An Adaptive Reference Scheme to Extend the Functional Range of Optical Backscatter Reflectometry in Extreme Environments

Optical frequency domain reflectometry (OFDR) measurements are performed by recording the interference pattern of light backscattered by density fluctuations or Bragg gratings along the length of an optical fiber. Changes in local temperature or strain in the fiber cause shifts in the backscattered light spectrum, which can be calibrated to the applied temperature or strain. Comparing the backscattered optical spectra from each reflection site with a reference (unstrained) spectrum allows for quantification of local spectral shifts. While mature OFDR-based technologies can provide high-precision spatially distributed measurements over kilometer lengths, the post-processing approaches used to recover spectral shifts from raw optical intensity data can limit the use of OFDR in harsh environments. This paper presents a novel approach to post-processing OFDR data which extends the usability of optical fibers exposed to harsh environments. This approach is the first to use the spectral shift quality, calculated for two OFDR measurements, to identify an appropriate reference scan from which the spectral shift can be determined. Here, three experimental data sets are used to test the algorithm: (1) an optical fiber heated to >950°C, (2) an aluminum-embedded optical fiber under strain from differential thermal expansion, and (3) an optical fiber exposed to a total neutron flux of 2×10 13 n/cm 2 /s over 40 hours in a nuclear test reactor. Results show that using a metric of quality to select an appropriate reference measurement extends the functional range of OFDR strain and temperature sensors. Furthermore, this algorithm can be applied to existing OFDR data.

47 OTHER INSTRUMENTATION↗

Report on ISR-1 High-Altitude Balloon Flight

To test small technologies at lower cost for space science applications, LANL has developed a small high altitude balloon payload that could, in the future, be regularly and inexpensively launched from LANL. A neutron detector, NEMO, was integrated to evaluate its performance in a space-like mixed-radiation environment and collect neutron data in the atmosphere. In collaboration with EES-14, a high-altitude balloon payload was launched from LANL Technical Area 51 on February 27, 2023 and April 17, 2023. For real-time geolocation, a SAM-M8Q M8 GNSS module was used to get position and time, and an Iridium RockBLOCK 9603 was used to communicate with the ground using the Iridium satellite fleet. These modules were all controlled using an Iteaduino Mega microcontroller board. Finally, a High Altitude Science Eagle Flight Computer with a temperature pressure sensor ran independently, writing data to an SD card. All of these modules were powered by a 5 mAh lithium polymer battery. The battery was attached to the bottom of the payload while the remaining electronics were embedded in the underside of the top of the payload. These modules were wired as seen in Figure 1-2. The Iteaduino Mega microcontroller board was programmed to use the RockBLOCK to send a message once every 10 minutes containing neutron and GPS data read off the NEMO and SAM M8Q, respectively. Once the message send attempt finished, the RockBLOCK would be slept for the rest of the 10 minute interval. The Eagle Flight Computer ran continuously throughout the flight, taking data every 6 seconds. The RockBLOCK message data was set up to be delivered from the Iridium satellite fleet to a website, where it was stored and parsed to create live maps and plots for analysis and balloon retrieval. The RockBLOCK message data was additionally configured to be sent to an email as a fail-safe. The payload was ground-tested successfully for over 50 hours, with multiple revisions occurring to best prepare for conditions at altitude and improve the software and firmware to fix any issues that cropped up with the data pipeline. Additional to the balloon payload, the flight had an attached iMet-4 radiosonde and Garmin T5 GPS Dog Collar. The radiosonde provided GPS and meteorological data. The T5 dog collar is used along with a Garmin Astro 430 to track the balloon at a range of up to 9 miles for retrieval. The balloon itself was initially a 1600 g meteorological balloon with an attached High Altitude Science parachute, both of which can be seen in Figure 1-3. After the first flight, the EES team swapped to a Rocketman parachute.

42 ENGINEERING↗

Cobalt ferrite nanoparticle intercalated carbon nanotubes for a nanomagnetic ultrasensitive sensor of Cr-VI in water

Nanocomposites of cobalt ferrite (CFO) magnetic nanoparticles intercalated on carbon nanotubes (CNTs) are evaluated as a nanomagnetic ultrasensitive sensor for the environmental toxin, hexavalent chromium (Cr-VI). Specifically, the structural and magnetic changes that accompany the infiltration of the CFO/CNTs by Cr-VI are presented. Extended x-ray absorption fine structure (EXAFS) shows that the atomic spacing within the CFO structure changes in the presence of Cr, suggesting that the Cr is incorporated into the nanoparticles. Vibrating sample magnetometry (VSM) reveals that CFO/CNTs composite infiltrated with Cr-VI have a 71% enhancement in saturation magnetization compared with the uninfiltrated CFO/CNTs, while small-angle neutron scattering (SANS) suggests that this magnetic enhancement is not associated with the nanoparticle lengthscales, but may arise from longer-ranged clusters. Both VSM and SANS clearly demonstrate that the Cr-doped CFO/CNTs are hysteretic with a net magnetization at remanence that is about 1/3 that of saturation, while this hysteresis is absent in the undoped CFO/CNTs. These magnetic differences at either remanence or saturation are promising for the magnetic detection of Cr-VI using CFO/CNTs sensors.

36 MATERIALS SCIENCE↗

Quality Assurance methodology for the ATLAS Inner Tracker strip sensor production

The production of the strip sensors for the ATLAS Inner Tracker (ITk) will start in 2020. Nearly 22,000 large area sensors will be produced over a period of about five years by Hamamatsu Photonics K.K. (HPK). The institutes involved in the sensor development and production are committed to deliver and maintain the highest quality sensors for the experiment. A Quality Assurance (QA) strategy has been prepared to be carried out during the whole production period. Once the process has been characterized as providing the required pre-irradiation specifications and the proper radiation hardness, the onus is on the manufacturer to rigidly stick to that qualified process. Still, sample testing with specific device-element structures and irradiation of devices should be implemented by the ITk sensor collaboration. A detailed irradiation and testing plan has been prepared by the ATLAS-ITk Collaboration, together with a newly designed test chip with specific structures to monitor different key technological and device parameters during the whole production. The tests and irradiations will be carried out on a sample basis. In order to have a practical methodology, samples from alternating batches will be sent for irradiations with protons, neutrons and gammas, and then tested in order to check that the characteristics remain within specifications. Here we present the detailed plan and the design and test methods for the structures in the test chip.

47 OTHER INSTRUMENTATION↗

Neutron detection performance of gallium nitride based semiconductors

Neutron detection is crucial for particle physics experiments, nuclear power, space and international security. Solid state neutron detectors are of great interest due to their superior mechanical robustness, smaller size and lower voltage operation compared to gas detectors. Gallium nitride (GaN), a mature wide bandgap optoelectronic and electronic semiconductor, is attracting research interest for neutron detection due to its radiation hardness and thermal stability. This work investigated thermal neutron scintillation detectors composed of GaN thin films with and without conversion layers or rare-earth doping. Intrinsic GaN-based neutron scintillators are demonstrated via the intrinsic 14 N(n, p) reaction, which has a small thermal neutron cross-section at low neutron energies, but is comparable to other reactions at high neutron energies (>1 MeV). Gamma discrimination is shown to be possible with pulse-height in intrinsic GaN-based scintillation detectors. Additionally, GaN-based scintillation detector with a 6 LiF neutron conversion layer and Gd-doped GaN detector are compared with intrinsic GaN detectors. These results indicate GaN scintillator is a suitable candidate neutron detector in high-flux applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrade of the gated laser entrance hole imager G-LEH-2 on the National Ignition Facility

A major upgrade has been implemented for the ns-gated laser entrance hole imager on the National Ignition Facility (NIF) to obtain high-quality data for Hohlraum physics study. In this upgrade, the single “Furi” hCMOS sensor (1024 × 448 pixel arrays with two-frame capability) is replaced with dual “Icarus” sensors (1024 × 512 pixel arrays with four-frame capability). Both types of sensors were developed by Sandia National Laboratories for high energy density physics experiments. With the new Icarus sensors, the new diagnostic provides twice the detection area with improved uniformity, wider temporal coverage, flexible timing setup, and greater sensitivity to soft x rays (<2 keV). These features, together with the fact that the diagnostic is radiation hardened and can be operated on the NIF for high neutron yield deuterium–triterium experiments, enable significantly greater return of data per experiment.

47 OTHER INSTRUMENTATION↗

Electron pulse-dilation diagnostic instruments

During the past decade, a number of diagnostic instruments have been developed that utilize electron pulse-dilation to achieve temporal resolution in the 5–30 ps range. These development efforts were motivated by the need for advanced diagnostics for high-energy density physics experiments around the world. The new instruments include single- and multi-frame gated imagers and non-imaging detectors that record continuous data streams. Electron pulse-dilation provides high-speed detection capability by converting incoming signals into a free electron cloud and manipulating the electron signal with electric and magnetic fields. In this paper we discuss design details and applications of these instruments along with issues and challenges associated with employing the electron pulse-dilation technique. Additionally, methods to characterize instrument performance and improve tolerance to gamma and neutron background radiation are discussed.

47 OTHER INSTRUMENTATION↗

Layout and performance of HPK prototype LGAD sensors for the High-Granularity Timing Detector

The High-Granularity Timing Detector is a detector proposed for the ATLAS Phase II upgrade. The detector, based on the Low-Gain Avalanche Detector (LGAD) technology, will cover the pseudo-rapidity region of 2.4 < |n| < 4.0 with two end caps on each side and a total area of 6.4 m 2 . The timing performance can be improved by implanting an internal gain layer that can produce signals with a fast rising edge. It significantly improves the signal-to-noise ratio. The required average timing resolution per track for a minimum ionizing particle is 30 ps at the start and 50 ps at the end of the HL-LHC operation. This is achieved with several layers of LGAD. The innermost region of the detector would accumulate a 1MeV neutron-equivalent fluence up to 2.5 10 15 n eq /cm 2 including a safety factor of 1.5 before being replaced during the scheduled shutdowns. The addition of this new detector is expected to play an important role in the mitigation of high pile-ups at the HL-LHC. The layout and performance of the various versions of LGAD prototypes produced by Hamamatsu (HPK) have been studied by the ATLAS Collaboration. The breakdown voltages, depletion voltages, inter-pad gaps, collected charge as well as the time resolution have been measured and the production yield of large size sensors has been evaluated.

47 OTHER INSTRUMENTATION↗

Neutron Transmutation Doped (NTD) germanium thermistors for sub-mm bolometer applications

Recent advances in the development of neutron transmutation doped (NTD) semiconductor thermistors fabricated from natural and controlled isotopic composition germanium are reported. The near ideal doping uniformity that can be achieved with the NTD process, the device simplicity of NTD Ge thermistors and the high performance of cooled junction field effect transistor preamplifiers led to the widespread acceptance of these thermal sensors in ground-based, airborne and spaceborne radio telescopes. These features made possible the development of efficient bolometer arrays.

Haller, E. E.↗

Deflection Measurements of a Thermally Simulated Nuclear Core Using a High-Resolution CCD-Camera

Space fission systems under consideration for near-term missions all use compact. fast-spectrum reactor cores. Reactor dimensional change with increasing temperature, which affects neutron leakage. is the dominant source of reactivity feedback in these systems. Accurately measuring core dimensional changes during realistic non-nuclear testing is therefore necessary in predicting the system nuclear equivalent behavior. This paper discusses one key technique being evaluated for measuring such changes. The proposed technique is to use a Charged Couple Device (CCD) sensor to obtain deformation readings of electrically heated prototypic reactor core geometry. This paper introduces a technique by which a single high spatial resolution CCD camera is used to measure core deformation in Real-Time (RT). Initial system checkout results are presented along with a discussion on how additional cameras could be used to achieve a three- dimensional deformation profile of the core during test.

Stanojev, B. J.↗

Design and calibration of an optically segmented single volume scatter camera for neutron imaging

The Optically Segmented Single Volume Scatter Camera (OS-SVSC) aims to image neutron sources for non-proliferation applications using the kinematic reconstruction of elastic double-scatter events. Our prototype system consists of 64 EJ-204 organic plastic scintillator bars, each measuring 5mm &#x00d7; 5mm &#x00d7; 200mm and individually wrapped in Teflon tape. The scintillator array is optically coupled to two silicon photomultiplier ArrayJ-60035 64P-PCB arrays, each comprised of 64 individual 6x6mm J-Series sensors arranged in an 8 &#x00d7; 8 array. We report on the design details, including component selections, mechanical design and assembly, and the electronics system. The described design leveraged existing off-the-shelf solutions to support the rapid development of a phase 1 prototype. Several valuable lessons were learned from component and system testing, including those related to the detector's mechanical structure and electrical crosstalk that we conclude originates in the commercial photodetector arrays and the associated custom breakout cards. We detail our calibration efforts, beginning with calibrations for the electronics, based on the IRS3D application-specific integrated circuits, and their associated timing resolutions, ranging from 3090ps. With electronics calibrations applied, energy and position calibrations were performed for a set of edge bars using 22 Na and 90 Sr, respectively, reporting an average resolution of 12.07±0.03mm for energy depositions between 900keVee and 1000keVee. We further demonstrate a position calibration method for the internal bars of the matrix using cosmic-ray muons as an alternative to emission sources that cannot easily access these bars, with an average measured resolution of 14.86+-0.29mm for depositions between 900keVee and 1000keVee. The coincident time resolution reported between pairs of bars measured up to 400ps from muon acquisitions. Energy and position calibration values measured with muons are consistent with those obtained using particle emission sources.

47 OTHER INSTRUMENTATION↗

Irradiation-induced Degradation of Surface Acoustic Wave Devices Fabricated on Bulk AlN

Here, recent work to evaluate the prospects for surface acoustic wave (SAW) devices fabricated on bulk aluminum nitride (AlN) for elevated temperature and radiation environments is reported and discussed. The design and fabrication of an array of SAW devices using commercial wafers is described, including the non-standard fabrication approach taken to overcome the stress-induced warpage of the 50 mm diameter AlN substrates. Radio frequency performance characterization of the SAW devices, with resonance frequencies ranging from 0.5 GHz to 1.5 GHz, is described. The linear temperature coefficient of frequency (TCF) near room temperature was measured and is compared to theoretical results from other investigators. Further, the effects of 8 MeV Al ion irradiation at 300°C and 500°C to damage levels of 0.01, 0.1 and 1 displacements per atom (dpa), as a proxy for neutron irradiation, was investigated. The ion irradiation damage was observed to decrease the SAW resonant frequency, and this effect is characterized and discussed. Significant degradation in the conductivity of the Ti/Al electrodes of the SAW devices was also observed and characterized. These experimental results provide a basis for further investigation of the prospects for development of SAW sensor devices in bulk AlN material for application in elevated temperature and radiation environments.

36 MATERIALS SCIENCE↗

Design of a Cryogenic Scintillation Neutrino Detector at the Spallation Neutron Source

We successfully verified in the following three aspects the feasibility of using a cryogenic scintillating crystal-based neutrino detector at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory, for the detection of low-mass dark matter particles and non-standard neutrino interactions (NSIs), as part of the detector R&D effort of the COHERENT experiment. First, we demonstrated the possibility of using silicon photomultipliers (SiPMs) at cryogenic temperatures to replace traditional photomultiplier tubes (PMTs) as light sensors. Second, we verified that the high light yield of undoped CsI crystals measured above 13 keVee at 77 K still holds down to 5.9 keVee. Third, we successfully measured nuclear quenching factor of undoped cryogenic CsI at the Triangle Universities Nuclear Laboratory with the help from our Duke collaborators. The first achievement resulted in a publication in European Physics Journal C. The second resulted in an arXiv pre-print, which is under journal review. The last one indicates that the performance of the proposed detector may be better than what was assumed in the literature. The analysis is in the final stage and will result in another journal publication. In addition, two graduate students involved in this project graduated with master’s degrees during the project period. Both decided to continue their research as PhD students. One open-source data analysis code package was created and is publicly available on GitHub. A set of tutorials about Monte Carlo simulation of radiation interacting with detectors were created on YouTube, receiving more than 100,000 views.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Final Report DE-SC0020773

The DOE/NNSA sought development of innovative portable neutron/x-ray cameras for imaging and, when coupled with a portable source, also for radiography. This project focused on developing such a device that promises to have excellent resolution, while also providing neutron/gamma separation. We developed an Application Specific Integrated Circuit (ASIC) to be employed in conjunction with existing sensor technologies and modern assembly techniques. The concepts developed were a combination of new novel techniques and an innovative implementation of existing methods boosted by technological advances in ASIC performance.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation sensitivity of silicon imaging sensors on missions to the outer planets.

Review of the results of an investigation of the magnitude of the degradation effects of radiation on the operating characteristics of camera tubes using silicon diode arrays in the space environment, and discussion of the radiation damage mechanisms concerned. The effects produced by bombardment of bare-silicon-diode arrays or vidicon tubes with 85-kV X rays, Cobalt 60 gamma rays, 1 MeV and 11 MeV electrons, 3 MeV and 142 MeV protons, and reactor neutrons are presented. Interference effects produced by radiation bombardment during operation of television tubes are investigated, and limiting fluxes of electrons and protons are given.

Brucker, G. J.↗

A review of radiation-induced damage to quantum dots

Quantum dots (QDs) are versatile nano structures that have applications in many fields of research and production, including biosensor technology, computing, photovoltaics, and optoelectronics. QDs have gained interest in the field of radiation detection because of their relative ease of production, tunable photoluminescence, and sensitivity to ionizing radiation. The photoluminescent properties of QDs diminish proportionally to prolonged ionizing radiation interactions, leading many groups to seek out these materials as potential candidates for the next generation of inexpensive, easily manufactured dosimetry and sensors. To use QDs in these applications, the mechanisms of radiation damage to the nanomaterial must be clearly understood and characterized. Herein, we review the study of ionizing radiation damage to QDs. First, the synthesis and properties of QDs are briefly discussed. Next, the radiation damage to QDs due to heavy charged particles, fast electrons, high energy photons, and neutrons are detailed. After this, experimental methods and modelling of QDs in radiation environments are examined. Lastly, future research directions are provided. The goal of this review is to aid in understanding the ionizing radiation effects on QD-based devices.

Snow, Jesse [University of Utah, Salt Lake City, U↗

Non-destructive structural characterization of graphite components using mechanical resonance and deep learning

As compared to conventional nuclear reactors, microreactors have the potential to significantly reduce construction timelines and capital costs, decreasing the barriers for advanced nuclear reactor technologies. However, the lower power output of these microreactors (typically < 20 MWe) creates challenging economics if operation and maintenance costs cannot be sufficiently reduced. The compact size of these designs presents an opportunity for comprehensive in-situ structural health monitoring to provide real-time feedback in order to reduce operational costs associated with maintenance and downtime. Many microreactor concepts use graphite for both in-core neutron moderation and as a structural material, which has typically required some form of periodic and laborious inspection. This report provides a description and assessment of recent work with graphite to couple acoustic-based experimental measurements and characterization with machine learning models to mature structural health monitoring capabilities and generate benefits for the nuclear microreactor industry. With resilient embedded sensors in development in other programs funded by the US Department of Energy’s Office of Nuclear Energy and elsewhere, the work described herein builds upon previously funded efforts to mature non-destructive testing technology that relates measured vibrational signatures to structural changes, using a combination of new experimental measurements and machine learning processing. Building on past successful demonstrations of predictive workflows to identify structural changes in a hexagonal stainless steel test article with excellent acoustic propagation, we first performed baseline characterization on graphite samples with canonical geometries to ensure compatibility and confidence in the applied techniques for a material with distinctly different mechanical properties. In contrast to efforts in previous years, we worked exclusively with unidirectional vibration data that is more comparable to those expected from the existing embedded sensor technologies which are suitable for deployment in a reactor setting. Established acoustic and modern machine-learning-based characterization approaches were applied to the resulting datasets from these simple geometries. Both approaches were found to be highly capable of detecting even small geometric irregularities amongst nominally identical samples. As such, we then moved to testing these approaches for detection of artificial local stress perturbations introduced into a more complex geometry: a hexagonal block with drilled holes. A main outcome of this work is that a generalizable ML workflow can be used to detect and predict the characteristics of small artificial anomalies in a graphite component with a relevant geometry. While this work was performed using surficial vibration data, we expect the approach to be flexible and viable for other monitoring scenarios, such as those with different arrangements or types of sensor arrays. As compared to previously funded efforts, an existing ML workflow based on neural networks was enhanced through the addition of recently developed Fourier neural operators. As applied to previously collected and new vibration datasets, prediction accuracies of anomaly characterizations were greatly improved with minimal added computational cost. As trained on small durations of vibration data (tens of seconds) collected over a realistic number of locations, the model was able to reliably determine the presence of a subtle stress anomaly and begin to provide location estimates. Such an approach is likely to be viable for more relevant reactor damage scenarios for graphite components, such as progressive crack growth or creep.

36 MATERIALS SCIENCE↗

Retractable Sensor for Reactor Experiments

This presentation is to orient a mechanical or nuclear engineering senior design team so that they can help solve an instrumentation problem found in high power test reactors. Test reactors such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory are used to irradiate nuclear fuels and materials to evaluate performance after high levels of exposure to a reactor in-pile environment. The purpose of the experiments is to determine property changes as the materials or fuels are bombarded with fast neutrons (and thermal (slow) neutrons as well). Typically, the irradiation must take place at a very specific temperature. Sometimes other parameters are monitored as well as properties such as creep, or gas composition, etc. However, the fast neutrons cause changes in not only the materials, but also in the transducers that are placed in the neutron flux, e.g., thermocouples or optical fibers. This task will be limited to considering temperature measurements. Thermocouples experience decalibration from not only the neutron flux, but also from the very high temperatures that are sometimes measured. Optical fibers darken in a neutron or gamma flux. However, it takes quite a few hours, or days for these changes to manifest. High power test reactors typically run at a constant power and so the temperature in an experiment is fairly stable over time. Because the changes are typically very slow, even a single temperature measurement per day, would provide 95% of a perfect data set. The basic concept of this effort is to push a very small diameter thermocouple or optical fiber into the location to be measured, leave it for 30 seconds or so for it to come to equilibrium, and transmit the signal, and then pull it up and away from the high neutron flux and high temperature region. The distance the thermocouple or fiber would need to move is on the order of 50 – 100 cm. By doing this, the thermocouple junction or optical fiber would spend only a few hours in the high flux/high temperature environment over the life of the irradiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗