Search NASA⌕ Search

SEARCH · Search NASA

Results for “matrix sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Gaussian windows: A tool for exploring multivariate data

Presented here is a method for interactively exploring a large set of quantitative multivariate data, in order to estimate the shape of the underlying density function. It is assumed that the density function is more or less smooth, but no other specific assumptions are made concerning its structure. The local structure of the data in a given region may be examined by viewing the data through a Gaussian window, whose location and shape are chosen by the user. A Gaussian window is defined by giving each data point a weight based on a multivariate Gaussian function. The weighted sample mean and sample covariance matrix are then computed, using the weights attached to the data points. These quantities are used to compute an estimate of the shape of the density function in the window region. The local structure of the data is described by a method similar to the method of principal components. By taking many such local views of the data, we can form an idea of the structure of the data set. The method is applicable in any number of dimensions. The method can be used to find and describe simple structural features such as peaks, valleys, and saddle points in the density function, and also extended structures in higher dimensions. With some practice, we can apply our geometrical intuition to these structural features in any number of dimensions, so that we can think about and describe the structure of the data. Since the computations involved are relatively simple, the method can easily be implemented on a small computer.

Jaeckel, Louis A.↗

Stable isotope analysis of molecular oxygen from silicates and oxides using CO2 laser extraction

A laser-excited system for determination of the oxygen isotope composition of small quantities of silicate and oxide minerals was constructed and tested at JSC. This device is the first reported to use a commercially available helium cryostat to transfer and purify oxygen gas quantitatively within the system. The system uses oxygen gas instead of the conventional CO2 for mass spectrometer analyses. This modification of technique permits determination of all three stable oxygen isotopes, an essential requirement for oxygen isotope analysis of meteoritic material. Tests of the system included analysis of standard silicate materials NBS 28 and UWMG2 garnet, six SNC meteorites, and inclusions and chondrules from the Allende meteorite. Calibration with terrestrial standards was excellent. Meteorite values are close to published values and show no evidence of terrestrial oxygen contamination. The one limitation observed is that, in some runs on fine-grained SNC matrix material, sample results were affected by other samples in the sample holder within the reaction chamber. This reemphasizes the need for special precautions in dealing with fine-grained, reactive samples. Performance of the JSC instrument compares favorably with that of any other instrument currently producing published oxygen isotope data.

Perry, Eugene↗

Comparison of the Lithologies on the Surface of the Asteroid 4 Vesta Based on the Petrology of 91 and 92 Series Antarctic Achondrites

We studied meteorite sections PCA91179,9; EET92003,14; EET92025,5; EET92026,4; and EET92027,5 t determine lithological variations on the surface of the asteroid 4 Vesta. These are brecciated polymict eucrites. The clasts contained within these samples and the matrix which surrounds them in each sample provide a random sampling of the characteristic compositions found on the surface of asteroid 4 Vesta.

Source record↗

Ultrasonic Guided-Wave Scan System Used to Characterize Microstructure and Defects in Ceramic Composites

Ceramic matrix composites (CMCs) are being developed for advanced aerospace propulsion applications to save weight, improve reuse capability, and increase performance. However, mechanical and environmental loads applied to CMCs can cause discrete flaws and distributed microdamage, significantly reducing desirable physical properties. Such microdamage includes fiber/matrix debonding (interface failure), matrix microcracking, fiber fracture and buckling, oxidation, and second phase formation. A recent study (ref. 1) of the durability of a C/SiC CMC discussed the requirement for improved nondestructive evaluation (NDE) methods for monitoring degradation in these materials. Distributed microdamage in CMCs has proven difficult to characterize nondestructively because of the complex microstructure and macrostructure of these materials. This year, an ultrasonic guided-wave scan system developed at the NASA Glenn Research Center was used to characterize various microstructural and flaw conditions in SiC/SiC (silicon carbide fiber in silicon carbide matrix) and C/SiC (carbon fiber in silicon carbide matrix) CMC samples.

Roth, Don J.↗

Signal Processing Variables for Optimization of Flaw Detection in Composites Using Ultrasonic Guided Wave Scanning

This study analyzes the effect of signal processing variables on the ability of the ultrasonic guided wave scan method at NASA Glenn Research Center to distinguish various flaw conditions in ceramic matrix composites samples. In the ultrasonic guided wave scan method, several time- and frequency-domain parameters are calculated from the ultrasonic guided wave signal at each scan location to form images. The parameters include power spectral density, centroid mean time, total energy (zeroth moment), centroid frequency, and ultrasonic decay rate. A number of signal processing variables are available to the user when calculating these parameters. These signal processing variables include 1) the time portion of the time-domain waveform processed, 2) integration type for the properties requiring integrations, 3) bounded versus unbounded integrations, 4) power spectral density window type, 5) and the number of time segments chosen if using the short-time fourier transform to calculate ultrasonic decay rate. Flaw conditions examined included delamination, cracking, and density variation.

Roth, Don J.↗

A Data Matrix Method for Improving the Quantification of Element Percentages of SEM/EDX Analysis

A simple 2D M N matrix involving sample preparation enables the microanalyst to peer below the noise floor of element percentages reported by the SEM/EDX (scanning electron microscopy/ energy dispersive x-ray) analysis, thus yielding more meaningful data. Using the example of a 2 3 sample set, there are M = 2 concentration levels of the original mix under test: 10 percent ilmenite (90 percent silica) and 20 percent ilmenite (80 percent silica). For each of these M samples, N = 3 separate SEM/EDX samples were drawn. In this test, ilmenite is the element of interest. By plotting the linear trend of the M sample s known concentration versus the average of the N samples, a much higher resolution of elemental analysis can be performed. The resulting trend also shows how the noise is affecting the data, and at what point (of smaller concentrations) is it impractical to try to extract any further useful data.

Lane, John↗

The Fission Accelerated Steady State Test (FAST) -- A Revised Capsule Design for the Accelerated Testing of Advanced Reactor Fuels

In an effort to improve the development and testing of novel nuclear fuels, a detailed evaluation on reducing the size of fuel specimens for irradiation has been performed. Theoretically speaking, reducing the fuels diameter and incorporating an inner capsule while maintaining the original outside diameter of the experiment significantly reduces the experiment’s sensitivity to fabrication tolerances and drastically reduces the time necessary to reach a desired fuel burnup; both of which improve the cost and schedule associated with the fuel testing. Simulations of this reduced diameter, double encapsulated concept have been performed using Abaqus, MCNP, and ORIGEN. The results of the Abaqus simulations are beyond the scope of this summary and will not be presented herein. For results of these Abaqus simulations, see Beausoleil [2]. The models were tested using various parameters and design deviations which were then compared to the original Advanced Fuels Campaign (AFC) designs. The results of these simulations confirmed that the introduction of a second capsule coupled to a reduction in the fuel pin diameter significantly reduces the experiment’s sensitivity to fabrication tolerances and reduces the time to reach a desired burnup by nearly an order of magnitude. The original AFC design requires approximately 11.7 years to reach 30 Atom % Heavy Metal (at% HM) burnup. A burnup of 30 at% HM can be reached in approximately 2.5 to 3.5 years (irradiation position dependent) with a fuel diameter ½ (~0.097 in. diameter) that of the original AFC design. An added benefit to the fuel pin diameter reduction is that more specimens can be irradiated in any given cycle. Essentially, significantly more specimens can be tested and incur more burnup over a given operating cycle relative to the AFC design. This allows the development of a large test matrix of samples with rapid throughput in ATR.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Replacing a 252Cf source with a neutron generator in a shuffler - a conceptual design performed with MCNPX

The {sup 252}Cf shuffler has been widely used in nuclear safeguards and radioactive waste management to assay fissile isotopes, such as {sup 235}U or {sup 239}Pu, present in a variety of samples, ranging from small cans of uranium waste to metal samples weighing several kilograms. Like other non-destructive assay instruments, the shuffler uses an interrogating neutron source to induce fissions in the sample. Although shufflers with {sup 252}Cf sources have been reliably used for several decades, replacing this isotopic source with a neutron generator presents some distinct advantages. Neutron generators can be run in a continuous or pulsed mode, and may be turned off, eliminating the need for shielding and a shuffling mechanism in the shuffler. There is also essentially no dose to personnel during installation, and no reliance on the availability of {sup 252}Cf. Despite these advantages, the more energetic neutrons emitted from the neutron generator (141 MeV for D-T generators) present some challenges for certain material types. For example when the enrichment of a uranium sample is unknown, the fission of {sup 238}U is generally undesirable. Since measuring uranium is one of the main uses of a shuffler, reducing the delayed neutron contribution from {sup 238}U is desirable. Hence, the shuffler hardware must be modified to accommodate a moderator configuration near the source to tailor the interrogating spectrum in a manner which promotes sub-threshold fissions (below 1 MeV) but avoids the over-moderation of the interrogating neutrons so as to avoid self-shielding. In this study, where there are many material and geometry combinations, the Monte Carlo N-Particle eXtended (MCNPX) transport code was used to model, design, and optimize the moderator configuration within the shuffler geometry. The code is then used to evaluate and compare the assay performances of both the modified shuffler and the current {sup 252}Cf shuffler designs for different test samples. The matrix effect and the non-uniformity of the interrogating flux are investigated and quantified in each case. The modified geometry proposed by this study can serve s a guide in retrofitting shufflers that are already in use.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Nickel Content on Microstructural Evolution in Austempered Solution-Strengthened Ferritic Ductile Cast Iron

The effects of Ni content and austempering temperature on microstructural evolution during austempering in solution-strengthened ferritic ductile cast iron with Ni contents between 0 and 1.1 mass% were investigated. The microstructure observation for the samples austempered at temperatures between 375 and 325 °C using an infrared gold image furnace was carried out with optical microscopy, x-ray diffraction measurements, and electron back-scattered diffraction pattern (EBSP) analysis. In addition, the Vickers hardness of both the austempered and as-quenched samples was measured under a load of 0.9807 N. According to the microstructure observations, the matrix of the samples austempered at temperatures between 375 and 325 °C exhibited finer acicular ferrite microstructure with increasing Ni content. Optical microscopy and EBSP analysis revealed that the amount of high-carbon austenite phase for the austempered samples increased with increasing Ni content and austempering temperature. Although samples with higher Ni content were found to contain more high-carbon austenite phase in the matrix, the Vickers hardness of the samples tended to increase with increasing Ni content at the same austempering temperature. The reason for this may be the higher carbon content in the matrix of the samples with higher Ni contents.

36 MATERIALS SCIENCE↗

Apollo 17, Station 6 boulder sample 76255 - Absolute petrology of breccia matrix and igneous clasts

The matrix of 76255 is the finest-grained, most clast-laden, impact-melt polymict breccia sampled from the Station 6 boulder. The paper speculates on how the matrix of 76255 fits into and enhances existing thermal models of breccia lithification. Emphasis is on the detailed petrology of five lithic clasts, two of which display mineralogical and textural affinities to mare basalts, while three, a gabbro, a norite, and a troctolite are considered primitive plutonic rocks.

Warner, J. L.↗

A Classical-Quantum Hybrid Approach for Unsupervised Probabilistic Machine Learning

For training unsupervised probabilistic machine learning models, matrix computation and sample generation are the two key steps. While GPUs excel at matrix computation, they use pseudo-random numbers to generate samples. Contrarily, Adiabatic Quantum Processors (AQP) use quantum mechanical systems to generate samples accurately and quickly, but are not suited for matrix computation. We present a Classical-Quantum Hybrid Approach for training unsupervised probabilistic machine learning models, leveraging GPUs for matrix computations and the D-Wave quantum sampling library for sample generation. We compare this approach to classical and quantum approaches across four performance metrics. Our results indicate that while the hybrid approach–which uses one AQP and one GPU–outperforms quantum and one of the classical approaches, it performs comparably to the GPU approach, and is outperformed by the CPU approach, which uses 56 high-end CPUs. Lastly, we compare sampling on AQP versus sampling library and show that AQP performs better.

Date, Prasanna↗

Randomized Algorithms for Low-Rank Matrix and Tensor Decompositions

This paper surveys randomized algorithms in numerical linear algebra for low-rank decompositions of matrices and tensors. The survey begins with a review of classical matrix algorithms that can be accelerated by randomized dimensionality reduction, such as the singular value decomposition (SVD) or interpolative (ID) and CUR decompositions. Recent advances in randomized dimensionality reduction are discussed, including new methods of fast matrix sketching and sampling techniques, which are incorporated into classical matrix algorithms for fast low-rank matrix approximations. The extension of randomized matrix algorithms to tensors is then explored for several low-rank tensor decompositions in the CP and Tucker formats, including the higher-order SVD, ID, and CUR decomposition.

Pearce, Katherine J. [The University of Texas at A↗

Fabrication and characterization of microstructure of stainless steel matrix composites containing up to 25 vol% NbC

AISI 440 stainless steels reinforced with various volume fractions of niobium carbide (NbC) particles of up to 25 vol% were fabricated in-situ using an argon arc furnace and then heat-treated to produce a martensitic matrix. Optical and scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS) and electron back-scatter diffraction (EBSD) techniques were used to analyze the microstructure, phases and composition of these composites. Interestingly, it was found that Chinese-script NbC could nucleate on existing primary NbC particles creating NbC clusters with complex microstructures. Additionally, hardness tests were used to evaluate viability in mining and mineral processing applications. The increase in NbC content resulted in an overall increase in the hardness of the composites while causing a marginal decrease in the amount of Cr in solid solution with the matrix, which could be a concern for corrosion resistance. The latter was due to the fact that the NbC lattice could dissolve a minor amount of Cr. Thermodynamic simulations also attributed this to a slight increase in M{sub 7}C{sub 3} precipitation. Nonetheless, these novel composites show great promise for applications in wear and corrosive environments. - Highlights: •Stainless steels reinforced with NbC particles of up to 25 vol% were fabricated. •NbC was formed in-situ in the steels using an arc melter. •Martensitic transformation of the matrix of each sample was achieved. •NbC reinforcements increased the bulk hardness values of the steels. •Dissolved Cr in the matrix of each sample was sufficient for passivity in theory.

36 MATERIALS SCIENCE↗

Effect of sintering time on structural, microstructural and chemical composition of Ni-doped lanthanum gallate perovskites

This work reports the effect of two different sintering times, 6 and 48 h on the structural, microstructural, and chemical features of Ni-doped La{sub 0.90}Sr{sub 0.10}GaO{sub 3.00−δ}. Independently of the sintering time, La{sub 0.90}Sr{sub 0.10}Ga{sub 1−x}Ni{sub x}O{sub 3.00−δ} (where x=0.10, and 0.20 (mol)) presents a rhombohedral symmetry with a lattice volume that decreases when NiO dopant increases. Besides the perovskite, LaSrGa{sub 3.00}O{sub 7.00} (nominal composition) is present as second phase in all cases. When the samples are doped with NiO, the peaks of this second phase are shifted with respect to the peaks of the pure phase. These shifts suggest that this second phase could admit some Ni ions in its structure. According to the XRD patterns, the amount of the latter phase is larger when sintering time is increased. Electron probe microanalysis (EPMA) indicated that the matrix of the samples sintered for 6 h is constituted by a perovskite with an experimental composition very close to the nominal one. However, when the samples are sintered for 48 h the matrix of each sample is constituted by two perovskites; both with compositional deviations with respect to their nominal one. In particular, a significant Sr depletion compensated by a La increment in the A site is observed. Those compositional deviations could be mainly due to the diffusion of the cations in the bulk and/or from the bulk to the surface of the samples. That diffusion can favour the formation, not only, of a second perovskite with a different composition in relation with the first one formed, but also, the formation of second phases. In addition, a very slight broadening of Bragg peaks of the perovskites sintered for 48 h is observed by XRD and can be related to the presence of two different perovskites in each sample according to EPMA results. By BSEM and EPMA analyses La{sub 4.00}Ga{sub 2.00}O{sub 9.00} (nominal composition) is also observed as second phase when samples are treated for 48 h. - Graphical abstract: Typical microstructures, observed by FEG-SEM, of La{sub 0.90}Sr{sub 0.10}Ga{sub 1−x}Ni{sub x}O{sub 3.00−δ} materials with x=0.00 and 0.10 (nominal compositions) and sintered at 1450 °C for 48 h after polishing and thermal etching are shown. Lighter grey grains with a bimodal grain size are observed and according to XEDS analysis correspond to two perovskites with different experimental compositions (labelled as 1 and 2 for x=0.00 and labelled as 4 and 5 for x=0.10, respectively), meanwhile the darker grey phases correspond to LaSrGa{sub 3.00}O{sub 7.00} (labelled as 3 for x=0.00) and LaSr(Ga{sub 1−y′},Ni{sub y′}){sub 3.00}O{sub 7.00} (labelled as 6 for x=0.10), respectively. - Highlights: • When NiO is introduced into La{sub 0.90}Sr{sub 0.10}GaO{sub 3.00−δ} a change in symmetry is produced. • A significant Sr depletion in the A-site of perovskites treated for 48 h is observed. • Compositional deviations could be due to a thermally-activated diffusional process. • The phase purity of these materials is deteriorated when the sintering time is extended.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Space environmental effects on polymer matrix composites as a function of sample location on LDEF

This paper presents results on the effect of circumferential location on the variation in solar absorptance (alpha(sub S)) and infrared emittance (epsilon) for five different polymer matrix composites (PMC), and variations in erosion depth due to atomic oxygen (AO) for fourteen different PMC materials. In addition, a chemical content design parameter (gamma) has been found that correlates well with the erosion yield obtained from space flight data and hyperthermal AO tests for hydrocarbon polymeric materials. This parameter defines the ratio of the total number of atoms in a repeat monomer unit to the difference between the total carbon content and the total number of intermolecular oxygen atoms in the same repeat unit.

Tennyson, R. C.↗

Incipient Melt Formation and Devitrification at the Wanapitei Impact Structure, Ontario, Canada

The Wanapitei impact structure is approximately 8 km in diameter and lies within Wanapitei Lake, approximately 34 km northeast of the city of Sudbury. Rocks related to the 37 Ma impact event are found only in Pleistocene glacial deposits south of the lake. Most of the target rocks are metasedimentary rocks of the Proterozoic Huronian Supergroup. An almost completely vitrified, inclusion-bearing sample investigated here represents either an impact melt or a strongly shock metamorphosed, pebbly wacke. In the second, preferred interpretation, a number of partially melted and devitrified clasts are enclosed in an equally highly shock metamorphosed arkosic wacke matrix (i.e., the sample is a shocked pebbly wacke), which records the onset of shock melting. This interpretation is based on the glass composition, mineral relicts in the glass, relict rock textures, and the similar degree of shock metamorphism and incipient melting of all sample components. Boulder matrix and clasts are largely vitrified and preserve various degrees of fluidization, vesiculation, and devitrification. Peak shock pressure of approximately 50-60 GPa and stress experienced by the sample were somewhat below those required for complete melting and development of a homogeneous melt. The rapid cooling and devitrification history of the analyzed sample is comparable to that reported recently from glasses in the suevite of the Ries impact structure in Germany and may indicate that the analyzed sample experienced an annealing temperature after deposition of somewhere between 650 C and 800 C.

Dressler, B. O.↗

X-Ray Fluorescence Quantitative and Qualitative Analysis Using Micro Glass Beads

The fused glass bead method is the accepted 'best practice' method of preparation of samples for X-ray fluorescence (XRF) analysis. It minimizes the effects of sample heterogeneity and simplifies calibration by dissolving the sample into a uniform glass matrix. Glass fusion XRF samples are typically prepared by grinding sample powder with Lithium Tetraborate / Lithium Bromide and fusing the mixture at 1000 deg. C. In most cases sample-to-flux ratios of between 1:1 to 1:10 are used (1:1 for determination of trace elements and 1:10 for major elements). Typical sample mass consumed is in the range of 1000 to 2500 mg. It would be advantageous to reduce this sample mass in cases where the sample material is rare, valuable or highly radioactive. This study examines the effects of using lower sample-to-flux ratios and smaller fusion bead size on the detection and quantification of major and trace elements by XRF analysis. We have employed a micro fused glass bead process, using sample-to-flux ratios of 1:10, 1:15 and 1:25, to determine the effects on measurement precision, accuracy and detection limit. Objectives: - Created micro fused glass beads of a series of standards and andesite sample with sample-to-flux ratios of 1:10, 1:15 and 1:25. - Perform an qualitative analysis of the different sample-to-flux ratio micro beads and compare the results with the 1:5.3 beads routinely used at SRNL. - Quantitate the major components in the different sample-to-flux ratio micro beads using a wavelength dispersive x-ray fluorescence instrument. Advantages: - Reduce sample amount needed. - Speed up waste tank characterization. - Reduce personnel exposure. - Potential sealed source. Fused micro glass beads with sample-to-flux ratios of 1:10, 1:15 and 1:25 were created using sample amounts of 123 mg, 82 mg and 52 mg respectively. It was possible to detect most of the major oxides and some trace elements in the fused micro glass beads with different sample-to-flux ratios. The quantitative analysis showed good linear correlation between the intensity of the analysis and the concentration of the elements. Good precision and accuracy results were obtained for the majority of the major oxides in the three fused micro glass beads with different sample-to-flux ratios. Path Forward: Enhance the precision and accuracy of the method by optimizing different sample preparation steps, such as weighing and sample transfer. Continue to increase the sample-to-flux ratio to determine the minimum amount of sample needed to perform a multielement analysis. Consider the use of synthetic standards to lower the detection limit of the analysis. Used the micro bead sample preparation method to analyze radioactive samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Combined infrared and ultraviolet-visible spectroscopy matrix-isolated carbon vapor

Infrared and UV-visible absorption spectra have been measured on the same sample of matrix-isolated carbon vapor in order to establish correlations between absorption intensities of vibrational and electronic transitions as a function of sample annealing. A high degree of correlation has been found between the IR feature at 1998/cm recently assigned to C8 and a UV absorption feature at about 3100 A. Thus, for the first time, direct evidence is given for the assignment of one of the unknown UV-visible features of the long-studied matrix-isolated carbon vapor spectrum.

Kurtz, Joe↗