Search NASA⌕ Search

SEARCH · Search NASA

Results for “mass spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

U-Pu and Ba-Cs isotopic measurements on Trinitite by laser ablation sampling on the Neoma MC-ICP-MS

In this study we present the results of combined U-Pu and Ba-Cs isotope measurements obtained by laser ablation (LA) sampling of two glassy debris fragments (‘Trinitite’) from the world's first atomic bomb detonation conducted in New Mexico on July 16, 1945. Our primary goal in conducting these measurements was to understand whether examination of the U-Pu and Ba-Cs systematics by direct sampling (e.g. without any chemical separation or purification prior to isotope ratio measurement) could yield meaningful information that would differentiate the Trinitite fragments from glassy material lacking a nuclear fission signature. These measurements were conducted on a ThermoFisher Scientific Neoma multi collector – inductively coupled plasma – mass spectrometer (MC-ICP-MS), which is a relatively new MC-ICP-MS platform, so we also examine the behavior of these isotope systems in standards sampled in solution and via LA. Unsurprisingly, the measurements made on purified solutions of the U, Pu, and Ba isotopic standards produce high precision isotope ratios. Furthermore, this extends to the U-Pu measurements made by LA sampling, with the expected degradation in precision and accuracy related to matrix effects and signal intensity fluctuation. However, the Ba-Cs data acquired by LA is of low precision across all of the matrices examined and bears evidence of complex mass fractionation that will require further investigation to resolve. In total, our results indicate that the observed U-Pu isotope data are of sufficient quality to accurately constrain the U and Pu isotopic composition of glass containing sub-ppm levels of these elements which in turn could be used to differentiate glass containing anthropogenic fission products from natural glass whereas the Ba-Cs LA data cannot be used for this purpose until further methodological refinement is performed.

Ba-Cs↗

Analysis of solid uranium particulates on cotton swipes with an automated microextraction-ICP-MS system

Here, an automated microextraction method coupled to an inductively coupled plasma – mass spectrometer (ICP-MS) was developed for the direct analysis of solid uranium particulates on the surface of cotton swipes. The microextraction probe extracts particulates from the sample surface, in a flowing solvent, and directs the removed analyte to an ICP-MS for isotopic determination. The automated system utilizes a mechanical XY stage that is software controlled with the capability of saving and returning to specific locations and a camera focused to the swipe surface for optimal viewing of the extracted locations (i.e., material present). Here, particulates (n = 135) were extracted and measured by ICP-MS, including 35 depleted uranyl nitrate hexahydrate (UN) (used for mass bias corrections), 50 uranyl fluoride (UO 2 F 2 ), and 50 uranyl acetate (UAc) particulates. Blank extractions were performed on the cotton swipes between triplicate sample analyses. Between each swipe extraction, the probe was sent between two wells containing 10% and 5% HNO 3 to clean the probe head and to eliminate any analyte carryover between particulates. The measured 235 U/ 238 U and 234 U/ 238 U isotope ratios for the UO 2 F 2 particulates were 0.00725(8) and 0.000054(4), a percent relative difference (% RD) of –0.041% and –1.7% from the reference isotope ratios determined in-lab through multi-collector ICP-MS analysis of dissolved aliquots of the U material. The UAc samples had a measured 235 U/ 238 U isotope ratio of 0.00206(7), a –0.96% relative difference from the reference value of 0.00208(1). The 234 U/ 238 U and 236 U/ 238 U isotope ratios were 0.000008(1) and 0.000031(4), –5.1% RD and –4.3% RD, respectively. The automated sample stage enabled seamless and rapid particle analysis, leading to a significant increase in throughput versus what was previously possible. Additionally, the saved location capability reduced user sampling error as sampling locations were easily stored and recalled. Analysis of U particles on the swipe surface – including blanks, mass bias, and triplicate extractions – was completed in less than an hour without any sample preparation necessary.

47 OTHER INSTRUMENTATION↗

Molecular beam scattering of neon from flat jets of cold salty water

Molecular beam scattering experiments are carried out to study collisions between Ne atoms (E i = 24.3 kJ mol-1) and the surface of a cold salty water (8 m LiBr(aq), 230 K) flat jet. Translational energy distributions are collected as a function of scattering angle using a rotatable mass spectrometer. Impulsive scattering and thermal desorption contribute to the overall scattering distributions, but impulsive scattering dominates at all three incidence angles explored. Highly super-specular scattering is observed in the impulsive scattering channel that is attributed to anisotropic momentum transfer to the liquid surface. The thermal desorption channel exhibits a cos θ angular distribution. Compared to Ne scattering from dodecane, fractional energy loss in the impulsive scattering channel is much larger across a wide range of deflection angles. A soft-sphere model is applied to investigate the kinematics of energy transfer between the scatterer and liquid surface. Fitting to this model yields an effective surface mass of 250-60 +100 amu and internal excitation of 11.8 ± 1.6 kJ mol-1, both of which are considerably larger than for Ne/dodecane. It thus appears that energy transfer to cold salty water is more efficient than to a dodecane liquid surface, a result attributed to the extensive hydrogen-bonded network of liquid water and roughness of the liquid surface.

Yang, Walt↗

Analysis of useful ion yield for Si in GaN by secondary ion mass spectrometry

The optimum detection levels that can be achieved by a secondary ion mass spectrometer are dependent on how efficiently a particular species of interest can be ionized and detected. One can determine in advance whether the analysis of a particular ion in the sample is possible, if the useful ion yield is known. The useful ion yield depends on the element, instrument transmission, the analytical conditions, the sample matrix, etc. The value of the useful ion yield for a species can diverge from one instrument type to another due to its different transmission and ionization probabilities. However, the same tendencies in the results may be expected for all types of instruments. In this paper, the authors present a quantitative secondary ion mass spectrometry analysis of the useful ion yield for the silicon dopant species in a gallium nitride matrix grown by metal organic chemical vapor deposition. Positively ionized cesium was used as the primary ion beam, and its energy was varied in the range from 0.5 to 5 kV. A quadrupole mass analyzer was utilized to collect secondary ion species of interest. The analysis results can be used to determine the primary beam energies for optimal Si sensitivity.

Senevirathna, M. K. Indika (ORCID:0000000243575029↗

Elemental profiling and genomewide association studies reveal genomic variants modulating ionomic composition in Populus trichocarpa leaves

Samples were collected from a population of 1,089 black cottonwood genotypes (P. trichocarpa) assembled from native stands to encompass the central portion of the natural range of the species, stretching from 38.8° to 54.3° N Q13 latitude from California, USA, to British Columbia, Canada. Establishment of the common garden, growth conditions, and site maintenance have been described by Muchero et al (2015). In this study, leaf samples for ionomic profiling were collected from 4-year-old trees, during the growing season, in July 2012, from a field located in Clatskanie, Oregon, USA (46°6′11″N 123°12′13″W). The field site was located in a protected alluvial floodplain containing a uniform Wauna-Locoda silt loam soil area characterized by an acidic pH, in Columbia County, Oregon. A subset of 584 out of the 1,089 P. trichocarpa genotypes were represented in this sampling. These genotypes were randomly selected to represent the geographical distribution of the population. A single fully mature (LPI 7-9) leaf on the south side of the tree exposed to full sunlight conditions was removed from the tree within a 6-hour window centering on solar noon and immediately frozen under dry ice before processing. Leaf samples of 584 P. trichocarpa genotypes were finely ground to 40 mm particle size using a mortar and pestle, and ionomic composition was analyzed using ICP-MS. In total, 20 elements were profiled, including aluminum (Al27), arsenic (As75), boron (B11), cadmium (Cd111), calcium (Ca43), cobalt (Co), copper (Cu), iron (Fe57), magnesium (Mg25), manganese (Mn55), molybdenum (Mo), nickel (Ni60), phosphorus (P31), potassium (K39), rubidium (Rb85), selenium (Se82), sodium (Na23), strontium (Sr88), sulfur (S34), and zinc (Zn66), following a protocol established by Ziegler et al. (2013). For each sample, 75mg of powder was digested overnight in 2.5 mL HNO3 containing 20 parts per billion (ppb) indium as an internal standard, following the protocol described in Ziegler et al. (2013). Following a dilution, concentration of the 20 elements was measured using an Elan 6000 DRC-e mass spectrometer (Perkin-Elmer SCIEX) connected to a PFA microflow nebulizer (Elemental Scientific) and Apex HF desolvator (Elemental Scientific). One measurement per sample per genotype was done. For subsequent analyses, the quantifications were converted to total element concentration.

CBI ionomics, GWAS, plasma-mass spectrometry, neut↗

Measurement report: Extreme heat and wildfire emissions enhance volatile organic compounds in a temperate forest

Climate extremes are projected to cause unprecedented deviations in the emission and transformation of volatile organic compounds (VOCs), which trigger feedback mechanisms that will impact the atmospheric oxidation and formation of aerosols and clouds. However, the response of VOCs to future conditions such as extreme heat and wildfire events is still uncertain. This study explored the modification of the mixing ratio and distribution of several anthropogenic and biogenic VOCs in a temperate oak–hickory–juniper forest as a response to increased temperature and transported biomass burning plumes. A chemical ionization mass spectrometer was deployed on a tower at a height of 32 m in rural central Missouri, United States, for the continuous and in situ measurement of VOCs from June to August of 2023. The maximum observed temperature in the region was 38 °C, and during multiple episodes the temperature remained above 32 °C for several hours. Biogenic VOCs such as isoprene and monoterpene followed closely the temperature daily profile but at varying rates, whereas anthropogenic VOCs were insensitive to elevated temperature. During the measurement period, wildfire emissions were transported to the site and substantially increased the mixing ratios of acetonitrile and benzene, which are produced from burning of biomass. An in-depth analysis of the mass spectra revealed more than 250 minor compounds, such as formamide and methylglyoxal. Extreme heat and presence of wildfire plumes modified the overall volatility, reactivity, O : C, and H : C ratios of the extended list of VOCs. The calculated OH reactivities during extreme temperature condition and transport of biomass burning plumes were 106.37±4.27 and 106.22±5.15 s −1 , respectively, which are substantially higher than background level of 98.78±1.16 s −1 . Multivariate analysis also clustered the compounds into five factors, which highlighted the sources of the unaccounted-for VOCs. Ultimately, results here underscore the effect of extreme heat and wildfire emissions on the overall chemical properties VOC in a temperate forest.

Salvador, Christian Mark [Oak Ridge National Labor↗

Human Host Cellular Response to HCoV-229E Infection Proteomics (ACS-JM-DP2)

The purpose of this experiment was to evaluate the human host cellular response to wild-type Human coronavirus strain 229E (HCoV-229E) infection. Sample data was obtained for mock and infected immortalized human lung epithelial cells (A549) (MOI 5) nuclear extracts, immortalized human lung fibroblasts cells (MRC5) (MOI5) nuclear extracts, and primary human airway epithelial (HAE) (MOI 3) cells from lung tissue and processed for proteome analysis. Processed datasets are openly accessible from the download button and contain secondary processed proteomic results files and supporting metadata materials. Experimental proteomics samples were prepared using Limited Proteolysis (LiP) methods for Label-free quantification (LFQ) and global proteomic evaluation. Sample data was acquired using a Q-Exactive HF-X mass spectrometer and was processed and compiled using MaxQuant software (v.1.6.17.0). Processed proteomic data downloads include a sample naming key, processed MaxQuant results/parameters, and protein annotated relative abundance files. See corresponding primary data accessions below and Viral Experiment LiP Analysis source code supporting data transparency and reuse. Experimental transcriptomics samples were collected in parallel and processed for RNA sequencing (RNA-Seq) as summarized under ACS-DP1 (https://data.pnnl.gov/group/nodes/dataset/34069).

59 BASIC BIOLOGICAL SCIENCES↗

Evaluating the performance of a high resolution SLIM IM module integrated with an Agilent 6560 IM-QTOF MS - CRADA 413 (Final Report)

Developing new technologies that enhance our abilities to identify molecular signatures is important for the health of the public, the environment, and national security. Deploying these novel technologies requires multiple stages of validation and evaluation. This project focused on evaluating a technology developed at PNNL named Structures for Lossless Ion Manipulations (SLIM) in the context of a commercially available ion mobility mass spectrometer instrument from Agilent Technologies. There is a benefit to integrating the recently developed SLIM module into a real-world instrument platform. Data from the combined instrument will provide new standards for characterizing samples using ion mobility. These standards, related to both the drift time of ions and their resulting collisional cross sections (CCS) will be of value in characterizing samples from both humans and environmental samples, such as soil microbiomes. Because no previous instrument has been designed and implemented to simultaneously analyze the same sample in both constant and oscillating drift fields, the project will provide a new research capability that will support research in a wide variety of applications. The evaluation approach included measuring the resolving power, mass range, sensitivity, and accuracy of two SLIM variations (constant and oscillating fields). Although SLIM performed similarly to the commercial instrument in terms of sensitivity, mass range, and accuracy the resolving power of SLIM far exceeded that of the commercially-available instrument. This validation will provide critically useful data to our commercial partners which they can use to reach informed decisions on the advantages of the SLIM technology such as the outstanding performance and the low cost of manufacturing.

42 ENGINEERING↗

Organic Acid Aerosol Measurements from the Mount Airy Site for CoURAGE

This study investigates the prevalence and distribution of organic acid aerosols in a rural environment using filter-based measurements collected in Mount Airy, Maryland, during the CoURAGE campaign from March 19th through June 12th 2025. PM2.5 filters quantify a range of organic acids commonly associated with secondary organic aerosol formation and atmospheric oxidation processes. Each filter was collected using a 15 LPM sampler and was extracted in ultrapure Millipore water (>18 MΩ), allowing water-soluble organic acids to be extracted into solution for analysis. The extracts were then examined using a Waters Acquity I-Class PLUS liquid chromatography system coupled to a Bruker Maxis-II ultra-high-resolution Q-TOF mass spectrometer with electrospray ionization, providing high-sensitivity detection and separation of target compounds. Concentrations of several key organic acids were quantified, including acetic, propionic, pyruvic, butyric, oxalic, isovaleric, valeric, malonic, maleic, succinic, glutaric, malic, adipic, and citric acids. These findings contribute to ongoing efforts to understand regional aerosol composition and their impacts on aerosol-cloud interactions.

Acetic acid↗

Agilent CRADA (Abstract)

The CRADA between Agilent Technologies Inc. and Battelle will focus on five software components as listed below: Prototype 4D Feature Finding functionality with a particular focus on recovering low level features and extending the bottom end dynamic range of IM-MS technology. Compare and contrast developments to current 4D Feature Finding capabilities. Highlight important algorithmic aspects employed. Implement the PNNL saturation correction algorithm. Agilent will give PNNL the needed data file access API and assistance in understanding it implementation and any needed instrumental aspects. Supported high resolution products to include Agilent’s TOF, QTOF and IM-QTOF mass spectrometers. PNNL will then work with Agilent to benchmark performance. Implementation of the PNNL Hadamard de-multiplexing algorithm. Agilent will give provide PNNL the needed date file access API access and as needed assistance in understanding the current Agilent multiplexed IM offering. PNNL will then work with Agilent on benchmark performance. Add ion mobility collision cross sections to existing and new metabolomic libraries for data analysis with Agilent’s informatics program MPP/ID Browser. PNNL will work with Agilent to create a software pipeline that takes data from chemical and metabolic standards and properly formats it for inclusion in MPP accessible libraries, using the collision cross section as a new separation dimension. Improvements of MPP multidimensional matching to identify metabolomic features using multiple characteristics beyond retention time and accurate mass. Most significantly matching will include analyte collision cross section with proposed support for sample fraction or RapidFire cartridge and fragmentation spectra. PNNL will work with Agilent to modify and improve the current MPP analysis pipeline to allow for creating, aligning, and identifying MS features defined by accurate mass, collision cross section and chromatographic retention time. As additional criteria such as fraction or RapidFire cartridge type are supported in the identification process, then they also will become part of the automation workflow. This includes the automation of said system to work with command line program (i.e. not a GUI) sufficient for programmatic execution in a pipeline.

97 MATHEMATICS AND COMPUTING↗

Enhancing characterization of organic nitrogen components in aerosols and droplets using high-resolution aerosol mass spectrometry

This study aims to enhance the understanding and application of the Aerodyne high-resolution aerosol mass spectrometer (HR-AMS) for comprehensive characterization of organic nitrogen (ON) compounds in aerosol particles and atmospheric droplets. To achieve this, we analyzed seventy-five N-containing organic compounds, representing a diverse range of ambient ON types, including amines, amides, amino acids, N-heterocycles, protein, and humic acids. Our results show that ON compounds can produce significant levels of NH x + and NO x + ion fragments, which are typically recognized as ions representative of inorganic nitrogen species. We also discovered the presence of CH 2 N + at m/z = 28.0187, an ion fragment that is rarely quantified in ambient datasets due to substantial interference from air-related N 2 + . As a result, we determined that an updated calibration factor of 0.79 is necessary to accurately quantify ON content using aerosol mass spectrometry. We also assessed the relative ionization efficiencies (RIEs) for different ON species and found that the average RIE of ON compounds (1.52 ± 0.58) aligns with the commonly used default value of 1.40 for organic aerosol (OA). Moreover, through a careful examination of the HR-AMS mass spectral features of various ON types, we propose fingerprint ion series that can aid the ON speciation analysis. The presence of C n H 2n+2 N + ions is closely linked with amines, with CH 4 N + indicating primary amines, C 2 H 6 N + suggesting secondary amines, and C 3 H 8 N + representing tertiary amines. C n H 2n NO + ions (especially for n values of 1–4) are very likely derived from amides. The co-existence of three ions, C 2 H 4 NO 2 + , C 2 H 3 NO + , and CH 4 NO + , serves as an indicator for the presence of amino acids. Additionally, the presence of C x H y N 2 + ions indicates the occurrence of 2N-heterocyclic compounds. Notably, an elevated abundance of NH 4 + is a distinct signature for amines and amino acids, as inorganic ammonium salts produce only negligible amounts of NH 4 + in HR-AMS. Finally, we quantified the ON contents in submicron particles (PM 1 ) and fog waters in Fresno, California and PM 1 in New York City (NYC). Our results revealed the substantial presence of amino compounds in both Fresno and NYC aerosols, whereas concurrently collected fog waters contained a broader range of ON species, including N-containing aromatic heterocycle (e.g., imidazoles) and amides. These findings highlight the significant potential of employing the widespread HR-AMS measurements of ambient aerosols and droplets to enhance our understanding of the sources, transformation processes, and environmental impacts associated with ON compounds in the atmosphere.

54 ENVIRONMENTAL SCIENCES↗

Hollow fiber mid-ID spectrometer with UV laser ablation sampling for fine spatial reoslution of isotope ratios in solids

We describe a system that combines isotope ratio analysis via mid-infrared (Mid-IR) laser absorption spectroscopy with fine spatial resolution sampling using a UV pulsed laser. The UV laser ablates a pit in a solid on the order of 10 microns in diameter. The sample-derived particulates resulting from laser ablation pass through a micro-combustor, and the resulting gas is analyzed using Mid-IR laser absorption spectroscopy in a capillary absorption spectrometer (CAS). The CAS uses a hollow fiber optic waveguide with a reflective inner coating and a small internal volume on the order of 1ml. The hollow fiber both guides the laser light from source to detector and contains the gas sample at reduced pressure. Near unity overlap between the laser beam and sample enables sensitive analysis with ultra-small sample size. A prototype system has been demonstrated to enable stable carbon isotopic analysis (d13C) with 1 per mil precision using <1 picomole of carbon and is currently being used to study nutrient exchange in soil/root/microbial rhizosphere studies. The smaller sample size of this system is enabling fine spatial resolution analysis (on the order of 10 microns), which is roughly an order of magnitude smaller than was possible with an isotope ratio mass spectrometer (IRMS). In addition to rhizosphere studies, the system can provide a useful tool for fine scale isotope analysis with applications in biological, forensic, and environmental science.

capillary absorption spectroscopy, laser ablation,↗

Mapping the N = 40 island of inversion: Precision mass measurements of neutron-rich Fe isotopes

Nuclear properties across the chart of nuclides are key to improving and validating our understanding of the strong interaction in nuclear physics. Here we present high-precision mass measurements of neutron-rich Fe isotopes performed at the TITAN facility. The multiple-reflection time-of-flight mass spectrometer (MR-ToF-MS), achieving a resolving power greater than 600000 for the first time, enabled the measurement of 63–70 Fe, including first-time high-precision direct measurements (δm/m ≈ 10 -7 ) of 68–70 Fe, as well as the discovery of a long-lived isomeric state in 69 Fe. These measurements are accompanied by both mean-field and ab initio calculations using the most recent realizations which enable theoretical assignment of the spin-parities of the 69 Fe ground and isomeric states. Together with mean-field calculations of quadrupole deformation parameters for the Fe isotope chain, these results benchmark a maximum of deformation in the N = 40 island of inversion in Fe and shed light on trends in level densities indicated in the newly refined mass surface.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantification of Key Peroxy and Hydroperoxide Intermediates in the Low-Temperature Oxidation of Dimethyl Ether

Dimethyl ether (DME) oxidation is a model chemical system with a small number of prototypical reaction intermediates that also has practical importance for low-carbon transportation. Although it has been studied experimentally and theoretically, ambiguity remains in the relative importance of competing DME oxidation pathways in the low-temperature autoignition regime. To focus on the primary reactions in DME autoignition, we measured the time-resolved concentration of five intermediates, CH 3 OCH 2 OO (ROO), OOCH 2 OCH 2 OOH (OOQOOH), HOOCH 2 OCHO (hydroperoxymethyl formate, HPMF), CH 2 O, and CH 3 OCHO (methyl formate, MF), from photolytically initiated experiments. We performed these studies at P = 10 bar and T = 450-575 K, using a high-pressure photolysis reactor coupled to a time-of-flight mass spectrometer with tunable vacuum-ultraviolet synchrotron ionization at the Advanced Light Source. Our measurements reveal that the timescale of ROO decay and product formation is much shorter than predicted by current DME combustion models. The models also strongly underpredict the observed yields of CH 2 O and MF and do not capture the temperature dependence of OOQOOH and HPMF yields. Adding the ROO + OH $\rightarrow$ RO + HO 2 reaction to the chemical mechanism (with a rate coefficient approximated from similar reactions) improves the prediction of MF. Increasing the rate coefficients of ROO ↔ QOOH and QOOH + O 2 ↔ OOQOOH reactions brings the model predictions closer to experimental observations for OOQOOH and HPMF, while increasing the rate coefficient for the QOOH $\rightarrow$ 2 CH 2 O + OH reaction is needed to improve the predictions of formaldehyde. In conclusion, to aid future quantification of DME oxidation intermediates by photoionization mass spectrometry, we report experimentally determined ionization cross-sections for ROO, OOQOOH, and HPMF.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancing characterization of organic nitrogen components in aerosols and droplets using high-resolution aerosol mass spectrometry

Abstract. This study aims to enhance the understanding and application of the Aerodyne high-resolution aerosol mass spectrometer (HR-AMS) for the comprehensive characterization of organic nitrogen (ON) compounds in aerosol particles and atmospheric droplets. To achieve this goal, we analyzed 75 N-containing organic compounds, representing a diverse range of ambient non-organonitrate ON (NOON) types, including amines, amides, amino acids, N heterocycles, protein, and humic acids. Our results show that NOON compounds can produce significant levels of NHx+ and NOx+ ion fragments, which are typically recognized as ions representative of inorganic nitrogen species. We also identified the presence of CH2N+ at m/z = 28.0187, an ion fragment rarely quantified in ambient datasets due to substantial interference from N2+. As a result, the utilization of an updated calibration factor of 0.79 is necessary for accurate NOON quantification via the HR-AMS. We also assessed the relative ionization efficiencies (RIEs) for various NOON species and found that the average RIE for NOON compounds (1.52 ± 0.58) aligns with the commonly used default value of 1.40 for organic aerosol. Moreover, through a careful examination of the HR-AMS mass spectral features of various NOON types, we propose fingerprint ion series that can aid the NOON speciation analysis. For instance, the presence of CnH2n+2N+ ions is closely linked with amines, with CH4N+ indicating primary amines, C2H6N+ suggesting secondary amines, and C3H8N+ representing tertiary amines. CnH2nNO+ ions (especially for n values of 1–4) are very likely derived from amides. The co-existence of three ions, C2H4NO2+, C2H3NO+, and CH4NO+, serves as an indicator for the presence of amino acids. Additionally, the presence of CxHyN2+ ions indicates the occurrence of 2N-heterocyclic compounds. Notably, an elevated abundance of NH4+ is a distinct signature for amines and amino acids, as inorganic ammonium salts produce only negligible amounts of NH4+ in the HR-AMS. Finally, we quantified the NOON contents in submicron particles (PM1) and fog water in Fresno, California, and PM1 in New York City (NYC). Our results revealed the substantial presence of amino compounds in both Fresno and NYC aerosols, whereas concurrently collected fog water in Fresno contained a broader range of NOON species, including N-containing aromatic heterocycle (e.g., imidazoles) and amides. These findings highlight the significant potential of employing the widespread HR-AMS measurements of ambient aerosols and droplets to enhance our understanding of the sources, transformation processes, and environmental impacts associated with NOON compounds in the atmosphere.

Ge, Xinlei (ORCID:0000000195316478)↗

Design of an Online Electrochemical Mass Spectrometry System to Study Gas Evolution from Cells with Lean and Volatile Electrolytes

Gas evolution in high-energy Li-ion batteries remains a pervasive problem for a multitude of chemistries, jeopardizing the electrochemical performance and safety for consumers of electric vehicles. Many electrode–electrolyte degradation processes evolve gasses that may be detected in-situ with online electrochemical mass spectrometry (OEMS). In this work, details are provided for the setup and validation of an OEMS system that operates well under lean and volatile electrolyte conditions. Quite notably, the OEMS cells with only 40 µL of electrolyte and intermittent headspace sampling exhibit comparable electrochemical performance to flooded coin-cells. It is demonstrated that the onset time, shape, and magnitude of the gas evolution profiles calculated from mass spectrometer measurements match well to a known pressure reference through the use of an empirically determined fraction of removal. The off-gassing characteristics from a set of layered-oxide materials, NMC532, NMC811, and LNO, are used to further validate the OEMS setup against the literature. It is shown that many of the features present in the OEMS curves for equivalent systems from other groups are captured by this OEMS system. Finally, at an upper cut-off voltage of 4.4 V, LNO exhibits an intense release of CO 2 , O 2 , and CO gas relative to NMC532 and NMC811.

25 ENERGY STORAGE↗

Chemical identification of new particle formation and growth precursors through positive matrix factorization of ambient ion measurements

Abstract. In the lower troposphere, rapid collisions between ions and trace gases result in the transfer of positive charge to the highest proton affinity species and negative charge to the lowest proton affinity species. Measurements of the chemical composition of ambient ions thus provide direct insight into the most acidic and basic trace gases and their ion–molecule clusters – compounds thought to be important for new particle formation and growth. We deployed an atmospheric pressure interface time-of-flight mass spectrometer (APi-ToF) to measure ambient ion chemical composition during the 2016 Holistic Interactions of Shallow Clouds, Aerosols, and Land Ecosystems (HI-SCALE) campaign at the United States Department of Energy Atmospheric Radiation Measurement facility in the Southern Great Plains (SGP), an agricultural region. Cations and anions were measured for alternating periods of ∼ 24 h over 1 month. We use binned positive matrix factorization (binPMF) and generalized Kendrick analysis (GKA) to obtain information about the chemical formulas and temporal variation in ionic composition without the need for averaging over a long timescale or a priori high-resolution peak fitting. Negative ions consist of strong acids including sulfuric and nitric acid, organosulfates, and clusters of NO3- with highly oxygenated organic molecules (HOMs) derived from monoterpene (MT) and sesquiterpene (SQT) oxidation. Organonitrates derived from SQTs account for most of the HOM signal. Combined with the diel profiles and back trajectory analysis, these results suggest that NO3 radical chemistry is active at this site. SQT oxidation products likely contribute to particle growth at the SGP site. The positive ions consist of bases including alkyl pyridines and amines and a series of high-mass species. Nearly all the positive ions contained only one nitrogen atom and in general support ammonia and amines as being the dominant bases that could participate in new particle formation. Overall, this work demonstrates how APi-ToF measurements combined with binPMF analysis can provide insight into the temporal evolution of compounds important for new particle formation and growth.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Observation of Slow Eigen-Zundel Interconversion in H + (H 2 O) 6 Clusters upon Isomer-Selective Vibrational Excitation and Buffer Gas Cooling in a Cryogenic Ion Trap

The formation of isomers when trapping floppy cluster ions in a temperature-controlled ion trap is a generally observed phenomenon. This involves collisional quenching of the ions initially formed at high temperature by buffer gas cooling until their internal energies fall below the barriers in the potential energy surface that separate them. Here we explore the kinetics at play in the case of the two isomers adopted by the H + (H 2 O) 6 cluster ion that differ in the proton accommodation motif. One of these is most like the Eigen cation with a tricoordinated hydronium motif (denoted E), and the other is most like the Zundel ion with the proton equally shared between two water molecules (denoted Z). After initial cooling to about 20 K in the radiofrequency (Paul) trap, the relative populations of these two spectroscopically distinct isomers are abruptly changed through isomer-selective photoexcitation of bands in the OH stretching region with a pulsed (~6 ns) infrared laser while the ions are in the trap. We then monitor the relaxation of the vibrationally excited clusters and reformation of the two cold isomers by recording infrared photodissociation spectra with a second IR laser as a function of delay time from the initial excitation. The latter spectra are obtained after ejecting the trapped ions into a time-of-flight photofragmentation mass spectrometer, thus enabling long (~0.1 s) delay times. Excitation of the Z isomer is observed to display long-lived vibrationally excited states that are collisionally cooled on a ms time scale, some of which quench into the E isomer. These excited E species then display spontaneous interconversion to the Z form on a ~10 ms time scale. Furthermore, these qualitative observations set the stage for a series of experimental measurements that can provide quantitative benchmarks for theoretical simulations of cluster dynamics and the potential energy surfaces that underlie them.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗