SEARCH · Search NASA
Results for “loop”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
A Divalent Ion Is Crucial in the Structure and Dominant- Negative Function of ID Proteins, a Class of Helix-Loop- Helix Transcription Regulators
Abstract not provided
Magnetic Coupling To A Loop Antenna In Proximity Of Shorted-large Loops
The goal of this report is to explain how to estimate the cable voltage in a changing magnetic field surrounded by a metal structure.
A Comparison of the Environmental Effects of Open-Loop and Closed-Loop Pumped Storage Hydropower
Pumped storage hydropower (PSH) is a type of energy storage that uses the pumping and release of water between two reservoirs at different elevations to store water and generate electricity (Figure ES-1). When demand for electricity is low, a PSH project can use low cost energy to pump water from the lower reservoir to the upper reservoir for storage. When demand for electricity is high, a PSH project can release water from the upper reservoir through a powerhouse to generate electricity. Traditionally, this meant that PSH plants generated power during the day and pumped at night, with modest diurnal or seasonal variation.
Simulations of a Circulating Fluidized Bed Chemical Looping Combustion System Utilizing Gaseous Fuel
Explore the source record for details and available documents.
Inter-loop Optimizations in RAJA using Loop Chains
Explore the source record for details and available documents.
Fermions and loops on graphs. I. Loop calculus for determinant
No abstract prepared.
Systematics of high temperature perturbation theory: The two-loop electron self-energy in QED
In order to investigate the systematics of the loop expansion in high temperature gauge theories beyond the leading order hard thermal loop (HTL) approximation, we calculate the two-loop electron proper self-energy {Sigma} in high temperature QED. The two-loop bubble diagram of {Sigma} contains a linear infrared divergence. Even if regulated with a nonzero photon mass M of order of the Debye mass, this infrared sensitivity implies that the two-loop self-energy contributes terms to the fermion dispersion relation that are comparable to or even larger than the next-to-leading order (NLO) contributions of the one-loop {Sigma}. Additional evidence for the necessity of a systematic restructuring of the loop expansion comes from the explicit gauge-parameter dependence of the fermion damping rate at both one and two loops. The leading terms in the high temperature expansion of the two-loop self-energy for all topologies arise from an explicit hard-soft factorization pattern, in which one of the loop integrals is hard (p{approx_equal}T), nested inside a second loop integral which is soft (0{<=}p < or approx. T for real parts; p{approx_equal}eT for imaginary parts). There are no hard-hard contributions to the two-loop {Sigma} at leading order at high T. Provided the same factorization pattern holds for arbitrary l loops, the NLO high temperature contributions to the electron self-energy come from l-1 hard loops factorized with one soft loop integral. This hard-soft pattern is a necessary condition for the resummation over l to coincide with the one-loop self-energy calculated with HTL dressed propagators and vertices, and to yield the complete NLO correction to {Sigma} at scales {approx}eT, which is both infrared finite and gauge invariant. We employ spectral representations and the Gaudin method for evaluating finite temperature Matsubara sums, which facilitates the analysis of multiloop diagrams at high T.
Report on the completion of long-lead components procurement of new sodium materials test loop
This report provides an update on the completion of long-lead components procurement of new sodium materials test loop. The loop, designated as SMT-3, is a forced-convection sodium loop to be used for the evaluation of sodium compatibility of advanced Alloy 709 with emphasis on long term exposures of tensile, creep, fatigue, creep fatigue, and fracture toughness ASTM-size specimens in support of ASME Code qualification and NRC licensing. The report is a deliverable (Level 4) in FY18 (M4NT-18AN050503013), under the Work Package NT-18AN05050301, “A709 Sodium Compatibility” performed by Argonne National Laboratory (ANL), as part of the Advanced Materials Program for the Advanced Reactor Technology. This work package enables the development of advanced structural materials by providing corrosion, microstructure, and mechanical property data from the standpoint of sodium compatibility of advanced structural alloys. The first sodium loop (SMT-1) with a single tank was constructed in 2011 at ANL and has been in operation for exposure of subsize sheet specimens of advanced alloys at a single temperature. The second sodium loop with dual tanks (SMT-2) was constructed in 2013 and has been in operation for the exposure of subsize sheet specimens of advanced alloys at two different temperatures. The current loop (SMT-3) has been designed to incorporate sufficient chamber capacity to expose a large number of ASTM-size specimens to evaluate the sodium effects on tensile, creep, fatigue, creep-fatigue, and fracture toughness properties, in support of ASME Code Qualification and USNRC Licensing. Three major long lead items were identified: 1) Selection and approval of location for the new loop and installation of the necessary infrastructure, such as transformer, power supply panels, and wiring, that is adequate for the long term operation of the loop, 2) Perform a detailed piping analysis that meets the ANL QA and Safety guidelines as well as complying with ASME Code requirements, and 3) Design and fabrication of the specimen exposure vessels that are capable of at least 42 tensile, creep, and fatigue specimens in each vessel and is compliant and compatible with ASME Code and the piping design analysis. The SMT-3 loop will be located in Building 206 adjacent to the currently operating SMT-2 loop. In addition, we have removed the aged power supply system in Building 206 and installed a new transformer, wiring, and power panels for the new loop. The preliminary loop design was sent to an outside vendor for a detailed piping analysis, to ensure compliance with the ASME Code guidelines. The piping design was completed in FY2017. The construction of components such as cold trap, economizers, piping arrangement etc. will be performed in the central shops at ANL. About 150 liters of sodium for the loop will be procured in early FY2018. The loop system is designed to circulate sodium through the sample tanks and he associated loop without an operator for an extended period of time. With the three sodium loops (i.e., single-tank, dual-tank and four–tank), materials can be tested at different sodium temperatures, and large tensile, creep, fatigue, creep-fatigue, and fracture toughness specimens can be exposed to sodium for extended periods of time and generate data on mechanical properties in support of ASME Code Qualification and USNRC Licensing of advanced Alloy 709 for use as a structural material in SFRs.
Replacing Arginine 33 for Alanine in the Hemophore HasA from Pseudomonas aeruginosa Causes Closure of the H32 Loop in the Apo-Protein
Previous characterization of hemophores from Serratia marcescens (HasAs), Pseudomonas aeruginosa (HasAp), and Yersinia pestis (HasA yp ) showed that hemin binds between two loops, where it is axially coordinated by H32 and Y75. The Y75 loop is structurally conserved in all three hemophores and harbors conserved ligand Y75. The other loop contains H32 in HasAs and HasAp, but a noncoordinating Q32 in HasA yp . The H32 loop in apo-HasAs and apo-HasAp is in an open conformation, which places H32 about 30 Å from the hemin-binding site. Hence, hemin binding onto the Y75 loop of HasAs or HasAp triggers a large relocation of the H32 loop from an open- to a closed-loop conformation and enables coordination of the hemin-iron by H32. In comparison, the Q32 loop in apo-HasA yp is in the closed conformation, and hemin binding occurs with minimal reorganization and without coordinative interactions with the Q32 loop. Studies in crystallo and in solution have established that the open H32 loop in apo-HasAp and apo-HasAs is well structured and minimally affected by conformational dynamics. In this study we address the intriguing issue of the stability of the H32 loop in apo-HasAp and how hemin binding triggers its relocation. Specifically, we address this question with a combination of NMR spectroscopy, X-ray crystallography, and molecular dynamics simulations and find that R33 is critical to the stability of the open H32 loop. Replacing R33 with A causes the H32 loop in R33A apo-HasAp to adopt a conformation similar to that of holo-HasAp. Finally, stopped-flow absorption and resonance Raman analyses of hemin binding to apo-R33A HasAp indicate that the closed H32 loop slows down the insertion of the heme inside the binding pocket, presumably as it obstructs access to the hydrophobic platform on the Y75 loop, but accelerates the completion of the heme iron coordination.
Gravitational steady states of solar coronal loops
Coronal loops on the surface of the sun appear to consist of curved, plasma-confining magnetic flux tubes or “ropes,” anchored at both ends in the photosphere. Toroidal loops carrying current are inherently unstable to expansion in the major radius due to toroidal-curvature-induced imbalances in the magnetic and plasma pressures. An ideal MHD analysis of a simple isolated loop with density and pressure higher than the surrounding corona, based on the theory of magnetically confined toroidal plasmas, shows that the radial force balance depends on the loop internal structure and varies over parameter space. It provides a unified picture of simple loop steady states in terms of the plasma beta β o , the inverse aspect ratio ϵ = a/R o , and the MHD gravitational parameter $\hat{G}$ ≡ ga/v$2\atop{A}$, all at the top of the loop, where g is the acceleration due to gravity, a the average minor radius, and v A the shear Alfvén velocity. In the high and low beta tokamak orderings, β o = 2n o T/(B$2\atop{0}$/2μ o ) ~ ϵ 1 and ϵ 2 , that fit many loops, the solar gravity can sustain nonaxisymmetric steady states at $\hat{G}$ ~ ϵβ o that represent the maximum stable height. At smaller \hat{G} ≤ ϵ 2 β o , the loop is axisymmetric to leading order and stabilized primarily by the two fixed loop ends. Very low beta, nearly force-free, steady states with β o ~ ϵ 3 may also exist, with or without gravity, depending on higher order effects. The thin coronal loops commonly observed in solar active regions have ϵ ≃ 0.02 and fit the high beta steady states. $\hat{G}$ increases with loop height. Fatter loops in active regions that form along magnetic neutral lines and may lead to solar flares and Coronal Mass Ejections have ϵ ≃ 0.1–0.2 and may fit the low beta ordering. Larger loops tend to have $\hat{G}$ > ϵβ o and be unstable to radial expansion because the exponential hydrostatic reduction in the density at the loop-top reduces the gravitational force -ρ$\hat{G}\hat{R}$ below the level that balances expansion, also in agreement with the observation that most sufficiently large loops grow.
Environmental Impacts of Closed-Loop Pumped Storage Hydropower
The goal of this report is to help license applicants, resource agencies, and other members of the hydropower community involved in closed-loop pumped storage hydropower permitting and licensing process, focus the scope of environmental reviews, and more quickly identify impacts with project nexus and potential mitigation measures for these impacts. Pumped storage hydropower (PSH) is an energy storage technology that uses energy to pump water up from a lower reservoir to an upper reservoir where water is stored until electricity is needed and the water is released to a lower reservoir passing through turbines. Closed-loop PSH—PSH that is not continuously connected to a naturally flowing water feature—is one of the lowest greenhouse gas emitting energy storage technologies and is therefore a critical part of the transition to renewable energy (Simon et al. 2023). Proposals for closed-loop PSH facilities in the United States currently account for more than 40% of original licenses and 99% of potential generation capacity in the Federal Energy Regulatory Commission (FERC) hydropower licensing pipeline (Johnson et al. 2023). While closed-loop PSH facilities can have lower environmental impacts than open-loop PSH facilities, no closed-loop facilities have been constructed in the United States to enable direct accounting of project impacts and efficacy of mitigations. Many proposals for closed-loop PSH submitted to FERC are abandoned early in the permitting and licensing process prior to license applications and environmental assessments, so there is little documentation describing potential project impacts and proposed mitigations. The newness of closed-loop PSH proposals in the United States may mean that tribal, federal, and state agencies with authorities for cultural and natural resources protection and management involved in the FERC licensing process may not have experience with closed-loop PSH regulation. Moreover, many proposed closed-loop PSH facilities are in areas that do not have high concentrations of conventional hydropower, so these agencies may also be unfamiliar with the FERC hydropower licensing process. The goal of this report is to help license applicants, resource agencies, and other members of the hydropower community focus the scope of environmental review for the closed-loop PSH development, licensing, and federal authorization process enabling quicker identification of potential impacts, mitigations, and situations where mitigation may not be possible. We found that environmental impacts of closed-loop PSH are highly site-specific, and generalizations about the types of environmental impacts across closed-loop PSH projects are difficult to make. Environmental impacts of closed-loop PSH are like those for open-loop PSH with a few exceptions including water sourcing, which can lead to delays and contention due to potential complexities with water rights, impacts to aquatic resources, and greenhouse gas emission potential. Cultural resource impacts were commonly reported in National Environmental Policy Act (NEPA) documents reviewed and discussed in interviews, but in many cases such impacts cannot be mitigated.
Hybrid Combustion-Gasification Chemical Looping
For the past several years Alstom Power Inc. (Alstom), a leading world-wide power system manufacturer and supplier, has been in the initial stages of developing an entirely new, ultra-clean, low cost, high efficiency power plant for the global power market. This new power plant concept is based on a hybrid combustion-gasification process utilizing high temperature chemical and thermal looping technology The process consists of the oxidation, reduction, carbonation, and calcination of calcium-based compounds, which chemically react with coal, biomass, or opportunity fuels in two chemical loops and one thermal loop. The chemical and thermal looping technology can be alternatively configured as (i) a combustion-based steam power plant with CO{sub 2} capture, (ii) a hybrid combustion-gasification process producing a syngas for gas turbines or fuel cells, or (iii) an integrated hybrid combustion-gasification process producing hydrogen for gas turbines, fuel cells or other hydrogen based applications while also producing a separate stream of CO{sub 2} for use or sequestration. In its most advanced configuration, this new concept offers the promise to become the technology link from today's Rankine cycle steam power plants to tomorrow's advanced energy plants. The objective of this work is to develop and verify the high temperature chemical and thermal looping process concept at a small-scale pilot facility in order to enable AL to design, construct and demonstrate a pre-commercial, prototype version of this advanced system. In support of this objective, Alstom and DOE started a multi-year program, under this contract. Before the contract started, in a preliminary phase (Phase 0) Alstom funded and built the required small-scale pilot facility (Process Development Unit, PDU) at its Power Plant Laboratories in Windsor, Connecticut. Construction was completed in calendar year 2003. The objective for Phase I was to develop the indirect combustion loop with CO{sub 2} separation, and also syngas production from coal with the calcium sulfide (CaS)/calcium sulfate (CaSO{sub 4}) loop utilizing the PDU facility. The results of Phase I were reported in Reference 1, 'Hybrid Combustion-Gasification Chemical Looping Coal Power Development Technology Development Phase I Report' The objective for Phase II was to develop the carbonate loop--lime (CaO)/calcium carbonate (CaCO{sub 3}) loop, integrate it with the gasification loop from Phase I, and ultimately demonstrate the feasibility of hydrogen production from the combined loops. The results of this program were reported in Reference 3, 'Hybrid Combustion-Gasification Chemical Looping Coal Power Development Technology Development Phase II Report'. The objective of Phase III is to operate the pilot plant to obtain enough engineering information to design a prototype of the commercial Chemical Looping concept. The activities include modifications to the Phase II Chemical Looping PDU, solids transportation studies, control and instrumentation studies and additional cold flow modeling. The deliverable is a report making recommendations for preliminary design guidelines for the prototype plant, results from the pilot plant testing and an update of the commercial plant economic estimates.
THE CORONAL LOOP INVENTORY PROJECT: EXPANDED ANALYSIS AND RESULTS
We have expanded upon earlier work that investigates the relative importance of coronal loops with isothermal versus multithermal cross-field temperature distributions. These results are important for determining if loops have substructure in the form of unresolved magnetic strands. We have increased the number of loops targeted for temperature analysis from 19 to 207 with the addition of 188 new loops from multiple regions. We selected all loop segments visible in the 171 Å images of the Atmospheric Imaging Assembly (AIA) that had a clean background. Eighty-six of the new loops were rejected because they could not be reliably separated from the background in other AIA filters. Sixty-one loops required multithermal models to reproduce the observations. Twenty-eight loops were effectively isothermal, that is, the plasma emission to which AIA is sensitive could not be distinguished from isothermal emission, within uncertainties. Ten loops were isothermal. Also, part of our inventory was one small flaring loop, one very cool loop whose temperature distribution could not be constrained by the AIA data, and one loop with inconclusive results. Our survey can confirm an unexpected result from the pilot study: we found no isothermal loop segments where we could properly use the 171-to-193 ratio method, which would be similar to the analysis done for many loops observed with TRACE and EIT. We recommend caution to observers who assume the loop plasma is isothermal, and hope that these results will influence the direction of coronal heating models and the effort modelers spend on various heating scenarios.
Formation of large loop-hydrogen complexes and related effects on mechanical properties of Zirconium investigated with molecular dynamics method
Here, using molecular dynamics (MD) method, interaction between hydrogen (H) atoms and interstitial or vacancy dislocation loops in Zr is extensively studied. The results show that the binding of hydrogen atoms to dislocation loops is anisotropic (attractive or repulsive), depending on the position of the hydrogen atoms with respect to the loop’s core. The anisotropy is governed by excess volume and stress field induced by the loop. For a 1/3[$2\bar1$$\bar1$$0$] interstitial dislocation loop, hydrogen atoms preferentially segregate near the outside of the loop and close to the decomposition knots of the loop. While for a 1/3[$2\bar1$$\bar1$$0$] or 1/6[$20$$\bar2$$3$] vacancy loop, hydrogen atoms prefer to segregate near the inside of the loop. The present work indicates large loop-hydrogen complexes could form in Zr. The binding of hydrogen to loops is stable up to 600 K, while dissociation is observed at 900 K. Formation of loop-hydrogen complexes affect the activation of slip system, resulting in higher yield stress of Zr. The effect increases with the increasing ratio of H to vacancies or interstitials in the vacancy or interstitial loops. The results imply the effects of large loop-hydrogen complexes should be considered to fully understand radiation damage in Zr.
Livermore Compiler Analysis Loop Suite
LCALS is designed to evaluate compiler optimizations and performance of a variety of loop kernels and loop traversal software constructs. Some of the loop kernels are pulled directly from "Livermore Loops Coded in C", developed at LLNL (see item 11 below for details of earlier code versions). The older suites were used to evaluate floating-point performances of hardware platforms prior to porting larger application codes. The LCALS suite is geared toward assissing C++ compiler optimizations and platform performance related to SIMD vectorization, OpenMP threading, and advanced C++ language features. LCALS contains 20 of 24 loop kernels from the older Livermore Loop suites, plus various others representative of loops found in current production appkication codes at LLNL. The latter loops emphasize more diverse loop constructs and data access patterns than the others, such as multi-dimensional difference stencils. The loops are included in a configurable framework, which allows control of compilation, loop sampling for execution timing, which loops are run and their lengths. It generates timing statistics for analysis and comparing variants of individual loops. Also, it is easy to add loops to the suite as desired.
Robust multi‐loop control of a floating wind turbine
Abstract A principal challenge facing the control of floating offshore wind turbines (FOWTs) is the problem of instability, or “negative damping,” when using blade pitch feedback to control generator speed. This closed‐loop instability can be attributed to non‐minimum phase zeros in the transfer function from blade pitch to generator speed. Standard approaches to improving stability and performance include robust tuning of control gains and introducing multiple feedback loops to respond to platform motion. Combining these approaches is nontrivial because multiple control loops complicate the impact of coupling in the system dynamics. The single‐loop approach to analyzing stability robustness neglects inter‐loop coupling, while a simplistic multi‐loop approach is highly sensitive to dimensional scaling and overestimates the robustness of the single‐loop controller. This work proposes a sensitivity representation that separates some of the natural FOWT dynamic coupling into a parallel feedback loop in the sensitivity function loop to address both of these concerns. The modified robustness measure is used with a simplified linear FOWT model to optimize scheduled multi‐loop control parameters in an automated tuning procedure. This controller is implemented for the 10‐MW Ultraflexible Smart FLoating Offshore Wind Turbine (USFLOWT) and compared against conventional single‐ and multi‐loop controllers tuned using frequency‐domain analysis and high‐fidelity OpenFAST simulations. The multi‐loop robust controller shows the highest overall performance in generator speed regulation and tower load reduction, though consideration of power quality, actuator usage, and other structural loading leads to additional trade‐offs.