Search NASA⌕ Search

SEARCH · Search NASA

Results for “motion correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Corrigendum: New Form of Kane's Equations of Motion for Constrained Systems

A correction to the previously published article "New Form of Kane's Equations of Motion for Constrained Systems" is presented. Misuse of the transformation matrix between time rates of change of the generalized coordinates and generalized speeds (sometimes called motion variables) resulted in a false conclusion concerning the symmetry of the generalized inertia matrix. The generalized inertia matrix (sometimes referred to as the mass matrix) is in fact symmetric and usually positive definite when one forms nonminimal Kane's equations for holonomic or simple nonholonomic systems, systems subject to nonlinear nonholonomic constraints, and holonomic or simple nonholonomic systems subject to impulsive constraints according to Refs. 1, 2, and 3, respectively. The mass matrix is of course symmetric when one forms minimal equations for holonomic or simple nonholonomic systems using Kane s method as set forth in Ref. 4.

Roithmayr, Carlos M.↗

SU-G-BRA-09: Estimation of Motion Tracking Uncertainty for Real-Time Adaptive Imaging

Purpose: kV fluoroscopic imaging combined with MV treatment beam imaging has been investigated for intrafractional motion monitoring and correction. It is, however, subject to additional kV imaging dose to normal tissue. To balance tracking accuracy and imaging dose, we previously proposed an adaptive imaging strategy to dynamically decide future imaging type and moments based on motion tracking uncertainty. kV imaging may be used continuously for maximal accuracy or only when the position uncertainty (probability of out of threshold) is high if a preset imaging dose limit is considered. In this work, we propose more accurate methods to estimate tracking uncertainty through analyzing acquired data in real-time. Methods: We simulated motion tracking process based on a previously developed imaging framework (MV + initial seconds of kV imaging) using real-time breathing data from 42 patients. Motion tracking errors for each time point were collected together with the time point’s corresponding features, such as tumor motion speed and 2D tracking error of previous time points, etc. We tested three methods for error uncertainty estimation based on the features: conditional probability distribution, logistic regression modeling, and support vector machine (SVM) classification to detect errors exceeding a threshold. Results: For conditional probability distribution, polynomial regressions on three features (previous tracking error, prediction quality, and cosine of the angle between the trajectory and the treatment beam) showed strong correlation with the variation (uncertainty) of the mean 3D tracking error and its standard deviation: R-square = 0.94 and 0.90, respectively. The logistic regression and SVM classification successfully identified about 95% of tracking errors exceeding 2.5mm threshold. Conclusion: The proposed methods can reliably estimate the motion tracking uncertainty in real-time, which can be used to guide adaptive additional imaging to confirm the tumor is within the margin or initialize motion compensation if it is out of the margin.

60 APPLIED LIFE SCIENCES↗

Transonic Correction Method for Flight Dynamic Stability Analysis of Mach 0.745 Transonic Truss-Braced Wing

This paper presents a transonic correction method for obtaining dynamic stability derivatives for flight dynamic stability analysis. The method provides a transonic correction to the Theodorsen's theory of unsteady aerodynamics using FUN3D CFD solver of unsteady Reynolds-averaged Navier-Stokes equations (RANS) for a series of wing sections of the Mach 0.745 Transonic Truss-Braced Wing in pitch and plunge oscillations. Unsteady lift and pitching moment coefficients are obtained and used to develop the correction terms in the Theodorsen's theory to account for transonic aerodynamics. The unsteady lift and pitching moment derivatives with respect to the unsteady angle of attack are obtained as frequency response functions of the reduced frequency. These frequency response functions are used to compute the dynamic stability derivatives of lift and pitching moment due to the angle of attack and pitch rate and the dynamic stability derivatives for the rolling moment and yawing moment with respect to the roll rate and yaw rate. A transonic correction is applied to steady-state stability derivatives computed by VSPAERO solver using transonic small disturbance code TSFOIL coupled to an integral boundary method. A dynamic stability analysis is conducted for longitudinal and lateral-directional motions. Without transonic corrections and dynamic stability derivatives, the analysis indicates an unstable phugoid mode. The transonic correction applied to the steady-state stability derivatives computed by VSPAERO shows a stable phugoid mode. This is due to the increase of the drag stability derivatives as a result of the additional wave drag contribution in transonic flow. The effect of the transonic dynamic stability derivatives is observed to be a significant contributor to the increase in the damping values of all the flight dynamic modes of the Mach 0.745 Transonic-Truss Braced Wing.

Transonic↗

Beyond the geodesic approximation: Conservative effects of the gravitational self-force in eccentric orbits around a Schwarzschild black hole

We study conservative finite-mass corrections to the motion of a particle in a bound (eccentric) strong-field orbit around a Schwarzschild black hole. We assume the particle's mass {mu} is much smaller than the black hole mass M, and explore post-geodesic corrections of O({mu}/M). Our analysis uses numerical data from a recently developed code that outputs the Lorenz-gauge gravitational self-force (GSF) acting on the particle along the eccentric geodesic. First, we calculate the O({mu}/M) conservative correction to the periastron advance of the orbit, as a function of the (gauge-dependent) semilatus rectum and eccentricity. A gauge-invariant description of the GSF precession effect is made possible in the circular-orbit limit, where we express the correction to the periastron advance as a function of the invariant azimuthal frequency. We compare this relation with results from fully nonlinear numerical-relativistic simulations. In order to obtain a gauge-invariant measure of the GSF effect for fully eccentric orbits, we introduce a suitable generalization of Detweiler's circular-orbit ''redshift'' invariant. We compute the O({mu}/M) conservative correction to this invariant, expressed as a function of the two invariant frequencies that parametrize the orbit. Our results are in good agreement with results from post-Newtonian calculations in the weak-field regime, as we shall report elsewhere. The results of our study can inform the development of analytical models for the dynamics of strongly gravitating binaries. They also provide an accurate benchmark for future numerical-relativistic simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Particle classification and dynamics in GL(2,C) gravity

A relatively simple approach to noncommutative gravity utilizes the gauge theory formulation of general relativity and involves replacing the Lorentz gauge group by a larger group. This results in additional field degrees of freedom which either must be constrained to vanish in a nontrivial way or require physical interpretation. With the latter in mind, we examine the coupling of the additional fields to point particles. Nonstandard particle degrees of freedom should be introduced in order to write down the most general coupling. The example we study is the GL(2,C) central extension of gravity given by Chamseddine, which contains two U(1) gauge fields and a complex vierbein matrix, along with the usual spin connections. For the general coupling one should then attach two U(1) charges and a complex momentum vector to the particle, along with the spin. The momenta span orbits in a four-dimensional complex vector space and are classified by GL(2,C) invariants and by their little groups. In addition to orbits associated with standard massive and massless particles, a number of novel orbits can be identified. We write down a general action principle for particles associated with any nontrivial orbit and show that it leads to corrections to geodesic motion. We also examine the classical and quantum theory of the particle in flat space-time.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effect of Multiple Scattering on the Compton Recoil Current Generated in an EMP, Revisited

Multiple scattering has historically been treated in EMP modeling through the obliquity factor. The validity of this approach is examined here. A simplified model problem, which correctly captures cyclotron motion, Doppler shifting due to the electron motion, and multiple scattering is first considered. The simplified problem is solved three ways: the obliquity factor, Monte-Carlo, and Fokker-Planck finite-difference. Because of the Doppler effect, skewness occurs in the distribution. It is demonstrated that the obliquity factor does not correctly capture this skewness, but the Monte-Carlo and Fokker-Planck finite-difference approaches do. Here, the obliquity factor and Fokker-Planck finite-difference approaches are then compared in a fuller treatment, which includes the initial Klein-Nishina distribution of the electrons, and the momentum dependence of both drag and scattering. It is found that, in general, the obliquity factor is adequate for most situations. However, as the gamma energy increases and the Klein-Nishina becomes more peaked in the forward direction, skewness in the distribution causes greater disagreement between the obliquity factor and a more accurate model of multiple scattering.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Transonic Correction to Theodorsen's Theory for Oscillating Airfoil in Pitch and Plunge Toward Flutter

This paper presents a transonic correction method for an oscillating airfoil in pitch and plunge. The proposed method applies correction functions to the Theodorsen’s theory to capture the transonic nonlinear aero- dynamics. These correction functions apply necessary corrections to the amplitudes and the phase angles of the unsteady lift and pitching moment coefficients to account for transonic aerodynamics. The proposed method also postulates a correction for the motion of the aerodynamic center which could be induced by moving shocks. A series of unsteady RANS CFD simulations of the airfoil at the mean aerodynamic chord of the Transonic Truss-Braced Wing aircraft are conducted using FUN3D to provide data to construct these transonic correction functions. The computed responses of the unsteady lift and pitching moment coefficients using these transonic correction functions match the CFD simulation results very well even when the pitching moment coefficient is highly nonlinear. A flutter analysis of an airfoil in pitch and plunge illustrates the potential use of the proposed transonic correction method.

Transonic Flutter↗

Correcting magnetic resonance k-space data for in-plane motion using an optical position tracking system

Purpose: Motion is a major confound of image quality in MRI. A method of retrospectively correcting the effects of rotations and translations on the acquired k-space data is presented. Methods: In two phantom experiments of well-controlled translation and rotation, two MRI-compatible infrared cameras recorded motion data that were used subsequently to correct the position and phase of recorded k-space samples. Motion data can be acquired with a temporal resolution of 60 Hz and spatial accuracy of 0.1 mm for translations and 0.2 deg. for rotations. Results: Significant improvements of image quality are demonstrated. Conclusions: The key advantages of the technique are that it is easy to implement, does not interfere with or complicate MR data acquisition, and is capable of correcting distortions within a single slice. Therefore, the technique has the potential to improve upon approaches that rely on the registration or realignment of successive imaging slices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Residual motions caused by micro-gravitational accelerations

It is shown here that, under certain conditions, the low-frequency accelerations on experiments being performed aboard orbiting spacecraft due to gravity gradient, atmospheric drag, and spacecraft attitude or orientation can cause sustained fluid motions which require correction by advanced mass compensation techniques. The gravity gradient tensor is derived, and an expression for the difference between the absolute accelerations of a free particle and the mass center of the spacecraft is obtained. A model for the variation of atmospheric density with altitude is discussed, the equations governing the relative motion of a drag-free particle with respect to the mass center of the spacecraft are presented, and analytical and numerical solutions are obtained. Two possible spacecraft altitudes are considered. The problem of the Stokes motion of a sphere immersed in a viscous fluid is examined. Results are presented for the motion of a steel ball in water and for a triglycine sulfate crystal freely suspended in solution.

Alexander, J. Iwan D.↗

RELATIVISTIC CORRECTION TO THE MOVEMENT OF MAGNETIC POLES

The equations of motion, modified by the relativistic correction to a rotating inclined magnetic field, are discussed. It is shown that the magnetic moment would precess under the influence of the retardation torques identifiable by several higher-order terms in the relativistic correction. The observed cyclical behaviors from the clock-like pulse-emitting pulsars reported by many researchers are likely to be the consequences of the retardation effect produced by an inclined magnetic moment of a spinning body. The results, which come from the study of two independently rotating magnetic moments, are in agreement with the observed pulsar data for the pulsar PSR B1828-11. These electromagnetic driving forces are presented for further exploration and discussion.

79 ASTRONOMY AND ASTROPHYSICS↗

Accuracy of gravitational physics tests using ranges to the inner planets

A number of different types of deviations from Kepler's laws for planetary orbits can occur in nonNewtonian metric gravitational theories. These include secular changes in all of the orbital elements and in the mean motion, plus additional periodic perturbations in the coordinates. The first order corrections to the Keplerian motion of a single planet around the Sun due to the parameterized post Newtonian theory parameters were calculated as well as the corrections due to the solar quadrupole moment and a possible secular change in the gravitational constant. The results were applied to the case of proposed high accuracy ranging experiments from the Earth to a Mercury orbiting spacecraft in order to see how well the various parameters can be determined.

Ashby, N.↗

MO-B-201-00: Motion Management in Current Stereotactic Body Radiation Therapy (SBRT) Practice

The motion management in stereotactic body radiation therapy (SBRT) is a key to success for a SBRT program, and still an on-going challenging task. A major factor is that moving structures behave differently than standing structures when examined by imaging modalities, and thus require special considerations and employments. Understanding the motion effects to these different imaging processes is a prerequisite for a decent motion management program. The commonly used motion control techniques to physically restrict tumor motion, if adopted correctly, effectively increase the conformity and accuracy of hypofractionated treatment. The effective application of such requires one to understand the mechanics of the application and the related physiology especially related to respiration. The image-guided radiation beam control, or tumor tracking, further realized the endeavor for precision-targeting. During tumor tracking, the respiratory motion is often constantly monitored by non-ionizing beam sources using the body surface as its surrogate. This then has to synchronize with the actual internal tumor motion. The latter is often accomplished by stereo X-ray imaging or similar techniques. With these advanced technologies, one may drastically reduce the treated volume and increase the clinicians’ confidence for a high fractional ablative radiation dose. However, the challenges in implementing the motion management may not be trivial and is dependent on each clinic case. This session of presentations is intended to provide an overview of the current techniques used in managing the tumor motion in SBRT, specifically for routine lung SBRT, proton based treatments, and newly-developed MR guided RT. Learning Objectives: Through this presentation, the audience will understand basic roles of commonly used imaging modalities for lung cancer studies; familiarize the major advantages and limitations of each discussed motion control methods; familiarize the major advantages and limitations of each discussed radiation beam control methodology and tumor tacking method; understand the key points in motion management for a high quality SBRT program.

60 APPLIED LIFE SCIENCES↗

MO-B-201-01: Overcoming the Challenges of Motion Management in Current Lung SBRT Practice

The motion management in stereotactic body radiation therapy (SBRT) is a key to success for a SBRT program, and still an on-going challenging task. A major factor is that moving structures behave differently than standing structures when examined by imaging modalities, and thus require special considerations and employments. Understanding the motion effects to these different imaging processes is a prerequisite for a decent motion management program. The commonly used motion control techniques to physically restrict tumor motion, if adopted correctly, effectively increase the conformity and accuracy of hypofractionated treatment. The effective application of such requires one to understand the mechanics of the application and the related physiology especially related to respiration. The image-guided radiation beam control, or tumor tracking, further realized the endeavor for precision-targeting. During tumor tracking, the respiratory motion is often constantly monitored by non-ionizing beam sources using the body surface as its surrogate. This then has to synchronize with the actual internal tumor motion. The latter is often accomplished by stereo X-ray imaging or similar techniques. With these advanced technologies, one may drastically reduce the treated volume and increase the clinicians’ confidence for a high fractional ablative radiation dose. However, the challenges in implementing the motion management may not be trivial and is dependent on each clinic case. This session of presentations is intended to provide an overview of the current techniques used in managing the tumor motion in SBRT, specifically for routine lung SBRT, proton based treatments, and newly-developed MR guided RT. Learning Objectives: Through this presentation, the audience will understand basic roles of commonly used imaging modalities for lung cancer studies; familiarize the major advantages and limitations of each discussed motion control methods; familiarize the major advantages and limitations of each discussed radiation beam control methodology and tumor tacking method; understand the key points in motion management for a high quality SBRT program.

60 APPLIED LIFE SCIENCES↗

MO-B-201-02: Motion Management for Proton Lung SBR

The motion management in stereotactic body radiation therapy (SBRT) is a key to success for a SBRT program, and still an on-going challenging task. A major factor is that moving structures behave differently than standing structures when examined by imaging modalities, and thus require special considerations and employments. Understanding the motion effects to these different imaging processes is a prerequisite for a decent motion management program. The commonly used motion control techniques to physically restrict tumor motion, if adopted correctly, effectively increase the conformity and accuracy of hypofractionated treatment. The effective application of such requires one to understand the mechanics of the application and the related physiology especially related to respiration. The image-guided radiation beam control, or tumor tracking, further realized the endeavor for precision-targeting. During tumor tracking, the respiratory motion is often constantly monitored by non-ionizing beam sources using the body surface as its surrogate. This then has to synchronize with the actual internal tumor motion. The latter is often accomplished by stereo X-ray imaging or similar techniques. With these advanced technologies, one may drastically reduce the treated volume and increase the clinicians’ confidence for a high fractional ablative radiation dose. However, the challenges in implementing the motion management may not be trivial and is dependent on each clinic case. This session of presentations is intended to provide an overview of the current techniques used in managing the tumor motion in SBRT, specifically for routine lung SBRT, proton based treatments, and newly-developed MR guided RT. Learning Objectives: Through this presentation, the audience will understand basic roles of commonly used imaging modalities for lung cancer studies; familiarize the major advantages and limitations of each discussed motion control methods; familiarize the major advantages and limitations of each discussed radiation beam control methodology and tumor tacking method; understand the key points in motion management for a high quality SBRT program.

60 APPLIED LIFE SCIENCES↗

MO-B-201-03: MRI-Guided Tracking and Gating

The motion management in stereotactic body radiation therapy (SBRT) is a key to success for a SBRT program, and still an on-going challenging task. A major factor is that moving structures behave differently than standing structures when examined by imaging modalities, and thus require special considerations and employments. Understanding the motion effects to these different imaging processes is a prerequisite for a decent motion management program. The commonly used motion control techniques to physically restrict tumor motion, if adopted correctly, effectively increase the conformity and accuracy of hypofractionated treatment. The effective application of such requires one to understand the mechanics of the application and the related physiology especially related to respiration. The image-guided radiation beam control, or tumor tracking, further realized the endeavor for precision-targeting. During tumor tracking, the respiratory motion is often constantly monitored by non-ionizing beam sources using the body surface as its surrogate. This then has to synchronize with the actual internal tumor motion. The latter is often accomplished by stereo X-ray imaging or similar techniques. With these advanced technologies, one may drastically reduce the treated volume and increase the clinicians’ confidence for a high fractional ablative radiation dose. However, the challenges in implementing the motion management may not be trivial and is dependent on each clinic case. This session of presentations is intended to provide an overview of the current techniques used in managing the tumor motion in SBRT, specifically for routine lung SBRT, proton based treatments, and newly-developed MR guided RT. Learning Objectives: Through this presentation, the audience will understand basic roles of commonly used imaging modalities for lung cancer studies; familiarize the major advantages and limitations of each discussed motion control methods; familiarize the major advantages and limitations of each discussed radiation beam control methodology and tumor tacking method; understand the key points in motion management for a high quality SBRT program.

60 APPLIED LIFE SCIENCES↗

The use of Bayesian inversion to resolve plasma equilibrium

Recently, Bayesian probability theory has been used at a number of experiments to fold uncertainties and interdependencies in the diagnostic data and forward models, together with prior knowledge of the state of the plasma, to increase accuracy of inferred physics variables. A new probabilistic framework, MINERVA, based on Bayesian graphical models, has been used at JET and W7-AS to yield predictions of internal magnetic structure. A feature of the framework is the Bayesian inversion for poloidal magnetic flux without the need for an explicit equilibrium assumption. Building on this, we discuss results from a new project to develop Bayesian inversion tools that aim to (1) distinguish between competing equilibrium theories, which capture different physics, using the MAST spherical tokamak, and (2) test the predictions of MHD theory, particularly mode structure, using the H-1 Heliac. Specifically, we report on correction of the motional Stark effect, pickup coils, flux-loop constrained Bayesian inferred equilibrium for varying toroidal flux.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DIRECT IMAGING IN THE HABITABLE ZONE AND THE PROBLEM OF ORBITAL MOTION

High contrast imaging searches for exoplanets have been conducted on 2.4-10 m telescopes, typically at H band (1.6 {mu}m) and used exposure times of {approx}1 hr to search for planets with semi-major axes of {approx}> 10 AU. We are beginning to plan for surveys using extreme-AO systems on the next generation of 30 m class telescopes, where we hope to begin probing the habitable zones (HZs) of nearby stars. Here we highlight a heretofore ignorable problem in direct imaging: planets orbit their stars. Under the parameters of current surveys, orbital motion is negligible over the duration of a typical observation. However, this motion is not negligible when using large diameter telescopes to observe at relatively close stellar distances (1-10 pc), over the long exposure times (10-20 hr) necessary for direct detection of older planets in the HZ. We show that this motion will limit our achievable signal-to-noise ratio and degrade observational completeness. Even on current 8 m class telescopes, orbital motion will need to be accounted for in an attempt to detect HZ planets around the nearest Sun-like stars {alpha} Cen A and B, a binary system now known to harbor at least one planet. Here we derive some basic tools for analyzing this problem, and ultimately show that the prospects are good for de-orbiting a series of shorter exposures to correct for orbital motion.

79 ASTRONOMY AND ASTROPHYSICS↗

Analytic image reconstruction from partial data for a single-scan cone-beam CT with scatter correction

Purpose: A beam-blocker composed of multiple strips is a useful gadget for scatter correction and/or for dose reduction in cone-beam CT (CBCT). However, the use of such a beam-blocker would yield cone-beam data that can be challenging for accurate image reconstruction from a single scan in the filtered-backprojection framework. The focus of the work was to develop an analytic image reconstruction method for CBCT that can be directly applied to partially blocked cone-beam data in conjunction with the scatter correction. Methods: The authors developed a rebinned backprojection-filteration (BPF) algorithm for reconstructing images from the partially blocked cone-beam data in a circular scan. The authors also proposed a beam-blocking geometry considering data redundancy such that an efficient scatter estimate can be acquired and sufficient data for BPF image reconstruction can be secured at the same time from a single scan without using any blocker motion. Additionally, scatter correction method and noise reduction scheme have been developed. The authors have performed both simulation and experimental studies to validate the rebinned BPF algorithm for image reconstruction from partially blocked cone-beam data. Quantitative evaluations of the reconstructed image quality were performed in the experimental studies. Results: The simulation study revealed that the developed reconstruction algorithm successfully reconstructs the images from the partial cone-beam data. In the experimental study, the proposed method effectively corrected for the scatter in each projection and reconstructed scatter-corrected images from a single scan. Reduction of cupping artifacts and an enhancement of the image contrast have been demonstrated. The image contrast has increased by a factor of about 2, and the image accuracy in terms of root-mean-square-error with respect to the fan-beam CT image has increased by more than 30%. Conclusions: The authors have successfully demonstrated that the proposed scanning method and image reconstruction algorithm can effectively estimate the scatter in cone-beam projections and produce tomographic images of nearly scatter-free quality. The authors believe that the proposed method would provide a fast and efficient CBCT scanning option to various applications particularly including head-and-neck scan.

60 APPLIED LIFE SCIENCES↗