Search NASA⌕ Search

SEARCH · Search NASA

Results for “interfacial heat transfer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

186 records · Page 11

Energetics and Structure of Nickel Atoms and Nanoparticles on MgO(100)

The growth morphology and interfacial energetics of vapor deposited Ni on the MgO(100) surface at 300 and 100 K have been studied using single crystal adsorption calorimetry (SCAC), He + low-energy ion scattering spectroscopy (LEIS), X-ray photoelectron spectroscopy (XPS), and low-energy electron diffraction (LEED). At 300 K, the Ni atoms grow as three-dimensional nanoparticles with a saturation number density of 5 × 10 16 particles/m 2 . The differential heat of adsorption at 300 K increases rapidly with coverage, from 276 (initially) to 311 kJ/mol by 0.4 ML. Thereafter, it slowly increases asymptotically to the sublimation enthalpy of bulk Ni (430 kJ/ml) by 9 ML. The Ni 2p 3/2 XPS peak binding energy at 300 K is initially (i.e., at 0.16 ML) 1.4 eV higher than that for bulk Ni(solid), but it decreases to that value at high coverage. The Ni atoms form a metastable phase at 300 K when in nanoparticles with diameter <2.5 nm, and the adhesion energy of such Ni nanoparticles to MgO(100) was found to be 3.05 J/m 2 . At 100 K, the Ni atoms form single adatoms and then 0.17 nm thick 2D islands at low coverage with fewer Ni-Ni bonds compared to the Ni nanoparticles formed at 300 K. Thus, the initial heat (i.e., for the first ~0.03 ML) is 148 kJ/mol at 100 K, 128 kJ/mol lower than at 300 K, and remains lower for the 2D islands. With increasing coverage at 100 K, the tiny 2D Ni islands grow in size to cover nearly the entire surface before thickening. Lastly, the XPS Ni 2p 3/2 peak binding energy for 0.21 ML Ni on MgO(100) at 100 K is 2.2 eV higher than that for bulk Ni(solid), suggesting charge transfer from Ni to MgO(100) and formation of Ni 2+ at very low coverage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling and Simulation of Fuel Dispersal During the Loss-of-Coolant Accident

This document is the compilation of the milestone portion to a larger end of project NEUP report. The executive summary of the modeling portion is provided below: In the event of cladding rupture during a postulated LOCA in a pressurized water reactor, fuel particles, along with fission gases, can be expelled into the reactor core from the fractured fuel rod, a phenomenon referred to as fuel dispersal. The initial stage of fuel dispersal is strongly influenced by the high-pressure ejection of fuel fragments, the size and geometry of the ruptured cladding, and the depressurization history of the fuel rod during the postulated LOCA transient. Depending on the location of the burst orifice relative to the quench front, the dispersal event represents an intricate three-phase flow and heat transfer phenomenon, where high-temperature fuel particles carried by the fission gases interact with the coolant within the narrow subchannels of the fuel assemblies, inducing localized phase change. Given the unique multiphysics nature of this phenomena, the current study develops a dedicated computational framework to predict the mass distribution and cooling of dispersing fuel particles, facilitating post-accident assessment and management of the fuel assemblies. Considering the scale of nuclear reactor applications, a continuum three-fluid model is proposed for simulating the transport of solids within the reactor core. With high-temperature fuel fragments within the liquid media, nucleation sites inducing phase changes are dispersed within the flow domain. Coupled with the fact that the transient dispersal event occurs on different time scales than other three-phase flow applications, this study derives a time-averaged three-fluid flow model without losing generality. The assumptions regarding the continuum treatment of the solid phase and the modeling of fuel dispersal behavior are incorporated to simplify the governing equations and derive applicable closure relations. The computational validation of the model was conducted using adiabatic experimental results obtained from ongoing research at Oregon State University, focusing on characterizing fuel dispersal behavior during simulated LOCA conditions. Settlement characteristics of the solids, quantified by the probability distribution of equivalent particles, closely matched the probability density functions reported in experimental studies. The transport of fuel particles within a scaled 5 × 5 lattice of a pressurized-water reactor rod bundle geometry was modeled through a two-fluid Eulerian framework. The required boundary conditions were evaluated from the fuel performance code BISON in a postulated large-break LOCA scenario. The modeling framework considered solid fuel particles as granular matter, interacting with the gaseous dry steam phase and fission gases through the governing interfacial momentum exchange between the participating fluids. The simulation results provided the volume fraction of the solids obtained at the bottom surface of the enclosing tank geometry. Postulated LOCA leading to fuel dispersal phenomena involves the strong coupling between fuel thermomechanics, cladding deformation, thermal-hydraulics, and fuel particle transport. Incorporation of such a strong coupling in numerical simulation is performed by coupling the multiphysics solvers. In the case of fuel dispersal, a strong coupled simulation can be performed by coupling the BISON code for fuel performance, the TRACE code for system-level thermal hydraulics, and fuel particle transport in Multiphysics Object-Oriented Simulation Environment (MOOSE). For such intricate infrastructure, the MOOSE Framework eases the data transfer between codes. The recent version of MOOSE has incorporated the Navier-Stokes module for the fluid flow. An exploratory exercise was done to gain familiarity with finite volume capabilities in the MOOSE framework to incorporate the Spalart-Allmaras (SA) turbulence model. New finite-volume and auxiliary kernels were introduced to assemble the SA transport equation, compute turbulent viscosity, and evaluate wall distance and diagnostic turbulence terms, fully integrated with existing Navier-Stokes modules. A turbulent lid-driven cavity at a Reynolds number of approximately 10,000 is used for verification. MOOSE shows the robust solver convergence and produces the turbulent features. But it underpredicts the velocity profile and turbulent quantities, emphasizing the need to develop improved SA near-wall treatments (e.g., low-Re corrections or wall functions) as a key direction for future work.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Challenges and Opportunities in Gen3 Embedded Cooling with High-Quality Microgap Flow

Gen3, Embedded Cooling, promises to revolutionize thermal management of advanced microelectronic systems by eliminating the sequential conductive and interfacial thermal resistances which dominate the present 'remote cooling' paradigm. Single-phase interchip microfluidic flow with high thermal conductivity chips and substrates has been used successfully to cool single transistors dissipating more than 40kW/sq cm, but efficient heat removal from transistor arrays, larger chips, and chip stacks operating at these prodigious heat fluxes would require the use of high vapor fraction (quality), two-phase cooling in intra- and inter-chip microgap channels. The motivation, as well as the challenges and opportunities associated with evaporative embedded cooling in realistic form factors, is the focus of this paper. The paper will begin with a brief review of the history of thermal packaging, reflecting the 70-year 'inward migration' of cooling technology from the computer-room, to the rack, and then to the single chip and multichip module with 'remote' or attached air- and liquid-cooled coldplates. Discussion of the limitations of this approach and recent results from single-phase embedded cooling will follow. This will set the stage for discussion of the development challenges associated with application of this Gen3 thermal management paradigm to commercial semiconductor hardware, including dealing with the effects of channel length, orientation, and manifold-driven centrifugal acceleration on the governing behavior.

microchannel↗

Development of a Comprehensive Two-Phase Flow Database for the Validation of NEK-2P

Three-dimensional (3-D) two-phase Computational Fluid Dynamics (CFD) codes are emerging as a powerful and potentially practical tool for applications in which detailed local flow information is needed. However, two-phase flow models and associated closure relations are not well established for CFD applications, which is partly due to the lack of high-quality validation data. The main objective of this work is to develop a comprehensive database of two-phase flows that can be used to validate two-phase CFD codes such as NEK-2P. In this project, four advanced local measurement systems, including Particle Image Velocimetry and Planar Laser-Induced Fluorescence (PIV-PLIF), high-speed imaging, x-ray densitometry, and multi-sensor conductivity probe are employed to measure the local two-phase flow parameters of both gas and liquid phases. By combining these techniques, the local void fraction, bubble velocity, interfacial area concentration, bubble frequency, liquid velocity, turbulence intensity, etc., in various two-phase flow regimes can be obtained. These local measurement techniques are first used in a 25.4 mm circular pipe test section. Seven air-water two-phase flow conditions spanning the bubbly, slug, churn-turbulent, and annular flow regimes are measured in this facility. The obtained database contains the radial profiles of both gas- and liquid-phase parameters at three axial locations along the test section. The second facility used in this work contains a 30 mm × 10 mm rectangular test section, in which three two-phase flow and two single-phase flow conditions are measured. Two-dimensional distributions of local two-phase flow parameters in the cross-sectional plane are measured in this facility at three axial locations as well. A facility featuring a 3×3 electrically heated rod bundle is also designed and being constructed in this project. This facility is specially designed for optical measurements and is expected to provide high-quality boiling data in the future. Preliminary analyses have been performed for the data taken in the 25.4 mm circular pipe. Both center-peaked and wall-peaked void fraction profiles have been observed in the data depending on the two-phase flow conditions and/or developing lengths. The 1-D drift-flux model was evaluated with the newly obtained datasets, in which both gas- and liquid-phases data were directly measured. The distribution parameter model has been optimized based on a new void-profile classification method proposed in this study. The optimized drift-flux model shows a significant improvement in predicting both gas velocity and void fraction. The measured liquid-phase turbulence was used to benchmark Sato’s turbulence model considering the bubble-induced shear stress for the three tested bubbly flows. The benchmark results showed good agreement between the PIV measurements and model predictions. In the bubbly flows tested that have low void fractions less than 3%, the effect of the bubble-induced turbulence was found not significant. However, the bubble-induced shear stress becomes important with the increase of the void fraction. The Conjugate Heat Transfer (CHT) model was developed and implemented in NEK-2P. This model allows the coupled simulation of the solid domain and two-phase fluid domain, allowing the specification of realistic boundary conditions. The CHT implementation was verified first with non-boiling simulations. The predicted temperatures in the fluid domain were shown to be identical in simulations with or without the CHT model. The CHT model was then validated through simulations of three Becker benchmark CHF tests performed under both Dryout (DO) and Departure from Nucleate Boiling (DNB) conditions. Reasonably good agreement was obtained between calculated wall temperatures and corresponding experimental data.

42 ENGINEERING↗

Validation of RELAP-7 for Forced Convective and Natural Circulation Reactor Flows

New reactor designs such as small modular reactors and newly proposed passive safety systems rely on natural circulation two-phase flow cooling of the reactor core under accident conditions. Without a pump to drive the flow, the circulation rate is a strong function of void fraction. Under these conditions where the flow rate, pressure drop, and heat transfer are all closely coupled through the mixture density, the accurate prediction of void fraction is pivotal. Furthermore, while these passive systems boast a more reliable cooling option, the sensitivity of the system to two-phase flow instabilities is more likely than in forced convective cooling and can result in dangerous density wave or flow excursion conditions. Improvement of one-dimensional system codes and further development of three-dimensional code capability are all important efforts in addressing these issues. The proposed work is a critical step towards providing confidence through validation of the capability of thermal-hydraulic tools to meet the emerging challenges in reactor simulation. Historically, system analysis codes develop a stiffness over time due to fine-tuning of adjustable code parameters that result in a reluctance or inability to adopt improved models. Therefore, a rigorous effort should be invested in preparation for RELAP-7 to identify required modeling improvements of constitutive relations and validation of the code applicability to the wide range of possible reactor flow conditions. Part of this validation involves the uncertainty quantification which is a critical step in the Code Scaling, Applicability, and Uncertainty (CSAU) methodology and Best-Estimate Plus Uncertainty (BEPU) licensing method. BEPU allows recovery of safety margins and potentially optimizing plant performance, resulting in economic benefit for the reactor operators. Beginning with the collection of past experimental data covering prototypic LWR conditions, this document reviews three critical datasets available for the validation of system codes. The experimental methods, procedures, facilities, instrumentation, and supplementary information are consolidated to aid the validation efforts of this work and future projects. These three datasets (824 conditions) are chosen due to their wide acceptance and demonstrated application for code validation. Two experimental datasets from the Nuclear Power Engineering Corporation (NUPEC) span prototypic conditions of Boiling Water Reactors (BWR) and Pressurized Water Reactors (PWR). These datasets are labeled as the BFBT (BWR Full-size Fine-mesh Bundle Test) and the PSBT (PWR Subchannel and Bundle Test) datasets respectively. The third dataset is taken in an internally heated annulus that is scaled based on a BWR subassembly and includes two-phase flows important to post-blowdown analysis. Together, the datasets consider the full range of pressure and mass flux expected in LWR forced convective flows from steady-state to long term cooling conditions. Recognizing the deficiency of available data under low-pressure, low-flow, a new natural circulation dataset consisting of 107 conditions is obtained. With system pressures ranging between 145 and 950 kPa, natural circulation is driven by a heat flux up to 275 kW/m2 in a 3 m long heated region of the annulus test section which is followed by a 2 m long unheated region before entering a condenser. Stable natural circulation flow rates in this facility were measured to be between 182 and 590 kg/m2-s. Pressure and temperature are measured at ten locations in the facility. In addition, measurements of void fraction, interfacial area concentration, and gas velocity are obtained at five axial locations in the annulus test section. The RELAP5-3D code demonstrates good accuracy for void fraction predictions in BFBT and PSBT benchmarks, but shows relatively large discrepancy in the annulus experiments at lower pressures. In two-phase natural circulation, large oscillations are observed in many system parameters during the simulation of 19 experiment cases which were conducted at low pressures, and the model shows good predictive performance with the remaining 88 experiment cases. However, some discrepancies in void fraction and temperature predictions are found which may require improved constitutive modeling under these low-pressure, low-flow condition. The quantified uncertainty in void fraction predictions in three forced convection benchmarks due to uncertainties in boundary conditions and geometries are relatively small, except for a few cases in the annulus experiment. The output uncertainty of the natural circulation model is quantified by considering the measurement error in boundary conditions, and it is shown that the output uncertainty ranges are relatively small for the range of conditions considered. Through this work, a clear pathway is provided for validation of RELAP7 once the code is available.

42 ENGINEERING↗

Ultrafast low-temperature metal–insulator interface phonon dynamics and heat transport in a Pt/Gd 3 Fe 5 O 12 heterostructure

Interfacial thermal and acoustic phenomena have an important role in quantum science and technology, including in spintronic and spincaloritronic materials and devices. Simultaneous measurements of the low-temperature thermal and acoustic properties of a metal/insulator heterostructure reveal distinct dynamics in the characteristic phonon frequency ranges of acoustic and thermal transport. The measurements probed a heterostructure consisting of a thin film of Pt on the ferrimagnetic insulator gadolinium iron garnet (Gd 3 Fe 5 O 12 , GdIG) grown epitaxially on a gadolinium gallium garnet substrate. Ultrafast structural dynamics within the Pt layer were tracked using time-resolved ultrafast x-ray diffraction and analyzed to probe interfacial acoustic and thermal properties. The rapid heating of the Pt layer by a 400 nm wavelength femtosecond-duration optical pulse produced transient structural changes that provided the stimulus for these measurements. Rapid heating produced a broadband acoustic pulse that was partially reflected by the Pt/GdIG interface. Temporal frequencies up to 740 GHz, corresponding to angular frequencies of several THz, were detected in a wavelet analysis of the acoustic oscillations of the strain in the Pt layer. The structural results were analyzed to determine (i) the acoustic damping coefficient and phonon mean free path in Pt at frequencies of hundreds of GHz and (ii) the Grüneisen anharmonicity parameter. The thermal conductance of the Pt/GdIG interface was tracked using the slower, tens-of-picosecond-scale, dynamics of the initial cooling of the heated Pt layer. Analysis using a model based on the Boltzmann transport equation shows that the phonon transmission is lower at the phonon frequencies relevant to thermal transport than for subterahertz regime acoustics.

Acoustic phenomena↗