Search NASA⌕ Search

SEARCH · Search NASA

Results for “low noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Simulation Based Inference with Domain Adaptation for Strong Gravitational Lensing

Simulation based inference leverages machine learning to carry out Bayesian inference for systems with intractable likelihoods. However, transitioning a network trained on simulated data to real data runs the risk of encountering domain shift, leading to performance losses. We attempt to implement domain adaptation into the sbi neural posterior estimation framework using the Maximum Mean Discrepancy as an additional network loss. We test two network architectures and use masked autoregressive flow for density estimation. We test the network on a set of 400,000 simulated strong gravitational lensing images generated using deeplenstronomy. The source domain is defined as low noise whereas the target domain has a noise profile sampled from experimentally derived DES survey conditions. We find that, while DA does lead to performance improvements, they are marginal at ~6% less inference error. We also find a similar marginal improvement in uncertainty calibration at around 8%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards Three-Dimensional Neutron Imaging with Light-field Technology

A broad range of applications in nuclear safeguards and security can benefit from compact, fast neutron imagers with large angular acceptance. However, accurate 3D multi-vertex reconstruction in a monolithic detector remains a significant barrier to realization. Current approaches, such as the centroiding approach and the use of shadow masks, have not yet resulted in a successful demonstration in a light-starved environment. This project explored the use of cutting-edge technology—a light field camera—which inherently preserves both the spatial and directional information of incident light. Such technology can, in principle, resolve multi-vertex events and offer accurate position reconstruction in 3D with relatively simple readout electronics. Since the project's inception in May 2023, we have built an experimental setup to calibrate and characterize a commercial light-field camera (Lytro Illum). We assessed its 3D event reconstruction capability in a relatively low-light intensity environment by analyzing the cross-correlation of a series of 2D images of a characterized tunable light source taken at various distances. A sub-cm resolution, lower than typical neutron interaction separations in a compact scintillator volume, was observed with the LED light source, suggesting the promising capability of its nominal optics design to provide the adequate resolution required for a compact monolithic neutron directional detector. However, using a light-field-based readout for a neutron camera requires incorporating an ultra-low-noise light sensor, which is beyond the scope of this project. We also initiated the development of a 3D light-field-based reconstruction algorithm tailored to sparse scenes, as expected from particle interactions in a scintillator medium. Additionally, we demonstrated the capability of the algorithm to replicate the ground truth. Finally, we began the development of a neutron directional detector simulation to determine the performance criteria for light-field-based reconstruction that allows for good neutron directional reconstruction. This Feasibility Study has led to a successful follow-up project under the DNN R&D innovation portfolio starting May 2024.

42 ENGINEERING↗

Refinement and Modeling of a Blackbody-Based Calibration Method in the InfraBREAD Detector

The Broadband Reflector Experiment for Axion Detection (BREAD) is an ongoing experiment searching for the conversion of yet undiscovered axion-like dark matter particles to photons in the presence of a magnetic field. InfraBREAD, a sub-experiment of BREAD, uses a superconducting nanowire single photon detector (SNSPD), a high-efficiency and low-noise device, to specifically detect infrared-range photons produced by $\mathcal{O}$(eV) axion-like particles. The unique BREAD reflector setup allows for the focusing of all converted signal photons to a 1mm $\times$ 1mm SNSPD. However, when the detector is cooled to cryogenic temperatures during operation, uneven thermal contraction of reflector components may lead to a small shift in the location of the focal spot. A novel calibration method using blackbody radiation is proposed to locate the true focal spot of the detector \textit{in situ}. Through ray tracing simulations done in FRED Optical Engineering Software, this method is demonstrated to locate the focus to within 50 $\mu$m in three dimensions.

Rao, Shardul↗

Comparison of the sensitivity of 236 U measurements in environmental samples by MC-ICP-MS and ATONA based high precision U TIMS measurements

The ATONA project is focused upon exploring the improvements in uranium isotope ratio measurements by thermal ionization mass spectrometry (TIMS) provided by a new, capacitor-based, amplifier technology. These “ATONA” Faraday amplifiers (Isotopx Ltd, UK) promise accurate, low-noise measurements of very small signals (< 1 femto-amp) in a traditional Faraday cup, which was only previously possible using an ion counter. This report outlines a series of experiments that were performed to assess the performance of the system in samples that test our rapid analysis procedures, and then compare the results against other mass spectrometry techniques currently available for environmental analyses. The following major goals were achieved: (1) illustrated the importance of 236 U measurements for the screening and analysis of environmental samples; (2) improved sensitivity for 236 U, and then identified 236 U in the 4350B standard at ultra-trace levels (3) Provided comparison of the 236 U sensitivity to multi-collector inductively coupled mass spectrometry techniques (4) Illustrated high TRL for the ATONA based measurement technique. This completes the reporting requirements for task 4 in the project LCP and highlights the utility of the system to make highly sensitive 236 U measurements in programmatically relevant sample matrices and at relevant uranium concentrations.

07 ISOTOPE AND RADIATION SOURCES↗

A 32-Channel Cryo-CMOS ASIC for SNSPD Biasing and Readout with Picosecond Timing

Superconducting nanowire single-photon detectors (SNSPD) are a promising technology for particle detection. Although SNSPDs have demonstrated picosecond timing accuracy, scaling up large arrays has proved challenging. In this work, we introduce a 32-channel cryo-CMOS application-specifc integrated circuit (ASIC) that can be tightly integrated with SNSPD arrays. The ASIC is designed to operate at a temperature of 4K and can perform up to 32 simultaneous timing measurements with a root-mean-square (RMS) accuracy of 8.0ps. The ASIC includes on-chip circuitry for externally biasing superconducting devices, low-noise amplifers for reading superconducting devices, high-resolution time-to-digital converters (TDC) for time-tagging events, and serializers for transmitting data to room-temperature electronics. The ASIC is manufactured in a 22nm FDSOI process and occupies an area of 4.0mm x 1.0mm. The performance of the ASIC was verifed using custom cryogenic device models internally developed for the 22nm SOI process. Measurement results will be presented at the conference.

Fredenburg, Jeff↗

Electron Ion Collider Strong Hadron Cooling design Summary

The Electron-Ion Collider (EIC) requires a high-energy cooler to maintain excellent beam quality and achieve high luminosity throughout long collision stores. To meet this requirement, the EIC project has adopted a novel approach known as Coherent Electron Cooling (CeC)—referred to as Strong Hadron Cooling (SHC)—which can provide rapid cooling rates at high energies. The SHC relies on an Energy Recovery Linac (ERL) to provide the intense, high-quality, and low-noise electron beam essential for the cooling process. This paper summarizes the design progress of the Strong Hadron Cooler for the EIC. We discuss key aspects of the project, including cooling physics modeling, luminosity evolution during collisions, the ERL design, risk mitigation strategies, remaining challenges, and ongoing R&D efforts.

43 PARTICLE ACCELERATORS↗

DUNE ND-LAr 2x2 Demonstrator Tests

A modular liquid argon (LAr) Time Projection Chamber (TPC) will be part of the near-detector facility for the Deep Underground Neutrino Experiment (DUNE). Such a TPC is being developed by the ArgonCube collaboration. To demonstrate the feasibility of the LAr DUNE Near Detector, a medium size prototype has been built: the ArgonCube 2x2 Demonstrator. The detector will be placed in the MINOS-ND hall, upstream of the current MINERνA/MINOS-ND locations, at Fermilab. Currently two modules are being tested at the Liquid Argon Test Facility (LArTF), before being place on-axis in the NuMI neutrino beam. The present report will be focused on the work done within the 2x2 Demonstrator group: the first part of the project is focused on the Low Noise AC Power distribution at LArTF, whereas the second is related to the 2x2 demonstrator light readout system tests.

43 PARTICLE ACCELERATORS↗

Machine Learning-Based Technique for Automated Sensor Characterization

The development of novel instrumentation requires an iterative cycle with three stages: design, prototyping, and testing. Recent advancements in simulation and nanofabrication techniques have significantly accelerated the design and prototyping phases. Nonetheless, detector characterization continues to be a major bottleneck in device development. During the testing phase, a significant time investment is required to characterize the device in different operating conditions and find optimal operating parameters. The total effort spent on characterization and parameter optimization can occupy a year or more of an expert s time. In this work, we present a novel technique for automated sensor calibration that aims to accelerate the testing stage of the development cycle. This technique leverages closed-loop Bayesian optimization (BO), using real-time measurements to guide parameter selection and identify optimal operating states. We demonstrate the method with a novel low-noise CCD, showing that the machine learning-driven tool can efficiently characterize and optimize operation of the sensor in a couple of days without supervision of a device expert.

Zepeda, Cuevas [Chicago U., KICP]↗

SRF-Based Quantum Transduction for Quantum Computing and Sensing

The next groundbreaking frontier in Quantum Information Science (QIS) is the development of low-noise interconnections over fiber optics between superconducting radio-frequency (SRF) quantum devices. High-efficiency microwave-optical transduction serves as a pivotal enabler for distributed quantum computing and sensor networks. This presentation will provide a comprehensive overview of quantum transduction achieved by coupling SRF cavities to electro-optic optical resonators, enabling efficient conversion between microwave and optical photons. This research, supported by the DOE Early Career Research Program, advances technologies for quantum computing and sensing, and complements the mission of the Superconducting Quantum Materials and Systems (SQMS) Center at Fermilab.

Zorzetti, Silvia [Fermilab] (ORCID:000000023208338↗

Automating Testing of DUNE Electronics via a Finite State Machine

The Deep Underground Neutrino Experiment (DUNE) is a flagship international collaboration designed to study neutrinos tiny, nearly massless particles that may hold answers to fundamental questions about the Universe. Fermilab s Robotic Test Stand (RTS) plays a critical role in ensuring the quality of approximately 50,000 Application-Specific Integrated Circuit (ASIC) chips that will be used in DUNE s massive liquid argon detectors. These electronics will be inside the cryostat; therefore, they will need to have a high yield of working chips and low noise. To improve the automation and reliability of the RTS, this project focused on designing and implementing a Python-based finite state machine (FSM) to manage chip handling workflows. The FSM was developed as a modular software framework to coordinate robotic arm movements, manage chip tray positions, and monitor system states during testing. Key features include robust error handling routines, a pause/resume system for safe mid-cycle interruptions, and a simulation mode for iterative testing without hardware dependencies. The system was designed to prepare for seamless integration with RTS hardware components such as the robotic arm and vision system. This integration will streamline collaboration and enable efficient deployment of updates across the six total institutions performing testing. The outcomes of this internship contribute to Fermilab s mission to advance high-energy physics and support the DOE s national goals by directly improving the testing of equipment to be used in DUNE. The project also provided valuable experience in software design and contributing to the success of DUNE.

Kang, Caleb [William Rainey Harper Coll.]↗

Superconducting Radio Frequency Resonators for Quantum Computing: A Short Review

Superconducting radiofrequency (SRF) technology is being used not only in discovery science programs and basic research but also for several applications that benefit society more directly. The advantage of superconducting resonators over those made of normal-conducting metal is their ability to store electromagnetic energy with much lower dissipation. The high-quality factor and longer dissipation time provided by these superconducting resonators can deliver superior performance. Currently, the quantum processing architecture uses resonators and interconnecting circuits operating in the microwave regime with superconducting strip-line technology and low noise electronic devices for switching and communication. The performance of these devices can be enhanced by embedding them in 3D SRF cavity resonators to prolong the coherence time, which improves the utility of the device by reducing error rates and allowing more manipulations (calculations) before the quantum state decays. Here, we present a short review of current microwave technology used in quantum computers and progress towards the 3D resonators to enhance thecoherence time.

Dhakal, Pashupati↗

Machine Learning-Enabled Wearable Piezoelectric Acoustic Sensor for Real-Time Breast Abnormality Detection

In contemporary society, breast health has become a significant public health concern, particularly among women. According to statistics from the World Health Organization, both the incidence and mortality rates of breast tumors have steadily increased in recent years. Therefore, effective early-stage screening and postoperative monitoring are essential for maintaining breast health. However, conventional clinical diagnostic modalities are typically bulky, operationally complex, and unsuitable for continuous real-time monitoring, which limits their use in portable and everyday health management applications. To address these limitations, this study proposes a machine learning-integrated wearable piezoelectric sensing platform as an auxiliary tool for breast health assessment. The device consists of a PDMS matching layer embedded with flexible silver nanowires, a P(VDF-TrFE) piezoelectric layer, and a multi-channel low-noise signal acquisition circuit. It is capable of acquiring acoustic echo signals from tissue-mimicking environments and automatically evaluating signal validity using a convolutional neural network (CNN). By integrating piezoelectric sensing with deep learning-based signal analysis, the proposed system achieves a signal-to-noise ratio exceeding 70 dB and a real-time classification accuracy above 96% under controlled conditions. These results demonstrate that the platform provides a compact, portable, and intelligent approach for wearable sensing of mechanical heterogeneity and highlight its potential for future development in continuous biomedical monitoring technologies.

He, Shuaitong↗

Case Study of High-Throughput Drug Screening and Remote Data Collection for SARS-CoV-2 Main Protease by Using Serial Femtosecond X-ray Crystallography

Since early 2020, COVID-19 has grown to affect the lives of billions globally. A worldwide investigation has been ongoing for characterizing the virus and also for finding an effective drug and developing vaccines. As time has been of the essence, a crucial part of this research has been drug repurposing; therefore, confirmation of in silico drug screening studies have been carried out for this purpose. Here we demonstrated the possibility of screening a variety of drugs efficiently by leveraging a high data collection rate of 120 images/second with the new low-noise, high dynamic range ePix10k2M Pixel Array Detector installed at the Macromolecular Femtosecond Crystallography (MFX) instrument at the Linac Coherent Light Source (LCLS). The X-ray Free-Electron Laser (XFEL) is used for remote high-throughput data collection for drug repurposing of the main protease (Mpro) of SARS-CoV-2 at ambient temperature with mitigated X-ray radiation damage. We obtained multiple structures soaked with nine drug candidate molecules in two crystal forms. Although our drug binding attempts failed, we successfully established a high-throughput Serial Femtosecond X-ray crystallographic (SFX) data collection protocol.

60 APPLIED LIFE SCIENCES↗

A Modular 512-Channel Neural Signal Acquisition ASIC for High-Density 4096 Channel Electrophysiology

The complexity of information processing in the brain requires the development of technologies that can provide spatial and temporal resolution by means of dense electrode arrays paired with high-channel-count signal acquisition electronics. In this work, we present an ultra-low noise modular 512-channel neural recording circuit that is scalable to up to 4096 simultaneously recording channels. The neural readout application-specific integrated circuit (ASIC) uses a dense 8.2 mm × 6.8 mm 2D layout to enable high-channel count, creating an ultra-light 350 mg flexible module. The module can be deployed on headstages for small animals like rodents and songbirds, and it can be integrated with a variety of electrode arrays. The chip was fabricated in a TSMC 0.18 µm 1.8 V CMOS technology and dissipates a total of 125 mW. Each DC-coupled channel features a gain and bandwidth programmable analog front-end along with 14 b analog-to-digital conversion at speeds up to 30 kS/s. Additionally, each front-end includes programmable electrode plating and electrode impedance measurement capability. We present both standalone and in vivo measurements results, demonstrating the readout of spikes and field potentials that are modulated by a sensory input.

47 OTHER INSTRUMENTATION↗

An Improved Measurement of the Secondary Cosmic Microwave Background Anisotropies from the SPT-SZ + SPTpol Surveys

We report new measurements of millimeter-wave power spectra in the angular multipole range 2000 ≤ ℓ ≤ 11,000 (angular scales ). By adding 95 and 150 GHz data from the low-noise 500 deg 2 SPTpol survey to the SPT-SZ three-frequency 2540 deg 2 survey, we substantially reduce the uncertainties in these bands. These power spectra include contributions from the primary cosmic microwave background, cosmic infrared background, radio galaxies, and thermal and kinematic Sunyaev–Zel'dovich (SZ) effects. The data favor a thermal SZ (tSZ) power at 143 GHz of and a kinematic SZ (kSZ) power of . This is the first measurement of kSZ power at ≥3 σ . However, different assumptions about the CIB or SZ models can reduce the significance down to 2.4 σ in the worst case. We study the implications of the measured kSZ power for the epoch of reionization under the Calabrese et al. model for the kSZ power spectrum and find the duration of reionization to be ( at 95% confidence), when combined with our previously published tSZ bispectrum measurement. The upper limit tightens to if the assumed homogeneous kSZ power is increased by 25% (~0.5 μ K 2 ) and relaxes to if the homogeneous kSZ power is decreased by the same amount.

79 ASTRONOMY AND ASTROPHYSICS↗

Scaler Rates from the Pierre Auger Observatory: A New Proxy of Solar Activity

The modulation of low-energy galactic cosmic rays reflects interplanetary magnetic field variations and can provide useful information on solar activity. An array of ground-surface detectors can reveal the secondary particles, which originate from the interaction of cosmic rays with the atmosphere. In this work, we present an investigation of the low-threshold rate (scaler) time series recorded in 16 yr of operation by the Pierre Auger Observatory surface detectors in Malargüe, Argentina. Through an advanced spectral analysis, we detected highly statistically significant variations in the time series with periods ranging from the decadal to the daily scale. We investigate their origin, revealing a direct connection with solar variability. Thanks to their intrinsic very low noise level, the Auger scalers allow a thorough and detailed investigation of the galactic cosmic-ray flux variations in the heliosphere at different timescales and can, therefore, be considered a new proxy of solar variability.

79 ASTRONOMY AND ASTROPHYSICS↗

CMB-S4: Foreground-cleaning Pipeline Comparison for Measuring Primordial Gravitational Waves

We compare multiple foreground-cleaning pipelines for estimating the tensor-to-scalar ratio, r, using simulated maps of the planned CMB-S4 experiment within the context of the South Pole Deep Patch. To evaluate robustness, we analyze bias and uncertainty on r across various foreground suites using map-based simulations. The foreground-cleaning methods include: a parametric maximum likelihood approach applied to auto- and cross-power spectra between frequency maps; a map-based parametric maximum-likelihood method; and a harmonic-space internal linear combination using frequency maps. We summarize the conceptual basis of each method to highlight their similarities and differences. To better probe the impact of foreground residuals, we implement an iterative internal delensing step, leveraging a map-based pipeline to generate a lensing B-mode template from the large aperture telescope frequency maps. Our results show that the performance of the three approaches is comparable for simple and intermediate-complexity foregrounds, with σ(r) ranging from 3–5 ×10 −4 . However, biases at the 1σ–2σ level appear when analyzing more complex forms of foreground emission. By extending the baseline pipelines to marginalize over foreground residuals, we demonstrate that contamination can be reduced to within statistical uncertainties, albeit with a pipeline-dependent impact on σ(r), which translates to a detection significance between 2σ and 4σ for an input value of r = 0.003. These findings suggest varying levels of maturity among the tested pipelines, with the auto- and cross-spectra-based approach demonstrating the best stability and overall performance. Moreover, given the extremely low noise levels, mutual validation of independent foreground-cleaning pipelines is essential to ensure the robustness of any potential detection.

astronomy data analysis↗

First Axionlike Particle Results from a Broadband Search for Wavelike Dark Matter in the 44 to 52 μ eV Range with a Coaxial Dish Antenna

We present the results from the first axionlike particle search conducted using a dish antenna. The experiment was conducted at room temperature and sensitive to axionlike particles in the 44 – 52 μ eV range (10.7–12.5 GHz). The novel dish antenna geometry was proposed by the BREAD Collaboration and previously used to conduct a dark photon search in the same mass range. To allow for axionlike particle sensitivity, the BREAD dish antenna was placed in a 3.9 T solenoid magnet at Argonne National Laboratory. In the presence of a magnetic field, axionlike dark matter converts to photons at the conductive surface of the reflector. The signal is focused onto a custom coaxial horn antenna and read out with a low-noise radio-frequency receiver. No evidence of axionlike dark matter was observed in this mass range and we place the most stringent laboratory constraints on the axion-photon coupling strength, g a γ γ , in this mass range at 90% confidence.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗