Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser absorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Foil backlighter development at the OMEGA laser facility for extended x-ray absorption fine structure experiments

Extended x-ray absorption fine structure (EXAFS) measurements require a bright and continuous x-ray source and a detection system with high spectral resolution to capture the modulations of the absorption coefficient above the material absorption edge. When performing EXAFS measurements under laser-driven dynamic compression, it is hence critical to optimize the backlighter x-ray emission. In this study, a series of experiments has been conducted at the OMEGA laser facility to characterize titanium (Z = 22), iron (Z = 26), germanium (Z = 32), molybdenum (Z = 42), silver (Z = 47), and gold (Z = 79) foil backlighters irradiated with 3 kJ–12 kJ of laser energy. The spectra have been recorded using a dual crystal spectrometer (DCS), a two-channel transmission spectrometer covering 11 keV–45 keV and 19 keV–90 keV energy bands. The DCS has been calibrated so that the spectral intensities can be compared between different campaigns.

47 OTHER INSTRUMENTATION↗

Experimental demonstration of the reduced expansion of a laser-heated surface using a low density foam layer, pertaining to advanced hohlraum designs with less wall-motion

The ablative expansion of laser-heated materials is important for determining how hohlraum cavities can be utilized for inertial confinement fusion. The utility of a low-density foam layer to reduce the density of the expanding heated hohlraum wall is demonstrated here in a series of experiments on the National Ignition Facility. X-ray radiography measurements of the expanding foam-lined Au wall in low aspect-ratio cylindrical geometry are used to compare the impact of Au-doped CH and Ta 2 O 5 foams between 10 and 40 mg/cc on the wall expansion. HYDRA Simulations are used to estimate the x-ray transmission at the 1/4 nc surface, which is important in understanding the absorption of laser light by the plasma. These demonstrate for the first time that a foam layer reduces the expansion of a hohlraum-like target and illustrate that the interplay between the expanding foam plasma and the shock reflected by the hohlraum wall is critical in optimizing foam-liner parameters to achieve the maximum time for a symmetric drive on a capsule.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Control of low-mode drive asymmetry in an efficient long-pulse low gas-fill density Hohlraum

Laser-driven Hohlraums filled with gas at lower densities (<0.6 mg/cc) have higher efficiency compared to original ≥ 0.96 mg/cc fill because of reduced backscatter losses [Hall et al., Phys. Plasmas 24, 052706 (2017)]. However, using low-density filled Hohlraums with longer drive required for lower adiabat implosions, and hence potentially higher inertial confinement fusion gain designs, has been challenging since the Hohlraum wall blow-off is less tamped, thus altering the laser beam absorption regions and drive symmetry. A series of NIF experiments using optimized pulse shaping, beam pointing, and temporal phasing have demonstrated, through imaging of the Hohlraum and capsule dynamics, that a symmetric implosion using a 14-ns low-adiabat drive pulse {2× longer than high-density-carbon ablator designs using low gas-fill density Hohlraums [Divol et al., Phys. Plasmas 24, 056309 (2017)]} is possible in a low backscatter loss 0.45 mg/cc He-filled Hohlraum. The ingress of the Hohlraum walls was mitigated by revisiting the adiabat-shaped design [Clark et al., Phys. Plasmas 21, 112705 (2014)] that uses a low-power (1 TW) trough that delays the wall expansion. Low-mode P 2 and P 4 drive asymmetry swings caused by the drift of the laser spots were essentially zeroed out by employing temporal beam phasing between cones of beams [Turner et al., Phys. Plasmas 7, 333 (2000)]. So the results also indicate an improved coupling efficiency of ~30% compared to an earlier design using higher density filled Hohlraums and pave the way for revisiting low-adiabat, high convergence drives using CH ablators.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Method for Rapid and Precise Triple Oxygen Isotope Measurements via High-Temperature Conversion to CO Followed by Nickel-Catalyzed CO to CO 2 Conversion and Laser Spectroscopy

Triple oxygen isotopic compositions ( 16 O, 17 O, 18 O) have conventionally been measured via isotope ratio mass spectrometry using O 2 as an analyte. Conversion of sample oxygen to O 2 typically utilizes fluorination chemistry or catalytic equilibration between CO 2 and O 2 . Recently, laser spectroscopy has become a viable alternative for triple oxygen isotope (Δ' 17 O) measurements due to its ease and rapid throughput. Laser spectrometers are currently available for Δ' 17 O analysis of either H 2 O or CO 2 as the analyte gas. So far, these instruments have been used to measure Δ' 17 O of water, carbonate (CO 2 liberated by acid digestion), and atmospheric CO 2 samples. Here, we present a new method for high-precision Δ' 17 O analysis of CO 2 via tunable infrared laser direct absorption spectroscopy that is compatible with a wider range of geochemically important materials. This approach involves converting sample oxygen to CO 2 in two steps. First, the sample oxygen is liberated and reduced to CO by high-temperature conversion at 1450 °C in the presence of excess elemental carbon. Then, CO is catalytically converted to CO 2 over hot nickel at 350 °C. The conversion process is rapid (10 to 30 min) and quantitative. Spectroscopic Δ' 17 O analysis of the resulting CO 2 takes approximately 45 min. By measuring several oxygen isotope standards, we demonstrate that the method is precise (1σ = 12 per meg for procedural replicates) and accurate (within 11 per meg of previously reported values). The method can be applied to most pyrolytic materials where quantitative oxygen conversion is attainable, such as sulfate, phosphate, nitrate, and oxide minerals, water, and organic molecules.

Ellis, Nicholas M. [University of California, Berk↗

Unraveling Nonequilibrium Generation of Atomic Nitrogen and Hydrogen in Plasma-Aided Ammonia Synthesis

In this study, nonequilibrium generation of atomic nitrogen and hydrogen governing ammonia production both in the gas phase and on the catalyst surface is critical to plasma-aided ammonia synthesis. Here, this work studies the nonequilibrium generation of atomic nitrogen and hydrogen with a focus on the kinetic role of vibrational energy transfer of hydrogen molecules in plasma-aided ammonia synthesis. By combining two-photon absorption laser-induced fluorescence measurements and plasma kinetic modeling, we found that plasma not only generates ammonia but also produces critical H, N, and NH radicals via both electron impact and vibrational energy transfer excitations. The vibrational energy transfer from the excited hydrogen H 2 (v = 1) to higher vibrational levels H 2 (v = 2–3) via the V–V exchange (H 2 (v)–H 2 (v)) and V–V' exchange (N 2 (v)–H 2 (v)) significantly enhances the H and NH production and then promotes the coupling between N and NH for ammonia synthesis both in the gas phase and on the catalyst surface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Argon metastable density and temperature of a 43 GHz microplasma

Argon (1s 5 ) metastable density and translational gas temperature are experimentally measured using laser diode absorption spectroscopy within a 43 GHz microplasma. The plasma is initiated and sustained within a photonic crystal constructed from a rectangular array of alumina rods, each 1 mm in diameter. This configuration generates stable microplasma from 10 to 600 Torr using millimeter wave power from 100 to 1200 mW. The metastable density is in the order of 10 18 m –3 at low pressure. However, Ar(1s 5 ) density decreases to undetectable levels with increasing pressure and wave power. The gas temperature is extracted from the Lorentzian line shape of the absorption profile at 811.53 nm. The gas temperature increases from approximately 400 K at low pressure to 2000 K at 320 Torr (427 mbar, 4.27 × 10 4 Pa). Furthermore, these data are compared with previous results and suggest that the microplasma has a dense core of electrons that depletes the metastable density at high gas pressure and wave power.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Charged particle transport coefficient challenges in high energy density plasmas

High energy density physics (HEDP) and inertial confinement fusion (ICF) research typically relies on computational modeling using radiation-hydrodynamics codes in order to design experiments and understand their results. These tools, in turn, rely on numerous charged particle transport and relaxation coefficients to account for laser energy absorption, viscous dissipation, mass transport, thermal conduction, electrical conduction, non-local ion (including charged fusion product) transport, non-local electron transport, magnetohydrodynamics, multi-ion-species thermalization, and electron-ion equilibration. In many situations, these coefficients couple to other physics, such as imposed or self-generated magnetic fields. Furthermore, how these coefficients combine are sensitive to plasma conditions as well as how materials are distributed within a computational cell. Uncertainties in these coefficients and how they couple to other physics could explain many of the discrepancies between simulation predictions and experimental results that persist in even the most detailed calculations. This paper reviews the challenges faced by radiation-hydrodynamics in predicting the results of HEDP and ICF experiments with regard to these and other physics models typically included in simulation codes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pump-depletion dynamics and saturation of stimulated Brillouin scattering in shock ignition relevant experiments

As an alternative inertial confinement fusion scheme, shock ignition requires a strong converging shock driven by a high-intensity laser pulse to ignite a pre-compressed fusion capsule. Understanding nonlinear laser-plasma instabilities is crucial to assess and improve the laser-shock energy coupling. Recent experiments conducted on the OMEGA EP laser facility have for the first time demonstrated that such instabilities can 100% deplete the first 0.5 ns of the high-intensity laser. Here, analyses of the observed laser-generated blast wave suggest that this pump-depletion starts at 0.02 critical density and progresses to 0.1-0.2 critical density, which is also confirmed by the time-resolved stimulated Raman backscattering spectra. The pump-depletion dynamics can be explained by the breaking of ion-acoustic waves in stimulated Brillouin scattering. Such pump-depletion would inhibit the collisional laser energy absorption but may benefit the generation of hot electrons with moderate temperatures for electron shock ignition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pulse-burst spontaneous Raman thermometry of unsteady wave phenomena in a shock tube

A high-speed temperature diagnostic based on spontaneous Raman scattering (SRS) was demonstrated using a pulse-burst laser. The technique was first benchmarked in near-adiabatic H 2 -air flames at a data-acquisition rate of 5 kHz using an integrated pulse energy of 1.0 J per realization. Both the measurement precision and accuracy in the flame were within 3% of adiabatic predictions. Furthermore, this technique was then evaluated in a challenging free-piston shock tube environment operated at a shock Mach number of 3.5. SRS thermometry resolved the temperature in post-incident and post-reflected shock flows at a repetition rate of 3 kHz and clearly showed cooling associated with driver expansion waves. Collectively, this Letter represents a major advancement for SRS in impulsive facilities, which had previously been limited to steady state regions or single-shot acquisition.

47 OTHER INSTRUMENTATION↗

Measurement of Magnetic Field using Doppler-Free Saturation Spectroscopy (DFSS) in C-2W FRC Plasma

The Cooperative Research and Development Agreement (CRADA) between Oak Ridge National Laboratory (ORNL) and TAE Technologies (TAE) focused on implementing an existing mobile Doppler-free saturation spectroscopy (DFSS) diagnostic to determine the direction of the equilibrium magnetic field within TAE’s C-2W field-reversed configuration (FRC) fusion device. Non-perturbative measurements of magnetic fields in the core of FRCs can provide critical information needed to constrain equilibrium models and for the continued advancement of the fusion research program at TAE. DFSS is a well-established, laser-based absorption spectroscopy technique used to suppress inhomogeneous (Doppler) broadening and reveal the Zeeman fine structure of the target emission lines. The collaboration involved the use of ORNL’s recently constructed mobile DFSS diagnostic. The DFSS diagnostic was shipped and installed on C- 2W in February 2023. TAE’s expertise was used to design and construct the mechanic support structures required to mount the optical hardware on C-2W. Additionally TAE provide critical input to minimize the noise imposed on the DFSS signal by vibrations of the mechanic support structure during operations. DFSS data was obtained for over 500 C-2W shots and will continue until the expiration of this CRADA on September 30 th 2023. Over the course of this work, significant progress was made to maximize the signal to noise (SNR) ratio. Analysis of recently acquired data is on-going, however, initial indications are highly suggestive that a DFSS signal above background has been successfully acquired in C-2W.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Relativistically Induced Transparency in Plasma (Final Research Report)

The major goal of this project was to study the process of relativistic transparency in plasmas. This process occurs when a very high intensity laser pulse interacts with a plasma. The electric field of the laser oscillates the electron speeds approaching the speed of light, increasing the effective mass of the electrons by the time-averaged Lorentz factor <γ>. The increase in the effective mass alters the critical density, the density at which the plasma becomes opaque to the electromagnetic wave of the laser. This project used experiments and particle-in-cell simulations to study this process in ultra-thin foil interactions. Experiments were performed through the LaserNetUS program on the Ohio State University laser system Scarlet. The transmitted and reflected light was studied as a function of the target thickness, the near-field profiles, the total energy and pulse duration were measured. Particle-in-cell simulations, using the OSIRIS code were used to model the interaction and better understand the dynamics. The results of both show current relativistic transparency theory is insufficient to predict the results, this is likely because the theories do not account for the laser energy absorption into the target and global plasma fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interactions of a Microdischarge with a Premixed Flame (Final Technical Report)

In this project we introduced an experimental platform that facilitates the study of the two-way interaction of plasma and flame, and the exploration of the impact of the spatial location of the discharge on its kinetics, in a controlled environment. The experimental platform is a mesoscale CH4/air premixed flame burner that also acts as a dielectric barrier discharge (DBD) operated by nanosecond pulsed voltage. A unique feature of this setup is that the DBD utilizes transparent electrodes, made of Indium Tin Oxide (ITO), to unlock optical access along the line-of-sight parallel to the dominant electric field. This platform is suitable to study both the forward problem (impact of plasma-on-flame), which manifests itself as a modified flame speed as well as flame wrinkling; and the backward problem (impact of flame-on-plasma), which includes plasma regime transitions, between microdischarges and uniform modes, driven by the flame passage. Prior work at MIT has focused on electrical measurements and direct imaging studies of the plasma-flame interaction through the ITO electrode. This project, which was awarded experimental runtime at the Low-temperature Plasma Research Facility (PRF) at Sandia National Laboratories, quantifies the flame-plasma interaction through temporally resolved measurement of key radicals (oxygen atom, O) produced by the nanosecond repetitively pused discharge (NRPD) in an individual microdischarge, using two-photon absorption laser-induced fluorescence (TALIF).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Standoff Infrared Measurements of Chemical Plume Dynamics in Complex Terrain Using a Combination of Active Swept-ECQCL Laser Spectroscopy with Passive Hyperspectral Imaging

Chemical plume detection and modeling in complex terrain present numerous challenges. We present experimental results from outdoor releases of two chemical tracers (sulfur hexafluoride and Freon-152a) from different locations in mountainous terrain. Chemical plumes were detected using two standoff instruments collocated at a distance of 1.5 km from the plume releases. A passive long-wave infrared hyperspectral imaging system was used to show time- and space-resolved plume transport in regions near the source. An active infrared swept-wavelength external cavity quantum cascade laser system was used in a standoff configuration to measure quantitative chemical column densities with high time resolution and high sensitivity along a single measurement path. Both instruments provided chemical-specific detection of the plumes and provided complementary information over different temporal and spatial scales. The results show highly variable plume propagation dynamics near the release points, strongly dependent on the local topography and winds. Effects of plume stagnation, plume splitting, and plume mixing were all observed and are explained based on local topographic and wind conditions. Measured plume column densities at distances ~100 m from the release point show temporal fluctuations over ~1 s time scales and spatial variations over ~1 m length scales. The results highlight the need for high-speed and spatially resolved measurement techniques to provide validation data at the relevant spatial and temporal scales required for high-fidelity terrain-aware microscale plume propagation models.

47 OTHER INSTRUMENTATION↗

Versatile soil gas concentration and isotope monitoring: optimization and integration of novel soil gas probes with online trace gas detection

Abstract. Gas concentrations and isotopic signatures can unveil microbial metabolisms and their responses to environmental changes in soil. Currently, few methods measure in situ soil trace gases such as the products of nitrogen and carbon cycling or volatile organic compounds (VOCs) that constrain microbial biochemical processes like nitrification, methanogenesis, respiration, and microbial communication. Versatile trace gas sampling systems that integrate soil probes with sensitive trace gas analyzers could fill this gap with in situ soil gas measurements that resolve spatial (centimeters) and temporal (minutes) patterns. We developed a system that integrates new porous and hydrophobic sintered polytetrafluoroethylene (sPTFE) diffusive soil gas probes that non-disruptively collect soil gas samples with a transfer system to direct gas from multiple probes to one or more central gas analyzer(s) such as laser and mass spectrometers. Here, we demonstrate the feasibility and versatility of this automated multiprobe system for soil gas measurements of isotopic ratios of nitrous oxide (δ18O, δ15N, and the 15N site preference of N2O), methane, carbon dioxide (δ13C), and VOCs. First, we used an inert silica matrix to challenge probe measurements under controlled gas conditions. By changing and controlling system flow parameters, including the probe flow rate, we optimized recovery of representative soil gas samples while reducing sampling artifacts on subsurface concentrations. Second, we used this system to provide a real-time window into the impact of environmental manipulation of irrigation and soil redox conditions on in situ N2O and VOC concentrations. Moreover, to reveal the dynamics in the stable isotope ratios of N2O (i.e., 14N14N16O, 14N15N16O, 15N14N16O, and 14N14N18O), we developed a new high-precision laser spectrometer with a reduced sample volume demand. Our integrated system – a tunable infrared laser direct absorption spectrometry (TILDAS) in parallel with Vocus proton transfer reaction mass spectrometry (PTR-MS), in line with sPTFE soil gas probes – successfully quantified isotopic signatures for N2O, CO2, and VOCs in real time as responses to changes in the dry–wetting cycle and redox conditions. Broadening the collection of trace gases that can be monitored in the subsurface is critical for monitoring biogeochemical cycles, ecosystem health, and management practices at scales relevant to the soil system.

54 ENVIRONMENTAL SCIENCES↗

Comparison of atomized mass and crater volume in laser ablation

The extent and dynamics of laser ablation are typically studied using crater imaging or by invoking the relationship between atomic emission and the mass removed. The former is a static view of a dynamic process and requires the accumulation of multiple shots in one location. The latter is complex and not absolute without calibration of the optical system with a standard of spectral radiance. We measure the mass of the atomized plume by laser atomic-absorption spectroscopy at 2 µs without external mass calibration; mass uncertainty in laser-ablation atomic absorption spectroscopy (LA-AAS) results from uncertainties in line area fitting, tabulated oscillator strengths, and partition functions as well as a <10% underrepresentation of the mass due to treating the plasma as a single thermodynamic equilibrium. The LA-AAS-measured mass pertains to the atoms in the probed charge states and does not include condensed or molecular species. The ablation efficiency at 300 mbar of helium varies significantly between the two focusing conditions used. A comparison of crater-derived masses and LA-AAS masses suggests that more defocused ablation may result in significant redeposition of material in the crater, distorting the conclusions from drilling studies and crater imaging. More focused ablation conditions result in crater-derived masses that exceed those measured with LA-AAS and suggest melt expulsion or phase explosion.

Merten, Jonathan [Arkansas State University, Jones↗

Opto-thermal laser detonator

An opto-thermal laser detonator uses resonantly absorptive tuned nano-material associated with secondary explosives for optical absorption and initiation by an integral laser diode. The opto-thermal laser detonator includes main explosive material; resonantly absorptive tuned nano-material; secondary explosive material, wherein the resonantly absorptive tuned nano-material and the secondary explosive material are associated to form associated material made of the resonantly absorptive tuned nano-material and the secondary explosive material; and a laser diode operatively connected to the associated material, wherein the laser diode initiates the associated material which in turn initiates the main explosive material.

Wilkins, Paul R.↗