Search NASA⌕ Search

SEARCH · Search NASA

Results for “mass accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Demonstration of a Lunar Water Extraction and Quantification Technique in a Relevant Environment

The presence of water ice in permanently shadowed regions on the lunar surface may enable a sustained human presence on the Moon with minimal need for consumables. The first step toward utilizing lunar water ice to advance human space exploration will be to determine the abundance, accessibility, and distribution of this valuable resource. This paper will describe the most recent test results from the Light Water Analysis and Volatile Extraction (Light WAVE) system that was designed to capture icy regolith samples acquired from a drill. Regolith samples are then weighed, sealed, and heated to release volatiles. Volatiles are captured in a volume with a known temperature and the ideal gas law is used to determine the total quantity of volatiles in the volume. The composition of the volatile mixture is determined using a mass spectrometer so that each volatile can be quantified. By quantifying the amount of water extracted from the regolith sample, and acquiring the mass of the sample, water concentration by mass can be determined. The goal of recent testing was to determine the accuracy of water quantification using a combination of ideal gas law and mass spectrometer analysis. The Light WAVE system maybe applied to future water ice investigation missions without an inherent limit to the number of samples that can be processed, and the system may also enable lunar water sample return.

Aaron J Paz↗

Astrometric telescope of ten microarcsecond accuracy on the Space Station

The Astrometric Telescope Facility (ATF) will be operated in the NASA Space Station in the 1990s, furnishing long term, highly accurate relative astrometry of nearby stars in order to detect gravitational perturbations by companion stars with masses as small as that of Neptune. An accuracy of 10 microarcsec is required; this is 100 times better than ground observatory performance. In the Gatewood et al. (1980) astrometric technique used, the relative positions of star images in the telescope focal plane are indicated by the relative phases of the modulations of star brightnesses introduced by translating a Ronchi ruling across the focal plane at uniform speed. Space Station vibration damping, fine guiding accuracy, optical configuration, Ronchi ruling metric accuracy, and the choice of detectors, are discussed.

Levy, E. H.↗

High altitude atmospheric modeling

Five empirical models were compared with 13 data sets, including both atmospheric drag-based data and mass spectrometer data. The most recently published model, MSIS-86, was found to be the best model overall with an accuracy around 15 percent. The excellent overall agreement of the mass spectrometer-based MSIS models with the drag data, including both the older data from orbital decay and the newer accelerometer data, suggests that the absolute calibration of the (ensemble of) mass spectrometers and the assumed drag coefficient in the atomic oxygen regime are consistent to 5 percent. This study illustrates a number of reasons for the current accuracy limit such as calibration accuracy and unmodeled trends. Nevertheless, the largest variations in total density in the thermosphere are accounted for, to a very high degree, by existing models. The greatest potential for improvements is in areas where we still have insufficient data (like the lower thermosphere or exosphere), where there are disagreements in technique (such as the exosphere) which can be resolved, or wherever generally more accurate measurements become available.

Hedin, Alan E.↗

Determination of the satellite attitude and its motion about the center of mass

The algorithm requirements for the problem solving and factors determining the accuracy of the solution are analyzed. The types of telemetry data used and the models adopted for the satellite motion about the center of the mass are described. The scheme for the technique used to determine the attitude on the basis of magnetometer data is also discussed.

Khatskevich, I. G.↗

Prospects for strong coupling measurement at hadron colliders using soft-drop jet mass

We compute the soft-drop jet-mass distribution from pp collisions to NNLL accuracy while including nonperturbative corrections through a field-theory based formalism. Using these calculations, we assess the theoretical uncertainties on an αs precision measurement due to higher order perturbative effects, nonperturbative corrections, and PDF uncertainty. We identify which soft-drop parameters are well-suited for measuring αs, and find that higher-logarithmic resummation has a qualitatively important effect on the shape of the jet-mass distribution. We find that quark jets and gluon jets have similar sensitivity to αs, and emphasize that experimentally distinguishing quark and gluon jets is not required for an αs measurement. We conclude that measuring αs to the 10% level is feasible now, and with improvements in theory a 5% level measurement is possible. Getting down to the 1% level to be competitive with other state-of-the-art measurements will be challenging.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design considerations of PSR moderate focus-mission structure

A supporting space-frame has been designed for the segmented panels, secondary reflector, control system, and interface hardware of a near-term Precision Segmented Reflector (PSR) telescope. In addition to meeting areal mass density, vibration frequency, thermal expansion, positioning accuracy, and interface attachment design goals, the PSR structure must withstand Atlas launch loads. Analyses have been conducted of the optical pointing-related structural performance of the Moderate Focus Mission Structure (MFMS), with a view to both mechanical and thermal disturbance analyses; the results indicate that the dynamic responses of the MFMS optical mirrors, due to the chopping disturbance of the secondary reflector about its center-of-mass, are within maintenance sensor requirements.

Shih, Choon-Foo↗

Lunar Topography: Results from the Lunar Orbiter Laser Altimeter

The Lunar Orbiter Laser Altimeter (LOLA) onboard the Lunar Reconnaissance Orbiter (LRO) has been operating nearly continuously since July 2009, accumulating over 6 billion measurements from more than 2 billion in-orbit laser shots. LRO's near-polar orbit results in very high data density in the immediate vicinity of the lunar poles, with full coverage at the equator from more than 12000 orbital tracks averaging less than 1 km in spacing at the equator. LRO has obtained a global geodetic model of the lunar topography with 50-meter horizontal and 1-m radial accuracy in a lunar center-of-mass coordinate system, with profiles of topography at 20-m horizontal resolution, and 0.1-m vertical precision. LOLA also provides measurements of reflectivity and surface roughness down to its 5-m laser spot size. With these data LOLA has measured the shape of all lunar craters 20 km and larger. In the proposed extended mission commencing late in 2012, LOLA will concentrate observations in the Southern Hemisphere, improving the density of the polar coverage to nearly 10-m pixel resolution and accuracy to better than 20 m total position error. Uses for these data include mission planning and targeting, illumination studies, geodetic control of images, as well as lunar geology and geophysics. Further improvements in geodetic accuracy are anticipated from the use of re ned gravity fields after the successful completion of the Gravity Recovery and Interior Laboratory (GRAIL) mission in 2012.

Neumann, Gregory↗

Apollo oxygen tank stratification analysis, volume 2

An analysis of flight performance of the Apollo 15 cryogenic oxygen tanks was conducted with the variable grid stratification math model developed earlier in the program. Flight conditions investigated were the CMP-EVA and one passive thermal control period which exhibited heater temperature characteristics not previously observed. Heater temperatures for these periods were simulated with the math model using flight acceleration data. Simulation results (heater temperature and tank pressure) compared favorably with the Apollo 15 flight data, and it was concluded that tank performance was nominal. Math model modifications were also made to improve the simulation accuracy. The modifications included the addition of the effects of the tank wall thermal mass and an improved system flow distribution model. The modifications improved the accuracy of simulated pressure response based on comparisons with flight data.

Barton, J. E.↗

Particulate matter sensor

Microfabricated PM sensors measure concentrations of particulate matter (PM) in air. Some sensors improve the accuracy of measurements by accounting for the effect of ambient conditions (e.g., temperature or humidity) on mass-sensitive elements employed to determine a mass of the PM in a stream of air. Some sensors improve the accuracy of measurements by controlling humidity in the stream of air measured by mass-sensitive elements. Some sensors employ a plurality of mass-sensitive elements to extend the useful life of the PM sensor. Some sensors employ one or more mass-sensitive elements and heating elements to cause deposition and allow measurement of different sizes of PM. Some sensors can measure mass concentration of coarse PM in addition to fine PM in a stream of air. Some sensors control the flow rate of a stream of air measured by mass-sensitive elements. Some sensors include features to mitigate electromagnetic interference or electromagnetic signal loss.

Paprotny, Igor↗

Radial velocities of very low mass stars and candidate brown dwarf members of the Hyades and Pleiades

We have determined H alpha equivalent widths and radial velocities with 1 sigma accuracies of approximately 5 km s(exp -1) for approximately 20 candidate very low mass members of the Hyades and Pleiades clusters. The radial velocities for the Hyades sample suggest that nearly all of these stars are indeed highly probable members of the Hyades. The faintest stars in the Hyades sample have masses of order 0.1 solar mass. We also obtained radial velocities for four candidate very low mass members of the Pleiades and two objects that are candidate BD Pleiads. All of these stars have apparent V magnitudes fainter than the Hyades stars we observed, and the resultant radial velocity accuracy is worse. We believe that the three brighter stars are indeed likely very low mass stellar members of the Pleiades, whereas the status of the two brown dwarf candidates is uncertain. The Hyades stars we have observed and the three Pleiades very low mass stars are the lowest mass members of any open cluster whose membership has been confirmed by radial velocities and whose chromospheric activity has been measured. We see no change in chromospheric activity at the boundary where stars are expected to become fully convective (M approximately equals 0.3 solar mass) in either cluster. In the Pleiades, however, there may be a decrease in chromospheric activity for stars with (V-I)(sub K) greater than 3.5 (M less than or equal to 0.1 solar mass).

Stauffer, John R.↗

Cryo-Gearbox Using Bulk Metallic Glasses

Harmonic drives are a highly efficient and compact gearing technology that are widely used in robotics and aerospace applications (e.g. Mars Science Lab) due to their excellent torque-to-mass ratio, low backlash, and high positional accuracy. One major problem using any gearing on other planetary bodies is the need for heaters to keep the gearbox from freezing. Currently the Mars Science Lab uses 40% of its daily power output to operate heaters to keep the grease in the gearboxes from freezing. Also wear can limit the lifetime and performance of these systems. One possible solution to this problem could be to use a relatively new material known as Bulk Metallic Glasses (BMGs, also known as Amorphous Metals). BMGs are non-crystalline metallic alloys that exhibit superior mechanical properties. Compared to modern aerospace steels BMGs have a higher strength, higher elastic limit, and lower density. BMGs used in harmonic drives (especially the flex spline) could lead to longer system lifetimes, lower mass, and increased performance. Jet Propulsion Laboratory (JPL) is researching a new method of manufacturing the flex spline by injection molding and is hoping to have reduced costs as well as the benefits listed above. In conjunction with Kennedy Space Center (KSC), JPL is providing gearboxes that KSC will test greaseless in an extreme environment. KSC has completed the assembly and checkout of a test stand that is capable of testing a gearbox in a vacuum of less than 2 milli torr, 100 Kelvin temperature, 250 Nm of load, input and output torque measurements and 120 RPM input speed.

Drew Smith↗

Contributions to the BeEST sterile neutrino search

Sterile neutrinos are hypothetical right-handed leptons that have been postulated as extensions to the Standard Model to help explain the origin of neutrino masses and the matter-antimatter asymmetry in the Universe. Sterile neutrinos with keV-scale masses are also a promising candidate for dark matter. LLNL and the Colorado School of Mines are developing an experiment to search for sterile neutrinos by measuring the \Beryllium-7 Electron capture in Superconducting Tunnel junctions (STJs)" (the \BeEST" Experiment). When 7 Be implanted into STJ radiation detectors decays by electron capture, the neutrino escapes and the energy of the recoiling 7 Li nucleus can be measured with high accuracy. Using conservation of energy and momentum, the mass of the emitted neutrino can then be found. Sterile keV neutrinos would generate additional peaks in the spectrum, and the experiment uses high-resolution STJs to observe such a potential signal. During my internship, I contributed to different aspects of the BeEST experiment. I designed a UHV setup for X-ray spectroscopy analysis with STJs. It will allow high-resolution X-ray spectroscopy of different materials to examine the broadening in the BeEST spectra, the origins of which are unknown but may be related to material effects inside the STJ detectors. The design accounts for the specific demands of the BeEST project, but provides a degree of flexibility that makes it useful for other potential STJ projects. Additionally, to test the accuracy of the electronics and data analysis routine, an arbitrary waveform generator (AWG) will be used to generate simulated spectra that contain sterile neutrino signals of a specified mass and admixture. For this I programmed an AWG to output random STJ signals whose amplitudes follow the appropriate user-de ned probability distribution. The AWG signals can be input into the 32-channel preamplifier to simulate any spectrum of interest and test the uniformity of the amplifier chain, as well as the sensitivity of the data analysis.

42 ENGINEERING↗

Satellite measurement of mass of Sahara dust in the atmosphere

Landsat 1 measurements of nadir radiance are used to obtain the mass of particulates in a vertical column of dust from the Sahara Desert. A radiative transfer model, constructed with knowledge of a few values of optical parameters measured from a ship, is developed to account for the measured radiance values. Measurement and model accuracies are discussed. It is found that the mass of particulates with smaller than a 10 micron radius in a vertical column is 1.6 g/sq m.

Fraser, R. S.↗

Proposal to Simultaneously Profile Wind and CO2 on Earth and Mars With 2-micron Pulsed Lidar Technologies

2-micron lidar technology has been in use and under continued improvement for many years toward wind measurements. But the 2-micron wavelength region is also rich in absorption lines of CO2 (and H2O to a lesser extent) that can be exploited with the differential absorption lidar (DIAL) technique to make species concentration measurements. A coherent detection receiver offers the possibility of making combined wind and DIAL measurements with wind derived from frequency shift of the backscatter spectrum and species concentration derived from power of the backscatter spectrum. A combined wind and CO2 measurement capability is of interest for applications on both Earth and Mars. CO2 measurements in the Earth atmosphere are of importance to studies of the global carbon cycle. Data on vertically-resolved CO2 profiles over large geographical observations areas are of particular interest that could potentially be made by deploying a lidar on an aircraft or satellite. By combining CO2 concentration with wind measurements an even more useful data product could be obtained in the calculation of CO2 flux. A challenge to lidar in this application is that CO2 concentration measurements must be made with a high level of precision and accuracy to better than 1%. The Martian atmosphere also presents wind and CO2 measurement problems that could be met with a combined DIAL/Doppler lidar. CO2 concentration in this scenario would be used to calculate atmospheric density since the Martian atmosphere is composed of 95% CO2. The lack of measurements of Mars atmospheric density in the 30-60 km range, dust storm formation and movements, and horizontal wind patterns in the 0-20 km range pose significant risks to aerocapture, and entry, descent, and landing of future robotic and human Mars missions. Systematic measurement of the Mars atmospheric density and winds will be required over several Mars years, supplemented with day-of-entry operational measurements. To date, there have been 5 successful robotic landings on Mars. Atmospheric density and wind reconstruction has been performed for 3 of these entries (the two Viking landers and Mars Pathfinder). At present, all Mars atmospheric density and wind models have these 3 entries (at widely scattered positions and seasons) as their basis, supplemented by coarse orbital measurements of atmospheric opacity and temperature. This lack of data leads to a large uncertainty in prediction of the Mars atmospheric density and winds in the altitude regime where deceleration of landers will occur. This uncertainty will have a dramatically large impact on mass, cost and risk. The precision and accuracy for application to Mars is not as stringent as Earth, but Mars does pose a challenge in needing a high level of wavelength stability and control in order to reference wavelength to the narrow linewidths found in the low atmospheric pressure of Mars, as illustrated in Figure 1.

Singh, Upendra N.↗

Experimental measurement of the effective contact angle for solvent/packing interactions in a structured packed column for CO 2 capture

The contact angle is a critical factor for determining the effective mass transfer area for carbon dioxide (CO 2 ) capture via the chemical absorption process in a packed column, and thus the overall capture efficiency of the packed column. Many widely used commercial packings involve microscale features (perforation, corrugation, etc.) that may also affect the wetting behavior. This study proposes a systematic method of using a modified Wilhelmy plate to measure the effective contact angle to characterize the solvent and featured packing interaction. In lieu of computational efforts relying on assumptions guided by semi-informed correlation, the proposed method directly measures the effective contact angle as a function of the solvent and packing thermophysical and hydrodynamic properties. The characterization of the effective contact angle is then integrated in the computational fluid dynamics modeling to reduce uncertainty in the prediction of effective mas transfer area. Experiments were conducted for stainless steel coupons using water and aqueous sodium hydroxide (NaOH) solvent for verification of the proposed experimental protocol. The surface tension of the aqueous NaOH solvent was altered using surfactant and antifoam. The effective contact angle increases with the increased value of the surface tension for flat stainless steel sheets. On the other hand, effective contact angles do not vary in Mellapak coupons for aqueous monoethanolamine (MEA) and NaOH solvent. In this case, surface textures and sheet design play a dominant role in the surface tension of solvents. Furthermore, CO 2 loading has a significant effect on the contact angle for Mellapak coupons. As expected, the contact angle decreases with the increasing temperature of CO 2 capture solvents (MEA, EEMPA). The effective contact angle measurement using the Wilhelmy plate method can provide more accurate and efficient solvents for characterizing the solvent-packing surface interactions. Subsequently, the present method enhances the accuracy of the prediction of the effective mass transfer area in carbon capture by solvent absorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radial velocities of very low mass stars and candidate brown dwarf members of the Hyades and Pleiades, 2

We have determined H alpha equivalent widths and radial velocities with 1 sigma accuracies of approximately 5 km/s for approximately 20 candidate very low mass members of the Pleiades cluster and for a few proposed very low mass members of the Hyades. Most of the Pleiades targets were selected from the recent Hambly, Hawkins, and Jameson proper motion survey, where they were identified as probable Pleiades brown dwarfs with an age spread from 3 to 70 Myr. Our spectroscopic data and a reinterpretation of the photometric data confirm that these objects are indeed likely Pleiades members; however, we believe that they more likely have masses slightly above the hydrogen burning mass limit and that there is no firm evidence for an age spread amongst these stars. All of the very low mass Pleiades and Hyades members show H alpha in emission. However, the ratio of H alpha flux to biometric flux in the Pleiades shows a maximum near M(sub Bol) approximately equal to 9.5 (M approximately equal to 0.3 solar mass) and a sharp decrease to lower masses. This break occurs at the approximate mass where low mass stars are expected to become fully convective, and it is tempting to assume that the decrease in H alpha flux is caused by some change in the behavior of stellar dynamos at this mass. We do not see a similar break in activity at this mass in the Hyades. We discuss possible evolutionary explanations for this difference in the H alpha activity between the two clusters.

Stauffer, John R.↗

Cluster infall for mass calibration in the stage-IV era

The outskirts of galaxy clusters present a promising avenue for constraining cluster masses in a way that is robust to the impact of baryonic physics. We assess the accuracy to which the cluster infall regions can be used for cluster mass calibration. Building on previous work, we parametrize the velocity distribution 𝑃⁡(𝑣r,𝑣tan|𝑟,𝑀) of dark matter halos on scales 𝑟 ≥ 5⁢ℎ −1 Mpc as the product of the marginalized distribution 𝑃⁡(𝑣 r |𝑟,𝑀) and the conditional distribution 𝑃⁡(𝑣 tan |𝑣 r ,𝑟,𝑀), calibrating the radial and mass dependence of these distributions in numerical simulations. We then project our model along the line of sight to obtain accurate predictions for the distributions of line-of-sight velocities at a given projected radius and cluster mass 𝑃⁡(𝑣 LOS |𝑅,𝑀), which we can observe with spectroscopic survey data. Furthermore, with our model, we forecast that spectra from the Dark Energy Spectroscopic Instrument can constrain cluster masses with subpercent-level precision, comparable to that of stage-IV weak lensing surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Dual-Biometric Human Identification Using Radar Deep Transfer Learning

Accurate human identification using radar has a variety of potential applications, such as surveillance, access control and security checkpoints. Nevertheless, radar-based human identification has been limited to a few motion-based biometrics that are solely reliant on micro-Doppler signatures. This paper proposes for the first time the use of combined radar-based heart sound and gait signals as biometrics for human identification. The proposed methodology starts by converting the extracted biometric signatures collected from 18 subjects to images, and then an image augmentation technique is applied and the deep transfer learning is used to classify each subject. A validation accuracy of 58.7% and 96% is reported for the heart sound and gait biometrics, respectively. Next, the identification results of the two biometrics are combined using the joint probability mass function (PMF) method to report a 98% identification accuracy. To the best of our knowledge, this is the highest reported in the literature to date. Lastly, the trained networks are tested in an actual scenario while being used in an office access control platform to identify different human subjects. We report an accuracy of 76.25%.

47 OTHER INSTRUMENTATION↗