SEARCH · Search NASA
Results for “integrated storage”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
HPC Infrastructure Security - Ensuring Storage and Network Safety, Integrity, Efficiency, and Performance [Slides]
The presentation focused on High Performance Computing (HPC) infrastructure security at Los Alamos National Laboratory in New Mexico.
Integrated Carbon Capture and Storage for North Dakota Ethanol Production
Presentation given at the 2022 Carbon Capture & Storage Summit covering the Red Trail Energy, LLC (RTE) CCS Project; advancements in net-negative emissions; and a summary of lessons learned.
Urban Combined Heat and Power with Integrated Renewables and Energy Storage
This project demonstrated how incorporating a diverse generation and storage portfolio allows an urban district energy system to improve its efficiency by at least 50% and increase its backup power by at least 40% with a return on investment of at least ten years. The improvement was evaluated against the baseline operations for two urban district energy systems (DESs): a synthetic DES and a George Washington University DES. The DES techno-economic framework we developed yields reliability, resilience, and vulnerability indices for urban DESs (including generation and storage) with designation of which technologies improve the security and resiliency metrics by at least 20% compared to the status quo. The indices are benchmarked against baseline scenarios, and cost projections (capital cost and return on investment) to achieve the 20% improvement are reported. The energy management system we developed to conduct these analyses was incorporated into a user-friendly interface that can be used for decision-making by a user with no technical or programming background.
A Simulation-Based Investigation on the Performance of a Hybrid Ground Source Heat Pump System Integrated with Thermal Energy Storage
Explore the source record for details and available documents.
NORTH DAKOTA INTEGRATED CARBON CAPTURE AND STORAGE COMPLEX FEASIBILITY STUDY
Presentation given at Energy Generation Conference, Bismarck, North Dakota on January 24, 2018.
A novel geothermal heat pump system integrated with underground thermal storage for shifting building electric demands
Explore the source record for details and available documents.
Urban Combined Heat and Power with Integrated Renewables and Energy Storage
District energy systems efficiently provide thermal energy to multiple buildings and facilities through a network of shared infrastructure. Frequently, district energy systems are centered around combined heat and power (CHP) plants that generate electricity as well as heating and cooling to the local buildings. By providing both electricity and thermal energy from a single fuel source and central location, these systems use less fuel, decrease energy and operational costs, and reduce the need for heating and cooling equipment in individual buildings.
Economic Analysis of an Electric Thermal Energy Storage System Using Solid Particles for Grid Electricity Storage
As renewable power generation becomes the mainstream new-built energy source, energy storage will become an indispensable need to complement the uncertainty of renewable resources to firm the power supply. When phasing out fossil-fuel power plants to meet the carbon neutral utility target in the midcentury around the world, large capacity of energy storage will be needed to provide reliable grid power. The renewable power integration with storage can support future carbon-free utility and has several significant impacts including increasing the value of renewable generation to the grid, improving the peak-load response, and balancing the electricity supply and demand. Long-duration energy storage (10–100 hours duration) can potentially complement the reduction of fossil-fuel baseload generation that otherwise would risk grid security when a large portion of grid power comes from variable renewable sources. Current energy storage methods based on pumped storage hydropower or batteries have many limitations. Thermal energy storage (TES) has unique advantages in scale and siting flexibility to provide grid-scale storage capacity. A particle-based TES system has promising cost and performance for the future growing energy storage needs. This paper introduces the system and components required for the particle TES to be technically and economically competitive. A technoeconomic analysis based on preliminary component designs and performance shows that the particle TES integrated with an efficient air-Brayton combined cycle power system can provide power for several days by low-cost, high-performance storage cycles. It addresses grid storage needs by enabling large-scale grid integration of intermittent renewables like wind and solar, thereby increasing their grid value. The design specifications and cost estimations of major components in a commercial scale system are presented in this paper. The cost model provides insights for further development and cost comparison with competing technologies.
Evaluation of Containment and Geomechanical Risks at Integrated Mid-Content Stacked Carbon Storage Hub Sites
The U.S. Department of Energy is leading the development of CCS through collaborative projects and programs to not only develop and demonstrate the technology but to also quantify the risks and provide tools that site operators can use to develop a site-specific understanding of their risk to enable successful project operations. This report summarizes results and findings from the application of risk-assessment tools to an industrial-scale Geologic Carbon Storage (GCS) project. Specifically, we applied the National Risk Assessment Partnership’s (NRAP) Open Integrated Assessment Model (NRAP-Open-IAM) and State of Stress Assessment Tool (SOSAT) to two candidate sites being considered for storage by the Integrated Midcontinent Stacked Carbon Storage Hub (IMSCS-Hub) project team. These sites, Sleepy Hollow Field in Nebraska and Patterson Field in Kansas, have historical oil and gas production and thus are attractive candidates to store the 50 million metric tons (Mt), which is the CarbonSAFE objective. Because these sites have historical operations, they have a significant number of existing wells that pose a risk for well leakage. Additionally, the storage formations will undergo significant pore pressure perturbation (i.e., increase due to CO 2 injection). Hence, we have selected the two NRAP tools best suited to study the risks associated with well leakage and geomechanical risks. The objective of the study was not only to assess the risk at the site, but to also improve the NRAP tools through application using real site data on an ongoing project.
Optimal Sizing of an Electric Vehicle Charging Station with Integration of PV and Energy Storage
This paper proposes an optimization model for the optimal configuration of an grid-connected electric vehicle (EV) extreme fast charging station considering integration of photovoltaic (PV) and energy storage. The proposed model minimizes the annualized net cost (i.e., maximizes the annualized net profit) of the extreme fast charging station, including investment and maintenance cost of charging ports, PV and energy storage, net cost of purchasing energy from utility and selling energy to EV customers, degradation cost of energy storage and demand charge. The decision variables are number of charging ports, capacity of invested PV and the power and energy ratings of invested energy storage. The Erlang-loss system is adopted to model the EV mobility. Results of numerical simulations indicate that investment of PV and energy storage could increase the annualized profit of the extreme fast charging station. In addition, the impacts of various parameters on the optimal solution are investigated by sensitivity analysis.
Economically Viable Intermediate to Long Duration Hydrogen Energy Storage Solutions for Fossil Fueled Assets
This report was prepared as an account of work sponsored by the Office of Fossil Energy and Carbon Management of U.S. Department of Energy under Funding Opportunity Announcement Number DE-FOA-0002332 “Energy Storage for Fossil Power Generation”. The work aimed to explore and advance an innovative hydrogen energy storage system – the synergistically integrated hydrogen energy storage system (SIHES) – that has the following characteristics: • Compatible with existing or new coal and gas fuel electricity generation units, • best suited for intermediate to long duration energy storage, from 12 hours to weeks even months, and • capable of storing energy at the utility scale – hundreds of MWh to GWh energy storage with power output level in tens to hundreds of MW. Preliminary front-end engineering design (Pre-FEED) studies was carried out to develop and refine a site-specific SIHES as peaking power generation units (so named as HyPeaker) as the first market entry point, to demonstrate both the technical feasibility and the economic viability to integrate the HyPeaker “within the fence” of a fossil power plant. This specific site was TVA’s Johnsonville Combustion Turbine Plant. The HyPeaker was designed and engineered to integrate with a 60MW aeroderivative gas turbine unit already available at TVA’s Johnsonville site. This site-specific HyPeaker consists of an alkaline electrolyzer to produce hydrogen from CO 2 free electricity sources, an innovative low-cost high-pressure hydrogen storage system (Big-Ton) and the aero gas turbine to generate electricity using blend of hydrogen and natural gas. A holistic system level technoeconomic analysis tool specific to HyPeaker was developed to optimize the engineering design of the Johnsonville site-specific HyPeaker for cost and performance. The optimal design and specification of the Johnsonville site-specific HyPeaker are the following: • Alkaline electrolyzer: 3MW • Big-Ton storage vessel: 11,000kg H 2 at 3000psi. • 4-stage diaphragm hydrogen compressor: 55kg-H 2 /hr from 150psi to 3000psi. The HyPeaker is designed to provide sufficient hydrogen for 90% continuous operation of the HyPeaker. All major components have design life of 30 years. The capex of HyPeaker is estimated at $\$$7.1M. This included $\$$1.5M for the electrolyzer, $\$$5.6M for the storage vessel and compressor. The cost of aero gas turbine was included as it is already available at the site. Key findings are: • HyPeaker can be designed, manufactured, installed and integrated with the fossil power plants, with sub-systems and components commercially available on the market today, even when it is scaled up to an order of magnitude larger than the one at the Johnsonville site. HyPeaker is a technologically viable solution to cover a wide range of energy storage duration needs, from daily peaking operation to seasonal shifting for fossil fueled assets. • The cost advantage of SCCV based Big-Ton H 2 storage vessel made it possible to “oversize” the H 2 storage subsystem to achieve overall system level cost optimization. The benefits are two-fold. First, it allows to significantly reduce the capacity and cost of electrolyzer by spreading H 2 production over a much longer period of time when the fuel cost for electricity production is low. Second, it allows to balance the hydrogen production and usage shift over weeks to months to meet the peak demands. As such, the capital cost of HyPeaker system using the Big-Ton was less than half of the cost of a system with today’s steel tube based H 2 storage system. The HyPeaker has even better cost advantage Li-ion battery based energy storage system. The estimated capital cost of Li-Ion battery system would be at $\$$38M, under the same projected 20-year electricity generation profile of the Johnsonville site. This is over 5 times more expensive than the HyPeaker system. • Since industry scale energy storage systems do not have 100% energy conversion and storage efficiency, energy storage systems using fossil fuel generated electricity would increase the CO 2 emission. This is particularly the case for HyPeaker due to its low round trip efficiency. Therefore, a more sensible solution would be to the excessive or curtailed electricity from CO 2 emission free sources such as solar farms, wind farms or nuclear power plants, to produce hydrogen, and integrate them with the HyPeaker. Electricity from TVA’s nuclear power plants was used for the Johnsonville HyPeaker. • The economic viability of HyPeaker is expected to be further improved when global supply chains are taken into consideration. For the same Johnsonville site specific HyPeaker, the capex would be reduced to ~$\$$3.6M from ~$\$$7.1M, and the added LCOE is reduced to ~$\$$85/MWh. With the bipartisan Infrastructure Investment and Jobs Act, the cost of domestically produced HyPeaker sub-systems would be at the level of today’s global suppliers. Since the peaking units generally operate at peak usage period, thereby demanding higher price, the projected $\$$85/MWh LCOE would be within the realm of financial viability for utility operators.
Expanding market opportunities: cogeneration strategies for integrated PWR and thermal energy storage systems
We assess the economic viability of nuclear cogeneration by investigating three different modes—fixed dispatch, fully flexible dispatch, and flexible dispatch with minimum heat supply requirements. The analysis focuses on an existing pressurized water reactor (PWR) integrated with thermal energy storage (TES). Heat production costs are estimated under these modes for two U.S. electricity markets: the Electric Reliability Council of Texas (ERCOT) and the Pennsylvania–New Jersey–Maryland Interconnection (PJM). A sensitivity analysis examines profitability at varying heat market prices. Results indicate that fixed heat dispatch inflates heat production costs, often rendering projects economically feasible only at higher heat price levels. Fully-flexible dispatch lowers heat production costs by an average of 43 % compared to fixed dispatch. However, the current 30 % thermal dispatch limit may be insufficient to serve high baseline industrial demands cost‐effectively; higher maximum dispatch rates could enhance project economics. Markets with higher and more volatile electricity prices (e.g., ERCOT) offer greater total energy sales potential (i.e., heat and electricity), but also increase opportunity costs when heat production scheduling restrictions are imposed. In contrast, lower-price, less volatile markets (e.g., PJM) experience smaller impacts from such constraints and provide greater flexibility in accommodating varying cogeneration modes. In conclusion, these findings provide a framework to guide nuclear plant operators in aligning cogeneration strategies with industrial process requirements and electricity market conditions.
Extending Rucio with modern cloud storage support
Rucio is a software framework designed to facilitate scientific collaborations in efficiently organising, managing, and accessing extensive volumes of data through customizable policies. The framework enables data distribution across globally distributed locations and heterogeneous data centres, integrating various storage and network technologies into a unified federated entity. Rucio offers advanced features like distributed data recovery and adaptive replication, and it exhibits high scalability, modularity, and extensibility. Originally developed to meet the requirements of the high-energy physics experiment ATLAS, Rucio has been continuously expanded to support LHC experiments and diverse scientific communities. Recent R&D projects within these communities have evaluated the integration of both private and commercially-provided cloud storage systems, leading to the development of additional functionalities for seamless integration within Rucio. Furthermore, the underlying systems, FTS and GFAL/Davix, have been extended to cater to specific use cases. This contribution focuses on the technical aspects of this work, particularly the challenges encountered in building a generic interface for self-hosted cloud storage, such as MinIO or CEPH S3 Gateway, and established providers like Google Cloud Storage and Amazon Simple Storage Service. Additionally, the integration of decentralised clouds like SEAL is explored. Key aspects, including authentication and authorisation, direct and remote access, throughput and cost estimation, are highlighted, along with shared experiences in daily operations.
Real-time well integrity monitoring in underground gas storage wells using distributed temperature and strain sensing: a field demonstration
Here, this article presents the first successful field demonstration of a combined distributed temperature and strain sensing (DTSS) system installed directly on newly replaced tubing in a 5400-ft-deep operational underground gas storage well. The DTSS system uses a single optical fiber to monitor temperature and strain in real-time, providing a cost-effective solution for long-term well integrity assessment. In this study, the strain–stress correlation of the tubing—representative of material behavior analysis—is investigated as a potential method for monitoring tubing integrity throughout its lifetime. Moreover, the DTSS system’s capability to support both continuous and discrete monitoring is evaluated by comparing future data with historical records, enabling the early detection of issues such as material fatigue, corrosion, or deformation. Overall, the work examines the effectiveness and scalability of the DTSS system for real-time monitoring of well operations and integrity in a newly replaced well.
Phase I: Natural Gas-Based Energy Storage at Abbott Power Plant
Compressed Natural Gas Energy Storage (CNGES), uses the potential energy of compressed natural gas within an integrated energy storage system. Specifically, an inventory of high-pressure natural gas is stored during off-peak hours in a first stage by controlling the balance of gas entering a pipeline from the transmission system, and in a second stage by using new compressors to fill vessels onsite. The natural gas storage medium is then discharged through an expander-generator to use the potential energy from the gas to generate electricity without combustion. The excess chemical energy stored in the natural gas is integrated with an existing fossil-based asset to provide power generation during peak hours and increase the reliability of the associated fossil generating facility.
Carbon Capture and Storage for Small-to-Medium Biorefineries: Promising Carbon Removal Solution with Economic Challenges
Carbon capture and storage (CCS) integrated with biomass-based fuel production can provide cost-effective biomass carbon removal and storage (BiCRS) and produce high-value bioproducts, such as sustainable aviation fuels. To accelerate BiCRS deployment, it is crucial to quantify the costs of CCS integration, particularly for small- and medium-scale biorefineries that are representative of early-stage deployment. Existing studies tend to focus on plant sizes that are orders-of-magnitude larger than early-stage installations, possibly underestimating CCS costs for small-to-medium biorefineries. We show that the capture, transport, and storage costs to maximize CO 2 removal from a 526 dry tonne per day (tpd) biomass gasification plant (largest existing size) could be 13–47% higher than costs for a typical modeled plant size (2000 dry tpd). The higher cost estimates are driven by less favorable economies of scale and realistic assumptions about the availability of affordable CO 2 transport infrastructure with both drivers broadly applicable to other BiCRS technologies. Compliance and voluntary carbon markets could incentivize biorefinery CCS, but both carry a high degree of uncertainty. In conclusion, these findings highlight that sufficient and reliable financial mechanisms would be essential to unlocking the full CO 2 removal potential of biorefineries and facilitating BiCRS scale-up.