Search NASA⌕ Search

SEARCH · Search NASA

Results for “isolate pumping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

25 Years Of Environmental Remediation In The General Separations Area Of The Savannah River Site: Lessons Learned About What Worked And What Did Not Work In Soil And Groundwater Cleanup

The Savannah River Site (SRS) is owned and administered by the US Department of Energy (DOE). SRS covers an area of approximately 900 square kilometers. The General Separation Area (GSA) is located roughly in the center of the SRS and includes: radioactive material chemical separations facilities, radioactive waste tank farms, a variety of radioactive seepage basins, and the radioactive waste burial grounds. Radioactive wastes were disposed in the GSA from the mid-1950s through the mid-1990s. Radioactive operations at the F Canyon began in 1954; radioactive operations at H Canyon began in 1955. Waste water disposition to the F and H Seepage Basins began soon after operations started in the canyons. The Old Radioactive Waste Burial Ground (ORWBG) began operations in 1952 to manage solid waste that could be radioactive from all the site operations, and ceased receiving waste in 1972. The Mixed Waste Management Facility (MWMF) and Low Level Radioactive Waste Disposal Facility (LLRWDF) received radioactive solid waste from 1969 until 1995. Environmental legislation enacted in the 1970s, 1980s, and 1990s led to changes in waste management and environmental cleanup practices at SRS. The US Congress passed the Clean Air Act in 1970, and the Clean Water Act in 1972; the Resource Conservation and Recovery Act (RCRA) was enacted in 1976; the Comprehensive Environmental Response Compensation, and Liability Act (CERCLA) was enacted by Congress in 1980; the Federal Facilities Compliance Act (FFCA) was signed into law in 1992. Environmental remediation at the SRS essentially began with a 1987 Settlement Agreement between the SRS and the State of South Carolina (under the South Carolina Department of Health and Environmental Control - SCDHEC), which recognized linkage between many SRS waste management facilities and RCRA. The SRS manages several of the larger groundwater remedial activities under RCRA for facilities recognized early on as environmental problems. All subsequent environmental remediation projects tend to be managed under tri-party agreement (DOE, Environmental Protection Agency, and SCDHEC) through the Federal Facilities Agreement. During 25 years of environmental remediation SRS has stabilized and capped seepage basins, and consolidated and capped waste units and burial grounds in the GSA. Groundwater activities include: pump and treat systems in the groundwater, installation of deep subsurface barrier systems to manage groundwater flow, in situ chemical treatments in the groundwater, and captured contaminated groundwater discharges at the surface for management in a forest irrigation system. Over the last 25 years concentrations of contaminants in the aquifers beneath the GSA and in surface water streams in the GSA have dropped significantly. Closure of 65 waste sites and 4 RCRA facilities has been successfully accomplished. Wastes have been successfully isolated in place beneath a variety of caps and cover systems. Environmental clean-up has progressed to the stage where most of the work involves monitoring, optimization, and maintenance of existing remedial systems. Many lessons have been learned in the process. Geotextile covers outperform low permeability clay caps, especially with respect to the amount of repairs required to upkeep the drainage layers as the caps age. Passive, enhanced natural processes to address groundwater contamination are much more cost effective than pump and treat systems. SRS operated two very large pump and treat systems at the F and H Seepage Basins to attempt to limit the release of tritium to Fourmile Branch, a tributary of the Savannah River. The systems were designed to extract contaminated acidic groundwater, remove all contamination except tritium (not possible to remove the tritium from the water), and inject the tritiated groundwater up-gradient of the source area and the plume. The concept was to increase the travel time of the injected water for radioactive decay of the tritium. The two systems were found to be non-effective and potentially mobilizing more contamination. SRS invested approximately $50 million in construction and approximately $100 million in 6 years of operation. The H Seepage Basin pump and treat system was replaced by a series of subsurface barriers that alters the groundwater velocity; the F Seepage Basin pump and treat system was replaced by subsurface barriers forming a funnel and gate augmented by chemical treatment within the gates. These replacement systems are mostly passive and cost approximately $13 million to construct, and have reduced the tritium flux to Fourmile Branch, in these plumes, by over 70%. SRS manages non-acidic tritiated groundwater releases to Fourmile Branch from the southwest plume of the MWMF with a forest irrigation system. Tritiated water is captured with a sheetpile dam below the springs that caused releases to Fourmile Branch. Water from the irrigation pond is pumped to a filter plant prior to irrigation of approximately 26 hectares of mixed forest and developing pine plantation. SRS has almost achieved a 70% reduction in tritium flux to the Branch from this plume. The system cost approximately $5 million to construct with operation cost of approximately $500K per year. In conclusion, many lessons have been learned in 25 years of relatively aggressive remedial activities in the GSA. Geotextile covers outperform low permeability clay caps, especially with respect to the amount of repairs required to upkeep the drainage layers as the caps age. Passive, enhanced natural processes to address groundwater contamination are much more cost effective than pump and treat systems. In water management situations with non-accumulative contaminants (tritium, VOCs, etc.) irrigation in a forest setting can be very effective.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Time- and angle-resolved photoemission spectroscopy of solids in the extreme ultraviolet at 500 kHz repetition rate

Time- and angle-resolved photoemission spectroscopy (trARPES) employing a 500 kHz extreme-ultraviolet light source operating at 21.7 eV probe photon energy is reported. According to a high-power ytterbium laser, optical parametric chirped pulse amplification, and ultraviolet-driven high-harmonic generation, the light source produces an isolated high-harmonic with 110 meV bandwidth and a flux of more than 10 11 photons/s on the sample. Along with a state-of-the-art ARPES chamber, this table-top experiment allows high-repetition rate pump-probe experiments of electron dynamics in occupied and normally unoccupied (excited) states in the entire Brillouin zone and with a temporal system response function below 40 fs.

36 MATERIALS SCIENCE↗

Chopper system for time resolved experiments with synchrotron radiation

A chopper system for time resolved pump-probe experiments with x-ray beams from a synchrotron is described. The system has three parts: a water-cooled heatload chopper, a high-speed chopper, and a millisecond shutter. The chopper system, which is installed in beamline ID09B at the European Synchrotron Radiation Facility, provides short x-ray pulses for pump-probe experiments with ultrafast lasers. The chopper system can produce x-ray pulses as short as 200 ns in a continuous beam and repeat at frequencies from 0 to 3 kHz. For bunch filling patterns of the synchrotron with pulse separations greater than 100 ns, the high-speed chopper can isolate single 100 ps x-ray pulses that are used for the highest time resolution. A new rotor in the high-speed chopper is presented with a single pulse (100 ps) and long pulse (10 {mu}s) option. In white beam experiments, the heatload of the (noncooled) high-speed chopper is lowered by a heatload chopper, which absorbs 95% of the incoming power without affecting the pulses selected by the high speed chopper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Level Waste Mechanical Sludge Removal at the Savannah River Site - F Tank Farm Closure Project

The Savannah River Site F-Tank Farm Closure project has successfully performed Mechanical Sludge Removal (MSR) using the Waste on Wheels (WOW) system for the first time within one of its storage tanks. The WOW system is designed to be relatively mobile with the ability for many components to be redeployed to multiple waste tanks. It is primarily comprised of Submersible Mixer Pumps (SMPs), Submersible Transfer Pumps (STPs), and a mobile control room with a control panel and variable speed drives. In addition, the project is currently preparing another waste tank for MSR utilizing lessons learned from this previous operational activity. These tanks, designated as Tank 6 and Tank 5 respectively, are Type I waste tanks located in F-Tank Farm (FTF) with a capacity of 2,840 cubic meters (750,000 gallons) each. The construction of these tanks was completed in 1953, and they were placed into waste storage service in 1959. The tank's primary shell is 23 meters (75 feet) in diameter, and 7.5 meters (24.5 feet) in height. Type I tanks have 34 vertically oriented cooling coils and two horizontal cooling coil circuits along the tank floor. Both Tank 5 and Tank 6 received and stored F-PUREX waste during their operating service time before sludge removal was performed. DOE intends to remove from service and operationally close (fill with grout) Tank 5 and Tank 6 and other HLW tanks that do not meet current containment standards. Mechanical Sludge Removal, the first step in the tank closure process, will be followed by chemical cleaning. After obtaining regulatory approval, the tanks will be isolated and filled with grout for long-term stabilization. Mechanical Sludge Removal operations within Tank 6 removed approximately 75% of the original 95,000 liters (25,000 gallons). This sludge material was transferred in batches to an interim storage tank to prepare for vitrification. This operation consisted of eleven (11) Submersible Mixer Pump(s) mixing campaigns and multiple intra-area transfers utilizing STPs from July 2006 to August 2007. This operation and successful removal of sludge material meets requirement of approximately 19,000 to 28,000 liters (5,000 to 7,500 gallons) remaining prior to the Chemical Cleaning process. Removal of the last 35% of sludge was exponentially more difficult, as less and less sludge was available to mobilize and the lighter sludge particles were likely removed during the early mixing campaigns. The removal of the 72,000 liters (19,000 gallons) of sludge was challenging due to a number factors. One primary factor was the complex internal cooling coil array within Tank 6 that obstructed mixer discharge jets and impacted the Effective Cleaning Radius (ECR) of the Submersible Mixer Pumps. Minimal access locations into the tank through tank openings (risers) presented a challenge because the available options for equipment locations were very limited. Mechanical Sludge Removal activities using SMPs caused the sludge to migrate to areas of the tank that were outside of the SMP ECR. Various SMP operational strategies were used to address the challenge of moving sludge from remote areas of the tank to the transfer pump. This paper describes in detail the Mechanical Sludge Removal activities and mitigative solutions to cooling coil obstructions and other challenges. The performance of the WOW system and SMP operational strategies were evaluated and the resulting lessons learned are described for application to future Mechanical Sludge Removal operations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Electrical detection of liquid lithium leaks from pipe joints

A test stand for flowing liquid lithium is under construction at Princeton Plasma Physics Laboratory. As liquid lithium reacts with atmospheric gases and water, an electrical interlock system for detecting leaks and safely shutting down the apparatus has been constructed. A defense in depth strategy is taken to minimize the risk and impact of potential leaks. Each demountable joint is diagnosed with a cylindrical copper shell electrically isolated from the loop. By monitoring the electrical resistance between the pipe and the copper shell, a leak of (conductive) liquid lithium can be detected. Any resistance of less than 2 kΩ trips a relay, shutting off power to the heaters and pump. The system has been successfully tested with liquid gallium as a surrogate liquid metal. The circuit features an extensible number of channels to allow for future expansion of the loop. To ease diagnosis of faults, the status of each channel is shown with an analog front panel LED, and monitored and logged digitally by LabVIEW.

42 ENGINEERING↗

Parametric interaction and spatial collapse of beam-driven Langmuir waves in the solar wind

Observations are presented of the parametric decay and spatial collapse of Langmuir waves driven by an electron beam streaming into the solar wind from the Jovian bow shock. Long wavelength Langmuir waves upstream of the bow shock are effectively converted into short wavelength waves no longer in resonance with the beam. The conversion is shown to be the result of a nonlinear interaction involving the beam-driven pump, a sideband emission, and a low level of ion-acoustic turbulence. The beam-driven Langmuir wave emission breaks up into a complex sideband structure with both positive and negative Doppler shifts. In some cases, the sideband emission consists of isolated wave packets with very short duration bursts, which are very intense and are thought to consist of envelope solitons which have collapsed to spatial scales of only a few Debye lengths.

Gurnett, D. A.↗

Development of a He{sup 3}−He{sup 4} sub Kelvin active magnetic regenerative refrigerator (AMRR) with no moving parts

Current state of the art particle and photon detectors such as Transition Edge Sensors (TES) and Microwave Kinetic Inductance Detectors (MKID) use large arrays of sensors or detectors for space science missions. As the size of these space science detectors increases, future astrophysics missions will require sub-Kelvin cooling over larger areas. This leads to not only increased cooling power requirements, but also a requirement for distributed sub-Kelvin cooling. We propose an active Magnetic Regenerative Refrigerator (AMRR) that uses a Superfluid Magnetic Pump (SMP) to circulate liquid He{sup 3}−He{sup 4} through a magnetic regenerator to provide the necessary cooling at sub-Kelvin temperatures. Such system will be capable of distributing the cooling load to a relatively large array of objects. One advantage of using a fluid for heat transfer in such systems is to isolate components such as the superconducting magnets from detectors that are sensitive to magnetic fields. Another advantage of the proposed tandem AMRR is that it does not need Gas Gap Heat Switches (GGHS) to transfer heat during various stages of the magnetic cooling. Our proposed system consists of four superconducting magnets, one superleak, and three heat exchangers. It will operate continuously with no moving parts and it will be capable of providing the necessary cooling at sub-Kelvin temperatures for future space science applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical Time Reversal from Time-Dependent Epsilon-Near-Zero Media

Materials with a spatially uniform but temporally varying optical response have applications ranging from magnetic field-free optical isolators to fundamental studies of quantum field theories. However, these effects typically become relevant only for time variations oscillating at optical frequencies, thus presenting a significant hurdle that severely limits the realization of such conditions. Here we present a thin-film material with a permittivity that pulsates (uniformly in space) at optical frequencies and realizes a time-reversing medium of the form originally proposed by Pendry [Science 322, 71 (2008)]. We use an optically pumped, 500 nm thick film of epsilon-near-zero (ENZ) material based on Al-doped zinc oxide. An incident probe beam is both negatively refracted and time reversed through a reflected phase-conjugated beam. As a result of the high nonlinearity and the refractive index that is close to zero, the ENZ film leads to time reversed beams (simultaneous negative refraction and phase conjugation) with near-unit efficiency and greater-than-unit internal conversion efficiency. The ENZ platform therefore presents the time-reversal features required, e.g., for efficient subwavelength imaging, all-optical isolators and fundamental quantum field theory studies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental realization of nearly steady-state toroidal electron plasmas

Electron plasmas with densities of 5x10{sup 6} cm{sup -3} are trapped in the Lawrence Non-neutral Torus II (LNT II) for times exceeding 1 s. LNT II is a high aspect ratio (R{sub 0}/a > or approx.10) partially toroidal trap (270 deg. arc, B{sub 0}=670 G). The m=1 diocotron mode is launched and detected using isolated segments of a fully sectored conducting boundary and its frequency is used to determine the total trapped charge as a function of time. The observed confinement time ({approx_equal}3 s) approaches the theoretical limit ({approx_equal}6 s) set by the magnetic pumping transport mechanism of Crooks and O'Neil [Phys. Plasmas 3, 2533 (1996)]. We also present equilibrium modeling and numerical simulations of the toroidal m=1 mode constrained by experimental data. Future work includes the identification of the dominant transport mechanisms via confinement scaling experiments and measurement of the m=2 mode frequency and development of a strategy for making a transition to fully toroidal confinement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Miniature Heat Transport System for Nanosatellite Technology

The scientific understanding of key physical processes between the Sun and the Earth require simultaneous measurements from many vantage points in space. Nano-satellite technologies will enable a class of constellation missions for the NASA Space Science Sun-Earth Connections. This recent emphasis on the implementation of smaller satellites leads to a requirement for development of smaller subsystems in several areas. Key technologies under development include: advanced miniaturized chemical propulsion; miniaturized sensors; highly integrated, compact electronics; autonomous onboard and ground operations; miniatures low power tracking techniques for orbit determination; onboard RF communications capable of transmitting data to the ground from far distances; lightweight efficient solar array panels; lightweight, high output battery cells; lightweight yet strong composite materials for the nano-spacecraft and deployer-ship structures. These newer smaller systems may have higher power densities and higher thermal transport requirements than seen on previous small satellites. Furthermore, the small satellites may also have a requirement to maintain thermal control through extended earth shadows, possibly up to 8 hours long. Older thermal control technology, such as heaters, thermostats, and heat pipes, may not be sufficient to meet the requirements of these new systems. Conversely, a miniature two-phase heat transport system (Mini-HTS) such as a Capillary Pumped Loop (CPL) or Loop Heat Pipe (LBP) is a viable alternative. A Mini-HTS can provide fine temperature control, thermal diode action, and a highly efficient means of heat transfer. The Mini-HTS would have power capabilities in the range of tens of watts or less and provide thermal control over typical spacecraft ranges. The Mini-HTS would allow the internal portion of the spacecraft to be thermally isolated from the external radiator, thus protecting the internal components from extreme cold temperatures during an eclipse. The Mini-HTS would transport the beat from these components to a radiator during their operational modes, and it would be shutdown during non-operational or eclipse modes. Shutdown of the Mini-HTS would be accomplished with small heaters and has been successfully demonstrated on numerous occasions, both in the lab and on flight experiments. Efforts are now underway to miniaturize two-phase heat transport systems for the Nanosatellite project, with potential application to other small satellite programs. 'ne goal of this project is to design, build, and test miniature heat transport systems (MHTS) that would demonstrate the feasibility of a small Capillary Pumped Loop (CPL) or Loop Heat Pipe (LBP).

Douglas, Donya M,↗

Multi-phase model development to assess RCIC system capabilities under severe accident conditions

The Reactor Core Isolation Cooling (RCIC) System is a safety-related system that provides makeup water for core cooling of some Boiling Water Reactors (BWRs) with a Mark I containment. The RCIC System consists of a steam-driven Terry turbine that powers a centrifugal, multi-stage pump for providing water to the reactor pressure vessel. The Fukushima Dai-ichi accidents demonstrated that the RCIC System can play an important role under accident conditions in removing core decay heat. The unexpectedly sustained, good performance of the RCIC System in the Fukushima reactor demonstrates, firstly, that its capabilities are not well understood, and secondly, that the system has high potential for extended core cooling in accident scenarios. Better understanding and analysis tools would allow for more options to cope with a severe accident situation and to reduce the consequences. The objectives of this project were to develop physics-based models of the RCIC System, incorporate them into a multi-phase code and validate the models. This Final Technical Report details the progress throughout the project duration and the accomplishments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Method and apparatus to characterize ultrasonically reflective contrast agents

A method and apparatus for characterizing the time and frequency response of an ultrasonically reflective contrast agent is disclosed. An ultrasonically reflective contrast agent is injected, under constant pressure, into a fluid flowing through a pump flow circuit. The fluid and the ultrasonically reflective contrast agent are uniformly mixed in a mixing chamber, and the uniform mixture is passed through a contrast agent chamber. The contrast agent chamber is acoustically and axially interposed between an ultrasonic transducer chamber and an acoustic isolation chamber. A pulse of ultrasonic energy is transmitted into the contrast agent chamber from the ultrasonic transducer chamber. An echo waveform is received from the ultrasonically reflective contrast agent, and it is analyzed to determine the time and frequency response of the ultrasonically reflective contrast agent.

Pretlow, Robert A., III↗

Cleanroom Microbes Survive Drying, Vacuum, and Proton Irradiation

Introduction : The goal of planetary protection at NASA is to mitigate the risk of contaminating sensitive target bodies with biological life. While many cleaning procedures have been put in place to reduce bioburden on spacecraft, microbes are experts at evolving to survive harsh conditions. Specifically, the dry, low-nutrient environment of a cleanroom (commonly used for assembly of spacecraft) can represent an environment where extremophiles can survive. Methods : Scientists at NASA MSFC wished to gather a snapshot of the microbial population within a variety of cleanrooms on site. A study was undertaken to collect air, surface, and floor samples from clean-rooms and isolate unique morphologies. From this study, 95 isolates were collected and saved in a microbial library. About 86% of these were identified at least to a genus level. Following identification, 24 microbes were selected, based on a literature review, as potential extremophiles. These were grown in liquid cultures, diluted to a set optical density, washed with water, and then applied to a sterilized Kapton coupon. Droplets were allowed to dry overnight in a biosafety cabinet. Coupons were then installed in a pelletron and pumped down to high vacuum (~1E-6 Torr). Samples were then subjected 100 keV protons at a fluence of 2x10 15 p+/cm 2 up to 4x10 15 p+/cm 2 . Following exposure, samples were returned to the microbiology lab where they were pro-cessed by submerging in water, vortexing, and then plating either droplets or spread plates. Recovery data collected was qualitative with a ranking or +, minor, or – for growth. Some selected radiotolerant strains were sequenced using the Illumina sequencing platform. The resulting genomes were annotated with the Rapid Annotations using Subsystems Technology (RAST) server and analyzed for conserved and unique stress response relevant genomic signatures to identify clues related to specific tolerances. Results and Discussion : After five rounds of proton radiation, we narrowed our isolates to five, non-spore forming bacteria that demonstrated survival: Arthrobacter koreensis, Paenarthrobacter nitroguajacolicus, Mycetocola manganoxydans , and an Erwinia sp. Furthermore, we exposed these four microbes to 254 nm wavelength light at an intensity of 80 W/m 2 at a distance of ~18 cm for 10 minutes. Only A. koreensis demonstrated survival following UV exposure. Finally, we performed whole genome sequencing on the four strains to look for genetic markers of stress resistance. When we compared the genomes of the four strains, we found that genes coding for GGDEF and EAL domains with PAS/PAC sensors were only found in A. koreensis . These domains, modulated by PAS/PAC sensors, are hypothesized to facilitate survival under drying, desiccation, and proton irradiation. Drying and Desiccation : PAS domains sense hydration changes and modulate GGDEF and EAL domain activity to adjust c-di-GMP levels, enhancing resistance to desiccation. For instance, in Pseudomonas aeruginosa , the PAS domain of RbdA modulates activity under varying hydration conditions, affecting stress responses [1]. Proton Irradiation : Proton irradiation causes oxidative stress, leading to ROS generation. PAS domains detect this stress and modulate GGDEF and EAL domains to manage oxidative stress responses. In Shewanella , EAL domain proteins modulated by PAS sensors help bacteria adapt to extreme conditions [2]. These genes upregulate other stress response genes, protecting membrane function, protein stability, DNA repair, and antioxidant defenses. The modulation of c-di-GMP by PAS domains is crucial for bacterial adaptation to stress conditions, enabling dynamic physio-logical adjustments [3]. Understanding these mechanisms provides insights into bacterial stress responses and strategies for controlling bacterial growth [4]. Conclusions : These findings indicate that clean-rooms harbor extremophile microbes that may be able to survive conditions in deep space. Furthermore, while we identified certain stress-response genes that may be at least partly responsible for the phenotypes observed in this study, there are likely unidentified genes or characteristics about A. koreensis , and other bacteria, that may allow them to survive in harsh environments. Future studies will focus on identifying these unknown genes and characteristics, further elucidating the mechanisms of extremophile survival and potentially informing the development of new biotechnologies for space exploration and other extreme environments.

Chelsi Cassilly↗

Genome Sequence and Composition of a Tolyporphin-Producing Cyanobacterium-Microbial Community

The cyanobacterial culture HT-58-2 was originally described as a strain of Tolypothrix nodosa with the ability to produce tolyporphins, which comprise a family of distinct tetrapyrrole macrocycles with reported efflux pump inhibition properties. Upon reviving the culture from what was thought to be a nonextant collection, studies of culture conditions, strain characterization, phylogeny, and genomics have been undertaken. Here, HT-58-2 was shown by 16S rRNA analysis to closely align with Brasilonema strains and not with Tolypothrix isolates. Light, fluorescence, and scanning electron microscopy revealed cyanobacterium filaments that are decorated with attached bacteria and associated with free bacteria. Metagenomic surveys of HT-58-2 cultures revealed a diversity of bacteria dominated by Erythrobacteraceae , 97% of which are Porphyrobacter species. A dimethyl sulfoxide washing procedure was found to yield enriched cyanobacterial DNA (presumably by removing community bacteria) and sequence data sufficient for genome assembly. The finished, closed HT-58-2Cyano genome consists of 7.85 Mbp (42.6% G+C) and contains 6,581 genes. All genes for biosynthesis of tetrapyrroles (e.g., heme, chlorophyll a, and phycocyanobilin) and almost all for cobalamin were identified dispersed throughout the chromosome. Among the 6,177 protein-encoding genes, coding sequences (CDSs) for all but two of the eight enzymes for conversion of glutamic acid to protoporphyrinogen IX also were found within one major gene cluster. The cluster also includes 10 putative genes (and one hypothetical gene) encoding proteins with domains for a glycosyltransferase, two cytochrome P450 enzymes, and a flavin adenine dinucleotide (FAD)-binding protein. The composition of the gene cluster suggests a possible role in tolyporphin biosynthesis.

59 BASIC BIOLOGICAL SCIENCES↗

Optical testing cryogenic thermal vacuum facility

The construction of a turnkey cryogenic vacuum test facility was recently completed. The facility will be used to measure and record the surface profile of large diameter and 540 kg optics under simulated space conditions. The vacuum test chamber is a vertical stainless steel cylinder with a 3.5 diameter and a 7 m tangent length. The chamber was designed to maximize optical testing quality by minimizing the vibrations between the laser interferometer and the test specimen. This was accomplished by designing the chamber for a high natural frequency and vibration isolating the chamber. An optical test specimen is mounted on a movable presentation stage. During thermal vacuum testing, the specimen may be positioned to + or - 0.00025 cm accuracy with a fine adjustment mechanism. The chamber is evacuated by a close coupled Roots-type blower and rotary vane pump package and two cryopumps. The chamber is equipped with an optically dense gaseous nitrogen cooled thermal shroud. The thermal shroud is used to cool or warm the optical test specimen at a controlled rate. A control system is provided to automatically evacuate the chamber and cooldown the test specimen to the selected control temperature.

Dohogne, Patrick W.↗

Role of O2 in regulating tissue respiration in dog muscle working in situ

This study was designed to investigate the role of tissue oxygenation in some of the factors that are thought to regulate muscle respiration and metabolism. Tissue oxygenation was altered by reductions in O2 delivery (muscle blood flow x arterial O2 content), induced by decreases in arterial PO2 (PaO2). O2 uptake (VO2) was measured in isolated in situ canine gastrocnemius at rest and while working at two stimulation intensities (isometric tetanic contractions at 0.5 and 1 contractions/s) on three separate occasions, with only the level of PaO2 (78, 30, and 21 Torr) being different for each occasion. Muscle blood flow was held constant (pump perfusion) at each work intensity for the three different levels of PaO2. Muscle biopsies were obtained at the end of each rest and work period. Muscle VO2 was significantly less (P less than 0.05) at both stimulation intensities for the hypoxemic conditions, whereas [ATP] was reduced only during the highest work intensity during both hypoxemic conditions (31% reduction at 21 Torr PaO2 and 17% at 30 Torr). For each level of PaO2, the relationships between the changes that occurred in VO2 and levels of phosphocreatine, ADP, and ATP/ADP.P(i) as the stimulation intensity was increased were significantly correlated; however, the slopes and intercepts of these lines were significantly different for each PaO2. Thus a greater change in any of the proposed regulators of tissue respiration (e.g., phosphocreatine, ADP) was required to achieve a given VO2 as PaO2 was decreased.(ABSTRACT TRUNCATED AT 250 WORDS).

NASA Discipline Musculoskeletal↗

South Asian Monsoon Response to Regional Aerosol Emission Reductions: Insights From RAMIP

Anthropogenic aerosol and associated precursor gas emissions are already declining in many regions and are likely to decline significantly by 2050, with major implications for regional climate. Unlike greenhouse gases, aerosol impacts are spatially heterogeneous and can influence climate both near emission sources and through remote teleconnections. This is particularly important for the South Asian monsoon system, where both local and remote aerosol changes can significantly affect precipitation patterns. Using simulations from the Regional Aerosol Model Intercomparison Project, we examine how local and remote aerosol emission reductions influence South Asian climate across both pre-monsoon and monsoon seasons, including weakening of the elevated heat pump (EHP) mechanism during pre-monsoon months. Our analysis employs 10-member ensembles from 10 CMIP6-era models to compare three experiments with global, South Asian, and East Asian aerosol reductions relative to a high-emission baseline (SSP3-7.0). This experimental design allows us to isolate and quantify the distinct impacts of regional emission changes. Results reveal that global aerosol reductions produce a larger all-India precipitation increase (+0.28 mm day −1 ) than South Asian reductions alone (+0.19 mm day −1 ), with the strongest regional responses over the northern Bay of Bengal, the Western Ghats and Indo-Gangetic Plains. East Asian reductions show uncertain but modest precipitation reductions of 0.2-0.6 mm day −1 over parts of west-central and eastern Indian regions. Pre-monsoon carbonaceous aerosol reductions systematically weaken the EHP, cooling the mid-troposphere over the Himalayan foothills by up to 0.4 K and producing localised anomalous descent that opposes the climatological pre-monsoon ascent. Substantial inter-model diversity exists in the spatial patterns and magnitudes of these responses, highlighting key uncertainties in aerosol–monsoon interactions. The South Asian precipitation response is driven by enhanced land–sea thermal contrast, while the pre-monsoon EHP weakening is attributable exclusively to local South Asian carbonaceous aerosol forcing rather than remote teleconnections. These findings have direct implications for air quality and climate adaptation planning across South Asia as regional aerosol emissions diverge under different development pathways.

cmip6↗