Search NASA⌕ Search

SEARCH · Search NASA

Results for “low noise temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

High-Temperature Smart Structures for Engine Noise Reduction and Performance Enhancement

One of key NASA goals is to develop and integrate noise reduction technology to enable unrestricted air transportation service to all communities. One of the technical priorities of this activity has been to account for and reduce noise via propulsion/airframe interactions, identifying advanced concepts to be integrated with the airframe to mitigate these noise-producing mechanisms. An adaptive geometry chevron using embedded smart structures technology offers the possibility of maximizing engine performance while retaining and possibly enhancing the favorable noise characteristics of current designs. New high-temperature shape memory alloy (HTSMA) materials technology enables the devices to operate in both low-temperature (fan) and high-temperature (core) exhaust flows. Chevron-equipped engines have demonstrated reduced noise in testing and operational use. It is desirable to have the noise benefits of chevrons in takeoff/landing conditions, but have them deployed into a minimum drag position for cruise flight. The central feature of the innovation was building on rapidly maturing HTSMA technology to implement a next-generation aircraft noise mitigation system centered on adaptive chevron flow control surfaces. In general, SMA-actuated devices have the potential to enhance the demonstrated noise reduction effectiveness of chevron systems while eliminating the associated performance penalty. The use of structurally integrated smart devices will minimize the mechanical and subsystem complexity of this implementation. The central innovations of the effort entail the modification of prior chevron designs to include a small cut that relaxes structural stiffness without compromising the desired flow characteristics over the surface; the reorientation of SMA actuation devices to apply forces to deflect the chevron tip, exploiting this relaxed stiffness; and the use of high-temperature SMA (HTSMA) materials to enable operation in the demanding core chevron environment. The overall conclusion of these design studies was that the cut chevron concept is a critical enabling step in bringing the variable geometry core chevron within reach. The presence of the cut may be aerodynamically undesirable in some respects, but it is present only when the chevron is not immersed in the core jet exhaust. When deployed, the gap closes as the chevron tip enters the high-speed, high-temperature core stream. Aeroacoustic testing and flow visualization support the contention that this cut is inconsequential to chevron performance.

Quackenbush, Todd R.↗

Engine component improvement: Performance improvement, JT9D-7 3.8 AR fan

A redesigned, fuel efficient fan for the JT9D-7 engine was tested. Tests were conducted to determine the effect of the 3.8 AR fan on performance, stability, operational characteristics, and noise of the JT9D-7 engine relative to the current 4.6 AR Bill-of-Material fan. The 3.8 AR fan provides increased fan efficiency due to a more advanced blade airfoil with increased chord, eliminating one part span shroud and reducing the number of fan blades and fan exit guide vanes. Engine testing at simulated cruise conditions demonstrated the predicted 1.3 percent improvement in specific fuel consumption with the redesigned 3.8 AR fan. Flight testing and sea level stand engine testing demonstrated exhaust gas temperature margins, fan and low pressure compressor stability, operational suitability, and noise levels comparable to the Bill-of-Material fan.

Gaffin, W. O.↗

Block 2A traveling-wave maser

Two 8.4GHz low-noise traveling-wave masers (TWMS) with effective input noise temperatures of 3.6 to 3.9 K and bandwidth in excess of 100 MHz have been supplied to the Deep Space Network. These TWMs are used on the 64-meter antennas at Deep Space Stations 14 and 43 to meet the requirements of the Voyager Uranus encounter. The TWMs have improved isolator assemblies and new interstage matching configurations to reduce gain/bandwidth ripple. They are equipped with followup Field Effect Transistor Amplifiers as part of the design to meet the 100-MHz bandwidth requirements of very long baseline interferometry.

Trowbridge, D. L.↗

Efficient He-4 cryostats for storage Dewars

He-4 cryostats which can be inserted into storage Dewars were designed. These cryostats have the advantages of extremely low (and recoverable) helium consumption, fast cool-down and warm-up times, excellent temperature range and stability, and they supply a low electrical noise and low vibration environment for electrical and thermal measurements. Design and construction details of one such cryostat are presented. Specific heat data on crystalline boron are also presented to demonstrate the performance of one of these cryostats in a particularly sensitive experiment.

Swartz, E. T.↗

All-solid-state radiometers for environmental studies to 700 GHz

We report results with an all-solid-state radiometer for measurements of the ClO molecule at 649 GHz. The project is part of a program to provide low-noise, low-weight, low-power radiometers for space operation, and special effort has been expended on the development of high-efficiency solid-state frequency multipliers and Schottky-barrier mixers with low local oscillator power requirements. The best measured system noise temperature was 1750 K with the mixer and preamplifier cooled to 77 K. The mixer diode was easily pumped into saturation, indicating that the design has excellent prospects of operating at higher frequencies - our present design goal being 1 THz. We comment on the principal design features of such systems and will report on stratospheric measurements performed with this system.

Zimmermann, Ralph↗

Feasibility of Passive Cryogenic Cooling for Solar Powered Outer Planetary Missions

Spacescience instruments with cooled detectors require innovative thermal cooling solutions to meet science objectives. Detector sensitivity increases with decreasing temperature and low optics temperatures are often needed to reduce background photon noise. As the detector spectral range coverage increases from the visible to far infrared also requires lower detector temperatures. Increasing demands on detector performance lead to larger format detectors and higher refresh rates resulting in significant increases in power dissipation. Passive coolers rely on emissive power of radiating surfaces to reject heat to space. As the operating temperature requirements of detectors and optics decreases, the ability to reject heat to space becomes increasingly more difficult. Reducing both cooler internal parasitic and external environmental heat loads and maximizing the passive cooler field of view to space will enhance performance. While instrument heat loads and passive cooler parasitic heat loads are controlled by instrument designers, the external environmental heat loads and cooler views to space are governed by spacecraft and mission designers. Solar powered planetary missions require large arrays to generate sufficient power for spacecraft subsystems and payloads. Two or more solar array wings with cell coverage of the order of 40-80 m2 are often needed to generate sufficient power at 3-6 AU. These large arrays are typically symmetrically configured and can extend tens of meters. The arrays along with spacecraft attitude requirements near the target planetary bodies pose significant challenges for passive cooling at large AU. It is very difficult to provide a clear field of view to space for the cooler with large articulating arrays while keeping solar loads from impinging the cooler and meeting the spacecraft attitude science pointing requirements. This is counter intuitive because of the decreasing solar flux and colder planetary body temperatures at large AU. This paper presents the challenges and opportunities of passive cryogenic cooling versus active cooling for solar powered planetary missions.

Rodriguez, Jose I.↗

Effect of a semi-annular thermal acoustic shield on jet exhaust noise

Reductions in jet exhaust noise obtained by the use of an annular thermal acoustic shield consisting of a high temperature, low velocity gas stream surrounding a high velocity central jet exhaust appear to be limited by multiple reflections. The effect of a semi-annular shield on jet exhaust noise was investigted with the rationale that such a configuration would eliminate or reduce the multiple reflection mechanism. Noise measurements for a 10 cm conical nozzle with a semi-annular acoustic shield are presented in terms of lossless free field data at various angular locations with respect to the nozzle. Measurements were made on both the shielded and unshielded sides of the nozzle. The results are presented parametrically, showing the effects of various shield and central system velocities and temperatures. Selected results are scaled up to a typical full scale engine size to determine the perceived noise level reductions.

Goodykoontz, J.↗

Nernst–Ettingshausen effect in thin Pt and W films at low temperatures

As spin caloritronic measurements become increasingly common techniques for characterizing material properties, it is important to quantify potentially confounding effects. We report measurements of the Nernst–Ettingshausen response from room temperature to 5 K in thin film wires of Pt and W, metals commonly used as inverse spin Hall detectors in spin Seebeck characterization. Johnson–Nyquist noise thermometry is used to assess the temperature change in the metals with heater power at low temperatures, and the thermal path is analyzed via finite-element modeling. The Nernst–Ettingshausen response of W is found to be approximately temperature-independent, while the response of Pt increases at low temperatures. Furthermore, these results are discussed in the context of theoretical expectations and the possible role of magnetic impurities in Pt.

36 MATERIALS SCIENCE↗

LWIR detector behavior at very low frequencies

Measurements have been made of the signal and noise characteristics of extrinsic photoconductive silicon detectors. The measurements were made at several background levels, bias voltages and detector operating temperatures. Data are shown at modulation frequencies as low as 0.01 Hz, operating temperatures as low as 2.5K and background photon flux densities down to 8 x 10 to the 7th photons/sec-sq cm. Data on the temporal characteristics of the detector signal are presented. In addition, some interesting data on 'spontaneous noise spikes' are also shown.

Arrington, D. C.↗

Ambient and cryogenic temperature testing of a 32-channel CMOS multiplexer

A 32 channel CMOS multiplexer was tested at room temperature and at liquid helium temperature (4.9 K). Voltage gain of the FET input stage, leakage current, electrical crosstalk, and noise as a function of clock frequency were measured. The voltage gain measured at 4.9 K was slightly higher than that measured at 300 K and was independent of clock frequency at both operating temperatures. The off channel leakage current was 0.23 pA/channel at 4.9 K. Electrical crosstalk between adjacent channels (one on, one off) was quite low. The spot noise at 10 Hz, of the CMOS multiplexer operating in the static mode did not vary significantly with operating temperature. In the dynamic mode (3.2 kHz clock) at room temperature, the spot noise at 10 Hz was substantially higher than that measured in the static mode.

Lee, J. H.↗

Time-Average Measurement of Velocity, Density, Temperature, and Turbulence Using Molecular Rayleigh Scattering

Measurement of time-averaged velocity, density, temperature, and turbulence in gas flows using a nonintrusive, point-wise measurement technique based on molecular Rayleigh scattering is discussed. Subsonic and supersonic flows in a 25.4-mm diameter free jet facility were studied. The developed instrumentation utilizes a Fabry-Perot interferometer to spectrally resolve molecularly scattered light from a laser beam passed through a gas flow. The spectrum of the scattered light contains information about velocity, density, and temperature of the gas. The technique uses a slow scan, low noise 16-bit depth CCD camera to record images of the fringes formed by Rayleigh scattered light passing through the interferometer. A kinetic theory model of the Rayleigh scattered light is used in a nonlinear least squares fitting routine to estimate the unknown parameters from the fringe images. The ability to extract turbulence information from the fringe image data proved to be a challenge since the fringe is broadened by not only turbulence, but also thermal fluctuations and aperture effects from collecting light over a range of scattering angles. Figure 1 illustrates broadening of a Rayleigh spectrum typical of flow conditions observed in this work due to aperture effects and turbulence for a scattering angle, chi(sub s), of 90 degrees, f/3.67 collection optics, mean flow velocity, u(sub k), of 300 m/s, and turbulent velocity fluctuations, sigma (sub uk), of 55 m/s. The greatest difficulty in processing the image data was decoupling the thermal and turbulence broadening in the spectrum. To aid in this endeavor, it was necessary to seed the ambient air with smoke and dust particulates; taking advantage of the turbulence broadening in the Mie scattering component of the spectrum of the collected light (not shown in the figure). The primary jet flow was not seeded due to the difficulty of the task. For measurement points lacking particles, velocity, density, and temperature information could reliably be recovered, however the turbulence estimates contained significant uncertainty. Resulting flow parameter estimates are presented for surveys of Mach 0.6, 0.95, and 1.4 jet flows. Velocity, density, and temperature were determined with accuracies of 5 m/s, 1.5%, and 1%, respectively, in flows with no particles present, and with accuracies of 5 m/s, 1-4%, and 2% in flows with particles. Comparison with hotwire data for the Mach 0.6 condition demonstrated turbulence estimates with accuracies of about 5 m/s outside the jet core where Mie scattering from dust/smoke particulates aided in the estimation of turbulence. Turbulence estimates could not be recovered with any significant accuracy for measurement points where no particles were present.

Mielke, Amy F.↗

Ultralow-temperature cryogenic transmission electron microscopy using a new helium flow cryostat stage

Advances in cryogenic electron microscopy have opened new avenues for probing quantum phenomena in correlated materials. This study reports the installation and performance of a new side-entry condenZero cryogenic cooling system for JEOL (Scanning) Transmission Electron Microscopes (S/TEM), utilizing compressed liquid helium (LHe) and designed for imaging and spectroscopy at ultra-low temperatures. The system includes an external dewar mounted on a vibration-damping stage and a pressurized, low-noise helium transfer line with a remotely controllable needle valve, ensuring stable and efficient LHe flow with minimal thermal and mechanical noise. Performance evaluation demonstrates a stable base temperature of 4.37 K measured using a Cernox bare chip sensor on the holder with temperature fluctuations within ±0.004 K. Complementary in-situ electron energy-loss spectroscopy (EELS) via aluminum bulk plasmon analysis was used to measure the local specimen temperature and validate cryogenic operation during experiments. The integration of cryogenic cooling with other microscopy techniques, including electron diffraction and Lorentz TEM, was demonstrated by resolving charge density wave (CDW) transitions in NbSe2 using electron diffraction, and imaging nanometric magnetic skyrmions in MnSi via Lorentz TEM. In conclusion, this platform provides reliable cryogenic operation below 7 K, establishing a low-drift route for direct visualization of electronic and magnetic phase transformations in quantum materials.

Charge density wave↗

High resolution, low energy avalanche photodiode X-ray detectors

Silicon avalanche photodiodes have been fabricated, and their performance as X-ray detectors has been measured. Photon sensitivity and energy resolution were measured as a function of size and operating parameters. Noise thresholds as low as 212 eV were obtained at room temperature, and backscatter X-ray fluorescence data were obtained for aluminum and other light elements. It is concluded that the results with the X-ray detector are extremely encouraging, and the performance is challenging the best available proportional counters. While not at the performance level of either cryogenic silicon or HgI2, these device operate at room temperature and can be reproduced in large numbers and with much larger areas than typically achieved with HgI2. In addition, they are rugged and appear to be indefinitely stable.

Farrell, R.↗

Cryogenic Pound Circuits for Cryogenic Sapphire Oscillators

Two modern cryogenic variants of the Pound circuit have been devised to increase the frequency stability of microwave oscillators that include cryogenic sapphire-filled cavity resonators. The original Pound circuit is a microwave frequency discriminator that provides feedback to stabilize a voltage-controlled microwave oscillator with respect to an associated cavity resonator. In the present cryogenic Pound circuits, the active microwave devices are implemented by use of state-of-the-art commercially available tunnel diodes that exhibit low flicker noise (required for high frequency stability) and function well at low temperatures and at frequencies up to several tens of gigahertz. While tunnel diodes are inherently operable as amplitude detectors and amplitude modulators, they cannot, by themselves, induce significant phase modulation. Therefore, each of the present cryogenic Pound circuits includes passive circuitry that transforms the AM into the required PM. Each circuit also contains an AM detector that is used to sample the microwave signal at the input terminal of the high-Q resonator for the purpose of verifying the desired AM null at this point. Finally, each circuit contains a Pound signal detector that puts out a signal, at the modulation frequency, having an amplitude proportional to the frequency error in the input signal. High frequency stability is obtained by processing this output signal into feedback to a voltage-controlled oscillator to continuously correct the frequency error in the input signal.

Dick, G. John↗

VUV Testing of Science Cameras at MSFC: QE Measurement of the CLASP Flight Cameras

The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras were built and tested for the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The CLASP camera design includes a frame-transfer e2v CCD57-10 512x512 detector, dual channel analog readout electronics and an internally mounted cold block. At the flight operating temperature of -20 C, the CLASP cameras achieved the low-noise performance requirements (less than or equal to 25 e- read noise and greater than or equal to 10 e-/sec/pix dark current), in addition to maintaining a stable gain of approximately equal to 2.0 e-/DN. The e2v CCD57-10 detectors were coated with Lumogen-E to improve quantum efficiency (QE) at the Lyman- wavelength. A vacuum ultra-violet (VUV) monochromator and a NIST calibrated photodiode were employed to measure the QE of each camera. Four flight-like cameras were tested in a high-vacuum chamber, which was configured to operate several tests intended to verify the QE, gain, read noise, dark current and residual non-linearity of the CCD. We present and discuss the QE measurements performed on the CLASP cameras. We also discuss the high-vacuum system outfitted for testing of UV and EUV science cameras at MSFC.

Champey, Patrick↗

VUV Testing of Science Cameras at MSFC: QE Measurement of the CLASP Flight Cameras

The NASA Marshall Space Flight Center (MSFC) has developed a science camera suitable for sub-orbital missions for observations in the UV, EUV and soft X-ray. Six cameras were built and tested for the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), a joint National Astronomical Observatory of Japan (NAOJ) and MSFC sounding rocket mission. The CLASP camera design includes a frame-transfer e2v CCD57-10 512x512 detector, dual channel analog readout electronics and an internally mounted cold block. At the flight operating temperature of -20 C, the CLASP cameras achieved the low-noise performance requirements (less than or equal to 25 e- read noise and greater than or equal to 10 e-/sec/pix dark current), in addition to maintaining a stable gain of approximately equal to 2.0 e-/DN. The e2v CCD57-10 detectors were coated with Lumogen-E to improve quantum efficiency (QE) at the Lyman- wavelength. A vacuum ultra-violet (VUV) monochromator and a NIST calibrated photodiode were employed to measure the QE of each camera. Four flight-like cameras were tested in a high-vacuum chamber, which was configured to operate several tests intended to verify the QE, gain, read noise, dark current and residual non-linearity of the CCD. We present and discuss the QE measurements performed on the CLASP cameras. We also discuss the high-vacuum system outfitted for testing of UV and EUV science cameras at MSFC.

Camera↗

Performance of High-Resolution Mo/Cu Transition Edge Sensors Fabricated Using a Lift-Off Process

The soft X-ray band below ≈0.5 keV is expected to provide rich information on metallicity, temperature, and distribution of hot gas in our galaxy and the intergalactic medium. Resolving these densely spaced emission lines requires energy resolution on the order of 1--2 eV. The low count rates from diffuse astrophysical sources also necessitate large collection areas, particularly for a sounding rocket instrument with short exposure times and limited resources. This translates to large pixel sizes (about 1 mm 2 ) for a reasonable number of read-out channels. To achieve the required energy resolution with 200 nm thin Au absorbers (heat capacity C about 1 pJ/K), we are developing TES microcalorimeters with very high temperature sensitivity (αI), low enough current sensitivity (βI), and minimal excess noise (M). Out of the various fabrication approaches for the TES bilayer we have explored, the lift-off approach (as pioneered for Mo/Au TES by Joel Weber at NIST) so far is the simplest to execute. The simple square TES geometries we have tested to date show promising results for αI and βI. Measured complex impedance and noise for bare devices without absorbers are well described by two-body thermal models and their excess noise is found to be consistent with predictions for mixed-down Johnson noise by Wessels et al. More sensitive measurements with larger heat capacity are planned to accurately determine excess noise. In this paper, we give an overview of the process and summarize results of our detailed characterization measurements for thermal conductance G, αI, βI, and noise for several devices across a range of bias points.

Felix T Jaeckel↗