Search NASA⌕ Search

SEARCH · Search NASA

Results for “loading models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Software Quality Assurance Plan ANSYS LSDYNA Version 2023R1

ANSYS Inc. develops and markets engineering simulation software and services used in the aerospace, automotive, manufacturing, electronics, biomedical, energy, defense, and many other industries. ANSYS is dedicated to engineering simulation and is the world’s leading software provider. ANSYS was founded in 1970 and is headquartered in Canonsburg, Pennsylvania. ANSYS provides an engineering analysis tool combining structural, thermal, computational fluid dynamics, acoustic and electromagnetic simulation capabilities. ANSYS LS-DYNA is the most used explicit simulation program capable of simulating the response of materials to short periods of severe loading. Its many elements, contact formulations, material models, and other controls can be used to simulate complex models with control over all the details of the problem. ANSYS LS-DYNA has a vast array of capabilities to simulate extreme deformation problems using its explicit solver. Engineers can tackle simulations involving material failure and look at how the failure progresses through a part or through a system. Models with large amounts of parts or surfaces interacting with each other are also easily handled, and the interactions and load passing between complex behaviors are modeled accurately. Using computers with higher numbers of CPU cores can drastically reduce solution times. In addition, many consulting firms and hundreds of universities use ANSYS for analysis, research, and educational purposes. ANSYS is recognized worldwide as one of the most widely used and capable programs of its type. ANSYS has successfully passed over 100 customer quality system audits against American Society of Mechanical Engineers (ASME) NQA-1 and 10 CFR Part 50, Appendix B, since the company was founded, over 60 of which have been since 1997. ANSYS has successfully passed over 100 International Organization for Standardization (ISO) 9001 assessments. ANSYS design analysis software is the first created within a quality system with ISO 9001 certification, which is the internationally accepted quality standard. Product development, testing, maintenance, and support processes also meet the US Nuclear Regulatory Commission’s (NRC’s) quality requirements, as they have for nearly four decades. ANSYS staff perform more than 60,000 software verification tests before releasing each new product. ASME NQA-1-2012 (Subpart 2.7 is specific to software) is the industry- and NRC-accepted approach (consensus standard) for meeting 10 CFR Part 50, Appendix B, requirements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Robust Restoration From Cyber-Physical Attacks in Active Distribution Grids With Grid-Edge IBRs

The inverter-based resources (IBRs) have enabled the integration of renewable energy at the grid edge with enhanced control capabilities to support the reliable operation of power grids. Different control frameworks, such as hierarchical or distributed architecture, have been proposed with the expansion of cyber networks for real-time monitoring and control. This evolution of critical infrastructure into cyber-physical systems also brings more vulnerabilities for the broadened attack surfaces, and significantly increases the possibility of physical system failures or outages caused by cyberattacks. Among tremendous efforts in the defense-in-depth approach, it remains challenging to provide prompt detection and accurate location of attack entry points or paths. Therefore, the prevailing restoration framework may struggle to fully consider the cyber-physical interdependence, successfully isolate the compromised cyber and physical components, and safely recover the systems without the potential risks leading to secondary outages. This paper is motivated to develop a cyber-physical restoration framework for distribution grids to recover from cyber attacks by harnessing grid-edge IBRs. The framework is first built on the operational guidelines of IBRs considering the compromised cyber layer. Then, an ambiguity set is established to represent the uncertainty of attack scenarios and their possibility levels. Next, a distributionally robust optimization model is developed to provide the optimal load restoration strategy across all scenarios. The effectiveness of the proposed model is demonstrated through various use cases on the modified IEEE 13-node and 123-node test systems. Finally, simulation results demonstrate the effectiveness and advancement of developed post-attack restoration strategies.

Cybersecurity↗

Phase transformation kinetics model for metals

We develop a new model for phase transformation kinetics in metals by generalizing the Levitas–Preston (LP) phase field model of martensite phase transformations (see Levitas and Preston (2002a,b) and Levitas et al. (2003)) to arbitrary pressure. Furthermore, we account for and track: the interface speed of the pressure-driven phase transformation, properties of critical nuclei, as well as nucleation at grain sites and on dislocations and homogeneous nucleation. The volume fraction evolution of each phase is described by employing KJMA (Kolmogorov, 1937; Johnson and Mehl, 1939; Avrami, 1939, 1940, 1941) kinetic theory. We then test our new model for iron under ramp loading conditions and compare our predictions for the α → ϵ iron phase transition to experimental data of Smith et al. (2013). In conclusion, more than one combination of material and model parameters (such as dislocation density and interface speed) led to good agreement of our simulations to the experimental data, thus highlighting the importance of having accurate microstructure data for the sample under consideration.

36 MATERIALS SCIENCE↗

Measurement of Wind Loading on Heliostats at the Crescent Dunes Power Plant: An Overview

The cost of solar collectors constitutes almost one third of the total cost of a CSP plant. One of the ongoing challenges in the design of these collectors is wind loading on mirrors, support structures, and drives. A particular challenge is dynamic wind loading, caused by the turbulent wind flow. To date, the design of solar collector structures has relied on wind tunnel experiments and numerical simulations that do not entirely capture the dynamic effects observed at scale. The CSP industry has shown increased interest in validating the idealized assumptions with measurements obtained in operational settings to improve wind load assumptions and increase reliability and cost-efficiency of the collector design. Further, performance models need realistic assumptions about wind loading and its impact on optical performance. In a parabolic trough field campaign, NREL successfully collected a wealth of long-term, high-resolution wind and loads data [2], that are publicly available and that can be used for the above-mentioned purposes. Heliostats are impacted differently by wind than parabolic troughs, due to their different shape, size, and field layout. To study the impact of wind and turbulence on heliostats, we initiated another field campaign in an operational power- tower plant, Crescent Dunes, in Nevada, USA. In this work, we present an overview of the measurements, first results, and potential implications of wind driven loads on Heliostats.

concentrated solar power↗

Statistical Estimation of EV Driver Charging Behavior and Influential Factors

INL received data collected via telematics from battery electric vehicles (BEVs), and these vehicles were owned by retail customers who had entered into a telematics user agreement. The goal of analyzing these data was to develop mathematical models to characterize how different sets of BEV drivers use charging infrastructure at home and away from home (i.e., public charging) and quantify how various factors influence BEV drivers’ decision to charge and use available infrastructure. The data used in this analysis are unique because they provide real world BEV driving and charging behavior at the individual driving and parking event level. In this study we seek to leverage this data to quantify BEV charging and driving metrics to help inform models that predict quantities like the specific times when loads are imposed on the electrical grid due to BEV charging. Most models that have been developed to predict electrical grid load due to BEV charging, use simulations of BEV driving events and rely on assumptions such as every vehicle charges every night. Using a statistical modelling framework, we seek to investigate BEV charging behavior and quantitatively assess these common assumptions of BEV charging behavior.

33 - ADVANCED PROPULSION SYSTEMS↗

Spatially Resolved Domicile Charging Demands for Light-, Medium-, and Heavy-Duty Electric Vehicles in Virginia

The use of plug-in electric vehicles (PEVs) and resulting grid impacts are likely to grow rapidly, and evaluation of optimal smart charge management and grid integration strategies is warranted now. Evaluating distribution grid impacts requires fine-grained models of PEV operations to estimate charging loads across diverse vehicles at high spatial resolution. We propose such a model and consider a high-electrification scenario in Richmond and Newport News, Virginia. Our framework considers four categories of vehicle that are amenable to early aggressive electrification: light-duty passenger vehicles (LDV), trucks and vans with a focus on delivery or other local operations, school buses, and transit buses. These vehicles have a relatively consistent domicile, reducing the need for public charging infrastructure rollout to electrify. We apply a recent LDV model and propose new models for each vocation of medium- and heavy-duty vehicle, leveraging telematics data. We demonstrate our framework in Virginia and find energy demands in the region may total 15 GWh day, with most consumed by LDV. However, considering power demand at high spatial resolution reveals a different trend: LDVs have relatively small peak loads at specific sites (peak site demand around 800 kW) compared to average and high demand medium- and heavy-duty vehicle charging sites (peak site demand around 6,000 kW at a transit bus depot, 1,500 kW at a local freight hub, and 1,000 kW at a school). Our framework yields insights on the relative impacts of each vocation and enables future work to tailor grid integration strategies to each vehicle category.

33 ADVANCED PROPULSION SYSTEMS↗

Optimizing Power Line Undergrounding Decisions under Varying Wildfire Risk and Weather Scenarios

Abstract—The threat of wildfire ignitions from electric power equipment has led utilities to increasingly turn to preemptive power shutoffs, which, while effective in reducing grid-induced wildfire risk, can cause significant load loss. Undergrounding power lines is an alternative strategy for preventing grid-induced wildfires. However, undergrounding lines is costly, so an efficient undergrounding plan must balance reductions in wildfire risk and load loss with the cost of undergrounding lines. We propose a robust optimization model to identify which power lines to underground to maximize load served while limiting wildfire risk across a range of wildfire risk and weather scenarios. Since solving this problem may be computationally heavy for large power grids and many operating scenarios, we present a delayed constraint generation algorithm to iteratively add scenarios until an optimal solution is found. We evaluate the performance of this framework on the RTS-GMLC with scenarios representing a year of operating conditions and compare it with a stochastic programming formulation. Our results indicate that our undergrounding model is successful in reducing load shed and risk compared to baseline cases in which no mitigation action is taken and only power shutoffs are implemented (no undergrounding). The robust formulation also reduces more load shed than the stochastic formulation in the most extreme scenarios. Index Terms—grid resilience, optimization, transmission systems, underground power lines, wildfire risk.

Taylor, S. [Department of Electrical and Computer ↗

A method for modeling battery-temperature-aware EV power profiles utilizing Next-Gen Profile data

With the expected increase in the number of electric vehicles (EVs) on the road in the coming years, it is important that analysis tools are capable of modeling and predicting the expected load on the power grid due to both individual EV charging sessions as well as large populations of vehicles. To do this accurately, the power profile of an EV charge session must be accurately modeled, including for scenarios where the temperature is above or below the ideal, and also take into account the nuances of manufacturer charging preferences. This paper introduces a method that utilizes the data in the Next-Gen Profile (NGP) data collection project to build a model of EV charging that takes into account the variations in charging power that occur due to off-nominal battery temperature and manufacturer preferences that limit power due to cold temperatures or high battery state-of-charge.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Brittle failure analysis and modeling of high-burnup PWR fuel cladding alloys

The aim of this research is the development of methods for predicting mechanical behavior and identification of limiting conditions to prevent brittle failure of high-burnup (HBU) pressure water reactor (PWR) fuel cladding alloys. A finite element (FE) model of the ring compression test (RCT) was created to analyze the failure behavior of zirconium-based alloys with radial hydrides during the RCT. An elastic-plastic material model describes the zirconium alloy. The stress-strain curve needed for the elastic-plastic material model was derived by inverse finite element analyses. Cohesive zone modeling is used to reproduce sudden load drops during RCT loading. Based on the failure mechanism in non-irradiated ZIRLO (R) claddings, a micro-mechanical model was developed that distinguishes between brittle failure along hydrides and ductile failure of the zirconium matrix. Two different cohesive laws representing these types of failure are present in the same cohesive interface. The key differences between these constitutive laws are the cohesive strength, the stress at which damage initiates, and the cohesive energy, which is the damage energy dissipated by the cohesive zone. Statistically generated matrix-hydride distributions were mapped onto the cohesive elements and simulations with focus on the first load drop were performed. Computational results are in good agreement with the RCT results conducted on high-burnup M5 (R) samples. It could be shown that crack initiation and propagation strongly depend on the specific configuration of hydrides and matrix material in the fracture area.

Simbruner, Kai↗

Hourly Electricity Demand Projections for Eight Combined Climate and Socioeconomic Scenarios

This dataset contains 40 years (1980-2019) of simulated historical hourly electricity demand (i.e., loads) and 80 years (2020-2099) of projected hourly loads for 54 Balancing Authorities (BAs) and 48 states plus the District of Columbia. Details about the scenarios and variables included in this dataset are in the readme.pdf file. The two primary models that created the dataset are a version of the Global Change Analysis Model with detailed sectoral resolution over the United States (GCAM-USA) and the Total ELectricity Loads (TELL) model. Links to the model source code and workflow for deriving the dataset are provided in an accompanying meta-repository: https://github.com/IMMM-SFA/burleyson-etal_2024_applied_energy. Projections are for four future climate scenarios that represent combinations of Representative Concentration Pathways (RCPs) 4.5 and 8.5 combined with two levels of climate model sensitivities: rcp45cooler, rcp45hotter, rcp85cooler, and rcp85hotter. The four climate scenarios are crossed with Shared Socioeconomic Pathways (SSPs) 3 and 5 to yield eight different future load projections: rcp45cooler_ssp3, rcp45cooler_ssp5, rcp45hotter_ssp3, rcp45hotter_ssp5, rcp85cooler_ssp3, rcp85cooler_ssp5, rcp85hotter_ssp3, and rcp85hotter_ssp5. The climate scenarios are from the IM3 Thermodynamic Global Warming (TGW) dataset which is linked below in the related metadata. The related metadata also contains links to a repository containing the raw GCAM-USA output files.

Climate Change↗

Investigation of Main Bearing Fatigue Estimate Sensitivity to Synthetic Turbulence Models Using a Novel Drivetrain Model Implemented in OpenFAST

ABSTRACT A coupled medium‐fidelity drivetrain model is developed and implemented in OpenFAST for a 10‐MW land‐based reference turbine. The implementation is verified against a fully coupled multibody wind turbine model, including a detailed drivetrain. The new model can simultaneously and accurately estimate main bearing loads and represent elastic bending of the drivetrain. It has low computational cost and is useful for early design phases, sensitivity analyses and complex systems like wind farms (where computational expense must be expended elsewhere). Here, the model is implemented for a monopile offshore wind turbine and used to investigate the sensitivity of main bearing basic rating life to different synthetic turbulence models. Large‐eddy simulations (LES) targeting stable, neutral, and unstable atmospheric conditions at below‐, near‐ and above‐rated wind speeds are used as a reference. The turbulence models recommended by the International Electrotechnical Commission, the Mann spectral tensor model, and the Kaimal spectral model with exponential coherence are fitted to the LES data. Additionally, a constrained turbulence generator, PyConTurb (short for Python Constrained Turbulence ), based on LES data, is applied in the aero‐hydro‐servo‐elastic simulations. Taking PyConTurb as the baseline, the Kaimal model significantly underestimates fatigue of the downwind main bearing, with between 10% and 40% less damage. The Mann model also underestimates the downwind main bearing fatigue by up to 30%. The upwind main bearing damage is driven by mean loads, and differences between models are less significant, although the trends are similar. Reasons for these discrepancies are investigated and attributed to differences in spatial and temporal variations among the turbulence models.

17 WIND ENERGY↗

Model-Free Control of Grid-Interactive Efficient Buildings Under Communication Time Delays

Grid-interactive efficient buildings (GEBs) have recently been used to enhance the reliability and stability of the electric grid through demand response (DR) programs. However, most existing DR control strategies require accurate modeling of the various building thermostatically controlled loads (TCLs) and are computationally expensive. To address these challenges, a model-free control (MFC)-based strategy has recently been introduced for coordinating and controlling GEBs. MFC is a data-enabled control strategy that is computationally efficient and does not require the analytical models of the various building equipment. In this paper, we numerically investigate the impact of communication time delays on the performance of MFC in maintaining the TCLs' temperatures within the desired comfort levels while meeting the assigned power allocation constraint.

Telsang, Bhagyashri [University of Tennessee, Knox↗

A Transactive Approach for Service Restoration Utilizing Customer Load Flexibility and Grid-Edge Resources

This paper develops a transactive energy system model to restore electricity to customers in an isolated distribution system after an outage. The model engages a variety of customer types -- prosumers, flexible loads, critical/noncritical customers, and distributed generators -- as active participants in the restoration process. Unlike many existing transactive approaches, the proposed model is developed for service restoration and accounts for various customer types and their autonomy and privacy through an iterative approach to determine the optimal market price, while maintaining system-level power flow and voltage constraints. The advantages of the proposed approach are numerically validated on a modified IEEE 123-bus test system.

distributed energy resources↗

A high-resolution pseudo-polygon discrete element model for regional sea ice

Here, this work presents a pseudo-polygon discrete element model for high-resolution sea ice simulations. A scale-invariant bonded particle contact model is proposed to model joints between sea ice floes based on the smeared fracture model and a lattice spring beam model, and the Mohr–Coulomb failure criterion is implemented to represent the shearing failure mechanism of sea ice packings under complex loadings. All mechanical parameters of the bond model can be directly determined from laboratory tests. Validations of the proposed model are made by investigations of mechanical response and failure criteria of field sea ice sheets. Compared with the field observations of sea ice from satellite radar and in situ stress sensors, the proposed model is capable of reproducing the typical constitutive behavior and the Coulomb friction envelope of field sea ice. Finally, the proposed discrete element sea ice model is used to study the effect of loading rates on mechanical behavior including failure strength of regional sea ice.

54 ENVIRONMENTAL SCIENCES↗

Machine learning-enhanced MPC for demand flexibility in small commercial buildings: An experimental study

Small- and medium-sized commercial buildings (SMCBs) represent the majority of U.S. commercial building stock and a significant share of peak electricity demand, yet they often lack centralized building automation systems, representing a significant untapped resource for urban energy management. This infrastructure gap makes advanced control implementation challenging, limiting the potential for widespread demand flexibility. Model Predictive Control (MPC) has shown strong potential for load shifting, peak demand reduction, and cost savings, but its effectiveness is hindered by unmeasured disturbances such as internal heat gains. This paper presents a Hybrid MPC framework that integrates a physics-based gray-box building thermal model, identified using a lumped disturbance (LD) approach, with a machine learning (ML) model for forecasting unmeasured disturbances. The hybrid approach is designed for buildings with multiple individually controlled heat pump and thermostat pairs, common in SMCBs, and aims to optimize coordinated scheduling of multiple heat pumps under dynamic electricity pricing while respecting comfort constraints. The methodology is validated through both simulations of case study buildings and experimental studies at a highly-instrumented test facility. Simulation results show that the Hybrid MPC achieves substantial load shifting and peak demand reduction, approaching the performance of an ideal MPC with perfect disturbance knowledge, and outperforming a conventional MPC without disturbance forecasting. In experiments, the Hybrid MPC reduced daily HVAC energy costs by 8.7%, peak-price time load (load shifting) by 41.7%, and peak demand by 29.2% compared to baseline control, demonstrating comparable benefits to the 11.6% cost savings, 42.9% load shifting, and 23.2% peak reduction of the ideal MPC. These results demonstrate that the proposed hybrid modeling approach can significantly improve MPC performance in real-world SMCB applications without requiring additional disturbance measurements.

Demand Flexibility↗

Reformulating a Gurson-based dynamic damage model and demonstrating improved predictive power and numerical robustness

The original Tepla (TEnsile PLAsticity) ductile damage model, based on the Gurson yield surface, has long been used to model damage evolution and material failure under dynamic loading. Unfortunately, Tepla suffered from mesh sensitivity, numerical instability, and limited predictive capability. Here, we theoretically reformulate Tepla to address these issues. We especially focus on the prediction of porosity, which is the key state variable used for modeling ductile damage, as compared to more easily measured surface velocities, which are at best an indirect measure of damage. Key model changes include separating the viscosity during volumetric void growth from underlying shear strength behavior and switching to an iterative bisection solver. The new Tepla is then calibrated on incipient spall experiments on half-hard copper and tantalum, which demonstrate its ability to simultaneously fit the model to recovered porosity distributions and measured surface velocities, a stringent test. Improved numerical behavior, such as greatly reduced mesh sensitivity, is also shown in those simulations. Finally, the new Tepla model is applied to several high-explosive loaded, sweeping wave experiments, showing the ability of the model to predict behavior on tests with significantly different loading conditions and histories than the calibration data.

36 MATERIALS SCIENCE↗

Positron Beam Loading and Acceleration in the Blowout Regime of a Plasma Wakefield Accelerator

Plasma wakefield acceleration in the nonlinear blowout regime has achieved marked milestones in electron beam acceleration, demonstrating high acceleration gradients and energy efficiency while preserving excellent beam quality. However, this regime is deemed unsuitable for achieving positron acceleration of comparable results, which is vital for future compact electron–positron colliders. In this article, we find that an intense positron beam loaded at the back of beam-driven blowout cavity can self-consistently induce the focusing field and flatten the longitudinal wakefield, leading to stable, high-efficiency, and high-quality positron acceleration. This is achieved through the formation of an on-axis electron filament induced by positron beam load, which shapes the plasma wakefield in a distinct way compared to electron beam load in the blowout regime. Via a nonlinear analytic model and numerical simulations, we explain the novel beam loading effects of the interaction between the on-axis filament and the blowout cavity. High-fidelity simulations show that a high-charge positron beam can be accelerated with >20% energy transfer efficiency, ~1% energy spread, and ~1 mm·mrad normalized emittance, while considerably depleting the energy of the drive beam. The concept can also be extended to simultaneous acceleration of electron and positron beams and high transformer ratio positron acceleration as well. This development offers a new route for the application of plasma wakefield acceleration into particle physics.

Science & Technology - Other Topics↗

Optimal Network Reconfiguration and Scheduling With Hardware-in-the-Loop Validation for Improved Microgrid Resilience

With the increased occurrence of various major extreme weather events, power outages and prompt power system restorations have recently drawn more attention to the resilience and recovery of power systems. From the perspective of a more resilient power delivery at the distribution grid, system restoration using network topology reconfiguration together with optimal scheduling of distributed energy resources are adopted in this paper. The proposed optimization model aims at minimizing the total load shedding cost and other operational costs, in which linearized topological constraints borrowed from graph theory and linearized DistFlow models are respectively used to maintain the radial network topology and power flow balance after system contingencies. To demonstrate the applicability of the proposed strategy, a real-world case study of a networked three-microgrid system in Adjuntas, Puerto Rico, is used with the consideration of different independent/interconnected microgrid scenarios, contingencies, and fairness settings. Furthermore, hardware-in-the-loop testing is conducted for the same three-microgrid network, where the closely matched results with the simulated ones have validated the effectiveness of the proposed restoration strategy, which is now ready to move one step forward towards field deployment. Finally, to test the proposed restoration strategy in a larger networked system, the modified IEEE-33 bus test distribution system is considered, and the results show a more resilient power delivery for critical loads under three and four line outages.

24 POWER TRANSMISSION AND DISTRIBUTION↗