Search NASA⌕ Search

SEARCH · Search NASA

Results for “interrupt”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Analytical Modeling of Biomass Transport and Feeding Systems

The processing of biomass solids in a biorefinery consists of pretreatment, enzyme hydrolysis / concurrent fermentation of sugars to ethanol, product recovery, and drying. Sustainable operation requires a front end that transforms wet solids into a pumpable slurry. Otherwise the biorefinery will suffer unscheduled shut-downs and inefficient operation due to solids that obstruct pumps and other equipment and resist mixing in a bioreactor. Downtime in pioneer biorefineries due to interruptions from materials handling problems has been 50% or more, leading to unsustainable manufacturing processes. This work addresses new technology, predictive computational models, and definition of operational conditions that result in formation of slurries of corn stover at up to 300 g/L using low enzyme loadings (1 to 3 FPU cellulase/g) before the biomass (corn stover) enters the pretreatment step. A team of researchers from Purdue University, Idaho National Laboratory (INL), Forest Concepts, AdvanceBio, Argonne National Laboratory, and DOE BETO have combined their knowledge in agricultural and biological engineering, bioprocess engineering, mechanical engineering, chemical engineering, agricultural economics, materials engineering and enzyme and microbial technology to address the challenge of making lignocellulose flow. This team effort has resulted in the development and validation of conditions that employ low levels of commercial enzyme in an agitated bioreactor to which corn stover pellets are added resulting in formation of slurries at high solids loadings, before pretreatment. This approach overcomes challenges caused by handling of dry, particulate biomass materials at the front end of the biorefinery. The subsequent materials handling issues cause obstruction at pumps, pipes and valves. Formation of high loadings slurries with low yield stress, as reported here, significantly decreases the potential for process interruption and enhances plant operability. Key advances in the knowledge of how slurry formation occurs is reported here and in recently published journal papers. We found that pellets are needed to achieve high solids loading, and that commercial enzymes are effective in forming slurries of corn stover particles from pellets that have not been pretreated. Our work has resulted in models that predict solids behavior for formation of compressed solids and pellets that in turn facilitate slurries made of high concentrations of corn stover particles. A computational model was developed that gives mechanistic insights into properties of particles and mixing process that gives the slurry rheology needed to facilitate pumping. Hence, the corn stover may be pumped into a pretreatment reactor in place of auguring in solids against high pressure which is a root cause of interruptions at the front end of a biorefinery. Subsequent mixing in enzyme and microbial bioreactors results in conversion of lignocellulose to sugars in a biorefinery in agitated bioreactors, with flows in and out of the vessels being less likely to be interrupted due to plugging or materials handling problems. The obtained data coupled to process models, techno-economic assessment (TEA) and Life Cycle Analysis (LCA) were used to assess whether this approach is practical. These results are based on a foundation of laboratory characterization and pilot runs. The NREL biochemical sugar model was utilized to carry out techno-economic analysis of enzyme catalyzed liquefaction followed by enzyme hydrolysis. The minimum sugar selling price was between 17.5 and 18.3 ¢/pound or about the same as calculated by the NREL model for dilute acid pretreatment followed by enzyme hydrolysis. Life cycle analysis (LCA) based on Argonne’s Greet Model showed the enzyme catalyzed route had the lowest greenhouse gas emissions of the three combinations studied (i.e., enzyme, enzyme mimetic, and enzyme + mimetic combined). GHG emissions for enzyme-based corn stover liquefaction step, alone, were about 21 g CO 2 -equivalent/kg of liquefied slurry. We believe this approach will further enhance operability of a pioneer biorefinery, and bring large-scale conversion of lignocellulosic biomass to low carbon footprint biofuels closer to implementation.

09 BIOMASS FUELS↗

Fault-free validation of a fault-tolerant multiprocessor: Baseline experiments and workoad implementation

In the future, aircraft employing active control technology must use highly reliable multiprocessors in order to achieve flight safety. Such computers must be experimentally validated before they are deployed. This project outlines a methodology for doing fault-free validation of reliable multiprocessors. The methodology begins with baseline experiments, which test single phenomenon. As experiments progress, tools for performance testing are developed. This report presents the results of interrupt baseline experiments performed on the Fault-Tolerant Multiprocessor (FTMP) at NASA-Langley's AIRLAB. Interrupt-causing excepting conditions were tested, and several were found to have unimplemented interrupt handling software while one had an unimplemented interrupt vector. A synthetic workload model for realtime multiprocessors is then developed as an application level performance analysis tool. Details of the workload implementation and calibration are presented. Both the experimental methodology and the synthetic workload model are general enough to be applicable to reliable multi-processors besides FTMP.

Feather, F.↗

Active hold-down for heat treating

The object of the disclosure is to provide a vacuum hold-down for holding thin sheets to a support surface, which permits the thin sheet to change dimensions as it is held down. The hold-down includes numerous holes in the support surface, through which a vacuum is applied from a vacuum source. The holes are arranged in zones. The vacuum is repeatedly interrupted at only one or a few zones, while it continues to be applied to other zones, to allow the workpiece to creep along that interrupted zone. The vacuum to different zones is interrupted at different times, as by a slowly turning valve number, to allow each zone of the workpiece to creep. A positive pressure may be applied from a pressured air source to a zone when the vacuum is interrupted there, to help lift the corresponding workpiece zone off the surface to aid in creeping. The workpiece may undergo dimensional changes because of heating, cooling, drying, or other procedure.

Collins, E. R., Jr.↗

Validation of a fault-tolerant multiprocessor: Baseline experiments and workload implementation

In the future, aircraft must employ highly reliable multiprocessors in order to achieve flight safety. Such computers must be experimentally validated before they are deployed. This project outlines a methodology for validating reliable multiprocessors. The methodology begins with baseline experiments, which tests a single phenomenon. As experiments progress, tools for performance testing are developed. The methodology is used, in part, on the Fault Tolerant Multiprocessor (FTMP) at NASA-Langley's AIRLAB facility. Experiments are designed to evaluate the fault-free performance of the system. Presented are the results of interrupt baseline experiments performed on FTMP. Interrupt causing exception conditions were tested, and several were found to have unimplemented interrupt handling software while one had an unimplemented interrupt vector. A synthetic workload model for realtime multiprocessors is then developed as an application level performance analysis tool. Details of the workload implementation and calibration are presented. Both the experimental methodology and the synthetic workload model are general enough to be applicable to reliable multiprocessors beside FTMP.

Feather, Frank↗

A High Temperature Vapor Phase Lubrication Study Utilizing a Thioether Liquid Lubricant

Much of the experimental work on vapor phase lubrication has employed certain organo phosphorous compounds as the vapor phase lubricant. Graham and Klaus, for instance, used tricresyl phosphate (TCP) and tributyl phosphate to vapor phase lubricate a four-ball wear tester using M50 steel balls at 370 C. Makki and Graham were able to vapor phase lubricate a reciprocating pin on plate tribometer using 1018 steel at 280 C with TCP vapor. Although a few organo phosphorous compounds, such as TCP, have been successfully used as vapor phase lubricants in many laboratory experiments, many problems remain unsolved. Two areas of concern relate to the 'durability' of phosphate deposited films and to the ability of the lubricating system to "self-recover" when vapor phase lubricated with an organo phosphorous compound. Durability refers to the ability of the deposited film to provide effective lubrication, for a period of time, after the vapor flow to the lubricating surfaces has been interrupted. Vapor phase lubrication tests, conducted at Cleveland State University with their high temperature tribometer, revealed that when TCP vapor flow to the lubricating surfaces was interrupted the frictional coefficient of the system rapidly increased from a value less than 0.1 to a value of 0.3 which was selected as our failure point. Self-recovery means the ability of the vapor phase lubricant to reduce the frictional coefficient of the lubricating system back down to value less than 0.1 after startup of the interrupted vapor flow. Lubrication tests conducted at Cleveland State University revealed that the high temperature tribometer could not self-recover after startup of the interrupted TCP vapor flow.

Morales, Wilfredo↗

The anabolic activity of bone tissue, suppressed by disuse, is normalized by brief exposure to extremely low-magnitude mechanical stimuli

It is generally believed that mechanical signals must be large in order to be anabolic to bone tissue. Recent evidence indicates, however, that extremely low-magnitude (<10 microstrain) mechanical signals readily stimulate bone formation if induced at a high frequency. We examined the ability of extremely low-magnitude, high-frequency mechanical signals to restore anabolic bone cell activity inhibited by disuse. Adult female rats were randomly assigned to six groups: baseline control, age-matched control, mechanically stimulated for 10 min/day, disuse (hind limb suspension), disuse interrupted by 10 min/day of weight bearing, and disuse interrupted by 10 min/day of mechanical stimulation. After a 28 day protocol, bone formation rates (BFR) in the proximal tibia of mechanically stimulated rats increased compared with age-matched control (+97%). Disuse alone reduced BFR (-92%), a suppression only slightly curbed when disuse was interrupted by 10 min of weight bearing (-61%). In contrast, disuse interrupted by 10 min per day of low-level mechanical intervention normalized BFR to values seen in age-matched controls. This work indicates that this noninvasive, extremely low-level stimulus may provide an effective biomechanical intervention for the bone loss that plagues long-term space flight, bed rest, or immobilization caused by paralysis.

Non-NASA Center↗

Calculation of Flight Deck Interval Management Assigned Spacing Goals Subject to Multiple Scheduling Constraints

The Federal Aviation Administration's Next Generation Air Transportation System will combine advanced air traffic management technologies, performance-based procedures, and state-of-the-art avionics to maintain efficient operations throughout the entire arrival phase of flight. Flight deck Interval Management (FIM) operations are expected to use sophisticated airborne spacing capabilities to meet precise in-trail spacing from top-of-descent to touchdown. Recent human-in-the-loop simulations by the National Aeronautics and Space Administration have found that selection of the assigned spacing goal using the runway schedule can lead to premature interruptions of the FIM operation during periods of high traffic demand. This study compares three methods for calculating the assigned spacing goal for a FIM operation that is also subject to time-based metering constraints. The particular paradigms investigated include: one based upon the desired runway spacing interval, one based upon the desired meter fix spacing interval, and a composite method that combines both intervals. These three paradigms are evaluated for the primary arrival procedures to Phoenix Sky Harbor International Airport using the entire set of Rapid Update Cycle wind forecasts from 2011. For typical meter fix and runway spacing intervals, the runway- and meter fix-based paradigms exhibit moderate FIM interruption rates due to their inability to consider multiple metering constraints. The addition of larger separation buffers decreases the FIM interruption rate but also significantly reduces the achievable runway throughput. The composite paradigm causes no FIM interruptions, and maintains higher runway throughput more often than the other paradigms. A key implication of the results with respect to time-based metering is that FIM operations using a single assigned spacing goal will not allow reduction of the arrival schedule's excess spacing buffer. Alternative solutions for conducting the FIM operation in a manner more compatible with the arrival schedule are discussed in detail.

ATD-1↗

Langley Research Center Utility Risk from Future Climate Change

The successful operation of NASA Langley Research Center (LaRC) depends on services provided by several public utility companies. These include Newport News Waterworks, Dominion Virginia Power, Virginia Natural Gas and Hampton Roads Sanitation District. LaRC's plan to respond to future climate change should take into account how these companies plan to avoid interruption of services while minimizing cost to the customers. This report summarizes our findings from publicly available documents on how each company plans to respond. This will form the basis for future planning for the Center. Our preliminary findings show that flooding and severe storms could interrupt service from the Waterworks and Sanitation District but the potential is low due to plans in place to address climate change on their system. Virginia Natural Gas supplies energy to produce steam but most current steam comes from the Hampton trash burning plant, thus interruption risk is low. Dominion Virginia Power does not address climate change impacts on their system in their public reports. The potential interruption risk is considered to be medium. The Hampton Roads Sanitation District is projecting a major upgrade of their system to mitigate clean water inflow and infiltration. This will reduce infiltration and avoid overloading the pump stations and treatment plants.

De Young, Russell J.↗

Device for monitoring cell voltage

A device for monitoring a rechargeable battery having a number of electrically connected cells includes at least one current interruption switch for interrupting current flowing through at least one associated cell and a plurality of monitoring units for detecting cell voltage. Each monitoring unit is associated with a single cell and includes a reference voltage unit for producing a defined reference threshold voltage and a voltage comparison unit for comparing the reference threshold voltage with a partial cell voltage of the associated cell. The reference voltage unit is electrically supplied from the cell voltage of the associated cell. The voltage comparison unit is coupled to the at least one current interruption switch for interrupting the current of at least the current flowing through the associated cell, with a defined minimum difference between the reference threshold voltage and the partial cell voltage.

47 OTHER INSTRUMENTATION↗

Probabilistic Risk Assessment of Spent Fuel Pool Cooling System Failure Considering Safety and Security Initiating Events

In order to quantify the probable risk associated with a safety system, nuclear safety risk evaluation process is applied which is generally performed in three steps. The first step is to calculate the damage frequency of a critical system. This step is followed by the radioactive source term estimation due to the potential system damage. The final step is the assessment of off-site consequences. The safety risk formula is shown by Eq. (1). P{sub F} is the probability of safety system failure (the probability used describes a random, independent event), and C is the consequence value. R{sub SAF} = P{sub F} * C (1) The security risk associated with an attack on critical infrastructure and/or special nuclear materials theft is usually evaluated using three- term risk equation (probability of attack, probability of adversary success, and consequence). A security threat and the related initiating events are not considered in a pure safety risk analysis. The vulnerability of the physical protection system is performed independently even though the consequence resulting from a security initiating event can be similar to a safety related initiating event and thus gets double counted. The security risk can be calculated using Eq. (2) R{sub SEC} = P{sub A} * P{sub S} * C (2) PA is the probability of attack, P{sub S} is the probability of adversary success (P{sub S} = 1 - P{sub I} P{sub N}). P{sub I} being the probability of interruption which accounts for the probabilities of detection of all timely detection elements along an adversary path. PN being the probability of neutralization: the result of engagement of the response force with the adversaries after the interruption has occurred. C is the consequence magnitude from a successful attack. The two security probabilities do not describe random, independent events. As a result, because of the differences in the randomness and independence of the respective safety and security probabilities, the safety and the security risks are currently calculated separately. The consequence term in nuclear safety and security risk evaluation have the same definition. An effort is made here to study the effect on the overall risk by considering security initiating events along with the subsequent failure of the intermediate safety element. The target selected is a spent fuel storage pool for analyzing the public risk arising from the interplay between nuclear security and safety initiating events. EASI (Estimate of Adversary Sequence Interruption) model is used to calculate the probability of interruption related to a security system that leads to the calculation of the security initiating event frequency. Further progression of this initiating security event to a top event is analyzed using a Probabilistic Safety Assessment (PSA) tool, SAPHIRE (version 8) to obtain a joint pool damage frequency. For the progression of events leading to a top event, the failure of the intermediate safety elements is assumed to be external random events such as heavy load drop and fire events. The objectives of this study is to (1) determine the double accounting of frequency of failure, risk and allocated resources in the scenario of a non-random security initiating event leading to a safety random event chain (2) compare the damage frequency from pure security with the frequency of combined security-safety failure event and pure safety failure events. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cost-Benefit Analysis of Electricity Resilience Projects: State of the Art and Gap Analysis

Utilities and regulators must weigh the benefits of electricity resilience projects against their costs, which would be passed on to customers. Cost-benefit analysis (CBA) is an appropriate method for assessing this tradeoff. Here, in this paper we review the literature on CBA of electricity resilience projects and analyze gaps in the available methods and tools. The costs of resilience projects are typically straightforward to estimate but their benefits — particularly the avoided costs of power interruptions — are complex to quantify and monetize. A common perception among practitioners is that current CBA tools are not sufficiently mature to be adopted into real-world practice. We propose an electricity resilience CBA framework consisting of several elements: risks, physical impacts, power interruptions, economic impacts, and resilience projects. While methods for some elements are well-developed, there is a need for novel approaches to value avoided power interruptions, integrate multiple risks and benefit streams, and incorporate uncertainty.

Cost-benefit analysis↗

Reduction in Radiation-Induced Morbidity by Use of an Intercurrent Boost in the Management of Early-Stage Breast Cancer

Purpose: Electron or photon boost immediately following whole-breast irradiation performed after conservation surgery for early-stage breast cancer is the accepted standard of care. This regimen frequently results in Grade III dermatitis, causing discomfort or treatment interruption. Herein, we compare patients treated with whole-breast irradiation followed by boost compared with a cohort with a planned intercurrent radiation boost. Methods and Materials: The records of 650 consecutive breast cancer patients treated at Allegheny General Hospital (AGH) between 2000 and 2008 were reviewed. Selected for this study were 327 patients with T1 or T2 tumors treated with external beam radiotherapy postlumpectomy. One hundred and sixty-nine patients were treated by whole-breast radiotherapy (WBRT) followed by boost at completion. One hundred fifty-eight were treated with a planned intercurrent boost (delivered following 3,600 cGy WBRT). The mean whole breast radiation dose in the conventionally treated group was 5,032 cGy (range, 4500-5400 cGy), and the mean whole breast dose was 5,097 cGy (range, 4860-5040 cGy) in the group treated with a planned intercurrent boost. Results: The occurrence of Grade III dermatitis was significantly reduced in the WBRT/intercurrent boost group compared with the WBRT/boost group (0.6% vs. 8.9%), as was the incidence of treatment interruption (1.9% vs. 14.2%). With a median follow-up of 32 months and 27 months, respectively, no significant difference in local control was identified. Conclusions: Patients treated with intercurrent boost developed less Grade III dermatitis and unplanned treatment interruptions with similar local control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A micro-mechanism to explain the post-DRX grain growth at temperatures > 0.8Tm

Highlights: • Austenitic grain growth during working at temperature > 0.8T{sub m} is reduced by > 50%. • Growth mechanism during loading is distinct from growth in absence of loading. • During loading, growth occurs due to alignment of slip planes and grain merging. • Interruption of loading causes competitive growth and limits grain size. • Interrupted loading results in optimal microstructural and mechanical properties. - Abstract: A micro-mechanism responsible for the occurrence of post-dynamic recrystallization (DRX) grain growth during deformation at T > 0.8T{sub m} is described. Thermo-mechanical testing, microstructural characterization and diffraction studies reveal the link between slip and grain growth. If deformation is imparted in a single stage, grains grow by a cooperative growth process involving grain rotation and alignment of slip planes. This mechanism changes when deformation is interrupted and controlled intermediate soaking is performed before re-loading. A premeditated control of mechanism is shown to yield favourable microstructural and mechanical properties. A strategy to apply this control to industrial hot deformation is outlined.

36 MATERIALS SCIENCE↗

Transient inhibition of cell proliferation does not compromise self-renewal of mouse embryonic stem cells

Embryonic stem cells (ESCs) have unlimited capacity for self-renewal and can differentiate into various cell types when induced. They also have an unusual cell cycle control mechanism driven by constitutively active cyclin dependent kinases (Cdks). In mouse ESCs (mESCs). It is proposed that the rapid cell proliferation could be a necessary part of mechanisms that maintain mESC self-renewal and pluripotency, but this hypothesis is not in line with the finding in human ESCs (hESCs) that the length of the cell cycle is similar to differentiated cells. Therefore, whether rapid cell proliferation is essential for the maintenance of mESC state remains unclear. We provide insight into this uncertainty through chemical intervention of mESC cell cycle. We report here that inhibition of Cdks with olomoucine II can dramatically slow down cell proliferation of mESCs with concurrent down-regulation of cyclin A, B and E, and the activation of the Rb pathway. However, mESCs display can recover upon the removal of olomoucine II and are able to resume normal cell proliferation without losing self-renewal and pluripotency, as demonstrated by the expression of ESC markers, colony formation, embryoid body formation, and induced differentiation. We provide a mechanistic explanation for these observations by demonstrating that Oct4 and Nanog, two major transcription factors that play critical roles in the maintenance of ESC properties, are up-regulated via de novo protein synthesis when the cells are exposed to olomoucine II. Together, our data suggest that short-term inhibition of cell proliferation does not compromise the basic properties of mESCs. -- Highlights: Black-Right-Pointing-Pointer Inhibition of Cdks slows down mESCs proliferation. Black-Right-Pointing-Pointer mESCs display remarkable recovery capacity from short-term cell cycle interruption. Black-Right-Pointing-Pointer Short-term cell cycle interruption does not compromise mESC self-renewal. Black-Right-Pointing-Pointer Oct4 and Nanog are up-regulated via de novo synthesis by cell cycle interruption.

60 APPLIED LIFE SCIENCES↗

Design considerations of series type hybrid circuit breaker (S‐HCB)

Abstract The series‐type direct current (DC) hybrid circuit breaker (S‐HCB) concept was previously reported to offer better performance than solid‐state circuit breakers (SSCB) and hybrid circuit breakers (HCB). S‐HCB offers low conduction power loss like an HCB and ‐scale interruption time, which is even faster than an SSCB. It uses a pulse transformer to isolate the lower‐voltage high‐inductance power electronic circuit from the high‐voltage, low‐inductance main power loop. This paper provides analysis of the impact of the S‐HCB circuit components on the overall system performance and a scalable S‐HCB design guide for different DC system voltage and current ratings. In addition, system energy flow analysis is performed in the time domain to provide an understanding of how energy is delivered, dissipated, and released throughout the entire fault interruption process. The S‐HCB prototype was experimentally tested at 3 kV/30 A and 6 kV/150A with the results showing the interruption of the low fault current of 30 A and the high fault current of 150 A within 8 and maintaining the fault current at a near zero value for 300 to enable an arcless opening of a series mechanical switch. The key design challenges of S‐HCB at high voltage and high current ratings were discussed and possible solutions to mitigate those challenges were introduced.

Alashi, Mahmoud↗

Dielectric breakdown properties of hot SF{sub 6}/He mixtures predicted from basic data

Sulfur hexafluoride (SF{sub 6}) gas has a quite high global warming potential and hence it is required that applying any substitute for SF{sub 6} gas. Much interest in the use of a mixture of helium and SF{sub 6} as arc quenching medium was investigated indicating a higher recovery performance of arc interruption than that of pure SF{sub 6}. It is known that the electrical breakdown in a circuit breaker after arc interruption occurs in a hot gas environment, with a complicated species composition because of the occurrence of dissociation and other reactions. The likelihood of breakdown relies on the electron interactions with all these species. The critical reduced electric field strength (the field at which breakdown can occur, relative to the number density) of hot SF{sub 6}/He mixtures related to the dielectric recovery phase of a high voltage circuit breaker is calculated in the temperature range from 300 K to 3500 K. The critically reduced electric field strength of these mixtures was obtained by balancing electron generation and loss mechanisms. These were evaluated using the electron energy distribution function derived from the Boltzmann transport equation under the two-term approximation. Good agreement was found between calculations for pure hot SF{sub 6} and pure hot He and experimental results and previous calculations. The addition of He to SF{sub 6} was found to decrease the critical reduced electric field strength in the whole temperature range due to a lack of electron impact attachment process for helium regardless its high ionization potential. This indicates that not the behaviour of dielectric strength but possibly the higher energy dissipation capability caused mainly by light mass and high specific heat as well as thermal conductivity of atomic helium contributes most to a higher dielectric recovery performance of arc interruption for SF{sub 6}/He mixtures.

74 ATOMIC AND MOLECULAR PHYSICS↗

The resilience value of residential solar + storage systems in the continental U.S.

Abstract Behind the meter rooftop solar plus storage (PVESS) has the potential to benefit the hosting customers by providing affordability, environmental, and reliability and resilience value. Whereas the bill reduction and environmental benefits of PVESS are well studied, its monetary resilience benefits are less understood. The increasing trend of power interruptions driven by extreme weather events heightens the need to understand these benefits. This study leverages various publicly available datasets to perform a cost benefit analysis of adding to determine the resilience value of PVESS for a typical single family home in each county in the continental U.S. We find that PVESS is very effective to technically mitigate interruptions across the country. However, the monetary benefits in the base case only cover about 14% of battery costs, with no county exceeding 60%. This is somewhat expected, given that PVESS provide other monetary benefits that are not part of this analysis. Through sensitivities, we find that higher frequency of extreme weather events roughly triples the resilience value of PVESS and that higher values of lost load double the same metric. Our sensitivity analysis shows that the benefit cost ratio of PVESS for customers living in areas with higher-than-average frequency of long duration interruptions and value of lost load is already above one even without considering other value streams. We conclude with recommendations that regulators and utilities could implement to enable customers to calculate and capture the resilience value of PVESS more efficiently.

Baik, Sunhee↗

SCR-based Medium Voltage DC Solid-State Circuit Breaker

This paper describes a medium voltage solid-state circuit breaker (SSCB) based on SCR technology, featuring short fault-interruption time and a minimal turn-off auxiliary circuit. The SSCB design incorporates a specialized SCR and a commutation circuit designed with an objective to reduce the required SCR hold-off/turn-off time, tq, which primarily determines the fault interruption duration. To validate the design, simulation analysis is presented, and a 1.5 kV 300 A SSCB prototype has been built and tested. The results confirm the effectiveness of the proposed design philosophy demonstrating the SSCB's ability to interrupt a 200 A load current in less than 50 μs. The proposed SCR-based SSCB has been developed for DC applications but is equally applicable to AC applications.

Kandula, Prasad [ORNL] (ORCID:0000000174017284)↗