Search NASA⌕ Search

SEARCH · Search NASA

Results for “matrix sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Evaluation of Annealing Treatments for Producing Si-Rich Fuel/Matrix Interaction Layers in Low-Enriched U-Mo Dispersion Fuel Plates Rolled at a Low Temperature

During fabrication of U-7Mo dispersion fuels, exposure to relatively high temperatures affects the final microstructure of a fuel plate before it is inserted into a reactor. One impact of this high temperature exposure is a chemical interaction that can occur between dissimilar materials. For U-7Mo dispersion fuels, the U-7Mo particles will interact to some extent with the Al or Al alloy matrix to produce interaction products. It has been observed that the final irradiation behavior of a fuel plate can depend on the amount of interaction that occurs at the U-7Mo/matrix interface during fabrication, along with the type of phases that develop at this interface. For the case where a U-7Mo dispersion fuel has a Si-containing Al alloy matrix and is rolled at around 500°C, a Si-rich interaction product has been observed to form that can potentially have a positive impact on fuel performance during irradiation. This interaction product can exhibit stable irradiation behavior and it can act as a diffusion barrier to additional U-Mo/matrix interaction during irradiation. However, for U-7Mo dispersion fuels with softer claddings that are rolled at lower temperatures (e.g., near 425°C), a significant interaction layer has not been observed to form. As a result, the bulk of any interaction layer that develops in these fuels happens during irradiation, and the layer that forms may not exhibit as stable a behavior as one that is formed during fabrication. Therefore, it may be beneficial to add a heat treatment step during the fabrication of dispersion fuel plates with softer cladding alloys that will result in the formation of a uniform, Si-rich interaction layer that is a few microns thick around the U-Mo fuel particles. This type of layer would have characteristics like the one that has been observed in dispersion fuel plates with AA6061 cladding that are fabricated at 500°C, which may exhibit increased stability during irradiation. This report discusses the result of annealing experiments that were performed using samples from fuel plates that were fabricated at 425°C that had Alloy 5052 cladding. As part of these experiments, samples with Al-Si matrices that had different Si contents were tested. The samples had Al-2Si, Al-4Si, Al-5Si, or Al-6Si as the matrix alloy. The heat treatment temperatures and times that were investigated were 450°C (4 hours), 475°C (4 hours), and 500°C (2 hours) for all the matrix alloy compositions and 525°C (1 hour) for just the Al-4Si and Al-6Si matrix alloy compositions. The results of these experiments showed that the initial interaction layers that form around the U-7Mo particles during fabrication at 425°C continue to grow in thickness and uniformity during each of the heat treatments, though the composition of the layers remains similar to that observed in the as-fabricated samples. The Al-6Si matrix sample annealed at 450°C for 4 hours and the Al-5Si and Al-6Si matrix samples annealed at 475°C for 4 hours formed fuel/matrix interaction layers most similar to those observed in fuel plates with AA6061 cladding that are fabricated at 500°C.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Interaction picture density matrix quantum Monte Carlo

The recently developed density matrix quantum Monte Carlo (DMQMC) algorithm stochastically samples the N-body thermal density matrix and hence provides access to exact properties of many-particle quantum systems at arbitrary temperatures. We demonstrate that moving to the interaction picture provides substantial benefits when applying DMQMC to interacting fermions. In this first study, we focus on a system of much recent interest: the uniform electron gas in the warm dense regime. The basis set incompleteness error at finite temperature is investigated and extrapolated via a simple Monte Carlo sampling procedure. Finally, we provide benchmark calculations for a four-electron system, comparing our results to previous work where possible.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An Evaluation of Actinide Reactivity with CO 2 , O 2 , and O 2 /He Gases using Inductively Coupled Plasma Tandem Mass Spectrometry: Application to Simultaneous Measurement of 241 Am/ 241 Pu Ratios in Unseparated Complex Matrices

Accurate actinide measurements are critical within the field of nuclear science. Traditional methods for actinide quantification require time-consuming sample processing prior to analysis. There is a need for rapid analytical techniques that still maintain a high degree of accuracy. In this work, actinide reactivity was assessed for multiple oxygen-containing reaction gases using quadrupole inductively coupled plasma tandem mass spectrometry (Q-ICP-MS/MS) to evaluate actinide analysis in complex sample matrices without analyte-matrix separation. A novel method was developed to measure 241 Am/ 241 Pu in complex sample matrices using O 2 /He reaction gas with no matrix removal or analyte pre-concentration. This inline method reduces matrix-derived polyatomic interferences that complicate traditional ICP-MS analyses by mass-shifting to 241 Am 16 O + and 241 Pu 16 O 2 + , allowing Am and Pu to be mass separated for simultaneous analysis. While mass shifting is efficient, a small portion of Am + (<1.3%) and Pu + (<1.4%) react to from AmO 2 + and PuO + , respectively. Therefore, a mass balance approach was used, in combination with reactivity determined from 242 Pu and 243 Am standard solutions, to correct for residual 241 PuO + and 241 AmO 2 + . The method was validated by measuring 241 Am/ 241 Pu in Pu isotope standards CRM-136 and CRM-137 (separated in March/April 1970 and February 2022, respectively) in both neat solutions and complex matrices containing diluted soil (NIST SRM 2711a, >1000 µg·g -1 ). Method detection limits of 15.9 and 9.6 fg·g -1 were determined for 241 Am and 241 Pu, respectively, and 241 Am/ 241 Pu ratios were measured with accuracies within <3.5%. In conclusion, this work presents the first direct analysis of 241 Am/ 241 Pu in unseparated complex matrices, advancing capabilities for rapid actinide measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Positron accumulation effect in particles embedded in a low-density matrix

Systematic studies of the so-called positron accumulation effect for samples with particles embedded in a matrix are reported. This effect is related to energetic positrons which penetrate inhomogeneous medium. Due to differences in the linear absorption coefficient, different amounts of positrons are accumulated and annihilate in the identical volume of both materials. Positron lifetime spectroscopy and Doppler broadening of the annihilation line using Na-22 positrons were applied to the studies of the epoxy resin samples with embedded micro-sized particles of transition metals, i.e., Ni, Sn, Mo, W, and nonmetal particles, i.e., Si and NaF. The significant difference between the determined fraction of positrons annihilating in the particles and the particle volume fraction indicates the positron accumulation effect. The simple phenomenological model and Monte Carlo simulations are able to describe the main features of the obtained dependencies. The aluminum alloy with embedded Sn nanoparticles is also considered for demonstration differences between the accumulation and another related effect, i.e., the positron affinity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Toward shell model interactions with credible uncertainties

Background: The nuclear shell model is a powerful framework for predicting nuclear structure observables, but relies on interaction matrix elements fit to experimental data as its inputs. Extending the shell model's applicability, particularly toward dripline nuclei, requires efficient fitting methods and credible uncertainty quantification. Traditional approaches face computational challenges and may underestimate uncertainties. Purpose: We develop and test a framework combining eigenvector continuation and Markov chain Monte Carlo to efficiently fit shell model interaction matrix elements and quantify their uncertainties. Methods: Eigenvector continuation is used to emulate shell model calculations, reducing computational costs. The emulator enables Markov chain Monte Carlo sampling to optimize interaction matrix elements and rigorously assess parametric uncertainties. Here, the framework is benchmarked using the USDB interaction in the 𝑠⁢𝑑 shell. Results: The emulator reproduces the USDB interaction with negligible error, validating its use in shell model fitting applications. However, we find that to obtain credible predictive intervals, the model defect of the shell model itself, rather than experimental or emulator error, must be taken into account in order to obtain credible uncertainties. Conclusions: The proposed framework provides an efficient and rigorous approach for fitting shell model interactions and quantifying uncertainties. Further, the normality assumption used in the past appears sufficient to describe the distribution of interaction matrix elements. However, it is crucial to account for model correlations to avoid underestimating uncertainties.

Nuclear forces↗

Tile-Based Fisher Ratio Analysis of Comprehensive Two-Dimensional Gas Chromatography Time-of-Flight Mass Spectrometry (GC × GC – TOFMS) Data using a Null Distribution Approach

Multi-dimensional chromatographic instrumentation produces information-rich, and chemically complex data containing meaningful chemical signals and/or chemical patterns. Two-dimensional gas chromatography coupled with time-of-flight mass spectrometry (GC × GC – TOFMS) is a prominent instrumental platform that has been applied extensively for discovery-based experimentation, where samples are sufficiently volatile or amenable to derivatization. Use of GC × GC – TOFMS and associated data analysis strategies aim to uncover meaningful chemical signals or chemical patterns. However, for complex samples, meaningful chemical information is often buried in a background of less meaningful chemical signal and noise. In this report, we utilize the tile-based F-ratio software in concert with the standard addition method by spiking non-native chemicals into a diesel fuel matrix at low concentrations. While the previous work studied the concentration range of 100-1000 ppm, the current study focuses on the 0 ppm to 100 ppm analyte spike range. This study demonstrates the sensitivity and selectivity of the tile-based F-ratio software for discovery of true positives in the non-targeted analysis of a chemically complex and analytically challenging sample matrix. By exploring the low concentration spike levels, we gain a better understanding of the limit of detection (LOD) of the tile-based F-ratio software with GC × GC – TOFMS data.

Parsons, Brendon A.↗

Delamination-informed lifecycle decisions: A dielectric and machine learning framework for composite sorting and recycling

Composite materials are widely used in aerospace, marine, and automotive sectors due to their high strength-to-weight ratio and durability. However, their long-term reliability can be compromised by damage accumulation. Specifically, delamination initiation serves as a precursor to structural failure, which is often difficult to detect during damage inspection. Identifying and sorting delamination initiation in samples not only increases operational safety while providing critical information for end-of-life decisions, which influences both the service life extension value and the efficiency of fiber extraction during recycling. This research addresses two challenges: (1) developing a nondestructive, ex-situ framework to sort composite materials based on damage severity, particularly delamination, and (2) understanding how damage in composites influences resin removal during pyrolysis. Both experimental work and finite element analysis were performed to predict critical stress levels that are associated with delamination onset. Based on these results, three loading levels 50 %, 75 %, and 90 % of maximum stress, were selected for controlled experiments, generating composite samples with varying extents of damage for machine learning model training. Microscopic imaging of these samples confirmed the damage progression from matrix cracking to delamination, validating the computational predictions. We explored supervised machine learning using dielectric measurements to classify damage states. Preliminary results show an artificial neural network can identify early delamination which is a potential precursor to failure, with 94.44 % accuracy on our dataset. A parallel investigation into the effect of damage severity on pyrolysis recycling showed that heavily delaminated samples required significantly less energy for comparable matrix removal than undamaged samples.

dielectric variables↗

Combined Falling Drop/Open Port Sampling Interface System for Automated Flow Injection Mass Spectrometry

The aim of this work was to demonstrate and to evaluate the analytical performance of a combined falling drop/open port sampling interface (OPSI) system as a simple noncontact, no-carryover, automated system for flow injection analysis with mass spectrometry. The falling sample drops were introduced into the OPSI using a widely available autosampler platform utilizing low cost disposable pipet tips and conventional disposable microtiter well plates. The volume of the drops that fell onto the OPSI was in the 7–15 μL range with an injected sample volume of several hundred nanoliters. Sample drop height, positioning of the internal capillary on the sampling end of the probe, and carrier solvent flow rate were optimized for maximum signal. Sample throughput, signal reproducibility, matrix effects, and quantitative analysis capability of the system were established using the drug molecule propranolol and its isotope labeled internal standard in water, unprocessed river water and two commercially available buffer matrices. A sample-to-sample throughput of ~45 s with a ~4.5 s base-to-base flow injection peak profile was obtained in these experiments. In addition, quantitation with minimally processed rat plasma samples was demonstrated with three different statin drugs (atorvastatin, rosuvastatin, and fluvastatin). Direct characterization capability of unprocessed samples was demonstrated by the analysis of neat vegetable oils. Employing the autosampler system for spatially resolved liquid extraction surface sampling exemplified by the analysis of propranolol and its hydroxypropranolol glucuronide phase II metabolites from a rat thin tissue section was also illustrated.

47 OTHER INSTRUMENTATION↗

An Efficient Multicore Implementation of a Novel HSS-Structured Multifrontal Solver Using Randomized Sampling

Here, we present a sparse linear system solver that is based on a multifrontal variant of Gaussian elimination and exploits low-rank approximation of the resulting dense frontal matrices. We use hierarchically semiseparable (HSS) matrices, which have low-rank off-diagonal blocks, to approximate the frontal matrices. For HSS matrix construction, a randomized sampling algorithm is used together with interpolative decompositions. The combination of the randomized compression with a fast ULV HSS factoriz ation leads to a solver with lower computational complexity than the standard multifrontal method for many applications, resulting in speedups up to 7 fold for problems in our test suite. The implementation targets many-core systems by using task parallelism with dynamic runtime scheduling. Numerical experiments show performance improvements over state-of-the-art sparse direct solvers. The implementation achieves high performance and good scalability on a range of modern shared memory parallel systems, including the Intel Xeon Phi (MIC). The code is part of a software package called STRUMPACK - STRUctured Matrices PACKage, which also has a distributed memory component for dense rank-structured matrices.

97 MATHEMATICS AND COMPUTING↗

High Thermoelectric Performance in Polycrystalline SnSe Via Dual-Doping with Ag/Na and Nanostructuring With Ag 8 SnSe 6

Single crystalline SnSe is one of the most intriguing new thermoelectric materials but the thermoelectric performance of polycrystalline SnSe seems to lag significantly compared to that of a single crystal. Here an effective strategy for enhancing the thermoelectric performance of p-type polycrystalline SnSe by Ag/Na dual-doping and Ag 8 SnSe 6 (STSe) nanoprecipitates is reported. The Ag/Na dual-doping leads to a two orders of magnitude increase in carrier concentration and a convergence of valence bands (VBM1 and VBM5), which in turn results in sharp enhancement of electrical conductivities and high Seebeck coefficients in the Ag/Na dual-doped samples. Additionally, the SnSe matrix becomes nanostructured with dispersed nanoprecipitates of the compound Ag 8 SnSe 6 , which further strengthens the scattering of phonons. Specifically, ≈20% reduction in the already ultralow lattice thermal conductivity is realized for the Sn 0.99 Na 0.01 Se–STSe sample at 773 K compared to the thermal conductivity of pure SnSe. Consequently, a peak thermoelectric figure of merit ZT of 1.33 at 773 K with a high average ZT (ZT ave ) value of 0.91 (423–823 K) is achieved for the Sn 0.99 Na 0.01 Se–STSe sample.

36 MATERIALS SCIENCE↗

Sampling and mass spectrometry approaches for the detection of drugs and foreign contaminants in breath for homeland security applications

Homeland security relies heavily on analytical chemistry to identify suspicious materials and persons. Traditionally this role has focused on attribution, determining the type and origin of an explosive, for example. But as technology advances, analytical chemistry can and will play an important role in the prevention and preemption of terrorist attacks. More sensitive and selective detection techniques can allow suspicious materials and persons to be identified even before a final destructive product is made. The work presented herein focuses on the use of commercial and novel detection techniques for application to the prevention of terrorist activities. Although drugs are not commonly thought of when discussing terrorism, narcoterrorism has become a significant threat in the 21st century. The role of the drug trade in the funding of terrorist groups is prevalent; thus, reducing the trafficking of illegal drugs can play a role in the prevention of terrorism by cutting off much needed funding. To do so, sensitive, specific, and robust analytical equipment is needed to quickly identify a suspected drug sample no matter what matrix it is in. Single Particle Aerosol Mass Spectrometry (SPAMS) is a novel technique that has previously been applied to biological and chemical detection. The current work applies SPAMS to drug analysis, identifying the active ingredients in single component, multi-component, and multi-tablet drug samples in a relatively non-destructive manner. In order to do so, a sampling apparatus was created to allow particle generation from drug tablets with on-line introduction to the SPAMS instrument. Rules trees were developed to automate the identification of drug samples on a single particle basis. A novel analytical scheme was also developed to identify suspect individuals based on chemical signatures in human breath. Human breath was sampled using an RTube{trademark} and the trace volatile organic compounds (VOCs) were preconcentrated using solid phase microextraction (SPME) and identified using gas chromatography - mass spectrometry (GC-MS). Modifications to the sampling apparatus allowed for increased VOC collection efficiency, and reduced the time of sampling and analysis by over 25%. The VOCs are present in breath due to either endogenous production, or exposure to an external source through absorption, inhalation, or ingestion. Detection of these exogenous chemicals can provide information on the prior location and activities of the subject. Breath samples collected before and after exposure in a hardware store and nail salon were analyzed to investigate the prior location of a subject; breath samples collected before and after oral exposure to terpenes and terpenoid compounds, pseudoephedrine, and inhalation exposure to hexamine and other explosive related compounds were analyzed to investigate the prior activity of a subject. The elimination of such compounds from the body was also monitored. In application, this technique may provide an early warning system to identify persons of interest in the prevention and preemption stages of homeland security.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Rapid Sequential Separation Method for Determination of Actinides and TENORM in Fracking Wastes - 20223

With recent advances in unconventional drilling technology in the US and around the world, the risks of environmental contamination and exposure due to technologically enhanced naturally occurring radioactive materials (TENORM) from fracking wastes have also surfaced. Although the Permian Basin (southeastern New Mexico, western Texas) has long been a modest producer of oil, the advent of fracking technology a decade ago turned it into hot property for producers. A 2018 assessment of undiscovered, technically recoverable continuous oil and gas resources by the U.S. Geological Survey estimates an average 46.3 billion barrels of oil and 281 trillion cubic feet of gas. This is likely to increase the use of unconventional drilling and TENORM generation. TENORM concentrations in oil and gas exploration and production waste can be several hundred to several thousand times higher than background TENORM concentrations. Both the thorium and uranium decay chains contribute to airborne radionuclides arising from the radon gas escaping the ground and subsequently decaying as airborne particulates. Additionally, radon decay products {sup 210}Pb and {sup 210}Po can build up in scale on the internal surfaces of oil and gas handling pipes and in sludge in refineries, becoming potential inhalation and ingestion hazards for workers. Furthermore, southeastern NM is also home to world's only licensed and operating transuranic nuclear waste repository, the DoE's Waste Isolation Pilot Plant (WIPP). Plutonium isotopes ({sup 239+240}Pu) and {sup 241}Am, are expected to account for more than 99% of the total radioactivity scheduled for disposal in the WIPP repository. Thus, an improved understanding of the environmental fate and transport of TENORM, liberated by unconventional drilling, is essential to assess how best to protect individuals and the environment. In this context, accurate measurement of TENORM and actinides in environmental and biological samples is essential. In this presentation, a new sequential method for the separation and pre-concentration of actinides (Pu, Am, Np) and TENORM (Po, U and Th) derived from oil and gas exploration is proposed. The TEVA method involves a rapid co-precipitation step to remove matrix interferences from the samples, followed by plutonium oxidation state adjustment to Pu (IV) and an incubation period of ∼ 1 hour at 50-60 deg. C to allow the resultant Po (II) to oxidize into Po(IV). The polonium, neptunium, thorium and plutonium are then separated on a TEVA column, while americium and uranium are separated on a TRU column. After separation, the alpha counting source was prepared by micro-precipitation with copper sulfide (CuS) for polonium and neodymium fluoride (NdF{sub 3}) for actinides. The efficiency and reliability of the procedures were tested by analyzing filter, drinking water and frack sand samples. The method is simple, robust and can be performed quickly with excellent removal of interferences, high chemical recovery and very good alpha peak resolution. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Soluble and Particulate Mercury Deployment of Analytical Method for the Savannah River Site Liquid Waste System

Savannah River National Laboratory (SRNL) developed, tested, and deployed in a radiological containment unit (CU) an analytical method for quantifying particulate total mercury and soluble total mercury in radioactive samples such as the those generated by the dilution of Savannah River Site (SRS) High-Level Waste. This method relies on direct mercury analysis and other associated capabilities for matrix independent quantification of total mercury in solids or liquids (i.e., any sample that can be introduced into the instrument oven for pyrolysis to release all mercury for measurement). The matrix independence allows for discreet measurements of the starting sample, the collected particulates and the filtrate liquid, thus enabling a mass balance quality check. For example, an analysis of a diluted sample from the SRS liquid waste system (LWS) resulted in a measured total mercury value of 55.0 mg Hg/L and a nearly matching calculated total mercury value of 55.1 mg Hg/L (± 20% 2σ) from the summation of measured soluble mercury (47.8 mg Hg/L ± 20% 2σ) and measured particulate mercury (7.26 mg Hg/L ± 20% 2σ). The advantages of the particulate-soluble mercury analysis method are: waste minimization using small radioactive liquid volumes, minimal radiological sample processing and reduced handling steps protective of workers (ALARA) and improved data quality, syringe filter technology which eliminates vacuum filtration and the potential loss of volatile species, small diameter filters (13 mm nominal to 25 mm if needed to avoid clogging) and small disposable poly filter holders (no need to clean) which minimize waste, flexibility provided for a range of starting concentrations, particulate-soluble ratios, and sample matrix conditions, soluble and particulate are measured results that, when summed, and are in good agreement with the total mercury measurement.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Data Report: High-Resolution Microscopy Images of Sediments from Green Canyon Block 955, Gulf of Mexico

We took Leica microscopy images of sediment samples acquired at Holes H002 (4 samples) and H005 (1 sample) during the UT-GOM2-1 Expedition in Green Canyon Block 955, in the northern Gulf of Mexico. A total of 37 images were acquired. The images document a prevalence of spherical conchoidal minerals, cleavage planes typical of feldspar or mica, and black fragmented minerals which stand out from the surrounding matrix. Drilling mud intrusion is thought to contribute to a grey metallic matrix observed across multiple samples.

03 NATURAL GAS↗

Size dependence of microstructure of AlSi10Mg alloy fabricated by selective laser melting

Highlights: • Plate-shaped samples with various widths were fabricated via selective laser melting. • The hardness of AlSi10Mg samples slightly decreased with decreasing sample width. • The alloy sample size had a slight effect on microstructure of the α-Al matrix. • Precipitation of Si phase in α-Al matrix was enhanced by reducing the sample size. • The softening by reducing sample size is likely due to their slower cooling rate. - Abstract: In order to investigate the size dependence of microstructure of the AlSi10Mg alloy fabricated by selective laser melting (SLM) combined with a powder bed technique, plate-shaped AlSi10Mg alloy samples with various widths (ranging from approximately 10 mm to 0.3 mm) were produced in this study. All the fabricated samples exhibited characteristic microstructural morphologies consisting of melt pools with columnar α-Al grains surrounded by fine eutectic Si particles, whereas their sample sizes had a relatively small effect on the texture and average grain size of the α-Al matrix. However, the formation of fine Si precipitates inside the columnar α-Al grains was observed more often for the smaller-sized samples, which could be a possible dominant contributor to the observed softening of the sample by reducing sample size. The obtained results were utilized for discussing the size dependence of the strength of the SLM-manufactured porous alloy samples.

36 MATERIALS SCIENCE↗