Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser ion source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Improved high-precision mass measurements of mid-shell neon isotopes

New mass values measured with the TITAN MR-TOF-MS are reported for the short-lived isotopes 24-26 Ne, produced at TRIUMF's ISAC facility using a uranium carbide target and cold FEBIAD ion source. A least-squares adjustment within the framework of the Atomic Mass Evaluation was performed and the improved precision of the new mass values is highlighted. The improved mass accuracy in this N = 14mid-shell region can also point to the refinement in values of the charge radii. By reducing the mass uncertainty of isotopes, their contribution of the mass shift uncertainty in laser spectroscopy can be negated. The work is part of developments for reaching the N = 20 Island of Inversion, where high molecular contamination hinders mass measurements of the neon isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of mid-infrared solid state lasers for spaceborne lidar

Researchers investigated laser performance of Ho(3+):Tm(3+):Cr(3+):YAG crystals under both Cr:GSAG laser and flashlamp pumping. A flashlamp pumped Cr:GSAG laser was built to simulate high power quasi-CW laser diode pumping of a 2.1 micron holmium laser. The 2.1 micron output laser energy exceeded more than 14 mJ, the highest value reported to date under laser pumping near 785 nm. This was obtained in a pulse length of nearly 650 microns from a 3 x 3 mm Ho:Tm:Cr:YAG rod by using the flashlamp-pumped Cr:GSAG laser as a pumping source at the diode laser wavelength, 785 microns. In addition, Ho:Tm:Cr:YAG crystals with various Tm(3+) concentrations have been evaluated for flashlamp-pumped normal mode and Q-switched 2.1 micron laser operations under a wide variety of experimental conditions in order to understand internal dynamic processes among the ions and to determine an optimum lasing condition. An increase of the laser slope efficiency was observed with the increase of the Tm(3+) concentration from 2.5 atomic percent to 4.5 atomic percent. The thermal dependence of the laser performance was also investigated. Q-switched laser output energies corresponding to nearly 100 percent of the normal-mode laser energies were obtained in a strong single spike of 200 ns pulse length by optimizing the opening time of a lithium niobate Q-switch.

Whitney, Donald A.↗

A High Intensity Spin-Polarized Electron Photogun to Drive a Polarized Positron Source

A photogun to generate a high-intensity, highly spin-polarized electron beam >90% with unprecedented charge lifetime in the kilocoulomb range is envisioned at JLab for a proposed Ce+BAF polarized positron beam source. The electron photogun is expected to provide a CW beam of >1 mA for a month without intervention. A limiting factor is ion-back bom-bardment on the strained-superlattice GaAs-photocathode which can be reduced by improving the photogun vacuum or biasing the anode. Additionally, increasing the laser spot size can help mitigate ion-induced damage. However, eventually the laser size becomes too large for the photogun electrode. An envisioned photogun design will incorporate larger electrodes to accommodate larger and off-center laser spot sizes. Compatible larger conical insulators which operate >300 kV for beam injection into a Beta~1 SRF booster are also necessary.

Hernandez Garcia, Carlos↗

EUV debris mitigation using magnetic nulls

Next generation EUV sources for photolithography use light produced by laser-produced plasmas (LPP) from ablated tin droplets. A major challenge for extending the lifetime of these devices is mitigating damage caused by deposition of tin debris on the sensitive collection mirror. Especially difficult to stop are high energy (up to 10 keV) highly charged tin ions created in the plasma. Existing solutions include the use of stopping gas, electric fields, and magnetic fields. One common configuration consists of a magnetic field perpendicular to the EUV emission direction, but such a system can result in ion populations that are trapped rather than removed. Here we investigate a previously unconsidered mitigation geometry consisting of a magnetic null by performing full-orbit integration of the ion trajectories in an EUV system with realistic dimensions and optimize the coil locations for the null configuration. The magnetic null prevents a fraction of ions from hitting the mirror comparable to that of the perpendicular field, but does not trap any ions due to the chaotic nature of ion trajectories that pass close to the null. This technology can potentially improve LPP-based EUV photolithography system efficiency and lifetime and may allow for a different, more efficient formulation of buffer gas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Requirements for laser radar detection of a barium ion cloud at five earth radii.

The requirements for a tuned laser radar capable of detecting and ranging a high altitude barium ion cloud release are discussed. A high energy pulsed dye laser tuned to the 455.4 nm Ba II resonance line is considered as the transmitter. Photon counting detection is employed and the resultant signal is integrated over a number of successive laser firings. The solar induced radiance of the cloud is the major background noise source. Detection and ranging may be achieved with signal-to-noise ratios of the order of unity using currently available equipment. This technique has the potential of improved resolution as compared to photographic measurements previously made.

Mumola, P. B.↗

Characterization of a mock up nuclear waste package using energy resolved MeV neutron analysis

Reliable radiographic methods for characterizing nuclear waste packages non-destructively (without the need to open containers) have the potential to significantly contribute to safe handling and future disposal options, particularly for legacy waste of unknown content. Due to required shielding of waste containers and the need to characterize materials consisting of light elements, X-ray methods are not suitable. Here, energy-resolved MeV neutron radiography is demonstrated as a first-of-its-kind application for non-destructive and remote examination of mock up nuclear waste packages from a safe position using time-of-flight techniques enabled by a novel event-mode imaging detector system. Energy-resolved neutron transmission spectra were measured spatially, permitting the detection of analogue materials to actual nuclear waste such as water, melamine, and ion exchange resin within a 2.54 cm wall thickness steel pipe. The results demonstrate the capability to locate the materials through this wall thickness by radiography and tomographic reconstruction, revealing detailed 3D distributions and structural anomalies. The method effectively detects residual water in ion exchange resin, highlighting its sensitivity to moisture content, a crucial parameter for nuclear waste characterization. Monte Carlo simulations are in agreement with the experimental findings, providing a pathway to simulate waste forms more difficult to tackle experimentally. This work paves the way to apply sub-nanosecond intense MeV neutron sources, such as laser-driven neutron sources under development, to nuclear waste characterization.

36 MATERIALS SCIENCE↗

Continuous-wave planar laser induced fluorescence with a fast camera

We present planar, laser induced fluorescence (PLIF) measurements of the velocity-resolved distribution function of ions in a plasma using a modulated, narrow linewidth, continuous-wave laser. Plasma emission is acquired with a high frame rate camera, and the laser light is spread into a thin sheet so that an entire plane of the plasma is imaged at each interrogation wavelength. Fourier analysis is conducted on each pixel of the images to separate the modulated fluorescent emission from the background light. Argon ion temperatures and bulk flow maps are reported in a helicon plasma source, and standard single-point LIF measurements provide validation of the PLIF measurement.

47 OTHER INSTRUMENTATION↗

Diffraction enhanced imaging utilizing a laser produced x-ray source

Image formation by Fresnel diffraction utilizes both absorption and phase-contrast to measure electron density profiles. The low spatial and spectral coherence requirements allow the technique to be performed with a laser-produced x-ray source coupled with a narrow slit. This makes it an excellent candidate for probing interfaces between materials at extreme conditions, which can only be generated at large-scale laser or pulsed power facilities. Here, we present the results from a proof-of-principle experiment demonstrating an effective ~2 μm laser-generated source at the OMEGA Laser Facility. This was achieved using slits of 1 × 30 μm 2 and 2 × 40 μm 2 geometry, which were milled into 30 μm thick Ta plates. Combining these slits with a vanadium He-like 5.2 keV source created a 1D imaging system capable of micrometer-scale resolution. The principal obstacles to achieving an effective 1 μm source are the slit tilt and taper—where the use of a tapered slit is necessary to increase the alignment tolerance. We demonstrate an effective source size by imaging a 2 ± 0.2 μm radius tungsten wire.

3D printing↗

The response of thermally and optically stimulated luminescence from Al2O3:C to high-energy heavy charged particles

The thermoluminescence (TL) and optically stimulated luminescence (OSL) response of Al2O3 dosimeters to high-energy heavy charged particles (HCP) has been studied using the heavy ion medical accelerator at Chiba, Japan. The samples were Al2O3 single-crystal chips, of the type usually known as TLD-500, and Luxel(TM) dosimeters (Al2O3:C powder in plastic) from Landauer Inc. The samples were exposed to 4He (150 MeV/u), 12C (400 MeV/u), 28Si (490 MeV/us) and 56Fe (500 MeV/u) ions, with linear energy transfer values covering the range from 2.26 to 189 keV/micrometers in water and doses from 1 to 100 mGy (to water). A 90Sr/90Y beta source, calibrated against a 60Co secondary standard, was used for calibration purposes. For OSL, we used both continuous-wave OSL measurements (CW-OSL, using green light stimulation at 525 nm) and pulsed OSL measurements (POSL, using 532 nm stimulation from a Nd:YAG Q-switched laser). The efficiencies (eta HCP, gamma) of the different HCPs at producing OSL or TL were observed to depend not only upon the linear energy transfer (LET) of the HCP, but also upon the sample type (single crystal chip or Luxel(TM)) and the luminescence method used to define the signal--i.e. TL, CW-OSL initial intensity, CW-OSL total area, or POSL. Observed changes in shape of the decay curve lead to potential methods for extracting LET information of unknown radiation fields. A discussion of the results is given, including the potential use of OSL from Al2O3 in the areas of space radiation dosimetry and radiation oncology. c2004 Elsevier Ltd. All rights reserved.

Heavy Ions↗

Laser-plasma instabilities in long scale-length plasmas relevant to shock-ignition

We present 2D particle-in-cell simulations of laser-plasma instabilities (LPI) performed using conditions relevant to experiments on the OMEGA and NIF laser facilities. The laser intensity used is 2×10 15 W cm -2 , which allows comparison with previous experiments and simulations investigating shock ignition, though this is a relatively low intensity for the scheme. We find that the large convective gain of the instabilities leads to dynamics that are largely controlled by pump depletion and to scattering or absorption by LPIs predominantly occurring away from the quarter-critical density. The two-plasmon decay (TPD) instability is dominant for OMEGA-type conditions and remains important at the NIF-scale. In both cases, most absorption from TPD occurs near its Landau cutoff density, and we examine its nonlinear dynamics in this region, focusing on the ion-acoustic waves responsible for saturation. For NIF-type conditions, stimulated Raman scattering (SRS) and stimulated Brillouin scattering divert significant fractions of laser energy, and we find that SRS backscatter can occur with high gain at low densities due to kinetic effects. An in-depth analysis of hot-electron production is performed to identify the main sources and their characteristic electron temperature. For both simulations presented, the overall hot-electron temperature lies between 30 and 35 keV. This is relatively low and will likely increase shock pressure; however, the distributions also contain a significant number of high-energy (E k >100 keV) electrons that would likely cause unacceptable preheat. We, therefore, suggest some strategies that may be utilized to minimize this high-energy component. I. INTROD

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Automated control and optimization of laser-driven ion acceleration

The interaction of relativistically intense lasers with opaque targets represents a highly non-linear, multi-dimensional parameter space. This limits the utility of sequential 1D scanning of experimental parameters for the optimization of secondary radiation, although to-date this has been the accepted methodology due to low data acquisition rates. High repetition-rate (HRR) lasers augmented by machine learning present a valuable opportunity for efficient source optimization. Here, an automated, HRR-compatible system produced high-fidelity parameter scans, revealing the influence of laser intensity on target pre-heating and proton generation. A closed-loop Bayesian optimization of maximum proton energy, through control of the laser wavefront and target position, produced proton beams with equivalent maximum energy to manually optimized laser pulses but using only 60% of the laser energy. This demonstration of automated optimization of laser-driven proton beams is a crucial step towards deeper physical insight and the construction of future radiation sources.

47 OTHER INSTRUMENTATION↗

The Uranium-Containing and Thorium-Containing Anions Studied by Photoelectron Spectroscopy

An in-depth knowledge of actinide chemistry is fundamental to many aspects of nuclear science and technology, including the synthesis and processing of materials and the remediation of waste disposal sites. Among the actinides, the chemical bonding behaviors of actinium and thorium resemble those of the transition metals; the 5f-electrons of protactinium, uranium, neptunium, and plutonium often play important roles in their bonding; and among the still heavier elements, their bonding tends to mimic the lanthanide elements in terms of electron shielding and their f-electron contributions. Bonding that involves 5f-electrons, however, is especially important, in part because of the significance of uranium and plutonium, but also because these elements are among the few where f-electron participation in bonding is relatively common. This work focused on studying uranium-containing and thorium-containing anions in the gas phase using negative ion photoelectron spectroscopy. Since this technique directly probed valence electrons, it was uniquely positioned to address open questions regarding molecular bonding and electron configurations. A particularly important issue concerned how bonding in actinide-containing molecules was affected by modifications to their actinide atoms’ environment, i.e., due to their interaction with ligands. A closely related question was how actinide atoms’ suborbitals were qualitatively reordered and their energies quantitatively shifted as a result of their ligated environments. These were especially relevant issues in regard to uranium due to it having multiple possible oxidation states (OS) and the potential for 5f electron participation in bonding. The effects of ligands on oxidation states and 5f-orbital energies in uranium bonding was expected to be pronounced. Both ligands and excess electrons were seen as probes of actinide atoms within actinide-containing molecules. Our strategy for advancing knowledge of chemical bonding in the actinide-containing species utilized the synergy between experiments and theory, where in some cases experimental results validated theory and where in others computational results assisted in interpreting experiments. Calculations on actinide systems are terrifically challenging due to large spin-orbit interactions, relativistic effects, and just the sheer number of electrons involved. Even in the simplest species, e.g., U and U2, the most sophisticated, modern calculations carried out by the most experienced theorists often only approximate experimentally-measured values, such as electron affinities. For theory to provide confident predictions that can be used to solve real problems it needed an iterative and ultimately corrective mechanism by which its methods can develop further. Experiments can be used to identify when theory has failed; whereupon the subsequent process of using the experiment-theory interplay can be used to find the cause of the failure. Upon fixing it in one case, different test species can be proposed and studied by the experiment-theory combination to determine whether the problem has been corrected. Thus, experiments not only measure the values of molecular properties, they also provide navigational 3 beacons that keep computations off the reefs in an otherwise dark sea with few reference points. Experimental measurements in the actinide field are not only important, they are in actuality essential to computational progress. While it was not always possible to compare the theoreticallydetermined quantity of interest directly with the same experimentally-measured observable, it was usually possible to compare consequential properties that are both calculable and measurable. In the work completed here electron affinities and electronic state spacings were often sensitive consequential parameters. Reasonable agreement between measured and computational values signaled that a calculation that was very likely to be on-track. We had established collaborative relationships with five computational groups, all of which have expertise in computational actinide chemistry. Their PI’s are L. Cheng, D. Dixon, L. Gagliardi, K. Peterson, and B. Vlaisavljevich. Our close interaction with our theory partners led to us suggesting systems to them and them to us. This reciprocal interaction between our experimental and their computational results was among the most important strengths of this work and was a thread woven throughout. Even though anion photoelectron spectroscopic studies are conducted on anions, much of the information that they provide, pertains to the electronic structure of the neutral counterparts of those anions; among these are electron affinities and electronically excited state spacings. Our experimental tools included several specialized ion sources for forming the anionic species of interest, a mass spectrometer for identifying and mass-selecting them, and an anion photoelectron spectrometer for determining their electron affinities (EA) and characterizing the electronic states of the selected anions’ neutral counterparts. Anion photoelectron spectroscopy is conducted by crossing a mass-selected beam of anions with a fixed-frequency laser beam and energy-analyzing the resultant photodetached electrons. The photodetachment process is governed by the energyconserving relationship: hν = EBE + EKE, where hν is the photon’s energy, EBE is the electron binding (photodetachment transition) energy, and EKE is the electron’s kinetic energy. In our apparatus mass-selection is accomplished via time-of-flight mass spectrometry (TOF-MS), electron energy analysis is achieved with either a magnetic bottle or by velocity mapped imaging. Photodetachment of electrons from anions is implemented via either Nd:YAG or excimer lasers. The photodetachment transition energy, i.e., the EBE, between the ground vibrational and electronic state of an anion and the ground vibrational and electronic state of that anion’s neutral counterpart is the adiabatic electron affinity (EA) of that neutral molecule. Likewise, photodetachment transitions between the ground vibrational and electronic state of an anion and the various electronically-excited states of that anion’s corresponding neutral map the electronic spectrum of that neutral species, i.e., the spectral spacings in the photoelectron spectrum are a mirror image of the neutral’s electronic spectrum. It was, of course, crucial to be able to form the anionic species of interest. There, we had a particularly broad field of anion sources from which to choose. These included several variants of pulsed laser vaporization (LV), laser photoemission, infrared desorption plus photoemission, pulsed arc discharge (PACIS), electrospray ionization (ESI), and Rydberg electron transfer (RET). Each of these anion sources were readily combined with, i.e., connected to, the anion photoelectron spectroscopic portion of our apparatus as described above. Among the sources that utilize lasers, visible light for LV sources as well as IR for desorption sources are provided by Nd:YAG lasers. Ultraviolet photons are provided by both Nd:YAG and excimer lasers, whereas the excitation wavelengths for RET experiments come from two Nd:YAG-pumped dye lasers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Data acquisition techniques for exploiting the uniqueness of the time-of-flight mass spectrometer: Application to sampling pulsed gas systems

Mass spectra are produced in most mass spectrometers by sweeping some parameter within the instrument as the sampled gases flow into the ion source. It is evident that any fluctuation in the gas during the sweep (mass scan) of the instrument causes the output spectrum to be skewed in its mass peak intensities. The time of flight mass spectrometer (TOFMS) with its fast, repetitive mode of operation produces spectra without skewing or varying instrument parameters and because all ion species are ejected from the ion source simultaneously, the spectra are inherently not skewed despite rapidly changing gas pressure or composition in the source. Methods of exploiting this feature by utilizing fast digital data acquisition systems, such as transient recorders and signal averagers which are commercially available are described. Applications of this technique are presented including TOFMS sampling of vapors produced by both pulsed and continuous laser heating of materials.

Lincoln, K. A.↗

Design and Demonstration of the Mars Organic Molecule Analyzer (MOMA) on the ExoMars 2018 Rover

The Mars Organic Molecule Analyzer (MOMA) investigation is a key astrobiology experiment scheduled to launch on the joint ESA-Roscosmos ExoMars 2018 rover mission. MOMA will examine the chemical composition of geological samples acquired from depths of up to two meters below the martian surface, where fragile organic molecules may be protected from destructive cosmic radiation and/or oxidative chemical reactions. The heart of the MOMA mass spectrometer subsystem (i.e., MOMA-MS) is a miniaturized linear ion trap (LIT) that supports two distinct modes of operation to detect: i) volatile and semi-volatile, low-to-moderate mass organics (less than or equal to 500 Da) via pyrolysis coupled with gas chromatography mass spectrometry (pyr/GCMS); and, ii) more refractory, moderate-to-high mass compounds (up to 1000 Da) via laser desorption (LDMS) at ambient Mars pressures. Additionally, the LIT mass analyzer enables selective ion trapping via multi-frequency waveform ion excitation (e.g., stored waveform inverse Fourier transform, or SWIFT), and structural characterization of complex molecules using tandem mass spectrometry (MSIMS). A high-fidelity Engineering Test Unit (ETU) of MOMAMS, including the LIT subassembly, dual-gun electron ionization source, micropirani pressure gauge, solenoid-driven aperture valve, redundant detection chains, and control electronics, has been built and tested at NASA GSFC under relevant operational conditions (pressure, temperature, etc.). Spaceflight qualifications of individual hardware components and integrated subassemblies have been validated through vibration, shock, thermal, lifetime, and performance evaluations. The ETU serves as a pathfinder for the flight model buildup, integration and test, as the ETU meets the form, fit and function of the flight unit that will be delivered to MPS in late 2015. To date, the ETU of MOMA-MS has been shown to meet or exceed all functional requirements, including mass range, resolution, accuracy, instrumental drift, and Iimit-of-detection specifications, thereby enabling the primary science objectives of the MOMA investigation and ExoMars 2018 mission.

Mars Organic Molecule Analyzer↗

Physics Division Strategic Plan Fiscal Years 2020-2024

The vision of the Physics Division (PHY) at Argonne National Laboratory is to continue enhancing its role as a world-leading institution in basic nuclear physics research and its applications. Key to this vision is for PHY to continue to safely and effectively operate and evolve the capabilities of the Argonne Tandem Linac Accelerator System (ATLAS) facility to best serve its users. ATLAS is the Department of Energy (DOE) accelerator facility for low-energy nuclear physics research. The research carried out by PHY covers many themes in contemporary science but can be distilled into five areas of focus. These themes are interconnected, with continuously evolving synergies between the various groups and facilities in PHY and the broader Laboratory. This five-year strategic plan serves to illustrate our current capabilities and new directions related to these five areas of focus (ATLAS also develops an independent strategic plan): Accelerator research and design. The goal of this theme is to design, fabricate, test, and implement novel accelerator systems, with a focus on high-intensity ion and electron systems. These R&D activities have led to enhancements in the ATLAS accelerator system. Among others, the division’s accelerator systems are in use or planned for use at Fermilab, the Advanced Photon Source, and in a broad variety of applications at the Facility for Rare Isotope Beams (FRIB). Atom trapping and fundamental symmetries. The goal of this theme is to explore and exploit the uses of advanced laser cooling and trapping techniques to manipulate atoms. There are three main areas of focus. First is in the application of the atom trap trace analysis (ATTA) technique for age determination of groundwater and ice by using radio-krypton dating. The next two trapping-based programs involve tests of fundamental symmetries in nature: the cooling and trapping of radium-225 with the aim of determining limits on an observation of its electric dipole moment and precision measurements of the beta decay properties of helium-6 to set limits on the tensor coupling constant. This is complemented by measurements of similar properties in lithium-8 and boron-8. Nuclear astrophysics. The goal of this theme is to enhance our understanding of how elements are created in the universe via explosive nucleosynthesis and how stars evolve. To meet the challenges of this theme, many of the capabilities of ATLAS are being enhanced, including the development of new beams through a new in-flight separator (RAISOR) and the anticipated neutron-generator upgrade of the Californium Rare Isotope Breeder Upgrade facility (nuCARIBU). These are coupled to state-of-the-art instruments such as the Canadian Penning Trap, Helical Orbit Spectrometer, Gammasphere, GRETINA, Multi-Sampling Ionization Chamber, the Fragment Mass Analyzer, and Argonne Gas-filled Fragment Analyzer, and a new low-background experimental area for decay studies. Nuclear structure. The goal of this theme is to understand the structure of nuclei, both stable and radioactive, in terms of single-particle properties, their shapes, and the dynamics governing reactions between them. These include questions such as what are the limits of nuclear stability and what are the properties of super heavy nuclei. As with the nuclear astrophysics theme, the capabilities of ATLAS, guided by the ATLAS user community, are continuously being enhanced to this end. The Division has strategic initiatives to play a leading role in the development of instrumentation and research programs at the FRIB. Quantum chromodynamics (QCD) and hadron physics. The goal of this theme is to lead major research programs focused on revealing the quark and gluon structure of protons, neutrons, nuclei, and short-lived mesons and baryons. These involve major programs at Jefferson Lab, Fermilab, and smaller facilities. They are complemented by theoretical endeavors centered on the question of how hadrons and their properties emerge from QCD. Out of these activities arise strategic initiatives to play a major role in the forthcoming Electron-Ion Collider (EIC).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ion Channel Laser Based on Direct Laser Acceleration of a Shaped Beam Driver (Final Technical Report)

The main focus of our research was to understand the synergies between an electron bunch and a laser pulse when the two co-propagate through the plasma. We have clearly demonstrated using theoretical and computational modeling that the propagation distance of both the bunch and the laser pulse could be extended. The ability of the combined bunch/pulse system to extend the propagation distance and the size of the plasma bubble enables highly-efficient sources of relativistic electrons. As pointed out by the Plasma Decadal Study, such electron sources can be used for generating extremely bright x-rays for a variety of applications can serve as probes and diagnostics for other plasma experiments: high energy density (HED) sciences, inertial confinement fusion (ICF), and potentially Fusion Materials and Technology (FM&T). Development of advanced diagnostics of plasma-based accelerators is yet another key area identified by recent reports. Even broader security and medical applications of compact accelerator-based radiation sources, such as very high energy electron (VHEE) sources for FLASH radiobiology, have been identified by a recent multi-agency panel. A number of key technical issues were considered and successfully resolved during the course of the grant. Those include: beam loading effect of both the driver and witness bunches on the wake, laser channeling by the bunch, and the direct laser acceleration (DLA) of the driver bunch by the laser pulse. To demonstrate clear synergy, we were able to ascertain that the total energy gain of a witness bunch in the wake of the combined bunch/laser complex is large than the sum of the energy gains in the wake of the laser pulse alone, and the driver bunch alone. We have also demonstrated that not only the energy gain is improved, but the energy spread is not sacrificed. To carry out these simulations, we have to develop a range of in-house computational tools, including a fully-3D code WAND-PIC.

43 PARTICLE ACCELERATORS↗

Optical Fiber Spectroscopy

This is the final report of work done on NASA Grant NAG-1-443. The work covers the period from July 1, 1992 to December 1, 1998. During this period several distinct but related research studies and work tasks were undertaken. These different subjects are enumerated below with a description of the work done on each of them. The focus of the research was the development of optical fibers for use as distributed temperature and stress sensors. The initial concept was to utilize the utilize the temperature and stress dependence of emission from rare earth and transition metal ions substitutionally doped into crystalline or glass fibers. During the course of investigating this it became clear that fiber Bragg gratings provided a alternative for making the desired measurements and there was a shift of research focus on to include the photo-refractive properties of germano-silicate glasses used for most gratings and to the possibility of developing fiber laser sources for an integrated optical sensor in the research effort. During the course of this work several students from Christopher Newport University and other universities participated in this effort. Their names are listed below. Their participation was an important part of their education.

Buoncristiani, A. M.↗

A compact and portable gamma-ray spectrometer (GRASP) for inertial confinement fusion and basic science experiments

A compact and portable gamma-ray spectrometer has been designed to diagnose different components of the inertial confinement fusion-relevant γ-ray spectrum with energies between ∼3.7–17.9 MeV. The system is designed to be as compact as possible for convenient transportation and fielding in diagnostic ports on the OMEGA laser, the National Ignition Facility, and other photon-source facilities. The system consists of a conversion foil for Compton scattering in front of four magnetic spectrometer “arms,” each covering a different energy range and constructed out of cylindrical permanent magnet Halbach arrays. Monte Carlo simulations have been used to optimize and assess the performance of the conversion foil, and COSY INFINITY ion-optical simulations have been used to optimize the spectrometer magnets. The performance of the design is assessed for a simulated direct-drive γ-ray spectrum. Spanning its total γ-ray energy bandwidth and using a 1.7 mm thick boron conversion foil, the system’s total energy resolution and efficiency are ∼15.8%–4.5% and 5.4 × 10−7–3.7 × 10−7e−/γ, respectively, with room for improvement. Spectral γ-ray measurements will provide guidance to the inertial confinement fusion program toward achieving high-energy gain relevant to inertial fusion energy and enable new measurement capabilities for basic discovery science.

Instruments & Instrumentation↗