Search NASA⌕ Search

SEARCH · Search NASA

Results for “motion simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

SU-F-BRD-11: A Virtual Simulator Designed for Collision Prevention in Proton Therapy

Purpose: In proton therapy, collisions between patient and nozzle potentially occur in attaining minimal air gap due to the large nozzle structure. Thus, we developed software predicting the collisions of the nozzle and patient by simulating treatments. Methods: 3D modeling of a gantry inner-floor, nozzle and robotic-couch was done by using the SolidWorks based on the manufacturer’s machine data. To obtain patient body information, a 3D-scanner was utilized to scan a patient right before CT scanning. From the acquired images, a 3D-image of the patient’s body contour was reconstructed. The accuracy of the image was confirmed against the CT image for a humanoid phantom. The machine components and the virtual patient were combined on the treatment-room coordinate system, resulting in a virtual simulator. The simulator simulated the motion of its components such as rotation and translation of gantry, nozzle and couch, in real scale. Collision, if any, was examined both in static mode and dynamic mode. The static mode checks only at fixed positions of the machine’s components while dynamic mode examines while one component is in motion. Collision was notified if any voxel of two components, for example a nozzle and a patient or couch, overlapped when calculating volume locations. The event and collision point are visualized and colliding volumes are reported. Results: All components were successfully assembled and the motions could be accurately controlled. The 3D-shape of a phantom agreed with CT images within a deviation of 2 mm. Collision situations can be simulated within minutes and the results are displayed and reported. Conclusion: The developed software will be useful in improving patient safety and clinical efficiency for proton therapy. This work was supported by the National Research Foundation of Korea funded by Ministry of Science, ICT & Future Planning (2012M3A9B6055201, 2013M2A2A7043507), and Samsung Medical Center grant (GFO1130081)

60 APPLIED LIFE SCIENCES↗

TU-AB-303-11: Predict Parotids Deformation Applying SIS Epidemiological Model in H&N Adaptive RT

Purpose: The aim is to investigate the use of epidemiological models to predict morphological variations in patients undergoing radiation therapy (RT). The susceptible-infected-susceptible (SIS) deterministic model was applied to simulate warping within a focused region of interest (ROI). Hypothesis is to consider each voxel like a single subject of the whole sample and to treat displacement vector fields like an infection. Methods: Using Raystation hybrid deformation algorithms and automatic re-contouring based on mesh grid, we post-processed 360 MVCT images of 12 H&N patients treated with Tomotherapy. Study focused on parotid glands, identified by literature and previous analysis, as ROI more susceptible to warping in H&N region. Susceptible (S) and infectious (I) cases were identified in voxels with inter-fraction movement respectively under and over a set threshold. IronPython scripting allowed to export positions and displacement data of surface voxels for every fraction. A MATLAB homemade toolbox was developed to model the SIS. Results: SIS model was validated simulating organ motion on QUASAR phantom. Applying model in patients, within a [0–1cm] range, a single voxel movement of 0.4cm was selected as displacement threshold. SIS indexes were evaluated by MATLAB simulations. Dynamic time warping algorithm was used to assess matching between model and parotids behavior days of treatments. The best fit of the model was obtained with contact rate of 7.89±0.94 and recovery rate of 2.36±0.21. Conclusion: SIS model can follow daily structures evolutions, making possible to compare warping conditions and highlighting challenges due to abnormal variation and set-up errors. By epidemiology approach, organ motion could be assessed and predicted not in terms of average of the whole ROI, but in a voxel-by-voxel deterministic trend. Identifying anatomical region subjected to variations, would be possible to focus clinic controls within a cohort of pre-selected patients eligible for adaptive RT. The research is partially co-funded by the Italian Research Grant: Dose warping methods for IGRT and Adaptive RT: dose accumulation based on organ motion and anatomical variations of the patients during radiation therapy treatments,MoH (GR-2010-2318757) and Tecnologie Avanzate S.r.l.(Italy)

60 APPLIED LIFE SCIENCES↗

Simulations of radiation damage as a function of the temporal pulse profile in femtosecond X-ray protein crystallography

Serial femtosecond X-ray crystallography of protein nanocrystals using ultrashort and intense pulses from an X-ray free-electron laser has proved to be a successful method for structural determination. However, due to significant variations in diffraction pattern quality from pulse to pulse only a fraction of the collected frames can be used. Experimentally, the X-ray temporal pulse profile is not known and can vary with every shot. This simulation study describes how the pulse shape affects the damage dynamics, which ultimately affects the biological interpretation of electron density. The instantaneously detected signal varies during the pulse exposure due to the pulse properties, as well as the structural and electronic changes in the sample. Here ionization and atomic motion are simulated using a radiation transfer plasma code. Pulses with parameters typical for X-ray free-electron lasers are considered: pulse energies ranging from 10 4 to 10 7 J cm -2 with photon energies from 2 to 12 keV, up to 100 fs long. Radiation damage in the form of sample heating that will lead to a loss of crystalline periodicity and changes in scattering factor due to electronic reconfigurations of ionized atoms are considered here. The simulations show differences in the dynamics of the radiation damage processes for different temporal pulse profiles and intensities, where ionization or atomic motion could be predominant. Overall, the different dynamics influence the recorded diffracted signal in any given resolution and will affect the subsequent structure determination.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pore-scale CFD simulations of clay mobilization in natural porous media due to fresh water injection

The present work investigates mechanisms of permeability impairment as a result of low-salinity fluid injection into brine-saturated porous media containing dispersible clays. Here, we present a computational fluid dynamics model at the pore-scale to simulate detachment, migration and straining of fine particles in porous media. The model uses an immersed boundary method to simulate the motion of clay fines in a fluid. In addition to the hydrodynamic forces, we model the Derjaguin-Landau-Verwey-Overbeek forces (DLVO) between clay fines and grains. Our simulations show the impact of the injected fluid's salinity and velocity on the concentration of clay fines retained on the grain surface. We see clay particles dislodging from the grain surface in clusters of up to 12 particles. Our simulation results also demonstrate clogging of narrow pore spaces by the detached particles from the grain surfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-F-T-389: Validation in 4D Dosimetry Using Dynamic Phantom

Purpose: Tumor motion due to respiration causes the uncertainties during the radiotherapy. This study aims to find the differences between planning dose by treatment planning and the received dose using dynamic phantom. Methods: Respiratory motion was simulated by the DYNAMIC THORAX PHANTOM (Model 008A). 4D-CT scans and maximum intensity projection (MIP) images for GTV were acquired for analysis. The amplitude of craniocaudal tumor motion including 2mm, 5mm, 10mm and 20mm with 3cm2 tumor size were performed in this study. The respiratory cycles of 4-seconds and 6-seconds were included as the different breathing modes. IMRT, VAMT, and Tomotherapy were utilized for treatment planning. Ion chamber and EBT3 were used to measure the point dose and planar dose. Dose distributions with different amplitudes, respiratory cycles, and planning techniques were all measured and compared to calculations. Results: The variations between the does measurements and calculation dose by treatment planning system were found in both point dose and dose distribution. The 0.83% and 5.46 % differences in dose average were shown on phantom with motions using 2mm amplitude in 4 second respiratory cycle, and 20mm amplitude in 4 second respiratory cycle, respectively. The most point dose overestimation as compared of the calculations was shown the plan generated by Tomotherapy. The underestimations of planar dose as compared of calculations was found in the 100% coverage doses for GTV. Conclusion: The loss of complete (100%) GTV coverage was the predominant effect of respiratory motion observed in this study. Motion amplitude and treatment planning system were the major factors leading the dose measurement variation as compared of planning calculations.

60 APPLIED LIFE SCIENCES↗

TH-AB-202-07: Radar Tracking of Respiratory Motion in Real Time

Purpose: To propose a method of real time tracking of respiratory motion in patients undergoing radiation therapy. Radar technology can be employed to detection the movement of diaphragm and thoracic anatomy. Methods: A radar transceiver was specially designed. During experiment, the radar device was securely attached to a fixed frame. Respiratory motion was simulated with: 1) Varian RPM phantom, 2) Standard Imaging Respiratory Gating Platform. Signals recorded with radar equipment were compared with those measured with Varian RPM system as a reference. Results: Motion generated by Varian RPM phantom was recorded by the radar device, and compared to the signals recorded by RPM camera. The results showed exact agreement between the two monitoring equipments. Motion was also generated by Standard Imaging Respiratory Motion Platform. The results showed the radar device was capable of measuring motion of various amplitudes and periods. Conclusion: The proposed radar device is able to measure movements such as respiratory motion. Compared to state-of-the-art respiratory detection instrument, the radar device is shown to be equally precise and effective for monitoring respiration in radiation oncology patients.

60 APPLIED LIFE SCIENCES↗

In vivo dosimetry for gynaecological brachytherapy using a novel position sensitive radiation detector: Feasibility study

Purpose: In gynecological radiotherapy with high dose rate (HDR){sup 192}Ir brachytherapy, the treatment complexity has increased due to improved optimization techniques and dose constraints. As a consequence, it has become more important to verify the dose delivery to the target and also to the organs at risk (e.g., the bladder). In vivo dosimetry, where dosimeters are placed in or on the patient, is one way of verifying the dose but until recently this was hampered by motion of the radiation detectors with respect to the source. The authors present a novel dosimetry method using a position sensitive radiation detector. Methods: The prototype RADPOS system (Best Medical Canada) consists of a metal oxide field effect transistor (MOSFET) dosimeter coupled to a position-sensor, which deduces its 3D position in a magnetic field. To assess the feasibility of in vivo dosimetry based on the RADPOS system, different characteristics of the detector need to be investigated. Using a PMMA phantom, the positioning accuracy of the RADPOS system was quantified by comparing position readouts with the known position of the detector along the x and y-axes. RADPOS dose measurements were performed at various distances from a Nucletron{sup 192}Ir source in a PMMA phantom to evaluate the energy dependence of the MOSFET. A sensitivity analysis was performed by calculating the dose after varying (1) the position of the RADPOS detector to simulate organ motion and (2) the position of the first dwell position to simulate errors in delivery. The authors also performed an uncertainty analysis to determine the action level (AL) that should be used during in vivo dosimetry. Results: Positioning accuracy is found to be within 1 mm in the 1-10 cm range from the origin along the x-axis (away from the transmitter), meeting the requirements for in vivo dosimetry. Similar results are obtained for the other axes. The ALs are chosen to take into account the total uncertainty on the measurements. As a consequence for in vivo dosimetry, it is determined that the RADPOS sensor, if placed, for example, in the bladder Foley balloon, would detect a 2 mm motion of the bladder, at a 5% chance of a false positive, with an AL limit of 9% of the dose delivered. The authors found that source position errors, caused by, e.g., a wrong first dwell position, are more difficult to detect; indeed, with our single RADPOS detector, positioned in the bladder, dwell position errors below 5 mm and resulting in a dose error within 10%, could be detected in the tandem but not in the colpostats. A possible solution to improve error detection is to use multiple MOSFETs to obtain multiple dose values. Conclusions: In this study, the authors proposed a dosimetry procedure, based on the novel RADPOS system, to accurately determine the position of the radiation dosimeter with respect to the applicator. The authors found that it is possible to monitor the delivered dose in a point and compare it to the predetermined dose. This allows in principle the detection of problems such as bladder motion/filling or source mispositioning. Further clinical investigation is warranted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PEBBLES

The PEBBLES code is a computer program designed to simulate the motion, packing and vibration of spheres that undergo various mechanical forces including gravitation, Hooke's law force and various friction forces. The frictional forces include true static friction that allows non-zero angles of repose. Each pebble is individually simulated using the distinct element method. The program outputs various tallies as textual numbers. These tallies include pebble position, pebble angular and linear velocity, force on the wall and between pebbles, probabilities of pebbles moving between different locations, accumulated amount of linear motion between pebbles, and average velocity in different regions of the container.

Cogliati, JoshuaJ.↗

Rupture Dynamics Simulations of Shallow Crustal Earthquakes on Reverse Slip Faults

The main goal of this study was to perform dynamic rupture simulations in order constrain the characterization of kinematic rupture models implemented in techniques for simulating strong ground motion for crustal earthquakes. First, we investigated the rupture process of the 2008 Iwate-Miyagi Nairiku earthquake by developing a dynamic rupture model on a reverse fault using a trial-and-error technique that produced a slip distribution and near-fault ground motion that matched the recorded ones. The simulations were performed in the frequency range 0-2 Hz, using a 3D staggered grid finite-difference method and a linear slip weakening friction law. Constrained by the observed slip distribution and consistent with dynamic rupture models, the derived kinematic rupture model of the Iwate-Miyagi Nairiku earthquake contains areas with relatively large slip rate, representing strong motion generation areas, set against lower amplitude heterogeneous background slip, and a relatively low slip rate in the weak zone of the top-most crust (upper 3km). Second, we performed rupture dynamics modeling to constrain shallow slip characterization in rupture models for strike-slip crustal earthquakes. The objective was to establish general rules about the characterization of slip rate function and slip at shallow depths and in the strong motion generation areas (SMGAs). The simulations of spontaneous rupture were performed in the frequency range 0-2.0Hz, using a 3D staggered-grid finite-difference method and a layer over half-space 1D crustal velocity model with a minimum shear-wave velocity of 2.8 km/s. In order to account for changes in material ductility and reduction of stress drop, observed in the shallow crust (upper 3-5 km), and the transition from ductile state to brittle state in the upper seismogenic zone, in our stress models we included a shallow weak zone (<4km). In this zone the stress drop was set to zero at the free surface and gradually increased with depth, while the slip weakening distance was set to 75 cm at the free surface and decreased to 50 cm at the base of the weak zone. As in the case of reverse faulting during the Iwate-Miyagi Nairiku earthquake, from these computations we found a systematic change in the shape of the slip-rate function, from Kostrov-type in the deeper part of the fault to a more symmetric cosine-type in the upper few kilometers, near the free-surface. Moreover, the average slip duration in the weak zone, with respect to slip duration in the deeper parts of the fault, increases by at most a factor of 1.5. We found a systematic and gradual change in the shape of the slip-rate function from Kostrov-type in the asperity areas (SMGAs), to more symmetric cosine-type in the upper few km near the free-surface, on the long period motion generation area (LMGA). The effective rise time in the LMGA, with respect to that in the SMGAs, increases by at most a factor of 2. Effective rise time is the time difference between the time at which the slip rate drops to a level that is equal to 25% of its peak and the onset time of the signal. In addition, the slip in the LMGA located above the SMGAs is almost the same as the one in the SMGAs, and about 1.5 times larger than the average slip.

58 GEOSCIENCES↗

TH-EF-BRB-08: Robotic Motion Compensation for Radiation Therapy: A 6DOF Phantom Study

Purpose: The high accuracy of frame-based stereotactic radiosurgery (SRS), which uses a rigid frame fixed to the patient’s skull, is offset by potential drawbacks of poor patient compliance and clinical workflow restrictions. Recent research into frameless SRS has so far resulted in reduced accuracy. In this study, we investigate the use of a novel 6 degree-of-freedom (6DOF) robotic head motion cancellation system that continuously detects and compensates for patient head motions during a SRS delivery. This approach has the potential to reduce invasiveness while still achieving accuracies better or equal to traditional frame-based SRS. Methods: A 6DOF parallel kinematics robotics stage was constructed, and controlled using an inverse kinematics-based motion compensation algorithm. A 6DOF stereoscopic infrared (IR) marker tracking system was used to monitor real-time motions at sub-millimeter and sub-degree levels. A novel 6DOF calibration technique was first applied to properly orient the camera coordinate frame to match that of the LINAC and robotic control frames. Simulated head motions were measured by the system, and the robotic stage responded to these 6DOF motions automatically, returning the reflective marker coordinate frame to its original position. Results: After the motions were introduced to the system in the phantom-based study, the robotic stage automatically and rapidly returned the phantom to LINAC isocenter. When errors exceeded the compensation lower threshold of 0.25 mm or 0.25 degrees, the system registered the 6DOF error and generated a cancellation trajectory. The system responded in less than 0.5 seconds and returned all axes to less than 0.1 mm and 0.1 degree after the 6DOF compensation was performed. Conclusion: The 6DOF real-time motion cancellation system was found to be effective at compensating for translational and rotational motions to current SRS requirements. This system can improve frameless SRS by automatically returning patients to isocenter with high 6DOF accuracy.

60 APPLIED LIFE SCIENCES↗

An Efficient Time-Domain Model to Simulate Parametric Resonances in a Floating Body Free to Move in Six Degrees of Freedom: Preprint

We present a computationally efficient time-domain model capable of simulating parametric resonances in a floating body in waves. The model assumes all wave forces to be linear, but the inertia and restoring forces acting on the body are expanded to second order in body motions. The simulation speed on a standard computer is approximately 40 times faster than real time. The model is applied to a soft-moored floating axisymmetric body which absorbs energy through heave, but is otherwise free to move in six degrees of freedom. Under certain conditions, we show that the body responds parametrically with large amplitudes not only in surge and pitch, but also in sway, roll, and yaw, provided it is given some small initial displacement in one of these out-of-plane modes. The predictions are confirmed by simulations using state-of-the-art nonlinear Froude-Krylov and computational fluid dynamics models.

parametric resonance↗

SU-E-J-150: Four-Dimensional Cone-Beam CT Algorithm by Extraction of Physical and Motion Parameter of Mobile Targets Retrospective to Image Reconstruction with Motion Modeling

Purpose: To develop 4D-cone-beam CT (CBCT) algorithm by motion modeling that extracts actual length, CT numbers level and motion amplitude of a mobile target retrospective to image reconstruction by motion modeling. Methods: The algorithm used three measurable parameters: apparent length and blurred CT number distribution of a mobile target obtained from CBCT images to determine actual length, CT-number value of the stationary target, and motion amplitude. The predictions of this algorithm were tested with mobile targets that with different well-known sizes made from tissue-equivalent gel which was inserted into a thorax phantom. The phantom moved sinusoidally in one-direction to simulate respiratory motion using eight amplitudes ranging 0–20mm. Results: Using this 4D-CBCT algorithm, three unknown parameters were extracted that include: length of the target, CT number level, speed or motion amplitude for the mobile targets retrospective to image reconstruction. The motion algorithms solved for the three unknown parameters using measurable apparent length, CT number level and gradient for a well-defined mobile target obtained from CBCT images. The motion model agreed with measured apparent lengths which were dependent on the actual target length and motion amplitude. The gradient of the CT number distribution of the mobile target is dependent on the stationary CT number level, actual target length and motion amplitude. Motion frequency and phase did not affect the elongation and CT number distribution of the mobile target and could not be determined. Conclusion: A 4D-CBCT motion algorithm was developed to extract three parameters that include actual length, CT number level and motion amplitude or speed of mobile targets directly from reconstructed CBCT images without prior knowledge of the stationary target parameters. This algorithm provides alternative to 4D-CBCT without requirement to motion tracking and sorting of the images into different breathing phases which has potential applications in diagnostic CT imaging and radiotherapy.

60 APPLIED LIFE SCIENCES↗

Microfield dynamics in dense hydrogen plasmas with high- Z impurities

We use large-scale classical molecular dynamics to determine microfield properties for several dense plasma mixtures. By employing quantum statistical potentials (QSPs) to regularize the Coulomb interaction, our simulations follow motions of electrons as well as ions for times long enough to track relaxation phenomena involving both types of particles. Coulomb coupling, relative to temperature, of different pairs of species in the hot, dense matter being simulated ranges from weak to strong. We first study the effect of such coupling differences, along with composition and QSP differences, on the roles of electrons and various mixture components in determining probability distributions of instantaneous, total microfields experienced by the ions. Then, we address two important dynamical questions: (1) How is the quasistatic part of the total field to be extracted from the time-dependent simulation data? (2) Under what conditions does the commonly used approximation of ions with fixed Yukawa-like screening by free electrons accurately describe quasistatic fields? We identify a running, short-time average of the total field at each ion as its slowly evolving, quasistatic part. We consider several ways to specify the averaging interval, and note the influence of ion dynamics in this issue. When all species are weakly coupled, the quasistatic fields have probability distributions agreeing well with those we obtain from simulations of Yukawa-screened ions. However, agreement deteriorates as the coupling between high- Z ions increases well beyond unity, principally because the Yukawa model tends to underestimate the true screening of close high- Z pairs. Lastly, examples of this fact are given, and some consequences for the high-field portions of probability distributions are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

PEBBLES Operation and Theory Manual

The PEBBLES manual describes the PEBBLES code. The PEBBLES code is a computer program designed to simulation the motion, packing and vibration of spheres that undergo various mechanical forces including gravitation, Hooke’s law force and various friction forces. The frictional forces include true static friction that allows non-zero angles of repose. Each pebble is individually simulated using the distinct element method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

PEBBLES Operation and Theory Manual

The PEBBLES manual describes the PEBBLES code. The PEBBLES code is a computer program designed to simulation the motion, packing and vibration of spheres that undergo various mechanical forces including gravitation, Hooke’s law force and various friction forces. The frictional forces include true static friction that allows non-zero angles of repose. Each pebble is individually simulated using the distinct element method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Geometrically projected discrete dislocation dynamics

Three-dimensional discrete dislocation dynamics methods (3D-DDD) have been developed to explicitly track the motion of individual dislocations under applied stress. At present, these methods are limited to plastic strains of about one percent or less due to high computational cost associated with the interactions between large numbers of dislocations. This limitation motivates the construction of minimalistic approaches to efficiently simulate the motion of dislocations for higher strains and longer time scales. In the present study, we propose geometrically projected discrete dislocation dynamics (GP-DDD), a method in which dislocation loops are modeled as geometrical objects that maintain their shape with a constant number of degrees of freedom as they expand. We present an example where rectangles composed of two screw and two edge dislocation segments are used for modeling gliding dislocation loops. We use this model to simulate single slip loading of copper and compare the results with detailed 3D-DDD simulations. We discuss the regimes in which GP-DDD is able to adequately capture the variation of the flow stress with strain rate in the single slip loading condition. In conclusion, a simulation using GP-DDD requires ~40 times fewer degrees of freedom for a copper single slip loading case, thus reducing computational time and complexity.

36 MATERIALS SCIENCE↗

Computational Fluid Dynamics Modeling of The Dalles Project: Effects of Spill Flow Distribution Between the Washington Shore and the Tailrace Spillwall

The U.S. Army Corps of Engineers-Portland District (CENWP) has ongoing work to improve the survival of juvenile salmonids (smolt) migrating past The Dalles Dam. As part of that effort, a spillwall was constructed to improve juvenile egress through the tailrace downstream of the stilling basin. The spillwall was designed to improve smolt survival by decreasing smolt retention time in the spillway tailrace and the exposure to predators on the spillway shelf. The spillwall guides spillway flows, and hence smolt, more quickly into the thalweg. In this study, an existing computational fluid dynamics (CFD) model was modified and used to characterize tailrace hydraulics between the new spillwall and the Washington shore for six different total river flows. The effect of spillway flow distribution was simulated for three spill patterns at the lowest total river flow. The commercial CFD solver, STAR-CD version 4.1, was used to solve the unsteady Reynolds-averaged Navier-Stokes equations together with the k-epsilon turbulence model. Free surface motion was simulated using the volume-of-fluid (VOF) technique. The model results were used in two ways. First, results graphics were provided to CENWP and regional fisheries agency representatives for use and comparison to the same flow conditions at a reduced-scale physical model. The CFD results were very similar in flow pattern to that produced by the reduced-scale physical model but these graphics provided a quantitative view of velocity distribution. During the physical model work, an additional spill pattern was tested. Subsequently, that spill pattern was also simulated in the numerical model. The CFD streamlines showed that the hydraulic conditions were likely to be beneficial to fish egress at the higher total river flows (120 kcfs and greater, uniform flow distribution). At the lowest flow case, 90 kcfs, it was necessary to use a non-uniform distribution. Of the three distributions tested, splitting the flow evenly between Bay 7 and Bay 8 had hydraulics deemed most beneficial for egress by CENWP fisheries biologists and regional fishery agency representatives. The numerical and physical model results were very similar, building confidence in both hydraulic tools.

13 HYDRO ENERGY↗

Large-Amplitude Motion Platform: A New Ocean Simulator Can Help Technologies Succeed

It's not always easy to build technologies hearty enough to operate in a powerful ocean environment. And subjecting promising prototypes to real ocean waves can be an expensive, time-consuming, and risky way to get these technologies ready for the high seas. Now, with the National Laboratory of the Rockies' (NLR's) testing platform, called the large-amplitude motion platform (or LAMP for short): www.nlr.gov/water/motion-platform, our experts can replicate powerful ocean waves in a low-risk laboratory setting. The LAMP, coupled with NLR's diverse array of testing instrumentation, can help technology developers rapidly hone their prototypes before embarking on a potentially costly and time-consuming ocean trial.

16 TIDAL AND WAVE POWER↗