Real-time elemental analysis of liquids for process monitoring using laser-induced breakdown spectroscopy with a liquid wheel sampling approach

This article presents an engineered sampling system that used a rotating wheel to form a thin liquid layer, permitting the use of laser-induced breakdown spectroscopy (LIBS) for in situ, real-time elemental impurity quantification during liquid processing. The sampling approach was demonstrated on eight elements from across the periodic table (Na, Al, K, Ca, Ti, Sr, Mo, and Yb). Univariate and multivariate calibrations were presented for each element. The average value for percent root mean square errors of cross-validation for the multivariate models was 3.64%, highlighting the method's strong prediction accuracy. Additionally, the limits of detection for each analyte were estimated from their univariate models: Na = 0.0532, Al = 18.5, K = 0.105, Ca = 0.273, Ti = 67.7, Sr = 0.640, Mo = 22.4, and Yb = 22.9 μg mL –1 . Finally, a test in which multivariate models were used to monitor a liquid system for 80 min was performed to investigate the real-time monitoring capabilities of this liquid LIBS sampling approach. Rigorous measurements were performed to effectively predict the absence and concentrations of multiple analytes as they were spiked and diluted. This demonstration showed the feasibility of using LIBS for real-time liquid quantification models with estimated precision ≤ 8.1%. Finally, the limitations of this approach and potential future improvements are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In-Situ Laser-Induced-Desorption-Spectroscopy Diagnostic Deployment on the Linear Plasma Device CSDX

A calibrated laser induced desorption diagnostic (LIDS) concept is developed under this award for application to fusion relevant plasma materials interactions studies. Small areal amounts of hydrogenic release from a deuterium filled PMI target are measured and quantified when irradiated by a LID flash heat event on the target surface. Good success was demonstrated by this project with the PISCES-E rf plasma device at UCSD by fully quantified measurement and removal of D from W-D co-deposit layers in experiments. However, adapting the LIDS technique to D plasma exposed W targets in the linear plasma CSDX device, now labelled PISCES-Rf, was prone to several technical challenges ranging from target line of sight access, laser focusing, and loss of optical spectroscopic signal strength in the larger PISCES-Rf vacuum system. The results are summarized in this report.

08 HYDROGEN↗

Cell design for laser-induced breakdown spectroscopy measurements on reactive gas samples

Uranium hexafluoride (UF 6 ) is the primary material used for the enrichment of uranium in the production of light water nuclear reactor fuels worldwide. Accurate, rapid quantification of uranium isotopic composition in nuclear materials is required for safeguards programs and nonproliferation purposes. One potential technique for isotopic measurements in uranium species in the field is laser induced breakdown spectroscopy (LIBS). Safe and effective application of LIBS to UF 6 for enrichment measurements is uniquely challenging due to the chemical and physical properties of UF 6 , which necessitate specific handling procedures. The objective of this work is to design a cell for isotopic analysis of UF 6 that is (1) compatible with chemical and physical properties of UF 6 , (2) compatible with LIBS laser, and (3) portable-sized for nuclear safeguards applications. Along with cell design, initial testing of the cell for basic performance and chemical compatibility is performed. As designed and constructed, the portable gas cell was gas-tight, chemically compatible with UF 6 , and withstood long-duration laser exposure. In this work, the cell has proven capability for handling reactive gasses, such as UF 6 , with specification application to isotopic analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design of a Molten Salt Flow Cell for Combined Absorbance and Laser-Induced Breakdown Spectroscopy for Online Measurements

A novel flow cell allowing for multiple optical spectroscopy measurements on flowing molten salts was designed, and demonstrative calibrations of impurities in aqueous samples were performed. Online compositional measurements of molten salts are of high interest to monitor the state of relevant solar and nuclear systems. Here, the Spectroscopic Configuration for Optical Real-Time Characterization of High-Temperature (SCORCH) fluids cell was designed to meet this need by providing optical access to a high-temperature molten salt sample stream without physical contact between the sample and window materials. Laser-induced breakdown spectroscopy (LIBS) was utilized to quantify Li, Cr, Fe, Ni, Sr, and Pr at concentrations ranging nominally from 0 to 315 mmol L −1 . Laser power, frequency, and plasma position were optimized to mitigate challenges associated with sample splashing. Univariate calibration models were built with R 2 > 0.98, percent root mean square error of cross-validation (%RMSECV) as low as 2.7%, and limits of quantification (LOQs) down to 4.1 mmol L −1 . Simultaneously, absorbance calibrations were developed for the applicable analytes (Cr, Ni, and Pr) using Beer’s law with a pathlength of 4.41 ± 0.10 mm. These models provide excellent quantification performance with R 2 > 0.999, %RMSECV as low as 0.6%, and LODs down to 0.08 mmol L −1 . Although these calibrations were performed for each spectroscopic technique separately, the two methods may be combined in the future through multivariate modeling and sensor fusion to provide more robust models with the benefits of both techniques (e.g., absorbance: oxidation state concentrations, LIBS: elemental concentration). Additionally, optimized spectrometers may be deployed to enhance sensitivity.

absorbance spectroscopy↗

Comparison of excitation and kinetic temperatures in a laser-produced plasma using absorption spectroscopy

High-resolution tunable laser absorption spectroscopy is used to measure time-resolved absorption spectra for six neutral uranium transitions in a laser-produced plasma. Here analysis of the spectra shows that kinetic temperatures are similar for all six transitions, but excitation temperatures are higher than kinetic temperatures from 10–100 μs, indicating departures from local thermodynamic equilibrium.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Machine Learning–Augmented Laser-Induced Breakdown Spectroscopy for Spectral Discrimination of Iron Oxalates

Enhanced characterization and phase identification of post-PUREX Pu Oxalates (PuOXA) are pivotal for nonproliferation and pre-detonation nuclear forensics. Despite significant advances in the characterization of PuO 2 samples, little is known about the impact of both the chemical structure and oxidation states of PuOXA (i.e., Pu(III) and Pu(IV)) have on optical emission signatures. Here, we demonstrate the analytical capabilities of laser-induced breakdown spectroscopy (LIBS) applied to Fe(II) and Fe(III) oxalate samples as surrogates for PuOXA, highlighting the discriminating features in the LIBS emission spectra arising from differences in the oxidation states within mixed FeOXA samples. We report the enhancement of spectral feature selection using Principal Component Analysis (PCA), which enables the analytical superiority of machine learning algorithms such as Linear Discriminant Analysis (LDA), Quadratic Discriminant Analysis (QDA), Partial Least Squares Regression (PLSR), Support Vector Regression (SVR), and Random Forest Regression (RFR) over conventional univariate techniques for phase discrimination and chemometric analysis. Cluster analysis revealed how both matrix effects and laser ablation influence cluster separability by introducing spectral artifacts that misdirect the maximization of variance. PCA-selected emission lines were used in the regression models, demonstrating that both univariate and multivariate linear regression models (i.e., PLSR and SVR) can achieve acceptable performance, with machine learning models outperforming conventional calibration regressions. Furthermore, the application of non-linearly activated PCA-selected emission lines illustrates how simplifying the data while retaining captured variance enables the use of less complex and more computationally efficient models. Furthermore, this is particularly evident in the underperformance of RFR, which suffers from increased computational costs and overfitting owing to its high complexity.

Oxalates↗

Calibration-Free Quantitative Analysis of Lithium-Ion Battery (LiB) Electrode Materials Using Laser-Induced Breakdown Spectroscopy (LIBS)

Recent years have seen a surge in the demand for high-performance battery electrode materials for automotive and various electronic device applications. Improving battery performance requires precise knowledge of the structure–composition properties of active electrode materials. To this effect, quantitative and precise estimation of the composition of advanced electrode materials, containing trace amounts of dopants, provide immense value toward developing next-generation high-capacity battery materials. Herein, we demonstrate the application of calibration-free laser-induced breakdown spectroscopy (LIBS) as a powerful analytical tool for rapid and reliable quantitative spectrochemical characterizations of layered Li metal oxide cathodes containing Mo and Cr dopants (<5 atom %). Specifically, we employ the LIBS using an internal calibration methodology to establish the quantitative elemental ratios of major (Ni, Mn, Co) and trace dopant (Cr, Mo) transition metals to bulk Li contents in diverse cathode material samples such as LiNi 0.5 Mn 0.5 O 2 (NM-50/50), LiNi 0.33 Mn 0.33 Co 0.33 O 2 (NMC), LiNi 0.317 Mn 0.317 Co 0.317 Cr 0.05 O 2 (Cr-doped NMC), and LiNi 0.5– x /2 Mn 0.5– x /2 Mo x O 2 ( x = 0.03, 0.04, 0.05) (Mo-doped NM-50/50) that were synthesized via sol–gel routes. The LIBS-estimated elemental compositions are in good agreement with the nominal stoichiometric values. Furthermore, ex situ LIBS characterizations presented here pave the path for future high-efficacy application of calibration-free quantitative LIBS for rapid in situ analyses of elemental composition changes in battery electrode materials under operation that need not resort to off-site analytical techniques requiring cumbersome sample preparations and/or external standards.

25 ENERGY STORAGE↗

Spectral Data Fusion From Handheld Laser-Induced Breakdown Spectroscopy (LIBS) and X-ray Fluorescence (XRF) Analyzers for Improved Detection of Cerium in a Simulated Dispersal Accident

Here, this work implements a mid-level data fusion methodology on spectral data from handheld X-ray fluorescence and laser-induced breakdown spectroscopy analyzers to quantify plutonium surrogate (CeO 2 ) contamination in soil samples for the first time. Spectral data from each analyzer were used independently to train supervised machine learning regressions to predict Ce concentration. Fused features from both data sets were then used to train the same models, comparing prediction performance by evaluating model precision and sensitivity. Fusing principal component scores from the two sensors yielded an order of magnitude improvement in precision and sensitivity of predictions made with an artificial neural network, compared to predictions made by models trained on independent sensor data. As a result, a boosted ensemble trained on the fused spectral features yielded an ideal predictor with root-mean-squared error on the order of 10 –6 and calculated limit of detection order 10 –5 wt %.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monitoring Xenon Capture in a Metal Organic Framework Using Laser-Induced Breakdown Spectroscopy

Molten salt reactor operation will necessitate circulation of a cover gas to remove certain evolved fission products and maintain an inert atmosphere. The cover gas leaving the reactor core is expected to contain both noble and non-noble gases, aerosols, volatile species, tritium, and radionuclides and their daughters. To remove these radioactive gases, it is necessary to develop a robust off-gas system, along with novel sensors to monitor the gas stream and the treatment system performance. In this study, a metal organic framework (MOF) was engineered for the capture of Xe, a major contributor to the off-gas source term. The engineered MOF column was tested with a laser-induced breakdown spectroscopy (LIBS) sensor for noble gas monitoring. The LIBS sensor was used to monitor breakthrough tests with various Xe, Kr, and Ar mixtures to determine the Xe selectivity of the MOF column. This study offers an initial demonstration of the feasibility of monitoring off-gas treatment systems using a LIBS sensor to aid in the development of new capture systems for molten salt reactors.

47 OTHER INSTRUMENTATION↗

Rapid in situ nutrient element distribution in plants and soils using laser-induced breakdown spectroscopy ($\mathrm{LIBS}$)

The aim of this study is to develop and test the applicability of a rapid in situ plant chemistry profiling technique to determine elemental composition of small-volume plant and soil samples obtained from a woody bioenergy crop species, Populus trichocarpa. Expanding the research tools available to characterize the nutrient element correlations among plant tissue types and soil depths is a critical need in the path of understanding productivity and adaptation of plants to variations in external abiotic and biotic factors and developing sustainable perennial bioenergy crops that are co-optimized for biomass valorization aboveground and carbon sequestration belowground. Several plant root, stem, and soil samples were tested using laser-induced breakdown spectroscopy (LIBS) to evaluate the presence and distribution of nutrient elements. Samples were tested as collected and after being dried and cross sectioned to evaluate the effectiveness of using LIBS for in situ analysis on plant samples. The collected LIBS spectra show the elemental peaks were the same in both the as collected and prepared samples for roots and stems. Qualitative amounts of elements such as H, C, N, O, Li, Na, Mg, K, Ca, Fe, Al, and Si were able to be identified rapidly in raw samples. Here in this report we demonstrate suitability of LIBS in obtaining rapid, in situ, elemental distribution in plant and soil samples, utilizing only small sample volumes and minimal sample preparation. This demonstration opens up a new rapid phenotyping avenue necessary to fill the asymmetrical knowledge gaps in belowground performance of plant systems.

59 BASIC BIOLOGICAL SCIENCES↗

Dynamic deuterium retention properties of tungsten measured using laser-induced breakdown spectroscopy

Dynamic deuterium (D) retention properties of tungsten (W) are investigated under steady-state D plasma exposure in the PISCES-A linear plasma device. In contrast to static retention, dynamic retention is quickly released from the material at the termination of the incident plasma flux, and thus in-operando laser-induced breakdown spectroscopy (LIBS) measurements have been conducted during steady-state D plasma exposure. A procedure is, first, established to extract the dynamic retention component from the in-operando LIBS D I 656.1 nm line intensity, which can contain contributions from dynamic and static retention as well as background D/D 2 gas, excited by both steady-state and laser-induced plasmas. Using the developed procedure, the dynamic D retention in W is systematically examined while scanning the following plasma exposure parameters: incident ion energy, E i , sample temperature, T s , incident ion flux, Γ i . No clear E i dependence is seen in the range of E i ~ 45–175 eV, as expected from a small variation in the average implantation depth (~3-6 nm) of D in W. The dynamic retention is found to monotonously decrease with increasing T s from 348 to 573 K, while the total static retention is reported to peak at T s ~ 500–600 K. It is revealed that the dynamic retention linearly increases with increasing Γ i , and then saturates at Γ i ≥ 0.75 × 10 21 m –2 s –1 . Possible physical mechanisms for the observed dependence of the dynamic retention on T s and Γ i are discussed. Furthermore, sequential pure He, followed by pure D, plasma exposures show that the dynamic D retention is not strongly affected by He bubbles in the near-surface region.

super-saturated surface layer↗

Optimization of laser-induced breakdown spectroscopy for liquid sodium analysis

Next-generation nuclear power reactors based on liquid sodium coolant are in development to improve efficiency and safety. Fast breeder reactors could potentially achieve considerably higher fuel burn-up while producing less nuclear waste compared with current commercial technology. Monitoring of impurities in these types of reactors is important in order to prevent blockage of the cooling system or hazardous reactions due to the high reactivity of sodium with water. In this work, laser-induced breakdown spectroscopy is performed on a liquid sodium sample using a custom-built immersion probe system. The probe provides direct line of sight to the sample vessel in argon atmosphere for laser delivery and signal collection. Signatures of sodium, and impurities such as potassium and oxygen have been obtained. The probe height and immersion have a strong influence on the signal level and stability. Argon flow rates of 2 to 5 liters per minute produce no substantial change in signal, suggesting a steady laminar flowing regime. A high signal-to-noise ratio for impurity elements confirms the suitability of this technique for reliable impurity detection and monitoring in the reactor environment.

Gardette, V. [University of Michigan, Ann Arbor, M↗

Real-Time Elemental and Isotopic Measurements of Molten Salt Systems through Laser-Induced Breakdown Spectroscopy

Molten salt reactors are an emerging advanced nuclear reactor concept in which the fuel is dissolved into the working fluid in the form of a high-temperature molten salt. The complex, mobile, and corrosive nature of this fluid presents a fundamental challenge for analytical measurements. Tracking species throughout the reactor is important for ensuring proper operation. This article presents laser-induced breakdown spectroscopy (LIBS) used to monitor the elemental composition of a molten salt and corresponding hydrogen isotopic shifts in real-time. A NaNO 3 –KNO 3 eutectic salt was saturated with protium and deuterium gases, then the effluent aerosol stream formed using an argon sparging vessel was monitored with LIBS. This modular LIBS system permitted several spectrometers to be used simultaneously to capture high-resolution isotopic shifts and provide broadband elemental coverage. Further, the results exhibit how LIBS can be used to understand salt–gas chemical and physical interactions such as diffusion. Furthermore, LIBS’ broad elemental coverage can provide greater insight into the chemical reactions within the salt vessel such as the formation of water vapor by monitoring hydrogen and oxygen signatures simultaneously. Ultimately, this study demonstrates the analytical possibilities of LIBS for real-time monitoring of isotopes and elemental composition in molten salt systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser-Induced Breakdown Spectroscopy (LIBS) Sensing for Environmental and Subsurface Monitoring

Groundwater monitoring is essential to timely and accurately reflect the current situations and the trends of water quality. However, the long-term stability and survival of any potential in-situ monitoring method is threatened by the harsh conditions and the groundwater monitoring in downhole environments poses numerous challenges to the sensor community. Laser induced breakdown spectroscopy (LIBS) has been demonstrated as a promising technology for chemical monitoring in high-temperature high-pressure (HTHP) environments and hard to reach places. The technique demonstrates several advantages, such as rapid, real-time, in-situ, and simultaneous detection of multiple elements with simple or no sample preparation. This chapter includes a brief review of the field-portable LIBS systems, and development of a compact, robust, and simple LIBS instrument for downhole HTHP water quality monitoring. The fieldable prototype sensor is tested in an onsite monitoring well where trace elements’ concentrations are tracked over an extended period. The testing has verified that the fiber coupled design performs as desired. The system shows good calibration linearity for tested elements and collection times, and Limits of Detection (LODs) that are comparable to those of tabletop LIBS instruments. In addition to groundwater quality monitoring, the fabricated LIBS-based sensor could have widespread sub-surface detection applications.

Jain, Jinesh [NETL Site Support Contractor, Nation↗

Fungal elemental profiling unleashed through rapid laser-induced breakdown spectroscopy (LIBS)

Elemental profiling of fungal species as a phenotyping tool is an understudied topic and is typically performed to examine plant tissue or non-biological materials. Traditional analytical techniques such as inductively coupled plasma–optical emission spectroscopy (ICP-OES) and inductively coupled plasma–mass spectrometry (ICP-MS) have been used to identify elemental profiles of fungi; however, these techniques can be cumbersome due to the difficulty of preparing samples. Additionally, the instruments used for these techniques can be expensive to procure and operate. Laser-induced breakdown spectroscopy (LIBS) is an alternative elemental analytical technique—one that is sensitive across the periodic table, easy to use on various sample types, and is cost-effective in both procurement and operation. LIBS has not been used on axenic filamentous fungal isolates grown in substrate media. In this work, as a proof of concept, we used LIBS on two genetically distinct fungal species grown on a nutrient-rich and nutrient-poor substrate media to determine whether robust elemental profiles can be detected and whether differences between the fungal isolates can be identified. This data set contains the raw LIBS spectral data for the summarized results described inRush, et. al. 2024

elemental profiling↗

457-nm radiation source based on a diode laser for precision spectroscopy of magnesium atoms

We report on the development of a highly stable source of 457-nm radiation based on a diode laser and a tapered amplifier operating in a double-pass scheme. The diode laser frequency was stabilised by a high-Q reference Fabry – Perot interferometer and doubled in a PPSLT nonlinear crystal placed in an enhancement cavity. At a maximum output power of 200 mW at a wavelength of 457 nm, the laser linewidth was less than 5 kHz. The radiation source operation was demonstrated in experiments on precision spectroscopy of cold magnesium atoms in a magneto-optical trap. (lasers)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection and quantification of trace technetium in the presence of molybdenum using laser-induced breakdown spectroscopy

Technetium (Tc) is a very important element that is encountered in many aspects, from its presence in radioactive waste and its potential environmental impact to its use as a medical radioisotope. Its detection and quantification in liquid samples is traditionally cumbersome, involving detailed sample preparation and analysis by mass spectrometry or scintillation. This article demonstrates the first comprehensive emission spectral analysis of Tc from a liquid sample by immobilization in a polymer and analysis by laser-induced breakdown spectroscopy (LIBS). A survey of LIBS spectra was completed to identify the strongest analytical lines for quantification of trace Tc in the presence of Mo. The quantification of Tc in a Mo-containing matrix was selected because Tc radioisotopes are the daughter products of Mo isotope decay. The first reported calibration curves by LIBS are provided with limits of detection and quantification down to 0.710 µg mL −1 and 1.39 µg mL −1 , respectively. Ultimately, this study demonstrated the feasibility of trace Tc quantification using LIBS and will serve as a reference for future research related to monitoring this radioactive species.

Andrews, Hunter B. [Oak Ridge National Laboratory ↗