Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Global lessons: a comparative analysis of nuclear gamification's impact in American and British students

The global nuclear skills shortage demands urgent educational investment, particularly for students aged 11–18. To help address this, we have introduced RAD Ratings, an interactive card game designed to improve the teaching of nuclear concepts to students, which includes subjects such as half-lives, types of radiation, and radionuclide applications. RAD Ratings has already been successfully piloted in the United Kingdom and in this paper, we present a comparison in selected American schools for the first time. Snapshot survey results show RAD Ratings improve interest in nuclear science and careers, offering insights into gamification’s potential to improve engagement across different geographic locations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

230Th/234U radiochronometry for uranium materials by alpha spectrometry for nuclear forensics analysis

We have developed an alpha spectrometry method for 230Th/234U radiochronometry to determine the model separation age for uranium materials. This method offers an alternative to the more commonly used, but significantly more resource intensive multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) while providing similar accuracy and precision. The development included radiochemical separation of uranium and thorium, calibration of the 232U tracer and the alpha spectrometry measurement. The method was validated by analyzing a certified reference material, CRM 125-A, which is a uranium oxide pellet assay, isotopic, and radiochronometric standard. The results were compared to those obtained by our routine MC-ICP-MS 230Th/234U radiochronometry analysis method to assess the performance parameters for alpha spectrometry compared to the state-of-the-art technique.

Macsik, Zsuzsanna [Los Alamos National Laboratory ↗

Imaging analysis of nuclear antiviral factors through direct detection of incoming adenovirus genome complexes

Recent studies involving several viral systems have highlighted the importance of cellular intrinsic defense mechanisms through nuclear antiviral proteins that restrict viral propagation. These factors include among others components of PML nuclear bodies, the nuclear DNA sensor IFI16, and a potential restriction factor PHF13/SPOC1. For several nuclear replicating DNA viruses, it was shown that these factors sense and target viral genomes immediately upon nuclear import. In contrast to the anticipated view, we recently found that incoming adenoviral genomes are not targeted by PML nuclear bodies. Here we further explored cellular responses against adenoviral infection by focusing on specific conditions as well as additional nuclear antiviral factors. In line with our previous findings, we show that neither interferon treatment nor the use of specific isoforms of PML nuclear body components results in co-localization between incoming adenoviral genomes and the subnuclear domains. Furthermore, our imaging analyses indicated that neither IFI16 nor PHF13/SPOC1 are likely to target incoming adenoviral genomes. Thus our findings suggest that incoming adenoviral genomes may be able to escape from a large repertoire of nuclear antiviral mechanisms, providing a rationale for the efficient initiation of lytic replication cycle. - Highlights: • Host nuclear antiviral factors were analyzed upon adenovirus genome delivery. • Interferon treatments fail to permit PML nuclear bodies to target adenoviral genomes. • Neither Sp100A nor B targets adenoviral genomes despite potentially opposite roles. • The nuclear DNA sensor IFI16 does not target incoming adenoviral genomes. • PHF13/SPOC1 targets neither incoming adenoviral genomes nor genome-bound protein VII.

60 APPLIED LIFE SCIENCES↗

Failure analysis of nuclear transient-tested UN tristructural isotropic fuel particles in a 3D printed SiC matrix

Fully ceramic microencapsulated fuel elements containing UN tristructural isotropic (TRISO) fuel particles within a 3D printed SiC matrix were subjected to transient testing with varying energy depositions. Detailed post-irradiation examinations were performed, including leaching in hot HNO3 and post-leaching X-ray computed tomography, to quantify the percentage of failed TRISO particles and crack propagation within the particles and surrounding fuel matrix. In parallel, detailed finite element analyses were performed for comparison with experimental findings and to better evaluate transient failure modes. The lowest transient energy deposition—which still exceeded bounding values for high-temperature gas-cooled reactor applications—resulted in no detectable TRISO particle failures or matrix cracking, which was consistent with the simulations. Simulations of the higher-energy transients for which significant TRISO particle failure was expected were generally able to reproduce the transient temperatures and matrix cracking. Thus, the TRISO particle failures were explained based on the effects of local SiC matrix thickness and porosity. Results generally confirmed the high strength of the additively manufactured SiC matrix but also affirmed the need for a modified UN TRISO architecture to prevent SiC matrix cracks from propagating through TRISO layers. This unique failure mode has not historically been considered for TRISO fuels contained in weaker graphite matrices.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Application of the Uranium–Helium Chronometer to the Analysis of Nuclear Forensic Materials

Radiochronometers are used to constrain the manufacturing and processing history of actinide materials for nuclear forensic investigations. This paper describes here U–He ages and He diffusion kinetics obtained from a metallic, highly enriched uranium sample. The average U–He age is 8% older than the known casting date, which indicates that excess He is present and is likely due to incomplete degassing of pre-existing He during the casting process. Although the U–He age is older than expected, the accuracy is comparable to other chronometers that have been applied to this material. Diffusion kinetics obtained from the uranium metal indicate that He is quantitatively retained under plausible storage conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo Solutions for Selected Problems in Gamma-Ray Spectrometry and Nuclear Activation Analysis

A comprehensive calibration of gamma-ray spectrometers cannot be obtained purely on experimental basis. Problems like self-attenuation effects, coincidence-summing effects and non-uniform source distribution (resulting e.g. from neutron self-shielding in NAA) can be efficiently solved by Monte Carlo simulation. The application of the GESPECOR code to these problems is presented and the associated uncertainty is discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fault detection and analysis in nuclear research facility using artificial intelligence methods

In this article, an online detection of transducer and actuator condition is discussed. A case study is on the reading of area radiation monitor (ARM) installed at the chimney of PUSPATI TRIGA nuclear reactor building, located at Bangi, Malaysia. There are at least five categories of abnormal ARM reading that could happen during the transducer failure, namely either the reading becomes very high, or very low/ zero, or with high fluctuation and noise. Moreover, the reading may be significantly higher or significantly lower as compared to the normal reading. An artificial neural network (ANN) and adaptive neuro-fuzzy inference system (ANFIS) are good methods for modeling this plant dynamics. The failure of equipment is based on ARM reading so it is then to compare with the estimated ARM data from ANN/ ANFIS function. The failure categories in either ‘yes’ or ‘no’ state are obtained from a comparison between the actual online data and the estimated output from ANN/ ANFIS function. It is found that this system design can correctly report the condition of ARM equipment in a simulated environment and later be implemented for online monitoring. This approach can also be extended to other transducers, such as the temperature profile of reactor core and also to include other critical actuator conditions such as the valves and pumps in the reactor facility provided that the failure symptoms are clearly defined.

42 ENGINEERING↗

Image processing analysis of nuclear track parameters for CR-39 detector irradiated by thermal neutron

CR-39 detector which covered with boric acid (H{sub 3}Bo{sub 3}) pellet was irradiated by thermal neutrons from ({sup 241}Am - {sup 9}Be) source with activity 12Ci and neutron flux 10{sup 5} n. cm{sup −2}. s{sup −1}. The irradiation times -T{sub D} for detector were 4h, 8h, 16h and 24h. Chemical etching solution for detector was sodium hydroxide NaOH, 6.25N with 45 min etching time and 60 C° temperature. Images of CR-39 detector after chemical etching were taken from digital camera which connected from optical microscope. MATLAB software version 7.0 was used to image processing. The outputs of image processing of MATLAB software were analyzed and found the following relationships: (a) The irradiation time -T{sub D} has behavior linear relationships with following nuclear track parameters: i) total track number - N{sub T} ii) maximum track number - MRD (relative to track diameter - D{sub T}) at response region range 2.5 µm to 4 µm iii) maximum track number - M{sub D} (without depending on track diameter - D{sub T}). (b) The irradiation time -T{sub D} has behavior logarithmic relationship with maximum track number - M{sub A} (without depending on track area - A{sub T}). The image processing technique principally track diameter - D{sub T} can be take into account to classification of α-particle emitters, In addition to the contribution of these technique in preparation of nano- filters and nano-membrane in nanotechnology fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

KINEMATIC ANALYSIS OF NUCLEAR SPIRALS: FEEDING THE BLACK HOLE IN NGC 1097

We present a harmonic expansion of the observed line-of-sight velocity field as a method to recover and investigate spiral structures in the nuclear regions of galaxies. We apply it to the emission-line velocity field within the circumnuclear star-forming ring of NGC 1097, obtained with the GMOS-IFU spectrograph. The radial variation of the third harmonic terms is well described by a logarithmic spiral, from which we interpret that the gravitational potential is weakly perturbed by a two-arm spiral density wave with an inferred pitch angle of 52{sup 0} {+-} 4{sup 0}. This interpretation predicts a two-arm spiral distortion in the surface brightness, as hinted by the dust structures in central images of NGC 1097, and predicts a combined one-arm and three-arm spiral structure in the velocity field, as revealed in the non-circular motions of the ionized gas. Next, we use a simple spiral perturbation model to constrain the fraction of the measured non-circular motions that is due to radial inflow. We combine the resulting inflow velocity with the gas density in the spiral arms, inferred from emission-line ratios, to estimate the mass inflow rate as a function of radius, which reaches about 0.011 M{sub sun} yr{sup -1} at a distance of 70 pc from the center. This value corresponds to a fraction of about 4.2 x 10{sup -3} of the Eddington mass accretion rate onto the central black hole in this LINER/Seyfert1 galaxy. We conclude that the line-of-sight velocity can not only provide a cleaner view of nuclear spirals than the associated dust, but that the presented method also allows the quantitative study of these possibly important links in fueling the centers of galaxies, including providing a constraint on the mass inflow rate as a function of radius.

79 ASTRONOMY AND ASTROPHYSICS↗

Error analysis in nuclear density functional theory

Nuclear density functional theory (DFT) is the only microscopic, global approach to the structure of atomic nuclei. It is used in numerous applications, from determining the limits of stability to gaining a deep understanding of the formation of elements in the Universe or the mechanisms that power stars and reactors. The predictive power of the theory depends on the amount of physics embedded in the energy density functional as well as on efficient ways to determine a small number of free parameters and solve the DFT equations. In this article, we discuss the various sources of uncertainties and errors encountered in DFT and possible methods to quantify these uncertainties in a rigorous manner.

Schunck, Nicolas↗