Search NASA⌕ Search

SEARCH · Search NASA

Results for “natural gas utilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Advanced Modular Sub-Atmospheric Hybrid Heat Engine (Final Report)

The Phase 1 Final Technical Report describes the results of the work completed during the “Advanced Modular Sub-Atmospheric Hybrid Heat Engine” project. A key part of the Phase 1 work was the completion of a thermodynamic cycle analysis for the MHHE at the selected module size. The hybrid heat engine has been developed as a modular unit (sized in the range of 500kW – 60MW) that can be used with modular coal or biomass gasifiers, with distributed power generation systems, with large power plants comprised of multiple generating units, and with natural gas compression stations. The MHHE will provide cleaner, more efficient, and lower cost generation with better load following capabilities than existing competing technologies with a singular generating source such as solar farm, gas turbine, or combustion engine. The drivers of the MHHE technology are: benefits of modular power generation (reduced equipment cost, construction cost and implementation time, connection ready on delivery, flexible scalability, serviceability), fuel flexibility, lowest cost power generation and reduced emissions.A logical progression of work and a clear path forward toward meeting the FOA goals and objectives have been established. Namely, a preliminary market analysis and primary fuel identification was completed first and then the modularity of the system was defined. The benefits of the proposed hybrid and modular heat engine were described when applied to modular coal gasifiers, distributed power generators, and larger power plants. Based on the market analysis, modularity, and chosen primary fuel, a conceptual design and layout of the hybrid heat engine was developed, analyzed, and characterized. The technology gaps already identified have been reviewed and expanded upon, and a test plan to address these gaps through bench scale testing in Phase 2 has been developed. Cost estimate methodology and considerations in support of a potential Phase 2 project have been described.

08 HYDROGEN↗

Extended Low Load Boiler Operation to Improve Performance and Economics of an Existing Coal Fired Power Plant (Final Report)

The overall goal is to improve the performance and economics of existing coal fired power plants by extending low load boiler operation to lower loads than is currently achievable. The objective of this program is to develop and validate sensor hardware and analytical algorithms to lower plant operating expenses (OPEX) for the currently operating pulverized coal utility boiler fleet. Coal fired utility boilers are increasingly under grid dispatch pressure. In some cases, the coal fired cost of generation is noncompetitive with respect to natural gas generation and subsidized renewable sources. To remain profitable and remain fully compliant with existing environmental regulations, the installed coal fired fleet must find technologies which allow it to move into a more flexible cyclic load dispatch model. Today the installed coal fired utility fleet must be cost of generation competitive, fully emissions compliant, and responsive to the variability inherent in renewable energy generation sources. In the Phase I of the project, GE Steam Power, Inc. (GE) performed modeling of different operating scenarios for low load operation using an existing full plant dynamic model developed for a 660MW steam power plant. Sensors and analytic algorithms to enable a stable and steady coal supply for low load pulverizer operation were identified and tested at the Pulverizer Development Facility (PDF) at GE’s Clean Energy Center in Bloomfield, Connecticut. Sensors and analytic algorithms to enable stable combustion for low load operation were identified and tested at the 15 MWth Industrial Scale Burner facility (ISBF) at GE’s Clean Energy Center. A concept was developed to test the sensors and control algorithms, down selected after testing, at a full-scale coal fired power plant. A budget estimate was then developed, and the concept was implemented at an existing utility power plant. The specific objectives of the experimental work were to: • Identify and select sensors and analytic algorithms for monitoring coal pulverizer operation at lower loads to provide stable operation and appropriate coal fineness at lower coal throughput; Identify and select sensors and analytic algorithms for a Boiler Flame Stability Monitor to better balance air and fuel at each burner. This enables a reduction in a coal boiler’s safe low load power level while maintaining stable flame characteristics; Develop a concept in Phase I for low load operation of a full-scale power plant and develop a budget estimate for testing and execute the test plan at an existing plant in Phase II; Validate the capability of the extended low load boiler system to extend the minimum load operating point in a safe and reliable manner on an existing full-scale utility boiler. At the completion of this experimental study, GE has developed a set of sensors and analytic algorithms, down selected after testing, that have the potential to enable safe low load operation of a utility boiler. GE has also identified a host site for testing these identified sensors and analytic algorithms. GE has generated a full set of deliverables that provide sufficient information to proceed with the next step of testing at a host site. This includes a potential host site and budget estimate for concept testing at host site. In the Phase II of the project, a series of field tests were completed to validate the extended low load boiler operation, which consisted of detailed engineering, installation, commissioning, and testing the additional sensors and analytics for the coal-fired combustion system on an existing full-scale utility boiler. The optimization work has been supported by the host plant and endorsed by their engineering and operation staff.

01 COAL, LIGNITE, AND PEAT↗

ResStock Measure Documentation: Natural Gas Furnace 95% AFUE

This report is part of a series describing different ResStock (TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Natural Gas Furnace 95% AFUE" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Turbine Aero-Thermal Technologies for 65% Combined Cycle Efficiency (Phase I Final Report)

GE Power (GEP), a division of General Electric Company, performed a gas turbine technology development program that integrated Aerodynamic and Heat Transfer advances as an important and innovative step towards the DOE goal of 65% combined cycle efficiency. Improved efficiency will also contribute towards the reduction in the cost of electricity identified by the DOE for the US through reduced fuel consumption, and through lowering the capital cost of the generating equipment. It is currently predicted that the result of this project will enable 0.40~0.65 pt in combined cycle efficiency improvement. This technology will be directly applicable to gas turbines utilizing coal gasification processes where hydrogen-rich coal-derived synthesis gas is produced with natural gas being the developmental fuel.

03 NATURAL GAS↗

Spaceborne microwave remote sensing of seasonal freeze-thaw processes in theterrestrial high l atitudes : relationships with land-atmosphere CO2 exchange

Landscape transitions between seasonally frozen and thawed conditions occur each year over roughly 50 million square kilometers of Earth's Northern Hemisphere. These relatively abrupt transitions represent the closest analog to a biospheric and hydrologic on/off switch existing in nature, affecting surface meteorological conditions, ecological trace gas dynamics, energy exchange and hydrologic activity profoundly. We utilize time series satellite-borne microwave remote sensing measurements from the Special Sensor Microwave Imager (SSM/I) to examine spatial and temporal variability in seasonal freeze/thaw cycles for the pan-Arctic basin and Alaska. Regional measurements of spring thaw timing are derived using daily brightness temperature measurements from the 19 GHz, horizontally polarized channel, separately for overpasses with 6 AM and 6 PM equatorial crossing times. Spatial and temporal patterns in regional freeze/thaw dynamics show distinct differences between North America and Eurasia, and boreal forest and Arctic tundra biomes. Annual anomalies in the timing of thawing in spring also correspond closely to seasonal atmospheric CO2 concentration anomalies derived from NOAA CMDL arctic and subarctic monitoring stations. Classification differences between AM and PM overpass data average approximately 5 days for the region, though both appear to be effective surrogates for monitoring annual growing seasons at high latitudes.

Sensor Microwave Imager (SSM/I)carbon cycle↗

Spaceborne Microwave Remote Sensing of Seasonal Freeze-Thaw Processes in the Terrestrial High Latitudes: Relationships with Land-Atmosphere CO2 exchange

Landscape transitions between seasonally frozen and thawed conditions occur each year over roughly 50 million square kilometers of Earth's Northern Hemisphere. These relatively abrupt transitions represent the closest analog to a biospheric and hydrologic on/off switch existing in nature, affecting surface meteorological conditions, ecological trace gas dynamics, energy exchange and hydrologic activity profoundly. We utilize time series satellite-borne microwave remote sensing measurements from the Special Sensor Microwave Imager (SSM/I) to examine spatial and temporal variability in seasonal freeze/thaw cycles for the pan-Arctic basin and Alaska. Regional measurements of spring thaw timing are derived using daily brightness temperature measurements from the 19 GHz, horizontally polarized channel, separately for overpasses with 6 AM and 6 PM equatorial crossing times. Spatial and temporal patterns in regional freeze/thaw dynamics show distinct differences between North America and Eurasia, and boreal forest and Arctic tundra biomes. Annual anomalies in the timing of thawing in spring also correspond closely to seasonal atmospheric CO2 concentration anomalies derived from NOAA CMDL arctic and subarctic monitoring stations. Classification differences between AM and PM overpass data average approximately 5 days for the region, though both appear to be effective surrogates for monitoring annual growing seasons at high latitudes.

net primary products↗

Annual Technology Baseline: The 2022 Electricity Update

Consistent cost and performance data for various electricity generation technologies can be difficult to find and may change frequently for certain technologies. With the Annual Technology Baseline (ATB), the National Renewable Energy Laboratory annually provides an organized and centralized set of such cost and performance data. The ATB uses the best information from the Department of Energy national laboratories' renewable energy analysts. The ATB has been reviewed by experts and it includes the following electricity generation and storage technologies: land-based wind, offshore wind, distributed wind, utility-scale solar photovoltaics (PV), commercial-scale solar PV, residential-scale solar PV, concentrating solar power, geothermal power, hydropower, utility-scale battery storage, commercial battery storage, residential battery storage, pumped storage hydropower, coal, and natural gas. EIA data for nuclear and conventional biopower are included for reference. This webinar presentation introduces the 2022 update to the ATB Electricity data and documentation.

capacity factor↗

Annual Technology Baseline: The 2023 Electricity Update

Consistent cost and performance data for various electricity generation technologies can be difficult to find and may change frequently for certain technologies. With the Annual Technology Baseline (ATB), the National Renewable Energy Laboratory annually provides an organized and centralized set of such cost and performance data. The ATB uses the best information from the Department of Energy national laboratories' renewable energy analysts. The ATB has been reviewed by experts and it includes the following electricity generation and storage technologies: land-based wind, offshore wind, distributed wind, utility-scale solar photovoltaics (PV), commercial-scale solar PV, residential-scale solar PV, concentrating solar power, geothermal power, hydropower, utility-scale battery storage, commercial battery storage, residential battery storage, pumped storage hydropower, coal, and natural gas. EIA data for nuclear and conventional biopower are included for reference. This webinar presentation introduces the 2023 update to the ATB Electricity data and documentation.

capacity factor↗

Hydrogen and Battery Storage Technologies for Low-Cost Energy Decarbonization in Distribution Networks

Deep energy decarbonization cannot be achieved without high penetration of renewables. At higher renewable energy penetrations, the variability and intermittent nature of solar photovoltaic (PV) electricity can cause ramping issues with existing fossil fuel generation, requiring longer term energy storage to increase the reliability of grid operation. Here, a proton exchange membrane electrolyzer can produce H 2 and serves as a utility controllable load. The produced H 2 can then be stored and converted back into electricity, or mixed with natural gas, or used as transportation fuel, or chemical feedstock. This paper considers the perspective of the distribution system operator that operates the distributed energy resources on a standard IEEE 33-node distribution network considering the technical and physical constraints with the goal of minimizing total investment and operation cost. Different case studies, at very high PV penetrations are considered to show the challenges and path to net-zero emission energy production using H 2 energy. Sensitivity of utility PV costs and electrolyzer capital costs on producing H 2 at $\$1$ /kg are presented showing that the distribution network could produce 100% renewable electricity and H 2 could be produced at a cost of $\$1$ /kg by 2050 with conservative cost estimates and by 2030 with accelerated cost declines.

25 ENERGY STORAGE↗

High Energy Systems for Transforming CO 2 to Valuable Products (Final Report)

The objective of this project is to develop the Direct E-Beam Synthesis (DEBS) process that uses high-energy electron beams (E-Beam) to break chemical bonds. This allows the production of valuable chemicals, such as acetic acid, methanol, and carbon monoxide, at relatively low severity (pressure near one atmosphere and temperatures <150°C) from near-pure CO 2 captured from a pulverized coal-fired power plant and methane, imported as natural gas. Creating such valuable products will offset the cost of carbon capture and storage. Through this project, we have designed, constructed, and operated an E-Beam reactor to examine the feasibility of performing dry reforming reaction without a catalyst using only DEBS. We have verified the production of syngas with 1:1 H2:CO ratio and calculated that the energy cost for conversion is about 5.2 eV/molecule of product for dry reforming reaction which is similar to the energy cost for conversion using conventional thermochemical conversion but under significantly milder conditions (room temperature and atmospheric pressure). We have performed a technoeconomic analysis (TEA) to estimate the total capital requirement and the cost of production for a 99.4 MMSCFD syngas production plant via non-catalytic Direct E-Beam Synthesis (DEBS) technology utilizing a high-energy electron beam (E-Beam) accelerator. No assumption is made for syngas utilization downstream, and the incoming reactants are pure CO 2 from carbon capture (assumed to be at zero cost) and natural gas. The Total As-Spent Cost (TASC) was calculated to be $\$242.5$ million, resulting in a levelized cost of syngas (LCOS) of $\$175.84$/tonne (metric) at a natural gas price of $\$6.24$/MMBTU1. The cost of syngas is primarily determined by the price of natural gas. If the cost of the CO 2 feedstock is assumed to be non-zero, then the price of the CO 2 feed also heavily influences the levelized cost of syngas. The potential impact on the cost of electricity from syngas revenue is significant. Following DOE NETL’s guidance, a lifecycle analysis (LCA) was conducted to compare the cradle-to-gate life cycle emissions of GTI Energy’s novel Direct E-Beam Synthesis (DEBS) process that produces syngas via the reaction of methane and carbon dioxide to the emissions of a state-of-the-art Steam Methane Reforming (SMR) process that also produces syngas via the reaction of methane and steam. The DEBS process results in less GHG emissions than SMR (with CO product as the basis of comparison). openLCA was used for the LCA and the results show that the total global warming potential (GWP) of DEBS is 0.981 kg CO 2 e per kg CO product, while the SMR process has a global warming potential of 2.573 kg CO 2 e per kg CO product. The ratio of the GWP of the proposed product system to the comparison product system is 0.381. This percent change is 61.9% lower GWP than SMR.

20 FOSSIL-FUELED POWER PLANTS↗

Evolving Architectures and Considerations to address Distributed Energy Resources and Non-Wired Alternatives

The electric grid is in the beginning stage of a transformation, driven by a combination of shutdowns of coal-fired plants, commissioning of new natural-gas plants, and tremendous growth in energy supply from renewables such as wind, and solar. As utilities navigate this transformation, their progress is supported by advances in Operational Technologies (OT), and Informational Technologies (IT), such as automation, smart inverters, cloud computing, mobile computing, machine learning, big data analytics, which have the potential to enable advanced capabilities more efficiently and at a lower cost. This white paper focuses on the architectural considerations that will allow the industry to transition in a planned manner. It introduces and formalizes two architectural constructs –the data bus and the control bus. The data bus is responsible for carrying all non-operational models and information necessary to drive utility decisions. In contrast, the control bus is responsible for carrying all operational data and control actions taken at the local level, centralized level, or other levels in-between. The paper reviews those architectural considerations, their requirements and how they will evolve. This paper intends to provide a context for vendors, utilities, and their service providers to review and understand the changes that are coming and get ready for them.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utilization of Existing Pipelines in Hydrogen Transport: Literature Review Report

This report critically reviews the flow behavior of hydrogen-natural gas (H 2 -NG) mixtures in pipelines and examines the critical factors of hydrogen integration into existing natural gas infrastructure. It addresses the choking behavior characterized by velocity increase and pressure drop, as well as the effects of flow restrictions and pressure losses during hydrogen transport. Computational and analytical models are used to investigate these effects, and their effects on thermodynamic properties and system performance are evaluated. The study also reviews the energy efficiency and flow dynamics of hydrogen and methane-hydrogen mixtures and optimizes the hydrogen flow rate. In addition, the effects of these mixtures on the flow characteristics are discussed in detail, with special emphasis on the compressibility factor (z factor) and fluid properties based on equations of state for hydrogen-natural gas mixtures. The study also analyzes the mixture ratios and highlights the thermophysical properties, flow dynamics, and hydrogen-blended natural gas application potential. These investigations assess flow stability, material interactions, and operational feasibility of transporting hydrogen mixtures through natural gas pipelines, which contribute to developing sustainable and efficient energy systems.

08 HYDROGEN↗

Dehydration Membrane Reactor for Production of Valuable Chemicals from CO 2 and H 2

GTI Energy and partners have been developing a technology for production of liquefied petroleum gas (LPG) from carbon dioxide (CO 2 ) and hydrogen (H 2 ) using a novel catalytic membrane reactor. The reactor contains a bi-functional catalyst for methanol synthesis and LPG synthesis, resulting in LPG production in a single reactor. A transformational dehydration membrane is used to remove water in situ, shifting the thermodynamic equilibrium towards product formation. As a result, CO 2 conversion as high as 90.2% and LPG yield as high as 60.5% were obtained at 300°C and 20 bara in the membrane reactor, which significantly exceed the literature results of the traditional reactors

03 NATURAL GAS↗

Free-Piston Expander for Hydrogen Cooling

This final report details work done by GTI Energy, in partnership with University of Texas at Austin – Center for Electromechanics (UTCEM), Argonne National Laboratory (ANL), and Quantum Fuel Solutions (Quantum) to successfully design, fabricate, and test a linear free-piston hydrogen expander controlled by linear motors which also generates electrical power during the process.

03 NATURAL GAS↗

Modeling and Analysis of a Thermophotovoltaic Integrated Self-Powered Furnace

This work investigates the energy efficiency and carbon reduction potential of self-powered residential building heating equipment using a thermodynamic modeling approach. An integrated thermophotovoltaic power module and residential scale furnace system (40,000 Btu/h) were modeled and studied in detail to assess the influence of different design configurations on primary energy efficiency. Operational characteristics such as total power generation, electrical efficiency, and heat recovery were examined in a self-powered system configuration. A sensitivity analysis was conducted to determine the influence of the electric grid’s carbon dioxide footprint (carbon intensity) and the cost of electricity on the environmental, as well as the economic, benefit associated with the self-powered configuration. Compared with a traditional furnace powered by an electric grid at a carbon intensity of 0.5 kg CO 2eq /kWh EL , the self-powered furnace was shown to decrease the annual carbon dioxide emissions by approximately 550 kg (~75% reduction), while also saving more than USD 200 in utility expenses, annually. Additionally, the carbon emission reduction potential of blending different concentrations of hydrogen in natural gas fuel was also studied.

14 SOLAR ENERGY↗

Annual Technology Baseline: The 2024 Electricity Update

Consistent cost and performance data for various electricity generation technologies can be difficult to find and may change frequently for certain technologies. With the Annual Technology Baseline (ATB), the National Renewable Energy Laboratory annually provides an organized and centralized set of such cost and performance data. The ATB uses the best information from the Department of Energy national laboratories' energy analysts. The ATB has been reviewed by experts and it includes the following electricity generation and storage technologies: land-based wind, offshore wind, distributed wind, utility-scale solar photovoltaics (PV), commercial-scale solar PV, residential-scale solar PV, concentrating solar power, geothermal power, hydropower, utility-scale battery storage, commercial battery storage, residential battery storage, pumped storage hydropower, nuclear, coal, and natural gas. EIA data for conventional biopower are included for reference. This webinar presentation introduces the 2024 update to the ATB Electricity data and documentation.

battery storage↗

Module for Oxygenating Water without Generating Bubbles

A module that dissolves oxygen in water at concentrations approaching saturation, without generating bubbles of oxygen gas, has been developed as a prototype of improved oxygenators for water-disinfection and water-purification systems that utilize photocatalyzed redox reactions. Depending on the specific nature of a water-treatment system, it is desirable to prevent the formation of bubbles for one or more reasons: (1) Bubbles can remove some organic contaminants from the liquid phase to the gas phase, thereby introducing a gas-treatment problem that complicates the overall water-treatment problem; and/or (2) in some systems (e.g., those that must function in microgravity or in any orientation in normal Earth gravity), bubbles can interfere with the flow of the liquid phase. The present oxygenation module (see Figure 1) is a modified version of a commercial module that contains >100 hollow polypropylene fibers with a nominal pore size of 0.05 m and a total surface area of 0.5 m2. The module was originally designed for oxygenation in a bioreactor, with no water flowing around or inside the tubes. The modification, made to enable the use of the module to oxygenate flowing water, consisted mainly in the encapsulation of the fibers in a tube of Tygon polyvinyl chloride (PVC) with an inside diameter of 1 in. (approx.=25 mm). In operation, water is pumped along the insides of the hollow fibers and oxygen gas is supplied to the space outside the hollow tubes inside the PVC tube. In tests, the pressure drops of water and oxygen in the module were found to be close to zero at water-flow rates ranging up to 320 mL/min and oxygen-flow rates up to 27 mL/min. Under all test conditions, no bubbles were observed at the water outlet. In some tests, flow rates were chosen to obtain dissolved-oxygen concentrations between 25 and 31 parts per million (ppm) . approaching the saturation level of approx.=35 ppm at a temperature of 20 C and pressure of 1 atm (approx.=0.1 MPa). As one would expect, it was observed that the time needed to bring a flow of water from an initial low dissolved-oxygen concentration (e.g., 5 ppm) to a steady high dissolved-oxygen concentration at or near the saturation level depends on the rates of flow of both oxygen and water, among other things. Figure 2 shows the results of an experiment in which a greater flow of oxygen was used during the first few tens of minutes to bring the concentration up to approx.=25 ppm, then a lesser flow was used to maintain the concentration.

Gonzalez-Martin, Anuncia↗