Search NASA⌕ Search

SEARCH · Search NASA

Results for “mechanical devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Comparison of the US and Russian Cycle Ergometers

The purpose of this study was to compare the U.S. and Russian cycle ergometers focusing on the mechanical differences of the devices and the physiological differences observed while using the devices. Methods: First, the mechanical loads provided by the U.S. Cycle Ergometer with Vibration Isolation System (CEVIS) and the Russian Veloergometer were measured using a calibration dynamometer. Results were compared and conversion equations were modeled to determine the actual load provided by each device. Second, ten male subjects (32.9 +/- 6.5 yrs, 180.6 +/- 4.4 cm; 81.9 +/- 6.9 kg) experienced with both cycling and exercise testing completed a standardized submaximal exercise test protocol on CEVIS and Veloergometer. The exercise protocol involved 8 sub-maximal workloads each lasting 3 minutes for a total of 24 minutes per session, or until the end of the stage when the subject reached 85% of peak oxygen consumption or age-predicted maximum heart rate (220 - age). The workload started at 50 Watts (W), increased to 100 W, and then increased 25 W every 3 minutes until reaching a peak workload of 250 W. Physiological variables were then compared at each workload by repeated measures ANOVA or paired t-tests (p<0.05). Results: While both CEVIS and Veloergometer produced significantly lower workloads than the displayed workload, CEVIS produced even lower loads than Veloergometer (p<0.05) at each indicated workload. Despite this fact, the only physiological variables that showed a significant difference between the ergometers were VE (125 - 250W), VO2 (175 and 250 W), and VCO2 (175 W). All other physiological data were not statistically different between CEVIS and Veloergometer. Conclusion: Although workloads were different between ergometers, relatively few physiological differences were observed. Therefore, CEVIS workloads of 87.5 - 262.5 W can be rounded to the nearest 25 W increment and performed on the Veloergometer.

Norcross, Jason↗

Fundamental problems of injector design

The principal control of the combustion within a liquid-propellant rocket thrust chamber is provided by the injector. Only when precise control of the injection process is attained can optimum performance, dynamic stability, heat transfer compatibility and reproducibility be provided. Control must be designed into each step of the injection process with sufficient isolation provided to insure stability. In the design of the injector manifolding, the main desire is to provide mass and mixture ratio regulation across the injector face. The design of the injector orifices must be such that this mass and mixture ratio control is retained through the orifices and imparted to the droplet sprays that are produced. Furthermore, the orifice design must control the size and distribution of the droplets generated so that combustion will be completed within the chamber. Mechanical damping devices are often required to protect the early mixing zone from transverse velocities and associated displacement effects in the chamber. Only when each phase of the injection process is carefully controlled can the design aims be reached.

David T Harrje↗

Properties of hollow square gravitational wave detectors

Antennas are described with gravitational radiation properties such as polarization, directivity, and scalar and tensor characteristics. These antenna devices are mechanically resonant systems in the shape of a hollow square with fundamental frequencies in the Hz range. An antenna characteristic is that the absorption cross section for quadrupole radiation at the normal frequency of vibration is the same as that of the fundamental if the damping factors are the same. The absorption cross section of quadrupole gravitational radiation is calculated for a class-1 detector of a cylindrical cross section and for a class-2 detector shaped like a hollow square.

Douglass, D. H., Jr.↗

Design and evaluation of controls for drift, video gain, and color balance in spaceborne facsimile cameras

The facsimile camera is an optical-mechanical scanning device which has become an attractive candidate as an imaging system for planetary landers and rovers. This paper presents electronic techniques which permit the acquisition and reconstruction of high quality images with this device, even under varying lighting conditions. These techniques include a control for low frequency noise and drift, an automatic gain control, a pulse-duration light modulation scheme, and a relative spectral gain control. Taken together, these techniques allow the reconstruction of radiometrically accurate and properly balanced color images from facsimile camera video data. These techniques have been incorporated into a facsimile camera and reproduction system, and experimental results are presented for each technique and for the complete system.

Katzberg, S. J.↗

Design and evaluation of a filter spectrometer concept for facsimile cameras

The facsimile camera is an optical-mechanical scanning device which was selected as the imaging system for the Viking '75 lander missions to Mars. A concept which uses an interference filter-photosensor array to integrate a spectrometric capability with the basic imagery function of this camera was proposed for possible application to future missions. This paper is concerned with the design and evaluation of critical electronic circuits and components that are required to implement this concept. The feasibility of obtaining spectroradiometric data is demonstrated, and the performance of a laboratory model is described in terms of spectral range, angular and spectral resolution, and noise-equivalent radiance.

Kelly, W. L., IV↗

The facsimile camera - Its potential as a planetary lander imaging system

The facsimile camera is an optical-mechanical scanning device which is an attractive candidate for planetary lander imaging systems and has been selected for the Viking/Mars mission because of its light weight, small size, and low power requirement. Other advantages are that it can provide good radiometric and photogrammetric accuracy because the complete field of view is scanned with a single photodetector located on or near the optical axis of the objective lens. In addition, this device has the potential capability of multispectral imaging and spectrometric measurements.

Huck, F. O.↗

Position sensing materials wound on a reel

Electro-optical counter measures number of layers of web wound on reel and indicates layer number and web position digitally, without physically contacting reel or requiring numerical interpolation from mechanical readout device.

Muller, R. M.↗

Rotating optical coupler for signal transmission

Optical coupler using Dove prism assembly to form stationary image of rotating object, transmits data across rotating interface without sliprings or other mechanical contacts. Device can handle many high-bit-rate data channels.

Ivie, C. V.↗

MIDAS prototype Multispectral Interactive Digital Analysis System for large area earth resources surveys. Volume 2: Charge coupled device investigation

MIDAS is a third-generation, fast, low cost, multispectral recognition system able to keep pace with the large quantity and high rates of data acquisition from large regions with present and projected sensors. MIDAS, for example, can process a complete ERTS frame in forty seconds and provide a color map of sixteen constituent categories in a few minutes. A principal objective of the MIDAS Program is to provide a system well interfaced with the human operator and thus to obtain large overall reductions in turn-around time and significant gains in throughput. The need for advanced onboard spacecraft processing of remotely sensed data is stated and approaches to this problem are described which are feasible through the use of charge coupled devices. Tentative mechanizations for the required processing operations are given in large block form. These initial designs can serve as a guide to circuit/system designers.

Kriegler, F.↗

Dynamics and control simulation of the Spacelab Experiment Pointing Mount

Computer simulations were developed to evaluate the performance of four Experiment Pointing Mounts (EPM) being considered for Spacelab experiments in the 1980-1990 time frame. The system modeled compromises a multibody system consisting of the shuttle, a mechanical isolation device, the EPM, celestial and inertial sensors, bearings, gimbal torque motors and associated nonlinearities, the experiment payload, and control and estimator algorithms. Each mount was subjected to a common disturbance (shuttle vernier thruster firing and man push off) and command (stellar pointing or solar raster scan) input. The fundamental limitation common to all mounts was found to be sensor noise. System dynamics and hardware nonlinearities have secondary effects on pointing performance for sufficiently high bandwidth.

Marsh, E. L.↗

Two (or more) rotary outputs from one input

Mechanical sequencing device produces cyclic rotations of two outputs from single cyclic rotary input. Device is useful in automatic assemble apparatus, in food-processing machinery, and as controller for sequentially operated valves.

Appleberry, W. T.↗

Image dissector photocathode solar damage test program

Image dissector sensors of the same type which will be used in the NASA shuttle star tracker were used in a series of tests directed towards obtaining solar radiation/time damage criteria. Data were evaluated to determine the predicted level of operability of the star tracker if tube damage became a reality. During the test series a technique for reducing the solar damage effect was conceived and verified. The damage concepts are outlined and the test methods and data obtained which were used for verification of the technique's feasibility are presented. The ability to operate an image dissector sensor with the solar image focussed on the photocathode by a fast optical lens under certain conditions is feasible and the elimination of a mechanical protection device is possible.

Smith, R. A.↗

Development of a ferromagnetic rotary vacuum sealed spacecraft spin fixture

A number of successful spacecraft tests were conducted on an environmental spin fixture which utilizes a ferrofluidic rotary vacuum seal. The 27 cm (10.5 inch) diameter fixture drive shaft supports and spins communications satellites during flight acceptance testing in a thermal vacuum chamber. The drive shaft rotary seal serves to maintain the canned drive system electro-mechanical components at ambient pressure within the space simulator. The ferromagnetic fluid seal was chosen over conventional mechanical sealing devices for its zero-leakage, zero-wear, and minimum friction drag characteristics, as well as its high reliability potential.

Levine, M. B.↗

New Alloy for Glass-to-Metal Seals

Coefficient of thermal expansion approximates that of glass more closely. Alloy composed of about 60 percent iron, 40 percent nickel, and traces of six other elements. Developed as replacement for Kovar Fe/Ni/Co alloy in ferrule-and-tube assembly, new alloy has same strength, solderability, and compatibility with fuel as does Kovar. Used in glass-to-metal seals without excessive residual stresses. Potential for other applications in which low thermal expansion important; mechanical measuring devices and precise sliding parts that must function over wide temperature ranges.

Schmuck, A. J.↗

Feasibility study for convertible engine torque converter

The feasibility study has shown that a dump/fill type torque converter has excellent potential for the convertible fan/shaft engine. The torque converter space requirement permits internal housing within the normal flow path of a turbofan engine at acceptable engine weight. The unit permits operating the engine in the turboshaft mode by decoupling the fan. To convert to turbofan mode, the torque converter overdrive capability bring the fan speed up to the power turbine speed to permit engagement of a mechanical lockup device when the shaft speed are synchronized. The conversion to turbofan mode can be made without drop of power turbine speed in less than 10 sec. Total thrust delivered to the aircraft by the proprotor, fan, and engine during tansient can be controlled to prevent loss of air speed or altitude. Heat rejection to the oil is low, and additional oil cooling capacity is not required. The turbofan engine aerodynamic design is basically uncompromised by convertibility and allows proper fan design for quiet and efficient cruise operation. Although the results of the feasibility study are exceedingly encouraging, it must be noted that they are based on extrapolation of limited existing data on torque converters. A component test program with three trial torque converter designs and concurrent computer modeling for fluid flow, stress, and dynamics, updated with test results from each unit, is recommended.

Source record↗

OH radical measurements by optical absorption spectroscopy

The long path absorption spectroscopy (LPA) measurement of OH utilizes the strong UV absorption spectrum of the molecule with well resolved rotational lines around 308 nm. The light source consists of an Ar ion laser pumped CW dye laser, the output of which is frequency doubled to emit a spectrally smooth light profile of 0.1 nm FWHM at 308 nm. This is considerably broader than the sharp (0.0018 nm wide) absorption features of OH and also wider than the total spectral region (0.06 nm) scanned around the OH lines. For field measurements a Cassegrain-type telescope expands the small diameter of the original laser beam by a factor of 50 to about a 0.25-m diameter in order to reduce the divergence of the beam as well as its mean photon flux density, thus reducing the maximum self-generated OH concentration to 40,000 cu. cm. The light is passed into the open atmosphere and reflected at about 5 km distance resulting in a 10-km light path length. A telescope focuses the returning light onto the entrance slit of a monochromator the single exit slit of which is replaced by a mechanical scanning device operating at a scan repetition rate of 6.6 KHz. For a typical measurement (1h duration) some 20,000,000 scans are averaged, rendering the contribution of atmospheric turbulence to the spectral noise negligible.

Platt, U.↗