Berkeley Advanced Light Source. Volumes of 10000 × 10000 × 7096 isotropic 0.5 µm voxels were reconstructed over a 5.0 mm × 3.5 mm field of view. Measurements in the projection domain confirmed a 0.90 µm measured spatial resolution that is largely Nyquist-limited. This unprecedented combination of field of view and resolution dramatically reduces the need for sectional scans and computational stitching for large samples, ultimately offering the means to elucidate changes in tissue and cellular morphology in the context of larger, whole, intact model organisms and specimens. This system is also anticipated to benefit micro-CT imaging in materials science, microelectronics, agricultural science and biomedical engineering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Chemical vapor deposition for silicon cladding on advanced ceramics

Polycrystalline Si was used to clad several advanced ceramic materials such as SiC, Si3N4, sapphire Al2O3, pyrolytic BN, and Si by a CVD process. The thickness of Si cladding ranged from 0.025 to 3.0 mm. CVD Si adhered quite well to all the above materials except Al3O, where the Si cladding was highly stressed and cracked or delaminated. A detailed material characterization of Si-clad SiC samples showed that Si adherence to SiC does not depend much on the substrate surface preparation; that the thermal cycling and polishing of the samples do not cause delamination; and that, in four-point bend tests, the Si-SiC bond remains intact, with the failure occurring in the Si.

Goela, Jitendra S.↗

Gas chromatographic column for the storage of sample profiles

The concept of a sample retention column that preserves the true time profile of an analyte of interest is studied. This storage system allows for the detection to be done at convenient times, as opposed to the nearly continuous monitoring that is required by other systems to preserve a sample time profile. The sample storage column is essentially a gas chromatography column, although its use is not the separation of sample components. The functions of the storage column are the selective isolation of the component of interest from the rest of the components present in the sample and the storage of this component as a function of time. Using octane as a test substance, the sample storage system was optimized with respect to such parameters as storage and readout temperature, flow rate through the storage column, column efficiency and storage time. A 3-h sample profile was collected and stored at 30 degrees C for 20 h. The profile was then retrieved, essentially intact, in 5 min at 130 degrees C.

NASA Program Exobiology↗

Pre-Transient Characterization of Historic EBR-II Pins for Transient Testing

Current interest in sodium-cooled fast reactor (SFR) designs, such as TerraPower’s Natrium Reactor, has highlighted the need for advanced reactor fuel technology development. Modern U-Zr and U- Pu-Zr pin designs are primary candidates to fuel SFRs and boast high fuel utilization capacity, increased fuel-cladding compatibility, and improved safety through inherent feedback mechanisms. Despite over 60 years of metallic fuel irradiation, uncertainties exist in the performance of the fuel system, particularly under transient overpower (TOP) and loss of flow (LOF) scenarios. Throughout historical testing within the Experimental Breeder Reactor II (EBR-II) and the Fast Flux Test Facility (FFTF), fuel behavior has demonstrated benign response to transient reactor conditions; however, accurate predictions of failure thresholds to inform operational limitations rely heavily on fuel composition, burnup, and irradiation history. In expanding TOP and LOF testing, the Transient Heat sink Overpower Response (THOR) Capsule will be used to test modern fuel technologies in a static sodium environment in the Transient Reactor Test (TREAT) Facility. The THOR capsule is highly instrumented and will provide time-dependent thermal behavior of SFR fuel pins subjected to accident conditions within TREAT. The THOR-Metallic (THOR- M) campaign aims to validate and expand historical TOP and LOF testing on high burnup U-Zr and U-Pu- Zr fuel alloys previously irradiated in EBR-II by running the rods to failure. This contribution focuses primarily on the pre-transient engineering-scale destructive and non- destructive characterization that has been conducted on both the test and sibling pins used for the TOP and LOF tests. All pins underwent visual examination, neutron radiography, element contact profilometry, and precise gamma scan. The sibling pins used for each test were further analyzed using gas assay, sampling, and recharge analysis (GASR), and optical microscopy. The results from each technique confirmed that the fuel pins were intact and devoid of any atypical developments when compared to historical data. Additionally, the analyzed measurements establish a baseline for comparison to post-transient analysis. Key fuel behaviors quanitifed include axial elongation of the fuel column, diametral strain of the pin, patterns in fluff structure geometry, changes in axial isotope distribution, evolution of constituent redistribution, porosity, and fission gas release. The pre-transient measurements and changes attributed to transient behavior from post-transient measurement will be compared to historical data to capture the behavioral dependence on composition, burnup, and irradiation history. Results from this work advance the initiatives of the THOR-M campaign, which aid in informing fuel performance models and establishing safety criteria for SFR operational limits. The novel combination of test environment, in-situ instrumentation, and comprehensive suite of characterization methods provides greater understanding of transient fuel behavior. Overall, information on the time and condition of pin failure for high burnup U-Pu-Zr will greatly expand the limited existing TOP and LOF test data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pre-Transient Characterization of Historic EBR-II Pins for Transient Testing

Current interest in sodium-cooled fast reactor (SFR) designs, such as TerraPower’s Natrium Reactor, has highlighted the need for advanced reactor fuel technology development. Modern U-Zr and U- Pu-Zr pin designs are primary candidates to fuel SFRs and boast high fuel utilization capacity, increased fuel-cladding compatibility, and improved safety through inherent feedback mechanisms. Despite over 60 years of metallic fuel irradiation, uncertainties exist in the performance of the fuel system, particularly under transient overpower (TOP) and loss of flow (LOF) scenarios. Throughout historical testing within the Experimental Breeder Reactor II (EBR-II) and the Fast Flux Test Facility (FFTF), fuel behavior has demonstrated benign response to transient reactor conditions; however, accurate predictions of failure thresholds to inform operational limitations rely heavily on fuel composition, burnup, and irradiation history. In expanding TOP and LOF testing, the Transient Heat sink Overpower Response (THOR) Capsule will be used to test modern fuel technologies in a static sodium environment in the Transient Reactor Test (TREAT) Facility. The THOR capsule is highly instrumented and will provide time-dependent thermal behavior of SFR fuel pins subjected to accident conditions within TREAT. The THOR-Metallic (THOR- M) campaign aims to validate and expand historical TOP and LOF testing on high burnup U-Zr and U-Pu- Zr fuel alloys previously irradiated in EBR-II by running the rods to failure. This contribution focuses primarily on the pre-transient engineering-scale destructive and non- destructive characterization that has been conducted on both the test and sibling pins used for the TOP and LOF tests. All pins underwent visual examination, neutron radiography, element contact profilometry, and precise gamma scan. The sibling pins used for each test were further analyzed using gas assay, sampling, and recharge analysis (GASR), and optical microscopy. The results from each technique confirmed that the fuel pins were intact and devoid of any atypical developments when compared to historical data. Additionally, the analyzed measurements establish a baseline for comparison to post-transient analysis. Key fuel behaviors quanitifed include axial elongation of the fuel column, diametral strain of the pin, patterns in fluff structure geometry, changes in axial isotope distribution, evolution of constituent redistribution, porosity, and fission gas release. The pre-transient measurements and changes attributed to transient behavior from post-transient measurement will be compared to historical data to capture the behavioral dependence on composition, burnup, and irradiation history. Results from this work advance the initiatives of the THOR-M campaign, which aid in informing fuel performance models and establishing safety criteria for SFR operational limits. The novel combination of test environment, in-situ instrumentation, and comprehensive suite of characterization methods provides greater understanding of transient fuel behavior. Overall, information on the time and condition of pin failure for high burnup U-Pu-Zr will greatly expand the limited existing TOP and LOF test data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Liquid Native MALDI Mass Spectrometry for the Detection of Protein-Protein Complexes

Native mass spectrometry (MS) encompasses methods to keep noncovalent interactions of biomolecular complexes intact in the gas phase throughout the instrument and to measure the mass-to-charge ratios of supramolecular complexes directly in the mass spectrometer. Electrospray ionization (ESI) in nondenaturing conditions is now an established method to characterize noncovalent systems. Matrix-assisted laser desorption/ionization (MALDI), on the other hand, consumes low quantities of samples and largely tolerates contaminants, making it a priori attractive for native MS. However, so-called native MALDI approaches have so far been based on solid deposits, where the rapid transition of the sample through a solid state can engender the loss of native conformations. Here we present a new method for native MS based on liquid deposits and MALDI ionization, unambiguously detecting intact noncovalent protein complexes by direct desorption from a liquid spot for the first time. To control for aggregation, we worked with HUαβ, a heterodimer that does not spontaneously rearrange into homodimers in solution. Screening through numerous matrix solutions to observe first the monomeric protein, then the dimer complex, we settled on a nondenaturing binary matrix solution composed of acidic and basic organic matrices in glycerol, which is stable in vacuo. The role of temporal and spatial laser irradiation patterns was found to be critical. Both a protein-protein and a protein-ligand complex could be observed free of aggregation. To minimize gas-phase dissociation, source parameters were optimized to achieve a conservation of complexes above 50% for both systems. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-AB-BRB-05: Toward a 2D Water-Equivalent Dosimetry Panel Using KCl:Eu2+

Purpose: KCl:Eu2+ storage phosphor shows promise for radiation therapy dosimetry. The purpose of this work is to investigate several important aspects of this material for potential commercial use. Methods: KCl:Eu2+ chips were fabricated and a conformal coating using Parylene was applied. Material’s dose response in a 6 MV beam was investigated using Monte-Carlo simulations. We attempted to micronize the materials using a spiral jet mill. As we did not have a water-free glovebox, we used commercially available non-hygroscopic BaFBr0.85I0.15:Eu2+ computed radiography material to test if a homogeneous panel can be made using micron-sized phosphors. Results: Dosimeters remained intact and showed no change in PSL intensity after eight hrs of submersion in water. We then optically bleached the samples for reuse, irradiated and immersed for another 24 hrs. We observed marginal worsening of the PSL signal for both the soaked and un-soaked chips. By contrast, we were unable to measure PSL intensity of the un-coated pellets due to these pellets dissolving within minutes of being immersed in water. MC data indicate that the micron-sized KCl:Eu2+ is predicted to have a nearly water-equivalent response. KCl:Eu2+ particles with a median size of 3 microns can be produced using a jet mill, which could be reduced further if necessary. While the particles tend to agglomerate over time when stored in a desiccator, they still possess favorable d50’s and d99’s even after 100 minutes, providing an adequate time window for making a panel via tape casting. A panel cast using optimized methods exhibits nearly perfect particle arrangement. Conclusions: Data shown here support ongoing efforts in fabricating a reusable, high resolution dosimetry panel in a water-free glovebox using micron-sized KCl:Eu2+ particles separated by water-equivalent polymers. The conformal coating thereafter will provide good humidity resistance. HL is the founder of DoseImaging, LLC that is exclusively dedicated to commercializing this technology.

60 APPLIED LIFE SCIENCES↗

Impact of Thermal Pretreatment Temperatures on Woody Biomass Chemical Composition, Physical Properties and Microstructure

Thermal pretreatment of biomass by torrefaction and low temperature pyrolysis has the potential for generating high quality and more suitable fuels. To utilize a model to describe the complex and dynamic changes taking place during these two treatments for process design, optimization and scale-up, detailed data is needed on the property evolution during treatment of well-defined individual biomass particles. The objectives of this study are to investigate the influence of thermal pretreatment temperatures on wood biomass biochemical compositions, physical properties and microstructure. Wild cherry wood was selected as a model biomass and prepared for this study. The well-defined wood particle samples were consecutively heated at 220, 260, 300, 350, 450 and 550 °C for 0.5 h under nitrogen. Untreated and treated samples were characterized for biochemical composition changes (cellulose, hemicellulose, and lignin) by thermogravimetric analyzer (TGA), physical properties (color, dimensions, weight, density and grindablity), chemical property (proximate analysis and heating value) and microstructural changes by scanning electron microscopy (SEM). Hemicellulose was mostly decomposed in the samples treated at 260 and 300 °C and resulted in the cell walls weakening resulting in improved grindability. The dimensions of the wood were reduced in all directions and shrinkage increased with increased treatment temperature and weight loss. With increased treatment temperature, losses of weight and volume increased and bulk density decreased. The low temperature pyrolyzed wood samples improved solid fuel property with high fuel ratio, which are close to lignite/bituminous coal. Morphology of the wood remained intact through the treatment range but the cell walls were thinner. Lastly, these results will improve the understanding of the property changes of the biomass during pretreatment and will help to develop models for process simulation and potential application of the treated biomass.

09 BIOMASS FUELS↗

Carbon isotope evidence for a magmatic origin for Archaean gold-quartz vein ore deposits

Sediments from three sites in the Santa Barbara Basin were examined with a 160X power light microscope and TEM equipment to characterize the magnetostatic bacteria (MB) in the samples. Both the free magnetite and the crystals in the MB in the samples had lengths from 40-60 nm in length and increased in size from one end to the next. An intact magnetosome was also observed. Scanning the sediments with saturation isothermal remanent magnetization (SIRM) and altering field demagnetization techniques using a SQUID magnetometer yielded coercivity spectra which showed that the primary remanence carrier in the sediments was single domain magnetite. Although it is expected that the predominance of the bacterial magnetite component will decrease with depth in the open ocean basin, single-domain bacteria as old as 50 Myr have been observed in oceanic sediments.

Burrows, D. R.↗

Gas release and ordering of carbon in the Allende meteorite

An attempt is made to ascertain whether the inert gas atoms leave their carrier phases by volume diffusion, with intact internal phase frameworks, or are instead expelled from the solids as a results of substantial rearrangement, during release from samples of the Allende carbonaceous meteorite. Gas release over the 300-1100 C range was followed by Raman spectroscopic studies in the 1360 and 1580/cm wavelength bands of carbon. The results obtained indicate that the gas release at high temperatures is causally related to the ordering of carbon.

Heymann, D.↗

Influence of ion-pairing reagents on the separation of intact glycoproteins using hydrophilic-interaction liquid chromatography - high-resolution mass spectrometry

Hydrophilic-interaction liquid chromatography (HILIC) of intact proteins offers high-resolution separations of glycoforms of glycoproteins differing in the number of (neutral) glycans. However, to obtain efficient separations it is essential that the positively charged sites of the proteins are shielded by acidic (negative) ion-pair reagents (IPRs), so as to enhance the contribution of the hydroxyl groups of the (neutral) sugars in the glycoprotein. Here, we studied the influence of various IPRs that differ in physico-chemical properties, such as hydrophobicity and acidity, on the capillary-scale HILIC separation of intact (glyco)proteins. We evaluated the use of fluoroacetic acid (MFA), difluoroacetic acid (DFA), trifluoroacetic acid (TFA), and heptafluorobutyric acid (HFBA) as diluents for sample preparation, as solvents for sample loading on a reversed-phase trap prior to the HILIC separation, and as mobile-phase components for HILIC and HILIC-MS. To reduce the contribution of ion-exchange interaction with the (silica-based) stationary phase, we used an acrylamide-based monolithic column. We studied the influence of the different IPRs on each step of the separation of a mixture of proteins of different size and hydrophilicity and on the separation of the five glycoforms of ribonuclease B. The content of IPR in the sample was shown not to affect the separation and the MS detection. However, a low content of TFA and DFA in the mobile phase is favourable, as it reduces adduct formation and leads to higher signal intensity. The optimized HILIC conditions successfully resolved nine major glycoforms groups of a ~40 kDa glycoprotein horseradish peroxidase (HRP), as an example of a complex glycoprotein.

59 BASIC BIOLOGICAL SCIENCES↗

Dividing the Concentrator Target From the Genesis Mission

The Genesis spacecraft, launched in 2001, traveled to a Lagrangian point between the Earth and Sun to collect particles from the solar wind and return them to Earth. However, during the return of the spacecraft in 2004, the parachute failed to open during descent, and the Genesis spacecraft crashed into the Utah desert. Many of the solar wind collectors were broken into smaller pieces, and the field team rapidly collected the capsule and collector pieces for later assessment. On each of the next few days, the team discovered that various collectors had survived intact, including three of four concentrator targets. Within a month, the team had imaged more than 10,000 fragments and packed them for transport to the Astromaterials Acquisition and Curation Office within the ARES Directorate at JSC. Currently, the Genesis samples are curated along with the other extraterrestrial sample collections within ARES. Although they were broken and dirty, the Genesis solar wind collectors still offered the science community the opportunity to better understand our Sun and the solar system as a whole. One of the more highly prized concentrator collectors survived the crash almost completely intact. The Genesis Concentrator was designed to concentrate the solar wind by a factor of at least 20 so that solar oxygen and nitrogen isotopes could be measured. One of these materials was the Diamond-on-Silicon (DoS) concentrator target. Unfortunately, the DoS concentrator broke on impact. Nevertheless, the scientific value of the DoS concentrator target was high. The Genesis Allocation Committee received a request for approximately 1 cm(sup 2) of the DoS specimen taken near the focal point of the concentrator for the analysis of solar wind nitrogen isotopes. The largest fragment, Genesis sample 60000, was designated for this allocation and needed to be precisely cut. The requirement was to subdivide the designated sample in a manner that prevented contamination of the sample and minimized the risk of losing or breaking the precious requested sample fragment. The Genesis curator determined that the use of laser scribing techniques to "cut" a precise line and subsequently cleave the sample (in a controlled break of the sample along that line) was the best method for accomplishing the sample subdivision. However, there were risks, including excess heating of the sample, that could cause some of the implanted solar wind to be lost via thermal diffusion. Accidentally breaking the sample during the handling and cleaving process was an additional risk. Early in fiscal year 2013, to address this delicate, complicated task, the ARES Directorate assembled its top scientists to develop a cutting plan that would ensure success when applied to the actual concentrator target wafer; i.e., to produce an approximately 1 cm(sup 2) piece from the requested area of the wafer. The team, subsequently referred to as the JSC Genesis Tiger Team, spent months researching and testing parameters and techniques related to scribing, cleaving, transporting, handling, and holding (i.e., mounting) the specimen. The investigation required considerable "thinking outside the box," and many, many trials using nonflight wafer analogs. After all preliminary testing, the following method was adopted as the final cutting plan. It was used in two final end-to-end practice runs before being used on the actual flight target wafer. The wafer was oriented on the laser cutting stage with the 100 and 010 directions of the wafer parallel to the corresponding X and Y directions of the cutting stage. The laser was programed to scribe 31 lines of the appropriate length along the Y stage direction. The programed scribe lines were separated by 5 micron in the X direction. The laser parameters were set as follows: (1) The laser power was 0.5 watts; (2) each line consisted of 50 passes, with the Z position being advanced 5 micron per pass; and (3) 30 s would elapse before the next line was scribed to allow for wafer cool down from any possible heating via the laser. The ablated material that "stuck" in the "scribe-cut" was removed from the "cut" using an ultrasonic micro-tool. After all the ablated silicon was removed from the wafer, the wafer was repositioned in exactly the same orientation on the laser stage. The laser was focused using the bottom of the wafer channel, and the 31-line scribing pattern described above was reprogrammed using the Z position of the groove bottom as the starting Z value instead of the top wafer surface, which was used previously. Upon completion of the second set of scribes, the ultrasonic micro-tool was again used to clean out the cut. The wafer was remounted on the stage in exactly the same orientation as before. The laser was again focused on the bottom of the groove. This time, however, the laser was.programed to scribe only one line down the exact center of the channel. The final scribe line consisted of 100 passes with a Z advance of 5 micron per pass and with the laser power set at 0.5 watts. As mentioned above, the final cutting plan was practiced in two end-to-end trials using non-flight, triangular-shaped silicon wafers similar in size and orientation to the actual DOS 60000 target sample. The actual scribing of the triangular-shaped wafers required scribing two lines and cleaving (i.e. scribe-cleave, then scribe-cleave) to obtain the piece requested for allocation. Early in December 2012, after many months of experiments and practicing and perfecting the techniques and procedures, the team successfully subdivided the Genesis DoS 60000 target sample, one of the most scientifically important samples from the Genesis mission (figure 2). On December 17, 2012, the allocated piece of concentrator target sample was delivered to the requesting principal investigator.The cutting plan developed for the subdivision of this sample will be used as the model for subdividing future requested Genesis flight wafers (appropriately modified for different wafer types).

Lauer, H. V., Jr.↗

NM-Scale Anatomy of an Entire Stardust Carrot Track

Comet Wild-2 samples collected by NASA s Stardust mission are extremely complex, heterogeneous, and have experienced wide ranges of alteration during the capture process. There are two major types of track morphologies: "carrot" and "bulbous," that reflect different structural/compositional properties of the impactors. Carrot type tracks are typically produced by compact or single mineral grains which survive essentially intact as a single large terminal particle. Bulbous tracks are likely produced by fine-grained or organic-rich impactors [1]. Owing to their challenging nature and especially high value of Stardust samples, we have invested considerable effort in developing both sample preparation and analytical techniques tailored for Stardust sample analyses. Our report focuses on our systematic disassembly and coordinated analysis of Stardust carrot track #112 from the mm to nm-scale.

Nakamura-Messenger, K.↗