Search NASA⌕ Search

SEARCH · Search NASA

Results for “metrology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Safety Compliance Verification of Fuel Cell Electric Vehicle Exhaust

NREL has been developing compliance verification tools for allowable hydrogen levels prescribed by the Global Technical Regulation Number 13 (GTR-13) for hydrogen fuel cell electric vehicles (FCEVs). As per GTR-13, FCEV exhaust is to remain below 4 vol% H2 over a 3-second moving average and shall not at any time exceed 8 vol% H2 and that this requirement is to be verified with an analyzer that has a response time of less than 300 ms. To be enforceable, a means to verify regulatory requirements must exist. In response to this need, NREL developed a prototype analyzer that meets the GTR metrological requirements for FCEV exhaust analysis. The analyzer was tested on a commercial fuel cell electric vehicle (FCEV) under simulated driving conditions using a chassis dynamometer at the Emissions Research and Measurement Section of Environment and Climate Change Canada and FCEV exhaust was successfully profiled. Although the prototype FCEV Exhaust Analyzer met the metrological requirements of GTR-13, the stability of the hydrogen sensor was adversely impacted by condensed water in the sample gas. FCEV exhaust is at an elevated temperature and nearly saturated with water vapor. Furthermore, condensed water is present in the form of droplets. Condensed water in the sample gas can collect on the hydrogen sensing element, which would not only block access of hydrogen to the sensor but can also permanently damage the sensor. In the past year, the design of the gas sampling system was modified to mitigate against the transport of liquid water to the sensing element. Laboratory testing confirmed the effectiveness of the modified sampling system water removal strategy while maintaining the measurement range and response time required by GTR-13. Testing of the upgraded analyzer design on an FCEV operating on a chassis dynamometer is scheduled for the summer of 2021.

DIRECT ENERGY CONVERSION,HYDROGEN↗

Hard disk drive dismantlement for critical material recovery

A system and method for recycling rare earth materials from dissimilar hard disk drives are provided. The system and method generally include scanning each hard disk drive, sorting and aligning each hard disk drive, rapid fastener removal or diversion to a metrology station, and the collection of separated value streams, optionally for formation into new magnetic stock. For each scanned hard disk drive having a match in an inventory database, the method includes the separation of an internal magnet from residual components. For each scanned hard disk drive lacking a match in the inventory database, the method includes generating a metrology data collection record containing the location of each fastener on multiple surfaces of the corresponding hard disk drive. The system and method are commercially scalable with the potential to generate between 600 and 700 metric tons of rare earth elements from a single processing facility annually, including neodymium for example.

McIntyre, Timothy J.↗

Godiva IV Central Cavity Neutron Environment Characterization with Threshold Neutron Detectors

Godiva IV is a cylindrical fast burst reactor comprised of approximately 65 kg of highly enriched uranium that is operated by Los Alamos National Laboratory and sited at the National Criticality Experiments Research Center at the Nevada National Security Site in Nevada in the United States. Godiva IV is typically operated at delayed critical and in the regime spanning from sub-prompt to super-prompt bursts. Godiva IV is used for sample irradiations, criticality safety demonstrations, dosimetry studies, and for studying super-prompt behavior. In preparation for both an upcoming experiment to reduce uncertainties in the prompt fission spectrum for 235 U using threshold neutron detectors, and for future research using Godiva IV, it was desired to exercise the process of the selection of threshold neutron detectors/activation foils, radiation metrology, and the subsequent adjustment of the neutron spectrum. For this exercise, nine high purity threshold neutron detectors/activation foils were irradiated in a Godiva IV burst. The foils were then analyzed using a high purity germanium detector in the NCERC counting laboratory to determine end of irradiation specific activities for available IRDFF-II reactions. This work summarizes the Godiva IV foil irradiation, radiation metrology results, and adjusted neutron spectrum. The results of this exercise ultimately characterized the neutron environment inside the sample irradiation cavity inside Godiva IV to a higher degree than previously performed, informed decisions for the upcoming larger scale experiment, and will inform future neutron spectrum characterizations at NCERC.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A 3D-Printed Millimeter-Wave Inline Waveguide-to-Coplanar-Waveguide Transition to Enable Dense Spectrometer Arrays for Intensity Mapping Surveys

We present a 3D-printed millimeter-wave, octave-bandwidth, in-line waveguide-to-coplanar-waveguide transition designed to enable focal planes with dense arrays of on-chip spectrometers. These arrays will enable compelling surveys of the large-scale structure of the universe through millimeter-wave intensity mapping. The transition consists of a four-step ridge-waveguide transformer that couples light from a rectangular waveguide onto a coplanar waveguide via an electrical connection made with indium bump bonds. We develop a tolerance-aware optimization approach to identify high-performance transition geometries that are robust to manufacturing variations; the same formulation can be applied to other tolerance-sensitive design problems. We also describe the implementation of a custom apparatus and procedure for bump-bonding a silicon chip to a metallized 3D-printed component. We detail the fabrication of the coplanar waveguide chip and three-dimensional waveguide structure, simulations and metrology of a test device, and room temperature reflectance measurements of this device. The room temperature metrology and reflection measurements are consistent with a model that predicts a coupling efficiency of $\mathord{\sim} 95\%$ at cryogenic temperatures in the 85-170 GHz frequency range.

Stover, Austin [Chicago U.; Chicago U., KICP] (ORC↗

Comparison of theory with the experimental characterization of the spatial frequency response of interferometers using a binary pseudo-random array sample

Experimental evaluations of the surface height response of an interference microscope using a binary pseudo-random array test sample are compared with a theory based on a Fourier optics model. Measurements of key instrument characteristics, including the illumination, imaging, and obscuring apertures of three different Mirau objectives, support the theoretical calculations. Agreement between experimental and theoretical modeling confirms the predictability of the spatial frequency response for the purpose of specification and optimization of instrument configuration for specific metrology tasks. The results also provide confidence in methods of compensating for the decrease in instrument response with spatial frequency.

Calibration↗

Thermoreflectance Detection of Point Defects Resulting from Focused Ion Beam Milling

Focused ion beam (FIB) milling is a commonly used tool for nanoscale material processing, such as for transmission electron microscopy (TEM) sample preparation, or the creation of fiducial markers prior to other processes and measurements. During milling, a high energy ion beam is used to remove material via sputtering. The expelled target material may return to the sample surface however, affecting subsequent measurements. Beam spreading or irradiation due to neutral gallium may also irradiate a larger area than intended. Extensive research has explored the effects of FIB milling on the prepared TEM sample, but few have looked at the effects of milling on the properties of the sample surrounding the milled region. We use multiple pump-probe laser-based techniques (time domain thermoreflectance and steady-state thermoreflectance) to measure the spatial extent of FIB-induced surface/subsurface changes on a series of silicon wafers milled at multiple currents and doses. We supplement these measurements with high-resolution scanning transmission electron microscopy, energy dispersive X-ray spectroscopy, stylus profilometry, and time-of-flight secondary ion mass spectroscopy. We find a sample surface affected by the FIB up to 1 mm from where milling occurred, with a notable dependence on the ion beam current. We also note remarkably high sensitivity to surface defects using the thermoreflectance metrologies, including detection where other measurements failed.

defects↗

Engineering Perovskite Precursor Inks for Scalable Production of High‐Efficiency Perovskite Photovoltaic Modules

Abstract Blade coating of perovskite solar cells (PSCs) and modules has progressed considerably toward the industrial production of perovskite photovoltaics. Developing stable perovskite precursors is critical for achieving uniform coating over large areas. Here, the engineering of a perovskite precursor solution consisting of 2‐methoxyethanol (2‐Me) and 1,3‐dimethyl‐imidazolidinone (DMI) with superior intermediate phase stability that enables scalable production of efficient perovskite solar modules is reported. With this perovskite precursor solution, uniform and pinhole‐less perovskite film is deposited over a large area of > 100 cm 2 and higher‐efficiency PSCs and modules are obtained. The best‐performing unit cell and module with n‐i‐p configuration reach power conversion efficiencies of 23.4% and 20.1%, respectively. Additionally, a series of non‐destructive metrology methods, such as spectroscopic ellipsometry, hyperspectral photoluminescence, electroluminescence, and laser beam‐induced current mapping, are employed to assess and guide the development the blade‐coated perovskite modules. This results show that rational engineering of precursor inks for blade coating is promising for the scalable production of efficient perovskite solar modules.

36 MATERIALS SCIENCE↗

Innovative approaches to neutron beam optimization: A case study of FP14 at LANSCE

This paper describes an experimental method to acquire high resolution energy- and spatially- resolved neutron beam spots using the time-gated neutron imaging system with Teledyne Pi-MAX4 camera. These experimental data offer a unique opportunity for benchmarking beam spot simulations. High-quality simulations depend significantly on a high-fidelity geometry model, which can be challenging for legacy facilities. We informed our MCNPX geometry model by latest metrology survey employing Leica laser tracker ATS600. It gave us a high fidelity description of our facility geometry. Such a robust integration of novel tools and methods yields a previously unattainable level of accuracy in both predicting and capturing neutron beam spots, marking a notable advancement over traditional methods reliant on static image plates. Here, to demonstrate the practical application of these tools, we are showing a non-uniform beam spot challenge at our Flight Path 14 (FP14) at the Los Alamos Neutron Science Center (LANSCE). Our precise MCNPX prediction of beam spot shifting as function of neutron energy was confirmed by experimental beam spot measured with extremely high level of detail. Results of this research demonstrate a significant leap in neutron beam optimization at LANSCE and set a new benchmark in beam spot characterization. The advanced methods presented here have potential for adoption at similar research facilities worldwide, aiming at substantial improvement in neutron beam delivery for experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact instantaneous phase-shifting Sagnac interferometer for nanoscale tilt measurement

There is a large inter disciplinary need for high precision angular sensors in state-of-the-art technologies. This particularly applies to optical metrology in the field of Extreme Ultraviolet (EUV) or X-ray where the optics are commonly characterized in terms of slope errors at a nanoradian scale level. Here, in this paper, we present the in-lab development of an angular sensor based on a single reflection compact Sagnac interferometer using instantaneous phase shifting. Our automated prototype and first results show less than 15 nrad RMS repeatability, at least 200 nrad sensitivity and 280 nrad reproducibility over 100 μrad angular range.

36 MATERIALS SCIENCE↗

Parallel Quantum-Enhanced Sensing

Quantum metrology takes advantage of quantum correlations to enhance the sensitivity of sensors and measurement techniques beyond their fundamental classical limit, given by the shot-noise limit. The use of both temporal and spatial correlations present in quantum states of light can extend quantum-enhanced sensing to a parallel configuration that can simultaneously probe an array of sensors or independently measure multiple parameters. To this end, we use multispatial-mode bright twin beams of light, which are characterized by independent quantum-correlated spatial subregions in addition to quantum temporal correlations, to probe a four-sensor quadrant plasmonic array. We show that it is possible to independently and simultaneously measure local changes in refractive index for all four sensors with a quantum enhancement in sensitivity in the range of 22% to 24% over the corresponding classical configuration. Finally, these results provide a first step toward highly parallel spatially resolved quantum-enhanced sensing techniques and pave the way toward more complex quantum sensing and quantum imaging platforms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantum interference of currents in an atomtronic SQUID

Quantum interference of currents is the most important and well known quantum phenomenon in a conventional superconducting quantum interference device (SQUID). Here, we report the observation of quantum interference of currents in an atomtronic SQUID. Analogous to a conventional SQUID, currents flowing through two junctions in an atomtronic SQUID interfere due to the phase difference from rotation. This interference results in modulation of critical currents. This modulation was observed for three different radii with clear modulation periods which were measured to be consistent with fundamental rotation rates. This observation shows the possibility of studying various interesting SQUID physics with an atomtronic SQUID and especially, macroscopic quantum phenomena with currents may be realized with an atomtronic SQUID toward the goal of quantum metrology of rotation sensing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A hybrid coupler for directing quantum light emission with high radiative Purcell enhancement to a dielectric metasurface lens

Quantum photonic technologies such as quantum sensing, metrology, and simulation could be transformatively enabled by the availability of integrated single photon sources with high radiative rates and photon collection efficiencies. We address these challenges for quantum emitters formed from color center defect sites such as those in hexagonal boron nitride, which are promising candidates as single photon sources due to their bright, stable, polarized, and room temperature emission. We report design of a nanophotonic coupler from color center quantum emitters to a dielectric metasurface lens. The coupler is comprised of a hybrid plasmonic–dielectric resonator that achieves a large radiative Purcell enhancement and partial control of far-field radiation. We report radiative Purcell factors up to 285 and photon collection efficiencies up to 89% for a lossless metasurface, applying a continuous hyperboloidal phase-front. Our hybrid plasmonic–dielectric coupler interfacing two nanophotonic elements is a compound optical element, analogous to those found in microscope objective lenses, which combine multiple optical functions into a single component for improved performance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

3ω techniques for measurement of volumetric heat capacity and anisotropic thermal conductivity of a solution processable, hybrid organic/inorganic film, Te-PEDOT:PSS

We report that measuring the thermal properties of anisotropic films of hybrid materials poses a challenge to existing metrology techniques. We have developed a new approach for measuring the volumetric heat capacity and anisotropic thermal conductivity of these systems using the 3ω method. While there exist many avenues for measuring the thermal properties of thin films, most carry with them difficult requirements such as smooth surfaces or advanced lithography. Here, we present measurements of a film's in-plane and cross-plane conductance and its volumetric heat capacity using relatively simple sample configurations, each requiring a single heater. For the measurement of volumetric heat capacity, we present a new model fitting method, relying on a standard film-on-substrate configuration. For the measurement of in-plane thermal conductance by 3ω, we have developed the use of an embedded micro-wire heater in suspended drop cast films, allowing for a 12 μm wide heater without the need for advanced lithography. We also expose the surprisingly significant effect of thermal radiation in the suspended film measurement and its associated error. Our measurements reveal a large anisotropy in the thermal conductivity of our test material, Te-PEDOT:PSS, of k in-plane / k cross-plane = 19, consistent with the nanoscale morphology of the material.

36 MATERIALS SCIENCE↗

Photonic circuits for laser stabilization with integrated ultra-high Q and Brillouin laser resonators

The integration of stabilized lasers, sources that generate spectrally pure light, will provide compact, low-cost solutions for applications including quantum information sciences, precision navigation and timing, metrology, and high-capacity fiber communications. We report a significant advancement in this field, demonstrating stabilization of an integrated waveguide Brillouin laser to an integrated waveguide reference cavity, where both resonators are fabricated using the same CMOS-compatible integration platform. We demonstrate reduction of the free running Brillouin laser linewidth to a 292 Hz integral linewidth and carrier stabilization to a 4.9 × 10 –13 fractional frequency at 8 ms reaching the cavity-intrinsic thermorefractive noise limit for frequencies down to 80 Hz. We achieve this level of performance using a pair of 56.4 x 10 6 quality factor Si 3 N 4 waveguide ring-resonators that reduce the high-frequency noise by the nonlinear Brillouin process and the low-frequency noise by Pound–Drever–Hall locking to the ultra-low loss resonator. These results represent an important step toward integrated stabilized lasers with reduced sensitivity to environmental disturbances for atomic, molecular, and optical physics (AMO), quantum information processing and sensing, and other precision scientific, sensing, and communications applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Near-field imaging of optical resonances in silicon metasurfaces using photoelectron microscopy

Precise control of light–matter interactions at the nanoscale lies at the heart of nanophotonics. However, experimental examination at this length scale is challenging since the corresponding electromagnetic near-field is often confined within volumes below the resolution of conventional optical microscopy. In semiconductor nanophotonics, electromagnetic fields are further restricted within the confines of individual subwavelength resonators, limiting access to critical light–matter interactions in these structures. In this work, we demonstrate that photoelectron emission microscopy (PEEM) can be used for polarization-resolved near-field spectroscopy and imaging of electromagnetic resonances supported by broken-symmetry silicon metasurfaces. We find that the photoemission results, enabled through an in situ potassium surface layer, are consistent with full-wave simulations and far-field reflectance measurements across visible and near-infrared wavelengths. In addition, we uncover a polarization-dependent evolution of collective resonances near the metasurface array edge taking advantage of the far-field excitation and full-field imaging of PEEM. Here, we deduce that coupling between eight resonators or more establishes the collective excitations of this metasurface. All told, we demonstrate that the high-spatial resolution hyperspectral imaging and far-field illumination of PEEM can be leveraged for the metrology of collective, non-local, optical resonances in semiconductor nanophotonic structures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The impact of pulse width modulation on heat accumulation in AlGaN channel HEMTs

The poor thermal properties of Aluminum–Gallium Nitride (AlGaN) channel High Electron Mobility Transistors (HEMTs) on sapphire limit the device’s maximum switching frequency due to high channel temperatures. Extracting the correct thermal time constants can provide guidelines for the device’s safe frequency operation. This study experimentally quantifies the impact of pulse width and duty cycle on the transient thermal dynamics of multi-finger AlGaN channel HEMTs. In most transient thermal metrology, lock-in averaging approaches are leveraged to increase signal-to-noise ratio and measure the device’s relative temperature rise. Assuming no heat accumulation, the temperature rise is used to quantify the device’s thermal resistance under continued pulsed biasing. For devices grown on sapphire substrates, however, heat accumulation leads to elevated reference temperatures and causes the differential measurement to underestimate the peak temperature. This study demonstrates the capability of transient Gate Resistance Thermometry (tGRT) to measure the absolute temperature, which is required to precisely evaluate the device’s thermal resistance. When an absolute temperature measurement is not feasible (such as thermoreflectance imaging), a solution is proposed to derive the peak temperature under pulsed biasing based on the differential temperature under pulsing and the steady-state thermal resistance (which is typically easier to obtain). Finally, additional tGRT (without averaging) is performed to demonstrate the temperature-dependent thermal time constants required to minimize heat accumulation effects.

Field effect transistors↗

Advancing microelectronics through nanoscale science: A perspective on needs and opportunities from the nanoscale science research centers

Microelectronics are the cornerstone of the modern world, enhancing our daily lives by providing services such as communications and datacenters. These resources are accessible thanks to the continual pursuit of a deeper understanding of the chemical and physical phenomena underlying the materials synthesis approaches and fabrication processes used to create microelectronic components and subsequently the components' responses to electrical, optical, and other stimuli that are utilized within microelectronic systems. Today, further development of microelectronics requires multidisciplinary expertise across scientific disciplines and fields of study—synthesis, materials characterization, nanoscale fabrication, and performance characterization—with focus placed on comprehending the nanoscale forms and features of microelectronic components. The Nanoscale Science Research Centers (NSRCs) are Department of Energy, Office of Science user facilities that support the international scientific community in advancing nanoscale science and technology. As a key component of the U.S. Government's National Nanotechnology Initiative, the NSRCs enable transformative discoveries by providing world-class facilities, expertise, and collaborative opportunities. Here, in this perspective, we showcase a non-exhaustive cross-section of the capabilities housed at and developed by the NSRCs and their user communities to address fundamental synthesis, metrology, fabrication, and performance considerations toward advancing the development of new microelectronics. Finally, we provide a timely outlook on the next major areas of necessary development in nanoscale sciences to continue the innovation of microelectronics into the next generation.

2D materials↗

In-plane thermal conductivity and the applicability of the Wiedemann–Franz law in dilute AlCu thin films

The Wiedemann–Franz (WF) law correlates heat and charge transport in metals. However, the validity of this correlation remains an open-ended question, especially in the context of inelastic scattering at room temperature. To address this gap in knowledge, we perform independent measurements of the in-plane thermal and electrical conductivities across four AlCu (0.5% Cu) films [thickness (⁠h⁠) ≈ 174, 98, 53, and 24 nm] using optical pump–probe metrologies and four-point probe techniques, respectively. For in-plane thermal conductivity measurements, we utilize time-domain thermoreflectance, in both concentric and beam-offset configurations, and the time-resolved magneto-optic Kerr effect. Our results show that the WF law overpredicts the thermal conductivity by at least ∼10% in all films, thus demonstrating modest deviations in predicted thermal conductivity when applying the WF law to dilute AlCu films. Using infrared variable angle spectroscopic ellipsometry, we demonstrate increased electron scattering rates in the thinnest film (⁠⁠h⁠ ≈ 24 nm), indicating electron-boundary scattering drives the reduction in in-plane thermal conductivity. Furthermore, this is generally an elastic scattering process, which is supported by our thermal conductivity measurements and analysis.

Electrical conductivity↗