Search NASA⌕ Search

SEARCH · Search NASA

Results for “mass spectra”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Cirrus microphysics observations made during FIRE 2: Small particles, high concentrations, and probe comparisons

Aircraft observations of cirrus cloud microphysics were made near Coffeyville, Kansas during Nov. and Dec. 1991. Cloud microphysics measurements were made using both a PMS 2DC probe and an ice particle replicator, both were mounted on the UND Citation aircraft. Intercomparison is made of the size, area, and ice mass spectra determined from these probes. The PMS 2DC undercounts particles for D less than 70 microns and the replicator oversizes particles for D greater than 150 microns, at least when column rosettes are encountered. High concentrations of particles with D less than 50 microns are noted in selected portions of the 22 Nov. 91 replicator data set. Relations between the maximum dimension of a crystal and its shadow area (known as area dimensional relationships) are computed from the PMS data. Area and mass dimensional relationships are used to give a simple analytical expression for computing the wavelength dependent absorption coefficient averaged over a size bin. Calculations based upon the replicator data show that crystals with D less than 50 microns contribute significantly to the solar extinction and infrared absorption coefficients during some time intervals.

Arnott, W. P.↗

Assessment of Impurities in Neptunium Metal Using Double-Focusing SF-ICP-MS

In the transmutation process, minor actinides such as neptunium, americium and curium obtained from spent nuclear fuel are incorporated into new fuel that can be placed into a fast reactor, where these elements fission into products with shorter half-lives which reduces the health and safety hazards. In order to better understand the all the involved processes, fundamental physical properties of actinides should be investigated, and for that reason, high-purity materials need to be produced. One of the main challenges in characterizing these materials is the lack of pure metal available for study, and lack of analytical methods to determine the purity. Trans-uranic elements are challenging to study because of the need to be handled in specialized facilities, safeguards concerns and they are not easily purchased and/or produced. High-purity Np metal is being produced at the Materials and Fuels Complex (MFC) of Idaho National Laboratory (INL), in a process of direct oxide reduction developed by Squires and Lessing, with a target purity of 99.999%. The goal of this research is to develop methods to determine the impurities in the Np metal, with detection limits low enough to achieve this purity level. In this work, we have used several ICP-MS and ICP OES techniques, but the focus was the method development using a recently acquired Double-Focusing Sector Field Inductively Coupled Plasma Mass Spectrometer (SF-ICP-MS). To produce the Np metal, approximately 20 g of the neptunium oxide powder was calcined at 800 oC for 6 h in a magnesium oxide crucible, which is placed inside a stainless steel crucible, that goes into the Hot Uniaxial Press (HUP) furnace insert. After the calcining step, the Np oxide was mixed with approximately 9 g of calcium metal and 100 g of ultra-dry calcium chloride. The HUP furnace was heated in a ramp rate of 50 oC min -1 up to 1000 oC. When the reaction mixture reached 850 oC, a tantalum stirrer was activated at 100 rpm. After the tantalum stirrer was removed and the mixture cooled overnight, the MgO crucible was opened with a hammer and chisel to retrieve the Np metal button at the bottom of the reaction mixture. Prior to the dissolution process, the surface contaminants of the sample were removed. The Np button was washed in 10 mL of ultra-pure water for 1 min, with a faint reaction observed on the surface, indicating the presence of Ca metal. The water-washed sample was placed in a tube with 2 M HCl for only 3 s, as a vigorous reaction in the button surface was observed. The leachates were saved for further analysis. The sample was then rinsed with ultra-pure water and air-dried prior to dissolution. The cleaned sample was placed in a PTFE beaker and 25 mL of 6 M HCl and 150 µL of 24 M HF were added. After 10 minutes of reaction, the beaker was placed on a hot plate for 1 h and 30 min, followed by the addition of 1 mL of 16 M HNO3 and allowed to react for a further 1 h and 20 min. The sample was removed from heat and 10 mL of HNO3 16 M was added to react with the HCl. The beaker was covered and left for overnight reaction, producing a solution with approximately 20 mL of final volume. A Quadrupole Inductively Coupled Plasma Mass Spectrometer (Q-ICP-MS, Perkin Elmer ELAN DRC II Q-ICP-MS) was used to obtain qualitative mass spectra for the dissolution blank, each of the leachates and the dissolved sample. In the water leachate spectrum mainly Ca and Mg were observed, while the acid wash had a similar peak pattern to the one observed for the Np metal sample, indicating that the process not only removed surface contamination, but also reacted with the sample itself. In the Np material spectrum, Ta and actinides were identified as candidates for major contaminants, as the most intense peaks corresponded to the mass-to-charge ratios of these elements. Minor contaminants included Al, Au, Ca, Cr, Fe, I, Na, Nb, Pb, Sn, Ti, Tl, V, Y. The presence of impurities in the material could have originated from several sources, such as the materials used for the casting process, the use of impure NpO2 or contamination of reagents and materials used for the analysis. Some of the isotopes listed as potential contaminants are susceptible to spectral interferences, so Double-Focusing SF-ICP-MS (Nu Instruments Attom ES HR-ICP-MS) was used for the quantitative analysis. For each isotope determined, several items were evaluated: raw signal of a blank solution, sensitivity and determination coefficient of calibration curves, possibility of interferences and comparison of results obtained for at least two resolving powers (RP): 300 and 4000. The evaluation of the signal in a blank solution can indicate if a spectral interference from the plasma gas and/or the solvent was successfully resolved (commonly observed for 52Cr+/40Ar12C+, for example). It is important to highlight that a signal reduction is expected when a higher RP is used, as the ion beam transmission is decreased by the use of narrower slits

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigating Covalent Bonding in f-elements using Gas-phase Ion Chemistry

Introduction In the reprocessing of f-elements present in used nuclear fuels, a variety of diglycolamides (DGA’s) are used as extractants for actinide partitioning. In particular, the Actinide-Lanthanide Separation (ALSEP) process typically utilizes either the N,N,N’,N’-tetraoctyl diglycolamide (TODGA) or N,N,N',N'-tetra-2-ethylhexyl diglycolamide (T2EHDGA) extractant ligands following the partitioning of uranium and plutonium from used nuclear fuel. To better understand fundamental interactions in these processes, covalent bonding of several f-elements with diglycolamides, primarily TODGA, is investigated in the gas phase using nanospray ionization and a quadrupole time-of-flight mass spectrometer. Further, analysis of the identity and relative strength of the cluster is enabled by MS2 isolation and collision induced dissociation. Methods Metal ion cluster analysis was completed using a Bruker mircOTOF-Q II quadrupole time-of-flight mass spectrometer equipped with a CaptiveSpray nanospray ion source. Metal:ligand solutions were prepared as 30 µM europium nitrate, samarium nitrate, cerium nitrate, or holmium nitrate and 3 µM DGA in acetonitrile or a 50:50 mixture of acetonitrile: isopropanol. Cluster mass spectra and collision-induced dissociation experiments were conducted in positive mode. Preliminary data To examine the patterns and relative strength of lanthanide: DGA interactions, MS2 experiments were completed with each lanthanide species listed above. Preliminary analyses of samarium and europium TODGA clusters suggest several combinations of TODGA and nitrate forming. The samarium cluster experiments yielded Sm(TODGA)x clusters with a samarium:TODGA ratio of up to 1:7 able to be isolated and evidence of greater ratios present in the mass spectrum. This is surprising, as metal clusters are not expected to have a coordination space able to accommodate this many ligands as large as TODGA. MS2 experiments show that, at higher ratios and with sufficient collision energy, entire TODGA ligands are removed instead of being fragmented. These experiments show that a lower collision energy is required to remove ligands as the number of bound TODGA’s increases, suggesting that in larger clusters, ligands are more delicately complexed to the metal. In addition to Sm(TODGA)x, several clusters were observed with nitrate ions bound to the metal in addition to TODGA. With a single nitrate ion, clusters with up to six TODGA’s were able to be isolated. In a similar pattern to the samarium clusters with only TODGA, less collision energy is required to eliminate one or more TODGA’s with increasing size. MS2 experiments suggest clusters with one nitrate appear to be of an equivalent or greater stability to clusters which replace the nitrate with a TODGA, as more collision energy is required to remove a TODGA ligand. These species with one nitrate are also in a higher abundance than the equivalent TODGA only cluster. With two nitrate ions, only clusters with a single TODGA were able to be isolated. Analogous europium experiments resulted in very similar clusters. Ratios of up to 1:7 Eu:TODGA were able to be isolated, and clusters with one nitrate and up to five TODGAs were isolated. In clusters with two nitrate ions, one or two TODGA’s could also be bound to the metal. MS2 experiments suggested, similarly to samarium, that larger clusters required less collision energy to eliminate TODGA. Europium clusters with one nitrate are in greater abundance and are stronger than the equivalent cluster which replaces the nitrate with TODGA. Similar analysis with cerium and holmium is ongoing, as well as analysis with other DGA ligands to compare relative strengths of the lanthanide metals with various extractant ligands.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Observations of VOC Emissions and Photochemical Products over US Oil- and Gas-Producing Regions Using High-Resolution H3O+ CIMS (PTR-ToF-MS)

VOCs (Volatile Organic Compounds) related to oil and gas extraction operations in the United States were measured by H3O (sup plus) chemical ionization time-of-flight mass spectrometry (H3O (sup plus) ToFCIMS/PTR-ToF-MS (Time of Flight Chemical Ionization Mass Spectrometry/Proton Transfer Reaction-Time of Flight-Mass Spectroscopy) from aircraft during the Shale Oil and Natural Gas Nexus (SONGNEX) campaign in March-April 2015. This work presents an overview of major VOC species measured in nine oil- and gas-producing regions, and a more detailed analysis of H3O (sup plus) ToF-CIMS measurements in the Permian Basin within Texas and New Mexico. Mass spectra are dominated by small photochemically produced oxygenates and compounds typically found in crude oil: aromatics, cyclic alkanes, and alkanes. Mixing ratios of aromatics were frequently as high as those measured downwind of large urban areas. In the Permian, the H3O (sup plus) ToF-CIMS measured a number of underexplored or previously unreported species, including aromatic and cycloalkane oxidation products, nitrogen heterocycles including pyrrole (C4H5N) and pyrroline (C4H7N), H2S, and a diamondoid (adamantane) or unusual monoterpene. We additionally assess the specificity of a number of ion masses resulting from H3O (sup plus) ion chemistry previously reported in the literature, including several new or alternate interpretations.

mass spectrometr↗

Search for dijet resonances with data scouting in proton-proton collisions at $\sqrt{s}=13$ TeV

A search is presented for narrow resonances, with a mass between 0.6 and 1.8 TeV, decaying to pairs of jets, in proton-proton collisions at $\sqrt{s}=13$ TeV. The search is performed using dijets that are reconstructed, selected, and recorded in a compact form by the high-level trigger in a technique referred to as “data scouting”, from data collected in 2016–2018 corresponding to an integrated luminosity of 117 fb −1 . The dijet mass spectra are well described by a smooth parameterization, and no significant evidence for the production of new particles is observed. Model-independent upper limits are presented on the product of the cross section, branching fraction, and acceptance for the individual cases of narrow quark-quark, quark-gluon, and gluon-gluon resonances, and are compared to the predictions from a variety of models of narrow dijet resonance production. The upper limit on the coupling of a dark matter mediator to quarks is presented as a function of the mediator mass. The sensitivity of this search goes beyond what is expected from statistical scaling with the integrated luminosity alone, as a consequence of the use of fewer parameters in the background function within a more robust statistical procedure.

beyond Standard Model↗

International Space Station (ISS) Environmental Control and Life Support System (ECLSS) Vent Flow Reflection and Detection by Robotic External Leak Locator (RELL)

On-orbit Robotic External Leak Locator (RELL) (i.e., mass spectrometer and ion gauge) measurements on the International Space Station (ISS) are presented to show the detection of recurring Environmental Control and Life Support System (ECLSS) vents at multiple ISS locations and RELL pointing directions. The path of ECLSS effluents to the RELL detectors is not entirely obvious at some locations, but the data indicates that diffuse gas-surface reflection or scattering resulting from plume interaction with vehicle surfaces is responsible. RELL was also able to confirm the ISS ECLSS constituents and distinguish them from the ammonia leak based on the ion mass spectra and known venting times during its operation to locate a leak in the ISS port-side External Active Thermal Control System (EATCS) coolant loop.

Gas/Surface Reflections or Scattering↗

Sputtering of sulfur by kiloelectronvolt ions - Application to the magnetospheric plasma interaction with Io

Accurate measurements of the yields, mass spectra, and energy spectra of ejected sulfur are presented based on vapor deposits of sulfur at temperatures and ion energies relevant to the plasma interaction with the surface of Io. The measured sputtering yields are much lower than previous estimates for room temperature sulfur films, but are comparable to previous measurements of low-temperature keV ion sputtering of SO2. Results suggest that if ions reach the surface of Io its atmosphere will have a nonnegligible sulfur component which is primarily S2. Comparison of injection rates determined for sulfur with those for SO2 indicates that injection from sulfur deposits contributes 13 percent to the total mass injection rate of about 2-3 x 10 to the 29th amu/sec.

Chrisey, D. B.↗

Coherence mapping to identify the intermediates of multi-channel dissociative ionization

Identifying the short-lived intermediates and reaction mechanisms of multi-channel radical cation fragmentation processes remains a current and important challenge to understanding and predicting mass spectra. We find that coherent oscillations in the femtosecond time-dependent yields of several product ions following ultrafast strong-field ionization represent spectroscopic signatures that elucidate their mechanism of formation and identify the intermediate(s) they originate from. Experiments on endo-dicyclopentadiene show that vibrational frequencies from various intermediates are mapped onto their resulting products. Aided by ab initio methods, we identify the vibrational modes of both the cleaved and intact molecular ion intermediates. These results confirm stepwise and concerted fragmentation pathways of the dicyclopentadiene ion. This study highlights the power of tracking the femtosecond dynamics of all product ions simultaneously and sheds further light onto one of the fundamental reaction mechanisms in mass spectrometry, the retro-Diels Alder reaction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The ABC of RPV: classification of R-parity violating signatures at the LHC for small couplings

We perform a classification of all potential supersymmetric R-parity violating signatures at the LHC to address the question: are existing bounds on supersymmetric models robust, or are there still signatures not covered by existing searches, allowing LHC scale supersymmetry to be hiding? We analyze all possible scenarios with one dominant RPV trilinear coupling at a time, allowing for arbitrary LSPs and mass spectra. We consider direct production of the LSP, as well as production via gauge-cascades, and find 6 different experimental signatures for the $LL\overline{E}$-case, 6 for the $LQ\overline{D}$-case, and 5 for the $\overline{U}$ $\overline{D}$ $\overline{D}$-case; together these provide complete coverage of the RPV-MSSM landscape. This set of signatures is confronted with the existing searches by ATLAS and CMS. We find all signatures have been covered at the LHC, although not at the sensitivity level needed to probe the direct production of all LSP types. For the case of a dominant $LL\overline{E}$-operator, we use CheckMATE to quantify the current lower bounds on the supersymmetric masses and find the limits to be comparable to or better than the R-parity conserving case. Our treatment can be easily extended to scenarios with more than one non-zero RPV coupling.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for supersymmetry using vector boson fusion signatures and missing transverse momentum in pp collisions at $\sqrt{s}$ = 13 TeV with the ATLAS detector

This paper presents a search for supersymmetric particles in models with highly compressed mass spectra, in events consistent with being produced through vector boson fusion. The search uses 140 fb −1 of proton-proton collision data at $\sqrt{s}$ = 13 TeV collected by the ATLAS experiment at the Large Hadron Collider. Events containing at least two jets with a large gap in pseudorapidity, large missing transverse momentum, and no reconstructed leptons are selected. A boosted decision tree is used to separate events consistent with the production of supersymmetric particles from those due to Standard Model backgrounds. The data are found to be consistent with Standard Model predictions. The results are interpreted using simplified models of R-parity-conserving supersymmetry in which the lightest supersymmetric partner is a bino-like neutralino with a mass similar to that of the lightest chargino and second-to-lightest neutralino, both of which are wino-like. Lower limits at 95% confidence level on the masses of next-to-lightest supersymmetric partners in this simplified model are established between 117 and 120 GeV when the lightest supersymmetric partners are within 1 GeV in mass.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of charmonium decays to K S 0 K π in the B → ( K S 0 K π ) K channels

A study of the B + → $K^0_S$K + K - π + and B + → $K^0_S$K + K + π - decays is performed using proton-proton collisions at center-of-mass energies of 7, 8 and 13 TeV at the LHCb experiment. The $K^0_S$Kπ invariant mass spectra from both decay modes reveal a rich content of charmonium resonances. New precise measurements of the η c and η c (2S) resonance parameters are performed and branching fraction measurements are obtained for B + decays to η c , J/ψ, η c (2S) and χ c1 resonances. In particular, the first observation and branching fraction measurement of B + → χ c0 K 0 π + is reported as well as first measurements of the B + → K 0 K + K - π + and B + → K 0 K + K - π + branching fractions. Dalitz plot analyses of η c → $K^0_S$Kπ and η c (2S) → $K^0_S$Kπ decays are performed. A new measurement of the amplitude and phase of the Kπ S-wave as functions of the Kπ mass is performed, together with measurements of the $K^*_0$(1430), $K^*_0$(1950) and a 0 (1700) parameters. Finally, the branching fractions of χ c1 decays to K* resonances are also measured.

79 ASTRONOMY AND ASTROPHYSICS↗

Absolute mass calibration of fission product distributions measured with the E-$v$ method

The mass calibration of fission product distributions measured with the energy–velocity (E-v) method constitutes a technical challenge. The energy loss of the fission fragments in the various dead layers of the spectrometer and other sources of pulse-height defects of the energy detectors are a significant source of systematic uncertainty in the mass calculations used to determine the measured fission product yields. Here, in this study, the absolute calibration of the fission mass distributions is accomplished by measuring prompt γ-rays in coincidence with the fission fragments. This allows for the direct calibration of the mass spectra and eliminates any dependence on potentially complicated energy corrections. The first test measurement was performed at the Los Alamos Neutron Science Center employing the SPectrometer for Ion DEtermination in fission Research (SPIDER). SPIDER is a 2E-2v spectrometer designed for measuring independent fission product yields from neutron-induced fission. In this test, the single-arm SPIDER (E-v) system and an array of 252 Cf sources were used. The single-arm system consisted of two time pick-off detectors for measuring the time-of-flight of the fission fragments and a double-sided silicon strip detector (DSSD) for measuring the kinetic energy. Characteristic γ-rays from fission fragments were detected using three high-purity germanium (HPGe) detectors. For the mass calibration, γ–mass coincidence events from twelve product isotopes were used. The measured FPYs from 252 Cf spontaneous fission were found to be in excellent agreement with the evaluated data after applying the absolute mass calibration. From the γ–mass coincidence events, the mass resolution of the system was also extracted. An average mass resolution of ~1.4 AMU (FWHM) for the light fragments and ~2.4 AMU (FWHM) for the heavy fragments were found. This was the first in-situ calibration and characterization of the SPIDER spectrometer, which paves the way for high-quality FPY measurements with this instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling the Enceladus dust plume based on in situ measurements performed with the Cassini Cosmic Dust Analyzer

We analyzed data recorded by the Cosmic Dust Analyzer on board the Cassini spacecraft during Enceladus dust plume traversals. Our focus was on profiles of relative abundances of grains of different compositional types derived from mass spectra recorded with the Dust Analyzer subsystem during the Cassini flybys E5 and E17. The E5 profile, corresponding to a steep and fast traversal of the plume, has already been analyzed. In this paper, we included a second profile from the E17 flyby involving a nearly horizontal traversal of the south polar terrain at a significantly lower velocity. Additionally, we incorporated dust detection rates from the High Rate Detector subsystem during flybys E7 and E21. We derived grain size ranges in the different observational data sets and used these data to constrain parameters for a new dust plume model. This model was constructed using a mathematical description of dust ejection implemented in the software package DUDI. Further constraints included published velocities of gas ejection, positions of gas and dust jets, and the mass production rate of the plume. Our model employs two different types of sources: diffuse sources of dust ejected with a lower velocity and jets with a faster and more colimated emission. From our model, we derived dust mass production rates for different compositional grain types, amounting to at least 28 kg s –1 . Previously, salt-rich dust was believed to dominate the plume mass based on E5 data alone. The E17 profile shows a dominance of organic-enriched grains over the south polar terrain, a region not well constrained by E5 data. By including both E5 and E17 profiles, we find the salt-rich dust contribution to be at most 1% by mass. This revision also results from an improved understanding of grain masses of various compositional types that implies smaller sizes for salt-rich grains. Our new model can predict grain numbers and masses for future mission detectors during plume traversals.

79 ASTRONOMY AND ASTROPHYSICS↗

Nucleation of soot: experimental assessment of the role of polycyclic aromatic hydrocarbon (PAH) dimers

The irreversible dimerization of polycyclic aromatic hydrocarbons (PAHs) – typically pyrene (C 16 H 10 ) dimerization – is widely used in combustion chemistry models to describe the soot particle inception step. This study concerns itself with the detection and identification of dimers of flame-synthesized PAH radicals and closed-shell molecules and an experimental assessment of the role of these PAH dimers for the nucleation of soot. To this end, flame-generated species were extracted from an inverse co-flow flame of ethylene at atmospheric pressure and immediately diluted with excess nitrogen before the mixture was analyzed using flame-sampling tandem mass spectrometry with collision-induced fragmentation. Signal at m/z = 404.157 (C 32 H 20 ) and m/z = 452.157 (C 36 H 20 ) were detected and identified as dimers of closed-shell C 16 H 10 and C 18 H 10 monomers, respectively. A complex between a C 13 H 9 radical and a C 24 H 12 closed-shell PAH was observed at m/z = 465.164 (C 37 H 21 ). However, a rigorous analysis of the flame-sampled mass spectra as a function of the dilution ratio, defined as the ratio of the flow rates of the diluent nitrogen to the sampled gases, indicates that the observed dimers are not flame-born, but are produced in the sampling line. In agreement with theoretical considerations, this paper provides experimental evidence that pyrene dimers cannot be a key intermediate in particle inception at elevated flame temperatures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

BLINK enables ultrafast tandem mass spectrometry cosine similarity scoring

Metabolomics has a long history of using cosine similarity to match experimental tandem mass spectra to databases for compound identification. Here we introduce the Blur-and-Link (BLINK) approach for scoring cosine similarity. By bypassing fragment alignment and simultaneously scoring all pairs of spectra using sparse matrix operations, BLINK is over 3000 times faster than MatchMS, a widely used loop-based alignment and scoring implementation. Using a similarity cutoff of 0.7, BLINK and MatchMS had practically equivalent identification agreement, and greater than 99% of their scores and matching ion counts were identical. This performance improvement can enable calculations to be performed that would typically be limited by time and available computational resources.

47 OTHER INSTRUMENTATION↗

Intact mass spectrometry screening to optimize hydroxyl radical dose for protein footprinting

Hydroxyl radical protein footprinting (HRPF) using synchrotron radiation is a well-validated method to assess protein structure in the native solution state. In this method, X-ray radiolysis of water generates hydroxyl radicals that can react with solvent accessible side chains of proteins, with mass spectrometry used to detect the resulting labeled products. An ideal footprinting dose provides sufficient labeling to measure the structure but not so much as to influence the results. The optimization of hydroxyl radical dose is typically performed using an indirect Alexa488 fluorescence assay sensitive to hydroxyl radical concentration, but full evaluation of the experiment's outcome relies upon bottom-up liquid chromatography mass spectrometry (LC-MS) measurements to directly determine sites and extent of oxidative labeling at the peptide and protein level. A direct evaluation of the extent of labeling to provide direct and absolute measurements of dose and “safe” dose ranges in terms of, for example, average numbers of labels per protein, would provide immediate feedback on experimental outcomes prior to embarking on detailed LC-MS analyses. To this end, we describe an approach to integrate intact MS screening of labeled samples immediately following exposure, along with metrics to quantify the extent of observed labeling from the intact mass spectra. Intact MS results on the model protein lysozyme were evaluated in the context of Alexa488 assay results and a bottom-up LC-MS analysis of the same samples. In conclusion, this approach provides a basis for placing delivered hydroxyl radical dose metrics on firmer technical grounds for synchrotron X-ray footprinting of proteins, with explicit parameters to increase the likelihood of a productive experimental outcome. Further, the method directs approaches to provide absolute and direct dosimetry for all types of labeling for protein footprinting.

59 BASIC BIOLOGICAL SCIENCES↗

Results from the Gas Chromatograph Mass Spectrometer (GCMS) Experiment on the Cassini-Huygens Probe

The Gas Chromatograph Mass Spectrometer was one of six instruments on the Cassini-Huygens Probe mission to Titan. The GCMS measured in situ the chemical composition of the atmosphere during the probe descent and served as the detector for the pyrolization products for the Aerosol Collector Pyrolyser (ACP) experiment to determine the composition of the aerosol particles. The GCMS collected data from an altitude of 146 km to ground impact. The Probe and the GCMS survived impact and collected data for 1 hour and 9 minutes on the surface. Mass spectra were collected during descent and on the ground over a range of m/z from 2 to 141. The major constituents of the lower atmosphere were confirmed to be N2 and CH4. The methane mole fraction was uniform in the stratosphere. It increased below the tropopause, at about 32 km altitude, monotonically toward the surface, reaching a plateau at about 8 km at a level near saturation. After surface impact a steep increase of the methane signal was observed, suggesting evaporation of surface condensed methane due to heating by the GCMS sample inlet heater. The measured mole fraction of Ar-40 is 4.3x10(exp -5) and of Ar-36 is 2.8x10(exp -7). The other primordial noble gases were below 10(exp -8) mole fraction. The isotope ratios of C-12/C-13 determined from methane measurements are 82.3 and of N-14/N-15 determined from molecular nitrogen are 183. The D/H isotope ratio determined from the H2 and HD measurements is 2.3x10(exp -4). Carbon dioxide, methane, acetylene and cyanogen were detected evaporating from the surface in addition to methane. The GCMS employed a quadrupole mass filter with a secondary electron multiplier detection system and a gas sampling system providing continuous direct atmospheric composition measurements and batch sampling through three gas chromatographic (GC) columns, a chemical scrubber and a hydrocarbon enrichment cell. The GCMS gas inlet was heated to prevent condensation, and to evaporate volatiles from the surface after impact.

Niemann, H.↗

Results from the Gas Chromatograph Mass Spectrometer (GCMS) Experiment on the Cassini-Huygens Probe

The Gas Chromatograph Mass Spectrometer was one of six instruments on the Cassini-Huygens Probe mission to Titan. The GCMS measured in situ the chemical composition of the atmosphere during the probe descent and served as the detector for the pyrolization products for the Aerosol Collector Pyrolyser (ACP) experiment to determine the composition of the aerosol particles. The GCMS collected data from an altitude of 146 km to ground impact. The Probe and the GCMS survived impact and collected data for 1 hour and 9 minutes on the surface. Mass spectra were collected during descent and on the ground over a range of mlz from 2 to 141. The major constituents of the lower atmosphere were confirmed to be N2 and CH4. The methane mole fraction was uniform in the stratosphere. It increased below the tropopause, at about 32 km altitude, monotonically toward the surface, reaching a plateau at about 8 km at a level near saturation. After surface impact a steep increase of the methane signal was observed, suggesting evaporation of surface condensed methane due to heating by the GCMS sample inlet heater. The measured mole fraction of Ar-40 is 4.3x10(exp -5) and of Ar-36 is 2.8x10(exp -7). The other primordial noble gases were below 10(exp -8) mole fraction. The isotope ratios of C-12/C-13 determined from methane measurements are 82.3 and of N-14/N-15 determined from molecular nitrogen are 183. The D/H isotope ratio determined from the H2 and HD measurements is 2.3x10(exp -4). Carbon dioxide, ethane, acetylene and cyanogen were detected evaporating from the surface in addition to methane. The GCMS employed a quadrupole mass filter with a secondary electron multiplier detection system and a gas sampling system providing continuous direct atmospheric composition measurements and batch sampling through three gas chromatographic (GC) columns, a chemical scrubber and a hydrocarbon enrichment cell. The GCMS gas inlet was heated to prevent condensation, and to evaporate volatiles from the surface after impact.

Niemann, Hasso↗