Search NASA⌕ Search

SEARCH · Search NASA

Results for “magneto-optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Electromagnetic Detection of Fatigue Cracks under Protruding Head Ferromagnetic Fasteners

The detection of fatigue cracks under installed fasteners has been a major goal of the aging aircraft NDE community. The Sliding Probe, Magneto-Optic Imager, Rotating Self-Nulling Probe, Low Frequency Eddy Current Array, and Eddyscan systems are among the instruments developed for this inspection. It has been verified that the detection of fatigue cracks under flush head aluminum and titanium fasteners can be accomplished with a high resolution by the above techniques. The detection of fatigue cracks under ferromagnetic and protruding head fasteners, however, has been found to be much more difficult. For the present work, the inspection for fatigue cracks under SAE 4340 Steel Hi-Lok fasteners is explored. Modifications to the Rotating Self-Nulling Eddy Current Probe System are presented which enable the detection of fatigue cracks hidden under the protruding head of the ferromagnetic fastener. Inspection results for samples with varying length EDM notches are shown, as well as a comparison between the signature from an EDM notch and an actual fatigue crack. Finite Element Modeling is used to investigate the effect of the ferromagnetic fastener on the induced eddy current distribution in order to help explain the detection characteristics of the system. This paper will also introduce a modification to the Rotating Probe System designed specifically for the detection of deeply buried flaws in multilayer conductors. The design change incorporates a giant magnetoresistive (GMR) sensor as the pickup device to improve the low frequency performance of the probe. The flaw detection capabilities of the GMR based Self- Nulling Probe are presented along with the status of the GMR based Rotating Probe System for detection of deeply buried flaws under installed fasteners.

Wincheski, Buzz↗

Doppler Observations of the Impact of Comet SL9 Fragment A

An attempt to detect Doppler effects on Jupiter during the impact of fragment A of the Shoemaker-Levy 9 comet is discussed. A short description is given of the technique used to observe the impact. Observations are presented, and a theoretical analysis and inter- pretation are given. The instrumentation used is an advanced and more sensitive version of the Magneto-Optical Filter & a 40 cm telescope.

Shoemaker-Levy 9 Jupiter comet fragment A doppler ↗

Chromospheric observations in the helium 1083NM line : a new instrument

Photometric, spectroscopic and polarimetric observations in the Helium 1083 nm line provide important diagnostic information on the structure and dynamics of the chromosphere. We describe an imaging instrument designed to probe the chromosphere in the Helium 1083nm line, based on a Helium magneto-optical filter. The instrument has two narrow passbands ((almost equal to) 0.006 nm) in the wings of each line of the Helium 1083nm triplet, high throughput and stability, making it ideal for making high cadence observations in support of studies of chromospheric dynamics and wave propagation. We describe the characteristics of the instrument and present preliminary observations and discuss future plans.

solar atmosphere↗

Dual-Beam Atom Laser Driven by Spinor Dynamics

An atom laser now undergoing development simultaneously generates two pulsed beams of correlated Rb-87 atoms. (An atom laser is a source of atoms in beams characterized by coherent matter waves, analogous to a conventional laser, which is a source of coherent light waves.) The pumping mechanism of this atom laser is based on spinor dynamics in a Bose-Einstein condensate. By virtue of the angular-momentum conserving collisions that generate the two beams, the number of atoms in one beam is correlated with the number of atoms in the other beam. Such correlations are intimately linked to entanglement and squeezing in atomic ensembles, and atom lasers like this one could be used in exploring related aspects of Bose-Einstein condensates, and as components of future sensors relying on atom interferometry. In this atom-laser apparatus, a Bose-Einstein condensate of about 2 x 10(exp 6) Rb-87 atoms at a temperature of about 120 micro-K is first formed through all-optical means in a relatively weak singlebeam running-wave dipole trap that has been formed by focusing of a CO2-laser beam. By a technique that is established in the art, the trap is loaded from an ultrahigh-vacuum magnetooptical trap that is, itself, loaded via a cold atomic beam from an upstream two-dimensional magneto-optical trap that resides in a rubidium-vapor cell that is differentially pumped from an adjoining vacuum chamber, wherein are performed scientific observations of the beams ultimately generated by the atom laser.

Thompson, Robert↗

A Transportable Gravity Gradiometer Based on Atom Interferometry

A transportable atom interferometer-based gravity gradiometer has been developed at JPL to carry out measurements of Earth's gravity field at ever finer spatial resolutions, and to facilitate high-resolution monitoring of temporal variations in the gravity field from ground- and flight-based platforms. Existing satellite-based gravity missions such as CHAMP and GRACE measure the gravity field via precise monitoring of the motion of the satellites; i.e. the satellites themselves function as test masses. JPL's quantum gravity gradiometer employs a quantum phase measurement technique, similar to that employed in atomic clocks, made possible by recent advances in laser cooling and manipulation of atoms. This measurement technique is based on atomwave interferometry, and individual laser-cooled atoms are used as drag-free test masses. The quantum gravity gradiometer employs two identical atom interferometers as precision accelerometers to measure the difference in gravitational acceleration between two points (Figure 1). By using the same lasers for the manipulation of atoms in both interferometers, the accelerometers have a common reference frame and non-inertial accelerations are effectively rejected as common mode noise in the differential measurement of the gravity gradient. As a result, the dual atom interferometer-based gravity gradiometer allows gravity measurements on a moving platform, while achieving the same long-term stability of the best atomic clocks. In the laboratory-based prototype (Figure 2), the cesium atoms used in each atom interferometer are initially collected and cooled in two separate magneto-optic traps (MOTs). Each MOT, consisting of three orthogonal pairs of counter-propagating laser beams centered on a quadrupole magnetic field, collects up to 10(exp 9) atoms. These atoms are then launched vertically as in an atom fountain by switching off the magnetic field and introducing a slight frequency shift between pairs of lasers to create a moving rest frame for the trapped atoms. While still in this moving-frame molasses, the laser frequencies are further detuned from the atomic resonance (while maintaining this relative frequency shift) to cool the atom cloud's temperature to 2 K or below, corresponding to an rms velocity of less than 2 cm/s. After launch, the cold atoms undergo further state and velocity selection to prepare for atom interferometry. The atom interferometers are then realized using laser-induced stimulated Raman transitions to perform the necessary manipulations of each atom, and the resulting interferometer phase is measured using laser-induced fluorescence for state-normalized detection. More than 20 laser beams with independent controls of frequency, phase, and intensity are required for this measurement sequence. This instrument can facilitate the study of Earth's gravitational field from surface and air vehicles, as well as from space by allowing gravity mapping from a low-cost, single spacecraft mission. In addition, the operation of atom interferometer-based instruments in space offers greater sensitivity than is possible in terrestrial instruments due to the much longer interrogation times available in the microgravity environment. A space-based quantum gravity gradiometer has the potential to achieve sensitivities similar to the GRACE mission at long spatial wavelengths, and will also have resolution similar to GOCE for measurement at shorter length scales.

Yu, Nan↗

Method for Implementing Optical Phase Adjustment

A method has been developed to mechanically implement the optical phase shift by adjusting the polarization of the pump and probe beams in an NMOR (nonlinear magneto-optical rotation) magnetometer as the proper phase shift is necessary to induce self-oscillation. This innovation consists of mounting the pump beam on a ring that surrounds the atomic vapor sample. The propagation of the probe beam is perpendicular to that of the pump beam. The probe beam can be considered as defining the axis of a cylinder, while the pump beam is directed radially. The magnetic field to be measured defines a third vector, but it is also taken to lie along the cylinder axis. Both the pump and probe beams are polarized such that their electric field vectors are substantially perpendicular to the magnet field. By rotation of the ring supporting the pump beam, its direction can be varied relative to the plane defined by the probe electric field and the magnetic field to be measured.

Hovde, David C.↗

Hidden Identification on Parts: Magnetic Machine-Readable Matrix Symbols

All NASA parts have identification, usually expressed in terms of part number, serial number, and the like. In most cases, this identification is permanently marked directly on the part for tracking throughout its life cycle. NASA has developed a method for reading the matrix symbol through up to 15 mils (25 m) of paint (5 or 6 layers). This method of part identification involves coating selected patches on the objects with magnetic materials in matrix symbol patterns and reading the patterns by use of magneto-optical imaging equipment.

Schramm, Harry F.↗

Direct Simulation of Multiple Scattering by Discrete Random Media Illuminated by Gaussian Beams

The conventional orientation-averaging procedure developed in the framework of the superposition T-matrix approach is generalized to include the case of illumination by a Gaussian beam (GB). The resulting computer code is parallelized and used to perform extensive numerically exact calculations of electromagnetic scattering by volumes of discrete random medium consisting of monodisperse spherical particles. The size parameters of the scattering volumes are 40, 50, and 60, while their packing density is fixed at 5%. We demonstrate that all scattering patterns observed in the far-field zone of a random multisphere target and their evolution with decreasing width of the incident GB can be interpreted in terms of idealized theoretical concepts such as forward-scattering interference, coherent backscattering (CB), and diffuse multiple scattering. It is shown that the increasing violation of electromagnetic reciprocity with decreasing GB width suppresses and eventually eradicates all observable manifestations of CB. This result supplements the previous demonstration of the effects of broken reciprocity in the case of magneto-optically active particles subjected to an external magnetic field.

Mackowski, Daniel W.↗

Development of the Science Data System for the International Space Station Cold Atom Lab

Cold Atom Laboratory (CAL) is a facility that will enable scientists to study ultra-cold quantum gases in a microgravity environment on the International Space Station (ISS) beginning in 2016. The primary science data for each experiment consists of two images taken in quick succession. The first image is of the trapped cold atoms and the second image is of the background. The two images are subtracted to obtain optical density. These raw Level 0 atom and background images are processed into the Level 1 optical density data product, and then into the Level 2 data products: atom number, Magneto-Optical Trap (MOT) lifetime, magnetic chip-trap atom lifetime, and condensate fraction. These products can also be used as diagnostics of the instrument health. With experiments being conducted for 8 hours every day, the amount of data being generated poses many technical challenges, such as downlinking and managing the required data volume. A parallel processing design is described, implemented, and benchmarked. In addition to optimizing the data pipeline, accuracy and speed in producing the Level 1 and 2 data products is key. Algorithms for feature recognition are explored, facilitating image cropping and accurate atom number calculations.

bose einstein condensate↗

Center-to-Limb Variation of the Polarization of Mg II H & K Lines as Measured by CLASP2

Who cares? Magnetograms in the upper chromosphere are needed for accurate magnetic coronal extrapolations. The CLASP2 sounding rocket took spatially resolved spectropolarimetric data of Mg II h & k in the upper chromosphere, that can be used as a pathfinder to routine magnetograms. This work: Preliminary results of the center-to-limb variation (CLV) of the linear polarization in the quiet sun. We compare the signals to recent theoretical calculations of the expected polarization which include PRD, J-state interference, and magneto-optical effects.

Rachmeler, Laurel↗

Compact Doppler Magnetograph

Here we present a design for a high-performance, compact, low-cost flight instrument that measures velocity and magnetic fields on the photospere. This instrument is called the Compact Doppler Magnetograph, or CDM, and is based on the magneto-optical filter invented by A. Cacciani.

Doppler↗

Effect of metal encapsulation on bulk superconducting properties of niobium thin films used in qubits

Niobium metal occupies nearly 100% of the volume of a typical 2D transmon device. While the aluminum Josephson junction is of utmost importance, maintaining quantum coherence across the entire device means that pair-breaking in Nb leads, capacitive pads, and readout resonators can be a major source of decoherence. The established contributors are surface oxides and hydroxides, as well as absorbed hydrogen and oxygen. Metal encapsulation of freshly grown surfaces with non-oxidizing metals, preferably without breaking the vacuum, is a successful strategy to mitigate these issues. While the positive effects of encapsulation are undeniable, it is important to understand its impact on the macroscopic behavior of niobium films. We present a comprehensive study of the bulk superconducting properties of Nb thin films encapsulated with gold and palladium/gold, and compare them to those of bare Nb films. Magneto-optical imaging, magnetization, resistivity, and London and Campbell penetration depth measurements reveal significant differences in encapsulated samples. Both sputtered, and epitaxial Au-capped films exhibit the highest residual resistivity ratio and superconducting transition temperature, as well as the lowest upper critical field, London penetration depth, and critical current. These results are in good agreement with the microscopic theory of anisotropic normal and superconducting states of Nb. We conclude that pair-breaking in the bulk of niobium films, driven by disorder throughout the film rather than just at the surface, is a significant source of quantum decoherence in transmons. We also conclude that gold capping not only passivates the surface but also affects the properties of the entire film, significantly reducing the scattering rate due to defects likely induced by surface diffusion if the film is not protected immediately after fabrication.

Datta, Amlan [Ames Lab; Iowa State U.]↗

Magnetic flux distribution, quasiparticle spectroscopy, and quality factors in Nb films for superconducting qubits

Niobium is a practical material platform for superconducting microwave circuits; however, device-level performance can vary significantly depending on film growth and processing conditions. We compare three epitaxial Nb films grown on $c-$plane sapphire substrates under nominally identical conditions, except for the deposition temperature. To correlate internal quality factors, $Q_{\mathrm {i}}$, with material properties, we combine magneto-optical imaging of magnetic flux distribution with quasiparticle spectroscopy via measurements of the London penetration depth, $λ(T)$. In the low-$Q_{\mathrm i}$ film, there is a lesser ability to screen the magnetic field and an irregular temperature variation of $λ(T)$, implying the existence of localized in-gap states. High $Q_{\mathrm i}$ films show the opposite trend. We conclude that our measurements provide an efficient method for characterizing and optimizing superconducting films for quantum informatics applications.

Datta, Amlan [Ames Lab; Iowa State U.]↗

Magnetically Tunable Polariton Cavities in van der Waals Heterostructures

Nanophotonic cavities are the foundation for a broad spectrum of applications, including quantum sensing, on-chip communication, and cavity quantum electrodynamics. In van der Waals (vdW) materials, these cavities can harness polaritons, which are quasiparticles emerging from photon interactions with excitons, plasmons, or phonons that are confined in microscopic sample flakes. Hybrid phonon–plasmon cavities leverage the long lifetimes of phonons and good tunability of plasmons, but their reconfigurability remains fundamentally limited. Here, in this work, we introduce a magnetic-field-tuning mechanism for polaritonic cavities in a vdW heterostructure. Specifically, we demonstrate that the primary Landau transition in magnetized charge-neutral graphene can be harvested for controlling polaritonic cavity modes in a graphene-based phononic heterostructure. Additionally, we predict a magnetic-field-induced topological transition in the polariton isofrequency contour, causing a nontrivial cavity mode profile redistribution. Our study underscores the versatility of Landau-based nanophotonic cavities, offering new paradigms for the design and manipulation of light–matter interactions at the nanoscale.

36 MATERIALS SCIENCE↗

Spin switchable optical phenomena in Rashba band structures through intersystem crossing in momentum space in solution-processing 2D-superlattice perovskite film

Spin-switchable phenomena are a critical element for the development of spintronic and chiroptic devices. Herein we combine a 2D-superlattice perovskite (4,4-DFPD2PbI4) film with a ferromagnetic cobalt (Co) layer to form a multiferroic perovskite/Co interface, and demonstrate spin-switchable circularly polarized luminescence (CPL) between right-handed σ+ and left-handed σ− polarizations. When the ferromagnetic spins of Co at the Co/perovskite interface are altered between positive and negative magnetic field directions, the CPL from the 2D-superlattice perovskite switches from σ+ to σ− polarization. The magnetic field effects present a unique method to confirm that CPL is generated by the circular-orbital momentum of light-emitting excitons within Rashba band structures, eliminating artifacts involving structural birefringence. Our polarized neutron reflectometry measurements confirm a super long-range spin-orbit interaction occurring in the 2D-superlattice perovskite films. The temperature dependence of spin-switchable phenomenon indicates an extraordinarily long orbital polarization lifetime, reaching microseconds at room temperature and milliseconds at 5 K.

36 MATERIALS SCIENCE↗

A Compact Topological Microwave Isolator

A central goal of topological photonics has been to develop compact isolators using protected, non-reciprocal edge states. Furthermore, a recent demonstration of a ferrite-based microwave isolator leverages the magnon-induced topological photonic bandgap to achieve over 100 dB of isolation in a device smaller than a single free-space wavelength.

Magneto-optics↗

Wave steepening and shock formation in ultracold neutral plasmas

We present observations of wave steepening and signatures of shock formation during expansion of ultracold neutral plasmas formed with an initial density distribution that is centrally peaked and decays exponentially with distance. The plasma acceleration and velocity decrease at large distance from the plasma center, leading to central ions overtaking ions in the outer regions and the development of a steepening front that is narrow compared to the size of the plasma. The density and velocity change dramatically across the front, and significant heating of the ions is observed in the region of steepest gradients. For a reasonable estimate of electron temperature, the relative velocity of ions on either side of the front modestly exceeds the local sound speed (Mach number M≳1). This indicates that by sculpting steep density gradients, it is possible to create the conditions for shock formation, or very close to it, opening a new avenue of research for ultracold neutral plasmas.

Computational fluid dynamics↗

Altermagnetic polar metallic phase in ultrathin epitaxially strained RuO 2 films

Altermagnetism refers to a wide class of magnetic orders featuring magnetic sublattices with opposite spins related by rotational symmetries, resulting in nontrivial spin splitting and magnetic multipoles. However, the direct observation of the altermagnetic transition remains elusive. Here, by combining theoretical analysis, electrical transport, X-ray, and optical spectroscopies, we establish a phase diagram in hybrid molecular beam epitaxy-grown RuO 2 /TiO 2 (110) films, mapping symmetries along with altermagnetic/electronic/structural phase transitions as functions of film thickness and temperature. This features an altermagnetic metallic polar phase in epitaxially strained 2 nm films, suggesting a potential link between polar metals and altermagnetic materials. Such a clear signature of a magnetic phase transition at ~500 K is observed exclusively in ultrathin strained films, unlike in bulk RuO 2 single crystals. These results highlight the power of epitaxial heterostructure engineering to induce altermagnetism in systems initially nonmagnetic, opening avenues for realizing emergent quantum phases with multifunctional properties.

RuO2 thin film↗