Search NASA⌕ Search

SEARCH · Search NASA

Results for “material sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Volatile organic compound sensing based on coral rock-like ZnO

Highlights: • A coral rock-like ZnO with porous structure was successfully synthesized. • Coral rock-like ZnO realized the large gas response towards VOCs. • The porous structure may play an essential role in the surface sensing reaction. - Abstract: This work presented highly sensitive coral rock-like ZnO to investigate the sensing performances for volatile organic compounds (VOCs), including formaldehyde, methylbenzene, methanol and acetone. The coral rock-like ZnO with porous structure was synthesized using a solvothermal process and subsequent calcination. The gas response of the sensor based on the coral rock-like ZnO was reported for the four types of VOC vapors at different operating temperatures and gas concentrations. It was found that the fabricated sensor was sensitive to the four gases, revealing large gas response as well as fast response and recovery speed, which was ascribed to its distinctive porous nanostructure, resulting in adequate surface sensing reaction and effective gas diffusion.

36 MATERIALS SCIENCE↗

Narrow-band radiation sensing in the terahertz and microwave bands using the radiation-induced magnetoresistance oscillations

Tuned narrow-band sensing of microwave and terahertz radiation can be realized by subjecting an irradiated two-dimensional electron system to both a static and a time varying magnetic field, and detecting at the harmonics of the modulation. A third harmonic sensor is considered here in conjunction with periodic-in-the-inverse-magnetic-field radiation-induced magnetoresistance oscillations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Medipix2/USB Portable Radiation Camera

Advances in the field of semiconductor technologies in the last years make possible to develop new types of ionizing radiation detectors. The Medipix2 readout ASIC is an example of such a device. It is the hybrid single photon counting imaging chip (sensor and readout chips are fabricated separately). With an appropriate sensor chip on the top, it can count single X-ray photons, without any noise or dark current, at high fluxes (several Gigaphotons per cm{sup 2} per second). It also offers excellent radiation hardness and good position resolution (256x256 pixels, each pixel has a 55x55 {mu}m{sup 2} area). To make the Medipix2 imaging chip more portable for specific applications a microprocessor controlled read-out system based on the USB (Universal Serial Bus) interface has been developed. It integrates all necessary detector support into one compact device (75x46 mm{sup 2}). All power supplies including sensor bias (up to 100 V) are internally derived from the voltage provided by the USB connection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CMOS Integrated Carbon Nanotube Sensor

Recently carbon nanotubes (CNTs) have been gaining their importance as sensors for gases, temperature and chemicals. Advances in fabrication processes simplify the formation of CNT sensor on silicon substrate. We have integrated single wall carbon nanotubes (SWCNTs) with complementary metal oxide semiconductor process (CMOS) to produce a chip sensor system. The sensor prototype was designed and fabricated using a 0.30 um CMOS process. The main advantage is that the device has a voltage amplifier so the electrical measure can be taken and amplified inside the sensor. When the conductance of the SWCNTs varies in response to media changes, this is observed as a variation in the output tension accordingly.

36 MATERIALS SCIENCE↗

Ultrasonic High-Temperature Sensors: Past Experiments and Prospects for Future Use

Ultrasonic thermometry sensors (UTS) have been intensively studied in the past to measure temperatures from 2080 to 3380 K. This sensor, which uses the temperature dependence of acoustic velocity in materials, was developed for experiments in extreme environments. Its major advantages, which are (a) recording capability of a temperature profile deduced from the notches on the sensor rod and (b) measurement near the sensor material melting point, can be of great interest when dealing with on-line monitoring of high temperature safety tests. Ultrasonic techniques were successfully applied in several severe accident related experiments. If new developments are conducted with other materials, this sensor type may be used in a wide-range of experimental areas where robustness and compactness are required. Long-term irradiation experiments of nuclear fuel to extremely high burn-ups could benefit from this previous experience. After an overview of UTS technology, this paper summarizes experimental work performed to improve the reliability of these sensors. The various designs, advantages and drawbacks are outlined and future prospects for long term high temperature irradiation experiments are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

UV-activated ZnO films on a flexible substrate for room temperature O 2 and H 2 O sensing

Here, we demonstrate that UV-light activation of polycrystalline ZnO films on flexible polyimide (Kapton) substrates can be used to detect and differentiate between environmental changes in oxygen and water vapor. The in-plane resistive and impedance properties of ZnO films, fabricated from bacteria-derived ZnS nanoparticles, exhibit unique resistive and capacitive responses to changes in O 2 and H 2 O. We also propose that the distinctive responses to O 2 and H 2 O adsorption on ZnO could be utilized to statistically discriminate between the two analytes. Molecular dynamic simulations (MD) of O 2 and H 2 O adsorption energy on ZnO surfaces were performed using the large-scale Atomic/Molecular Massively Parallel Simulator (LAMMPS) with a reactive force-field (ReaxFF). Furthermore, these simulations suggest that the adsorption mechanisms differ for O 2 and H 2 O adsorption on ZnO, and are governed by the surface termination and the extent of surface hydroxylation. Electrical response measurements, using DC resistance, AC impedance spectroscopy, and Kelvin Probe Force Microscopy (KPFM), demonstrate differences in response to O 2 and H 2 O, confirming that different adsorption mechanisms are involved. Statistical and machine learning approaches were applied to demonstrate that by integrating the electrical and kinetic responses the flexible ZnO sensor can be used for detection and discrimination between O 2 and H 2 O at low temperature.

36 MATERIALS SCIENCE↗

Note: Operation of gamma-ray microcalorimeters at elevated count rates using filters with constraints

Microcalorimeter sensors operated near 0.1 K can measure the energy of individual x- and gamma-ray photons with significantly more precision than conventional semiconductor technologies. Both microcalorimeter arrays and higher per pixel count rates are desirable to increase the total throughput of spectrometers based on these devices. The millisecond recovery time of gamma-ray microcalorimeters and the resulting pulse pileup are significant obstacles to high per pixel count rates. Here, we demonstrate operation of a microcalorimeter detector at elevated count rates by use of convolution filters designed to be orthogonal to the exponential tail of a preceding pulse. These filters allow operation at 50% higher count rates than conventional filters while largely preserving sensor energy resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel 3D Force Sensors for a Cost-Effective 3D Force Plate for Biomechanical Analysis

Three-dimensional force plates are important tools for biomechanics discovery and sports performance practice. However, currently, available 3D force plates lack portability and are often cost-prohibitive. To address this, a recently discovered 3D force sensor technology was used in the fabrication of a prototype force plate. Thirteen participants performed bodyweight and weighted lunges and squats on the prototype force plate and a standard 3D force plate positioned in series to compare forces measured by both force plates and validate the technology. For the lunges, there was excellent agreement between the experimental force plate and the standard force plate in the X-, Y-, and Z-axes (r = 0.950–0.999, p < 0.001). For the squats, there was excellent agreement between the force plates in the Z-axis (r = 0.996, p < 0.001). Across axes and movements, root mean square error (RMSE) ranged from 1.17% to 5.36% between force plates. Although the current prototype force plate is limited in sampling rate, the low RMSEs and extremely high agreement in peak forces provide confidence the novel force sensors have utility in constructing cost-effective and versatile use-case 3D force plates.

42 ENGINEERING↗

Advanced Instrumentation for Extreme Environments

The Department of Energy (DOE) Office of Nuclear Energy (NE) is pursuing embedded instrumentation and controls (I&C) technology for next generation nuclear power generation applications. Embedded systems encompass a wide range of configurations and technologies; we define embedding in this instance as the integration of the sensors and the control system design into the component design using a systems engineering process. Embedded I&C systems are often an essential part of developing new capabilities, improving reliability, enhancing performance, and reducing operational costs. The new intrinsically safe, more efficient, and cost effective reactor technologies (Next Generation Nuclear Plant and Small Modular Reactors) require the development and application of new I&C technologies. These new designs raise extreme environmental challenges such as high temperatures (over 700 C) and material compatibility (e.g., molten salts). The desired reliability and functionality requires measurements in these extreme conditions including high radiation environments which were not previously monitored in real time. The DOE/NE Nuclear Energy Enabling Technologies (NEET) program currently has several projects investigating I&C technologies necessary to make these reactor designs realizable. The project described in this paper has the specific goal of investigating embedded I&C with the following objectives: 1.Explore and quantify the potential gains from embedded I&C improved reliability, increased performance, and reduced cost 2.Identify practical control, sensing, and measurement techniques for the extreme environments found in high-temperature reactors 3.Design and fabricate a functional prototype high-temperature cooling pump for molten salts represents target demonstration of improved performance, reliability, and widespread usage There are many engineering challenges in the design of a high-temperature liquid salt cooling pump. The pump and motor are in direct contact with molten fluoride salt at 700 C (1,292 F) as part of a reactor cooling loop. The motor-pump combination during normal operation would be red-hot (Figure 1). This environment challenges every facet of the design including seals, wiring, magnetic materials, and sensors. In this paper, we discuss the challenges of sensor design in extreme environments and specifically the sensor design for a high-temperature fluoride salt coolant pump. This pump will be used as a test-bed for embedded I&C development and validation in extreme environments.

Extreme Environments↗

Temperature dependent dual hydrogen sensor response of Pd nanoparticle decorated Al doped ZnO surfaces

Sputter deposited Al doped ZnO (AZO) thin films exhibit a dual hydrogen sensing response in the temperature range 40 °C–150 °C after surface modifications with palladium nanoparticles. The unmodified AZO films showed no response in hydrogen in the temperature range 40 °C–150 °C. The operational temperature windows on the low and high temperature sides have been estimated by isolating the semiconductor-to-metal transition temperature zone of the sensor device. The gas response pattern was modeled by considering various adsorption isotherms, which revealed the dominance of heterogeneous adsorption characteristics. The Arrhenius adsorption barrier showed dual variation with change in hydrogen gas concentration on either side of the semiconductor-to-metal transition. A detailed analysis of the hydrogen gas response pattern by considering the changes in nano palladium due to hydrogen adsorption, and semiconductor-to-metal transition of nanocrystalline Al doped ZnO layer due to temperature, along with material characterization studies by glancing incidence X-ray diffraction, atomic force microscopy, and transmission electron microscopy, are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Wireless microwave acoustic sensor system for condition monitoring in power plant environments

This project successfully demonstrated novel wireless microwave acoustic temperature and pressure sensors that can be embedded into equipment and structures located in fossil fuel power plant environments to monitor the condition of components such as steam headers, re-heat lines, water walls, burner tubes, and power turbines. The wireless microwave acoustic sensor technology researched and developed through a collaborative partnership between the University of Maine and Environetix Technologies Corporation can provide a revolutionary impact in the power industry since it is anticipated that the wireless sensors will deliver reliable real-time sensing information in harsh power plant conditions that involve temperatures up to 1100oC and pressures up to 750 psi. The work involved the research and development of novel high temperature harsh environment thin film electrodes, piezoelectric smart microwave acoustic sensing elements, sensor encapsulation materials that were engineered to function over long times up to 1100oC, and a radio-frequency (RF) wireless interrogation electronics unit that are located both inside and outside the high temperature harsh environment. The UMaine / Environetix team have interacted with diverse power plant facilities, and identified as a testbed a local power generation facility, which burns municipal solid waste (MSW), the Penobscot Energy Recovery Company (PERC), Orrington, Maine. In this facility Environetix / UMaine successfully implemented and tested multiple wireless temperature sensor systems within the harsh-environment of the economizer chamber and at the boiler tubes, transferring the developed technology to the power plant environment to perform real-time sensor monitoring experiments under typical operating conditions, as initially targeted in the project. The wireless microwave acoustic sensor technology developed under this project for power plant applications offers several significant advantages including wireless, battery-free, maintenance-free operation, and operation in the harsh-environment of power plant equipment up to about 1100 oC. Their small size and configuration allows flexible sensor placement and embedding of multiple sensor arrays into a variety of components within power systems that can be interrogated by a single RF unit. The outcomes of this project and technological transfer respond to a DOE analysis need, which indicated that if one percent efficiency in coal burning is achieved, an additional 2 gigawatt-hours of energy per year is generated and the resulting coal cost savings is $300 million per year, also accompanied by a reduction of more than 10 million metric tons of CO2 per year emitted into the atmosphere. Therefore, the developed harsh environment wireless microwave acoustic sensor technology and the technological transfer achievements that resulted from the execution of this project have significant impact for power plant equipment and systems and are well-positioned to contribute to the cost reduction in power generation, the increase in power plant efficiency, the improvement in maintenance, the reduction in down-time, and the decrease in environmental pollution. The technology is also in a position to be extended to address other types of high-temperature harsh-environment power plant and energy sector sensing needs.

20 FOSSIL-FUELED POWER PLANTS↗

Using quantum dot photoluminescence for load detection

We propose a novel concept for an integrable and flexible sensor capable to visualize mechanical impacts on lightweight structures by quenching the photoluminescence (PL) of CdSe quantum dots. Considering the requirements such as visibility, storage time and high optical contrast of PL quenching with low power consumption, we have investigated a symmetrical and an asymmetrical layer stack consisting of semiconductor organic N,N,N′,N′-Tetrakis(3-methylphenyl)-3,3′-dimethylbenzidine (HMTPD) and CdSe quantum dots with elongated CdS shell. Time-resolved series of PL spectra from layer stacks with applied voltages of different polarity and simultaneous observation of power consumption have shown that a variety of mechanisms such as photo-induced charge separation and charge injection, cause PL quenching. However, mechanisms such as screening of external field as well as Auger-assisted charge ejection is working contrary to that. Investigations regarding the influence of illumination revealed that the positive biased asymmetrical layer stack is the preferred sensor configuration, due to a charge carrier injection at voltages of 10 V without the need of coincident illumination.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Synergistic smart fuel for in-pile nuclear reactor measurements

The thermo-acoustic fuel rod sensor developed in this research has demonstrated a novel technique for monitoring the temperature within the core of a nuclear reactor or the temperature of the surrounding heat-transfer fluid. It uses the heat from the nuclear fuel to generate sustained acoustic oscillations whose frequency will be indicative of the temperature. Converting a nuclear fuel rod into this type of thermo-acoustic sensor simply requires the insertion of a porous material (stack). This sensor has demonstrated a synergy with the elevated temperatures that exist within the nuclear reactor using materials that have only minimal susceptibility to high-energy particle fluxes. When the sensor is in operation, the sound waves radiated from the fuel rod resonator will propagate through the surrounding cooling fluid. The frequency of these oscillations is directly correlated with an effective temperature within the fuel rod resonator. This device is self-powered and is operational even in case of total loss of power of the reactor.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Optimization of Thermal Neutron Converter in SiC Sensors for Spectral Radiation Measurements

Optimization of the neutron converter in SiC sensors is presented. The sensors are used for spectral radiation measurements of thermal and fast neutrons and optionally gamma ray at elevated temperature in harsh radiation environment. The neutron converter, which is based on 10B, allows to detect thermal neutrons by means of neutron capture reaction. Two construction of the sensors were used to measure radiation in experiments. Sensor responses collected in experiments have been reproduced by the computer tool created by authors, it allows to validate the tool. The tool creates the response matrix function describing the characteristic of the sensors and it was used for detailed analyses of the sensor responses. Obtained results help to optimize the neutron converter in order to increase thermal neutron detection. Several enhanced construction of the sensors, which includes the neutron converter based on {sup 10}B or {sup 6}Li, were proposed. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PORTFOLIO OF POTENTIAL STRATEGIES IN AERONAUTIC MAINTENANCE

EADS divisions aim more and more at developing services associated to their platforms. EADS divisions, like Airbus and Eurocopter, are investigating on services associated to their platforms in order to add them value. One possible service consists in structural maintenance operation assistance, especially for NDT operations performed by the customer. EADS Innovation Works envisages three different and complementary enhanced structural maintenance categories. Enhanced NDT improves standard NDT operation environment. This is made possible by the existence of 'smart' NDT tools that are computer based and therefore able to support other functions. These functions range from local smart data processing and display to remote expert assisted operation. Passive Sensor Network relies on sensors permanently installed on aircraft structure. Interrogation of sensors is performed on ground and off line (while structure is not loaded except by its own weight). It can be done at arbitrary times in order to determine structure health. The aim is to give easy access to some hidden ''hot spots,'' to reduce human factor in structure health assessment and optimize maintenance. Structural Health Monitoring goes a step beyond Passive Sensor Network, because interrogation units are on board the aircraft and may be connected to aircraft network. It allows to use on-line techniques such as adapted acoustic emission and to automatically raise an alarm when a defect appears in the structure. This paper presents these different ways of improving structural maintenance operations in service, with their respective advantages and limitations.

36 MATERIALS SCIENCE↗

Modeling the dark current histogram induced by gold contamination in complementary-metal-oxide-semiconductor image sensors

We propose a model for dark current induced by metallic contamination in a CMOS image sensor. Based on Shockley-Read-Hall kinetics, the expression of dark current proposed accounts for the electric field enhanced emission factor due to the Poole-Frenkel barrier lowering and phonon-assisted tunneling mechanisms. To that aim, we considered the distribution of the electric field magnitude and metal atoms in the depth of the pixel. Poisson statistics were used to estimate the random distribution of metal atoms in each pixel for a given contamination dose. Then, we performed a Monte-Carlo-based simulation for each pixel to set the number of metal atoms the pixel contained and the enhancement factor each atom underwent, and obtained a histogram of the number of pixels versus dark current for the full sensor. Excellent agreement with the dark current histogram measured on an ion-implanted gold-contaminated imager has been achieved, in particular, for the description of the distribution tails due to the pixel regions in which the contaminant atoms undergo a large electric field. The agreement remains very good when increasing the temperature by 15 °C. We demonstrated that the amplification of the dark current generated for the typical electric fields encountered in the CMOS image sensors, which depends on the nature of the metal contaminant, may become very large at high electric field. The electron and hole emissions and the resulting enhancement factor are described as a function of the trap characteristics, electric field, and temperature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Instrumentation with Hall sensors for JET magnetic diagnostics. The results of the recent deuterium campaign at JET in 2009

Magnetic diagnostics is one of the main diagnostics in thermonuclear reactors, and thus enhancing the accuracy of the magnetic field measurement is a relevant task. The paper discusses the principles of construction for magnetic measuring instrumentation based upon the application of steady-state radiation-resistant semiconductor sensors, and the results of its implementation for magnetic field measurement in one of the largest operating reactors JET (Joint European Torus) during the recent deuterium campaign. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging of moving fiducial markers during radiotherapy using a fast, efficient active pixel sensor based EPID

Purpose: The purpose of this work was to investigate the use of an experimental complementary metal-oxide-semiconductor (CMOS) active pixel sensor (APS) for tracking of moving fiducial markers during radiotherapy. Methods: The APS has an active area of 5.4 x 5.4 cm and maximum full frame read-out rate of 20 frame s{sup -1}, with the option to read out a region-of-interest (ROI) at an increased rate. It was coupled to a 4 mm thick ZnWO4 scintillator which provided a quantum efficiency (QE) of 8% for a 6 MV x-ray treatment beam. The APS was compared with a standard iViewGT flat panel amorphous Silicon (a-Si) electronic portal imaging device (EPID), with a QE of 0.34% and a frame-rate of 2.5 frame s{sup -1}. To investigate the ability of the two systems to image markers, four gold cylinders of length 8 mm and diameter 0.8, 1.2, 1.6, and 2 mm were placed on a motion-platform. Images of the stationary markers were acquired using the APS at a frame-rate of 20 frame s{sup -1}, and a dose-rate of 143 MU min{sup -1} to avoid saturation. EPID images were acquired at the maximum frame-rate of 2.5 frame s{sup -1}, and a reduced dose-rate of 19 MU min{sup -1} to provide a similar dose per frame to the APS. Signal-to-noise ratio (SNR) of the background signal and contrast-to-noise ratio (CNR) of the marker signal relative to the background were evaluated for both imagers at doses of 0.125 to 2 MU. Results: Image quality and marker visibility was found to be greater in the APS with SNR {approx}5 times greater than in the EPID and CNR up to an order of magnitude greater for all four markers. To investigate the ability to image and track moving markers the motion-platform was moved to simulate a breathing cycle with period 6 s, amplitude 20 mm and maximum speed 13.2 mm s{sup -1}. At the minimum integration time of 50 ms a tracking algorithm applied to the APS data found all four markers with a success rate of {>=}92% and positional error {<=}90 {mu}m. At an integration time of 400 ms the smallest marker became difficult to detect when moving. The detection of moving markers using the a-Si EPID was difficult even at the maximum dose-rate of 592 MU min{sup -1} due to the lower QE and longer integration time of 400 ms. Conclusions: This work demonstrates that a fast read-out, high QE APS may be useful in the tracking of moving fiducial markers during radiotherapy. Further study is required to investigate the tracking of markers moving in 3D in a treatment beam attenuated by moving patient anatomy. This will require a larger sensor with ROI read-out to maintain speed and a manageable data-rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗