Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

The Fringe-Imaging Skin Friction Technique PC Application User's Manual

A personal computer application (CXWIN4G) has been written which greatly simplifies the task of extracting skin friction measurements from interferograms of oil flows on the surface of wind tunnel models. Images are first calibrated, using a novel approach to one-camera photogrammetry, to obtain accurate spatial information on surfaces with curvature. As part of the image calibration process, an auxiliary file containing the wind tunnel model geometry is used in conjunction with a two-dimensional direct linear transformation to relate the image plane to the physical (model) coordinates. The application then applies a nonlinear regression model to accurately determine the fringe spacing from interferometric intensity records as required by the Fringe Imaging Skin Friction (FISF) technique. The skin friction is found through application of a simple expression that makes use of lubrication theory to relate fringe spacing to skin friction.

Zilliac, Gregory G.↗

ON THE ACCURACY OF MEASUREMENTS MADE UPON FILMS PHOTOGRAPHED BY BAKER-NUNN SATELLITE TRACKING CAMERAS

The photographs taken by the Baker-Nunn cameras of the Smithsonian Astrophysical Observatory were formerly measured with Van Biesbroeck goniometers, but are now measured exclusively with Mann two-screw comparators. Instead of measuring point images, we usually have to measure oblong images, either trails or breaks (the latter produced by interruption of the exposure). We can therefore expect that the accuracy of the determination of their positions is more influenced by the personal errors than it is in conventional astrometry. Approximately 800 measurements were made on 34 images of different length, and, from these, the frequency distribution of settings was determined. Then the relationship between this distribution and the length of the image (trail or break) was examined, and the relationship between the "magnitude error" and the length of image was determined. Measurements were made at different angles formed by the trails and the reticle lines, and it was found that the accuracy was not affected by the angle of the setting. Position determinations have been made using reference stars at different distances. On the basis of these results, we can conclude that the accuracy is neither influenced by the distortion of the emulsion nor by the optical distortion within an area of a diameter of S cm (5°.8). We believe that we are justified in using the linear plate constant method, at least within this area. From numerous double and multiple measurements, the following standard errors were determined for a single position.

ASTROMETRY↗

Heat Flux Analysis From IR Imaging on Proto-MPEX

The Prototype Material Plasma Exposure eXperiment (Proto-MPEX) is a linear device used to develop the source and heating concept for MPEX, an experiment to study plasma–material interactions for future fusion reactors. This paper highlights recent analysis and results on Proto-MPEX using an infrared (IR) camera, a key tool for imaging heat fluxes measured at the material target. The target heat fluxes are crucial to understanding the source and heating concepts. The recent analysis includes the application of homography and 3-D finite-element methods to provide between-shot measurements of the 2-D target heat flux profile. The IR camera inferred heat flux is shown to correlate with Langmuir probe inferred heat fluxes for a range of parameters in helicon only and helicon + electron cyclotron heated discharges. Results show both desirable central and undesirable edge heat flux for helicon source and electron heating on the target. These heat flux measurements are shown to be important for better understanding of the source and heating physics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-Speed Linear Raman Spectroscopy for Instability Analysis of a Bluff Body Flame

We report a high-speed laser diagnostics technique based on point-wise linear Raman spectroscopy for measuring the frequency content of a CH4-air premixed flame stabilized behind a circular bluff body. The technique, which primarily employs a Nd:YLF pulsed laser and a fast image-intensified CCD camera, successfully measures the time evolution of scalar parameters (N2, O2, CH4, and H2O) in the vortex-induced flame instability at a data rate of 1 kHz. Oscillation of the V-shaped flame front is quantified through frequency analysis of the combustion species data and their correlations. This technique promises to be a useful diagnostics tool for combustion instability studies.

Kojima, Jun↗

More About Video-Feedback Docking System

Two documents provide additional information on system described in "Docking System With Video Feedback" (MFS-28421). First document, "Standard Remote Manipulator System Docking Target Augmentation For Automated Docking", emphasizes use of retroreflectors in target. Second document, "Development Of A Video-Based Automatic Rendezvous And Docking System", describes hardware and software of system. System is video-sensor/electronic-feedback control system. Video camera on active or chasing vehicle views target on passive or chased vehicle. Target illuminated by light-emitting diodes on active vehicle. Image-data-processing subsystem converts video image of target into data on relative position, orientation, linear velocity, and angular velocity of two vehicles. Data then used by maneuver-control subsystem to control approach of active vehicle to passive vehicle.

Howard, Richard↗

Using Enviro-Pod low altitude imagery to inventory building surface materials for an acid rain study - A Baltimore example

Low altitude, oblique and vertical color photography taken from EPA's Enviro-Pod Ka 85 camera system has provided the data for taking an inventory of building surface materials in a test area of downtown Baltimore. Photography was acquired from a gridded flight plan to provide views of all sides of buildings. Color, texture, and linear detail are employed in the photo interpretation aided by contextual reference to a classification of building construction type developed in an earlier study. The work could potentially support a materials inventory initiated by the National Acid Precipitation Assessment Program (NAPAP) by scientists from EPA, Geological Survey, and the Department of Energy. Initial results show the method to be viable. Discrete surface materials such as brick, both bare and painted, stone, and metal are identified.

Ellefsen, Richard↗

Ice Growth Measurements from Image Data to Support Ice-Crystal and Mixed-Phase Accretion Testing

This paper describes the imaging techniques as well as the analysis methods used to measure the ice thickness and growth rate in support of ice-crystal icing tests performed at the National Research Council of Canada (NRC) Research Altitude Test Facility (RATFac). A detailed description of the camera setup, which involves both still and video cameras, as well as the analysis methods using the NASA Spotlight software, are presented. Two cases, one from two different test entries, showing significant ice growth are analyzed in detail describing the ice thickness and growth rate which is generally linear. Estimates of the bias uncertainty are presented for all measurements. Finally some of the challenges related to the imaging and analysis methods are discussed as well as methods used to overcome them.

Struk, Peter, M↗

Ice Growth Measurements from Image Data to Support Ice Crystal and Mixed-Phase Accretion Testing

This paper describes the imaging techniques as well as the analysis methods used to measure the ice thickness and growth rate in support of ice-crystal icing tests performed at the National Research Council of Canada (NRC) Research Altitude Test Facility (RATFac). A detailed description of the camera setup, which involves both still and video cameras, as well as the analysis methods using the NASA Spotlight software, are presented. Two cases, one from two different test entries, showing significant ice growth are analyzed in detail describing the ice thickness and growth rate which is generally linear. Estimates of the bias uncertainty are presented for all measurements. Finally some of the challenges related to the imaging and analysis methods are discussed as well as methods used to overcome them.

Struk, Peter M.↗

TOWARD A METHOD FOR SCALING HUMAN BODY MODELS IN AN IMU-BASED WORKFLOW

BACKGROUND Scaled biomechanical models can more accurately inform crew health decisions when tailored to the wide range of astronaut sizes. One component to improve scaling of existing models to better represent each unique astronaut’s size is the individual length scaling of limbs. Traditionally, these lengths are determined by motion capture or manual measurement. A new method is herein proposed for length scaling which can be done by measuring linear and angular accelerations at a desired point during isolated motion around a point of rotation, then calculating the distance between the desired point and point of rotation. When an Inertial Measurement Unit (IMU) device is placed at the distal point of a limb, the isolated motion is about that limb’s proximal joint. For example, to measure forearm length, an IMU is placed at the wrist, the point of rotation is at the elbow, and the isolated motion is forearm flexion and extension. These calculated lengths are then used to scale models to each unique astronaut’s size, thereby improving the applicability of the model. This method of scaling limb segments can be used for any limb that has an easily defined proximal joint for the limb to rotate around including hands, arms, legs, feet. Utilizing IMUs for data collection also provides the synergistic ability to record data without a dedicated space in a room with many cameras, therefore reducing the data collection footprint, or record data where optical motion capture is not possible, such as inside a spacesuit. METHODS AND RESULTS To test this method, upper body data collection was performed with 5 Xsens DOT IMUs on a single subject. IMUs consist of an accelerometer, a gyroscope, and a magnetometer which collect linear acceleration, angular velocity, and magnetic fluctuations, respectively. Before any ground-based laboratory collection, the magnetic fluctuations are used to correct the heading of the IMU in space relative to the Earth’s magnetic field. The direct measurement of angular velocity is integrated to calculate angular acceleration. Then the linear acceleration ( a ) and angular acceleration (α) are solved using r = at/α to calculate the radius, which in this case is the distance between the IMU and the point of rotation (i.e., segment length). The IMU must be placed at the most distal point of the limb being measured (i.e., ankle if measuring lower leg length) and the test plan must consist of an isolated motion about that limb’s proximal joint (i.e., knee flexion and extension if measuring lower leg length). The distances (radii) calculated at every time interval were filtered (bandpass filter keeping 5th-90th percentile data) to eliminate outliers and spurious data that occur when the isolated motion was stopped or nearly stopped. The remaining distances were averaged, resulting in the calculated limb length. Scaling factors were then computed by dividing the calculated limb length by the unscaled model’s length. These scale factors are plugged into the Scale Tool in OpenSim [1,2] to apply the scaling to the OpenSim Full Body Rajagopal Model [3,4]. Manual measurements of limb lengths were taken before data collection started and used for comparing against the calculated lengths. The Anthropometric Survey of US Army Personnel (ANSUR II) [5] was also used as a third source of reference for limb length measurements. The following measurements were retrieved from the subject before data collection: 34.5 cm from L1 to C7 (thorax), 25.7 cm from C7 Joint Center (JC) to head vertex (neck and head), 36.3 cm from shoulder JC to elbow JC (humerus), 29.5 cm from elbow JC to wrist JC (forearm), and 16.2 cm from clavicle to acromion (clavicle). Of those five, forearm and humerus lengths were calculated using this proposed method to obtain preliminary results. The forearm length after filtering and averaging was calculated to be 37.6 cm. This is a 28% overestimation from the measured forearm length (29.5 cm). The humerus length after filtering and averaging was calculated to be 47.8 cm. This is a 31% difference from the measured subject length (36.3 cm). Sources of error include imperfect isolated motion (method currently expects that motion should be perfectly circular in a 2D plane, include no rotation of the IMU, and be relatively smooth; a more secure IMU attachment method will help), unrefined filter techniques (removed highest and lowest values with 20% high and low pass filters and no smoothing filters), arbitrary removal of stopped or near stopped data (kept data for only a short range before and after the angular velocity peaking), and a more representative method for removing gravitational acceleration is needed (current method is to zero all accelerations against a baseline taken just before the isolated motion which does not account for the gravitational acceleration changed due to IMU rotation during movement). Addressing these error sources will improve the accuracy of the limb length calculation. Next steps include creating a method for whole-body scaling estimation using individual limb scale factors. Continued pursuit of these techniques is expected to enable acquiring anthropometric information using only IMUs in real-time.

E. K. Marecki↗

Polarization Imaging for International Safeguards (FY2019)

A polarization imaging camera, Salsa (Bossa Nova Technologies) was evaluated for use in nuclear safeguards inspection with a focus on swipe sampling. The camera and supporting electronics and software determine the full Stokes parameters for the entire image field. The camera can be used for real-time video or still images. Stokes parameters S0, S1, S2, and S3 can be recorded for each pixel and exported for post processing. This study compared color photography to polarization imaging for powders on many surfaces under ambient lighting. False color images can be created from the Stokes parameters directly from the vendor software to highlight the various polarization states. In most cases, linear polarization showed the greatest effects. The polarization images are easy to collect and very sensitive to surfaces and textures. Fine powders are highlighted in the images, and particle size and refractive index effects were noticed. The images are not affected by ambient lighting (angle, or intensity). Lens choice is key and may require expert knowledge. Very small deposits of 1 µm particles were difficult to image using the standard video lens. General dirt on smooth surfaces and handprints are easily documented as well as powders on textured painted surfaces. Scratches on metal surfaces can be readily separated from other image features. The camera may be useful for tamper indication as surface damage is easy to discern and ambient lighting is not a concern.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative measurements of Jupiter, Saturn, their rings and satellites made from Voyager imaging data

The Voyager spacecraft cameras use selenium-sulfur slow scan vidicons to convert focused optical images into sensible electrical signals. The vidicon-generated data thus obtained are the basis of measurements of much greater precision than was previously possible, in virtue of their superior linearity, geometric fidelity, and the use of in-flight calibration. Attention is given to positional, radiometric, and dynamical measurements conducted on the basis of vidicon data for the Saturn rings, the Saturn satellites, and the Jupiter atmosphere.

Collins, S. A.↗

A Planar Two-Dimensional Superconducting Bolometer Array for the Green Bank Telescope

In order to provide high sensitivity rapid imaging at 3.3mm (90GHz) for the Green Bank Telescope - the world's largest steerable aperture - a camera is being built by the University of Pennsylvania, NASA/GSFC, and NRAO. The heart of this camera is an 8x8 close-packed, Nyquist-sampled detector array. We have designed and are fabricating a functional superconducting bolometer array system using a monolithic planar architecture. Read out by SQUID multiplexers, the superconducting transition edge sensors will provide fast, linear, sensitive response for high performance imaging. This will provide the first ever superconducting bolometer array on a facility instrument.

Benford, Dominic↗

A technique for constructing spectral reflectance curves from Viking lander camera multispectral data

A technique for evaluating the construction of spectral reflectance curves from multispectral data obtained with the Viking lander cameras is presented. The multispectral data is limited to 6 channels in the wave-length range 0.4 to 1.1 microns, and several of the channels suffer from appreciable out-of-band response. The technique represents the estimated reflectance curves as a linear combination of known basic functions with coefficients determined to minimize the error in the representation, and it permits all channels, with and without out-of-band response, to contribute equally valid information. The technique is evaluated for known spectral reflectance curves of 8 materials felt likely to be present on the Martian surface. The technique provides an essentially exact fit if the the reflectance curve has no pronounced maxima and minima. Even if the curve has pronounced maxima and minima, the fit is good and reveals the most dominant features. Since only 6 samples are available some short period features are lost. This loss is almost certainly due to undersampling rather than out-of-band channel response.

Park, S. K.↗

Correction for Neutral Pressure-Driven Signal in Radiated Power Measurements on Proto-MPEX

A pinhole camera using four-channel resistive bolometers was designed and implemented on the Prototype Material Plasma Exposure eXperiment (Proto-MPEX) to measure the plasma radiated power. Quantification of the radiated power is required for comprehensive power balance assessments but faces unique challenges on linear plasma devices due to weak absolute signal, compared to typical use in toroidal fusion plasmas, and high neutral pressure changes. Around 1 mTorr, the pressure-driven signal contribution was shown to overwhelm the radiated power signal in Proto-MPEX, found to be ~3 μW . Since the pressure-driven signals could not be predicted from first principle arguments, the signals were corrected using empirical models that take two experimental pressure measurements and the raw bolometer signal to reveal the radiated power signals. Four “gas-only” Proto-MPEX shots were taken, without the radio frequency (rf) plasma discharge, to train, optimize, and validate empirical models. The data included two pressure measurements at different locations along with the bolometer signal. Multiple models were tested; partial least-squares regression with a cross correlation method to account for the time offset in the pressure measurements provided the best combination of accuracy and stability. The model was validated to have a modeling error of 0.0036 V, which was lower than 10% of the expected radiated power signal. The model was tested on a different “gas-only” shot with a complete time-series data. For plasma operation shots, the corrected bolometer measurements were compared with an absolute extreme ultraviolet photodiode measurement and similarities and differences are discussed.

Lee, Seungsup↗

A quasi-static method for determining the characteristics of a motion capture camera system in a "split-volume" configuration

The purpose of this study was to determine the accuracy, repeatability and resolution of a six-camera Motion Analysis system in a vertical split-volume configuration using a unique quasi-static methodology. The position of a reflective marker was recorded while it was moved quasi-statically over a range of 2.54 mm (0.100 inches) via a linearly-translating table. The table was placed at five different heights to cover both sub-volumes and the overlapping region. Data analysis showed that accuracy, repeatability and resolution values were consistent across all regions of the split-volume, including the overlapping section.

NASA Center JSC↗

Linear Covariance Analysis For Proximity Operations Around Asteroid 2008 EV5

The NASA initiative to collect an asteroid the Asteroid Robotic Redirect Mission (ARRM) is currently investigating the option of retrieving a boulder off an asteroid, demonstrating planetary defense with an enhanced gravity tractor technique and returning it to a lunar orbit. Techniques for accomplishing this are being investigated by the Satellite Servicing Capabilities Office (SSOO) and NASA GSFC in colloboration with JPL, NASA, JSC, LaRC, and Draper Laboratories Inc. Two critical phases of the mission are the descent to the boulder and the Enhanced Gravity Tractor-enhanced gravity tractor demonstration. A linear covariance analysis was done for these phases to assess the feasibility of these concepts with the proposed design of the sensor and actuaor suite of the Asteroid Redirect Vehicle (ARV). The sensor suite for this analysis will include a wide field of view camera, Lidar, and a MMU. The proposed asteroid of interest is currently the C-type asteroid 2008 EV5, a carbonaceous chondrite that is of high interest to the scientific community. This paper will present an overview of the analysis discuss sensor and actuator models and address the feasibility of descending to the boulder within the requirements as the feasibility of maintaining the halo orbit in order to demonstrate the Enhanced Gravity Tractor-enhanced gravity tractory technique.

Guidance↗

Mariner 9 photometric observations of Mars from November 1971 through March 1972

The large quantity of Mariner 9 television pictures taken at phase angles ranging up to twice those accessible from earth has been used to describe integrated photometric properties of Mars. Although frame-to-frame variations emphasize the shortcomings of vidicon cameras when used in a photometric mode, statistical trends have yielded data comparable with earth-based observations. Analysis of atmospheric parameters over a period of changing opacity - November 1971 through March 1972 - has provided time-varying optical depths and light-scattering information. Linear function characterization of the Mars reflectance is clearly discrepant at large incidence or emission angles and at phase angles greater than 40 deg.

Thorpe, T. E.↗

Morphological Evolution of Directional Solidification Interfaces in Microgravity: An Analysis of Model Experiments Performed on the International Space Station

A series of experiments performed using the Pore Formation and Mobility Investigation (PFMI) apparatus within the glovebox facility (GBX) on board the International Space Station (ISS) has provided video images of the morphological evolution of a three-dimensional interface in a diffusion controlled regime. The experimental samples were prepared on ground by filling glass tubes, 1 cm ID and approximately 30 cm in length, with "alloys" of succinonitrile (SCN) and water in an atmosphere of nitrogen at 450 millibar pressure. The compositions of the samples processed and analyzed are 0.25,0.5 and 1.0 wt% water. Experimental processing parameters of temperature gradient and translation speed, as well as camera settings, were remotely monitored and manipulated from the ground Telescience Center (TSC) at the Marshall !3pace Flight Center. During the experiments, the sample was first subjected to a unidirectional melt back, generally at 10 microns per second, with a constant temperature gradient ahead of the melting interface. Following the melt back, the interface was allowed to stabilize before translation is initiated. The temperatures in the sample were monitored by six in situ thermocouples and the position is monitored by an optical linear encoder. For the experiments performed and analyzed, the gradients ranged from 2.5 - 3.3 K/mm and the initial pulling velocities ranged from 0.7 micron per second to 1 micron per second with subsequent transition velocities of up to 100 microns per second. The data provided by the PFMI for analysis includes near-real-time (NRT) video captured on the ground during the experiment runs, ISS Video Tape Recorder (VTR) data dumped from the VTR at the end of the experiment run and recorded on the ground, telemetry data including temperature and position measurements, and limited flight HI-8 tapes in 2 camera views of experiment runs for which tapes have been returned to the investigators from ISS. Because of limited down mass from the ISS, the majority of the initial analysis has been performed using the NRT and VTR video data but will be supplemented with the HI-8 video as it becomes available. hardware and procedures required to prepare samples for correlation to flight samples is described. Using this ground-based system, a series of experiments have been performed for direct comparison with the flight data. The results of these comparisons as well as implications to future microgravity experiments are presented and discussed. A ground-based thin-sample directional solidification system as well as all associated

Strutzenberg, Louise L.↗