Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear radiation detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

The EXO-200 detector, part II: auxiliary systems

The EXO-200 experiment searched for neutrinoless double-beta decay of 136 Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. Here, this paper describes the design and performance of the various support systems necessary for detector operation, including cryogenics, xenon handling, and controls. Novel features of the system were driven by the need to protect the thin-walled detector chamber containing the liquid xenon, to achieve high chemical purity of the Xe, and to maintain thermal uniformity across the detector.

47 OTHER INSTRUMENTATION↗

Reconstruction of neutrino events in the Accelerator Neutrino Neutron Interaction Experiment. Part I

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) was designed to reconstruct neutrino events from the Fermilab Booster Neutrino Beam (BNB) with the parallel goals of measuring neutron production in interactions with oxygen and serving as a testbed for new technology. The ANNIE detector consists of a 26-ton water Cherenkov target tank instrumented with conventional photomultiplier tubes (PMTs), a downstream tracking muon spectrometer, and an upstream double wall of plastic scintillator to serve to veto charged particles incoming from neutrino events that occur upstream of the experimental setup. ANNIE has also deployed multiple Large-Area Picosecond PhotoDetectors (LAPPDs) and a test vessel of water-based liquid scintillator (WbLS). This paper describes the event reconstruction performance of the detector before implementation of these novel technologies, which will serve as a baseline against which their impact can be measured. That said, even the techniques used for event reconstruction using only the conventional PMT array and muon spectrometer are significantly different than those used in other water Cherenkov detectors due to the small size of ANNIE (which makes nanosecond-scale timing not as useful as in a large detector) and the availability of reconstruction information from the tracking muon spectrometer. We demonstrate that combining the information from these two elements into a single fit using only pattern recognition yields a muon vertex uncertainty of 60 cm, a directional uncertainty of 13.2 degrees, and energy reconstruction uncertainty of about 10% for BNB muon neutrino Charged Current Zero Pion (CC0π) events.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ECCE sensitivity studies for single hadron transverse single spin asymmetry measurements

Here, we performed feasibility studies for various single transverse spin measurements that are related to the Sivers effect, transversity and the tensor charge, and the Collins fragmentation function. The processes studied include semi-inclusive deep inelastic scattering (SIDIS) where single hadrons (pions and kaons) were detected in addition to the scattered DIS lepton. The data were obtained in pythia6 and geant4 simulated e+p collisions at 18 GeV on 275 GeV, 18 on 100, 10 on 100, and 5 on 41 that use the ECCE detector configuration. Typical DIS kinematics were selected, most notably Q 2 >1 GeV 2 , and cover the x range from 10 -4 to 1. The single spin asymmetries were extracted as a function of x and Q 2 , as well as the semi-inclusive variables z, which corresponds to the momentum fraction the detected hadron carries relative to the struck parton, and P T , which corresponds to the transverse momentum of the detected hadron relative to the virtual photon. They are obtained in azimuthal moments in combinations of the azimuthal angles of the hadron transverse momentum and transverse spin of the nucleon relative to the lepton scattering plane. In order to extract asymmetries, the initially unpolarized MonteCarlo was re-weighted in the true kinematic variables, hadron types and parton flavors based on global fits of fixed target SIDIS experiments and e + e – annihilation data. The expected statistical precision of such measurements is extrapolated to 10 fb –1 and potential systematic uncertainties are approximated given the deviations between true and reconstructed yields. Similar neutron information is obtained by comparing the ECCE e+p pseudo-data with the same from the EIC Yellow Report and scaling the corresponding Yellow Report e+ 3 He pseudo-data uncertainties accordingly. The impact on the knowledge of the Sivers functions, transversity and tensor charges, and the Collins function has then been evaluated in the same phenomenological extractions as in the Yellow Report. Finally, the impact is found to be comparable to that obtained with the parametrized Yellow Report detector and shows that the ECCE detector configuration can fulfill the physics goals on these quantities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Event-by-event direction reconstruction of solar neutrinos in a high light-yield liquid scintillator

The direction of individual B 8 solar neutrinos has been reconstructed using the SNO + liquid scintillator detector. Prompt, directional Cherenkov light was separated from the slower, isotropic scintillation light using time information, and a maximum likelihood method was used to reconstruct the direction of individual scattered electrons. A clear directional signal was observed, correlated with the solar angle. The observation was aided by a period of low primary fluor concentration that resulted in a slower scintillator decay time. This is the first time that event-by-event direction reconstruction in high light-yield liquid scintillator has been demonstrated in a large-scale detector. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of neutron-proton capture in the $\mathrmSNO+ water phase

The SNO+ experiment collected data as a low-threshold water Cherenkov detector from September 2017 to July 2019. Measurements of the 2.2-MeV γ 's produced by neutron capture on hydrogen were made using an Am-Be calibration source, for which a large fraction of emitted neutrons are produced simultaneously with a 4.4-MeV γ. Analysis of the delayed coincidence between the 4.4-MeV γ and the 2.2-MeV capture γ revealed a neutron detection efficiency that is centered around 50% and varies at the level of 1% across the inner region of the detector, which to our knowledge is the highest efficiency achieved among pure water Cherenkov detectors. Finally, in addition, the neutron capture time constant was measured and converted to a thermal neutron-proton capture cross section of $336.3^{+1.2}_{-1.5}$ mb .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ultra-Fast 4H-SiC LGAD With Etched Termination and Field Plate

The design, fabrication, and demonstration of a novel Silicon Carbide Low Gain Avalanche Detector (4HSiC LGAD), exhibiting an ultra-fast time response and excellent time resolution, are reported. Here, the use of field plates is proposed to suppress the high electric field caused by the negative bevel-etched angle in 4H-SiC LGADs based on TCAD simulations. Experimental measurements confirm that the field plate significantly increases the breakdown voltage of the 4H-SiC LGADs. Gain and time resolution are measured by using the ultraviolet transient current technique (UV-TCT) showing that 4H-SiC LGADs possess excellent timing performance, with a time resolution better than 35 ps for the injected laser signal with single minimum ionizing particle (MIP) charges generation at room temperature. Additionally, the gain suppression effect in a 4H-SiC LGAD is observed for the first time.

43 PARTICLE ACCELERATORS↗

Mitigation of backgrounds from cosmogenic 137 Xe in xenon gas experiments using 3 He neutron capture

136 Xe is used as the target medium for many experiments searching for 0νββ. Despite underground operation, cosmic muons that reach the laboratory can produce spallation neutrons causing activation of detector materials. A potential background that is difficult to veto using muon tagging comes in the form of 137 Xe created by the capture of neutrons on 136 Xe. This isotope decays via beta decay with a half-life of 3.8 minutes and a Q β of ~4.16 MeV. This work proposes and explores the concept of adding a small percentage of 3 He to xenon as a means to capture thermal neutrons and reduce the number of activations in the detector volume. When using this technique we find the contamination from 137 Xe activation can be reduced to negligible levels in tonne and multi-tonne scale high pressure gas xenon neutrinoless double beta decay experiments running at any depth in an underground laboratory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for the weak decay ψ (3686) → $Λ^{+}_{c}$ $\overline{Σ}$ - + c.c. *

Using (448.1 ± 2.9) x 10 6 ψ (3686) events collected with the BESIII detector, we perform the first search for the weak baryonic decay ψ (3686) → $Λ^{+}_{c}$ $\overline{Σ}$ - + c.c. . The analysis procedure is optimized using a blinded method. No significant signal is observed, and the upper limit on the branching fraction ($\mathcal{B}$) of ψ (3686) → $Λ^{+}_{c}$ $\overline{Σ}$ - + c.c. is set as 1.4 x 10 -5 at the 90% confidence level.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Observations of the Cabibbo-Suppressed decays $Λ^{+}_{c}$ → $\mathcal{n}$$π$ + $π$ 0 , $\mathcal{n}$$π$ + $π$ - $π$ + and the Cabibbo-Favored decay $Λ^{+}_{c}$ → $\mathcal{n}$$K$ - $π$ + $π$ + *

Using electron-positron annihilation data samples corresponding to an integrated luminosity of 4.5 fb -1 , collected by the BESIII detector in the energy region between $4599.53$ $MeV$ and $4698.82$ $MeV$ we report the first observations of the Cabibbo-suppressed decays $Λ^{+}_{c}$ → $\mathcal{n}$$π$ + $π$ 0 , $Λ^{+}_{c}$ → $\mathcal{n}$$π$ + $π$ - $π$ + , and the Cabibbo-favored decay $Λ^{+}_{c}$ → $\mathcal{n}$$K$ - $π$ + $π$ + with statistical significances of $7.9σ$, $7.8σ$, and Misplaced &, respectively. The branching fractions of these decays are measured to be $\mathcal{B}$($Λ^{+}_{c}$ → $\mathcal{n}$$π$ + $π$ 0 ) = ($0.64 ± 0.09 ± 0.02$)%, $\mathcal{B}$($Λ^{+}_{c}$ → $\mathcal{n}$$π$ + $π$ - $π$ + ) = ($0.45 ± 0.07 ± 0.03$)%, and $\mathcal{B}$ $Λ^{+}_{c}$ → $\mathcal{n}$$K$ - $π$ + $π$ + ) = ($1.90 ± 0.08 ± 0.09$)% where the first uncertainties are statistical and the second are systematic. We find that the branching fraction of the decay $Λ^{+}_{c}$ → $\mathcal{n}$$π$ + $π$ 0 is about one order of magnitude higher than that of $Λ^{+}_{c}$ → $\mathcal{n}$ $π$ + .

$Λ^{+}_{c}$ baryon↗

Improving Fission Products at CARIBU: Near Field Detection (Q3/FY20 Quarterly Progress Report)

Following the report from last quarter where we reported the experimental procedures, data acquisition and filtering process for the beta decay of 156 Eu, in the past quarter we have worked on establishing the efficiency for detecting the radiation emitted from this isotope with simulations of the HPGe detector and we have started investigating the beta detector energy deposition spectra.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Test of nuclear decay rate variation due to an antineutrino flux

Unexplained variations of the decay rate parameter for weak interaction decays such as β ± decay, electron capture, as well as strong interaction α decay have been reported. Because these variations have been presented by a number of groups, at various locations, using various types of detectors, different isotopes, and over extended periods of time, some researchers have interpreted the source of these variations as not from ambient environmental factors such as temperature, pressure, and humidity but via an unexplained fundamental interaction. The state of decay rate parameter variations experiments is reviewed, and the reported results are placed into a common comparable context by defining a phenomenological cross section. After that we make decay parameter measurements as a function of time at the level of 10 -5 in the presences of an antineutrino flux with an on-off cycle time of ≈ 30 days. This level of precision requires a detailed understanding of both systematic and statistical errors; otherwise, systematic errors in the measurement may mimic the decay events of fundamental interactions. The experiment searched for variation of the $^{54}_{25}$Mn, e - capture decay rate parameter and $^{137}_{55}$Cs, β - decay rate parameter both to a level of precision of 1 part in ≈10 5 by comparing the difference between the decay rate in the presence of an antineutrino flux ≈ 3 x 10 12 $\bar{ν}$ cm -2 s -1 and no flux measurements. The experiment was located 6.53 m from the reactor core of the High Flux Isotope Reactor at the Oak Ridge National Laboratory. Two weak interaction decays, one via electron capture and the other via β - decay, were selected because the final state and the time reverse state each contain a neutrino and antineutrino, covering arguments that the antineutrino flux may interact differently or not at all in one of the cases. The $\gamma$ spectra from both decays were collected and analyzed independently. The measured variation in the decay rate parameters are found to be δλ/λ =(0.034 ± 1.38) x10 -5 for $^{54}_{25}$Mn and δλ/λ =(0.67±1.56) x10 -5 for $^{137}_{55}$Cs. These results are consistent with no measurable decay rate parameter variation due to an antineutrino flux, yielding a 68% confidence level upper limit sensitivity for $^{54}_{25}$Mn δλ/λ ≤ 1.31 x 10 -5 or σ ≤ 1.29 x10 -25 cm 2 in cross section and for $^{137}_{55}$Cs δλ/λ ≤ 2.23 x 10 -5 or σ ≤ 5.69 x10 -27 cm 2 . The cross-section upper limit obtained in these null or no observable effect measurements are ≈ 10 4 times more sensitive than past experiments reporting positive results in 54 Mn and 137 Cs. . .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A novel integrated time-resolved array avalanche photodiode detection system for nuclear resonant scattering measurements

Here, the nuclear resonant scattering (NRS) experiment requires photon-counting detectors with high time resolution, short dead time, large dynamic range, low noise, and large detection area. An 8-channel avalanche photodiode (APD) array detector system with high integrity, flexibility, and reliability has been developed to adapt to the demands of NRS experiments. The detector system mainly consists of four key parts: (i) an array-APD sensor, (ii) 8-channel integrated fast preamplifiers, (iii) the time-to-digital converter readout electronics, and (iv) a data acquisition system and EPICS support software. Remarkably, the system exhibits a time resolution of better than 500 ps and has a sufficiently low noise level, allowing for the lowest detection energy threshold of 4 keV. The performance of the new array-APD system as well as its real application in nuclear forward scattering (NFS) and nuclear resonant inelastic x-ray scattering (NRIXS) experiments was tested in two synchrotron facilities. With the new system, the NFS signal very close to the prompt electronic scattering signal can be extracted. Thanks to the customized EPICS-areaDetector-based control software, NRIXS spectra can be readily measured with time and energy information of the NRIXS signal stored in the raw data, which is promising for developing NRIXS data analysis in the time domain. The array-APD detector can be deployed for nuclear resonant scattering experiments at various synchrotron radiation facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Luminosities and energies of e + e - collision data taken between $\sqrt{s}$=4.61 GeV and 4.95 GeV at BESIII*

From December 2019 to June 2021, the BESIII experiment collected approximately 5.85 fb -1 of data at center-of-mass energies between 4.61 and 4.95 GeV. This is the highest collision energy BEPCII has reached to date. The accumulated e + e - annihilation data samples are useful for studying charmonium(-like) states and charmed-hadron decays. By adopting a novel method of analyzing the production of $Λ^{+}_{c}$ $\overline{Λ}$ $^{-}_{c}$ pairs in e + e - annihilation, the center-of-mass energies are measured with a precision of ~0.6 MeV. Integrated luminosities are measured with a precision of better than 1% by analyzing the events of large-angle Bhabha scattering. These measurements provide important inputs to analyses based on these data samples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Discrimination of electronic recoils from nuclear recoils in two-phase xenon time projection chambers

We present a comprehensive analysis of electronic recoil vs. nuclear recoil discrimination in liquid/gas xenon time projection chambers, using calibration data from the 2013 and 2014-16 runs of the Large Underground Xenon (LUX) experiment. We observe strong charge-to-light discrimination enhancement with increased event energy. For events with S1 = 120 detected photons, i.e. equivalent to a nuclear recoil energy of ~100 keV, we observe an electronic recoil background acceptance of <10 –5 at a nuclear recoil signal acceptance of 50%. We also observe modest electric field dependence of the discrimination power, which peaks at a field of around 300 V/cm over the range of fields explored in this study (50-500 V/cm). In the WIMP search region of S1 = 1-80 phd, the minimum electronic recoil leakage we observe is (7.3 ± 0.6) 10 –4 , which is obtained for a drift field of 240-290 V/cm. Pulse shape discrimination is utilized to improve our results, and we find that, at low energies and low fields, there is an additional reduction in background leakage by a factor of up to 3. We develop an empirical model for recombination fluctuations which, when used alongside the Noble Element Scintillation Technique (NEST) simulation package, correctly reproduces the skewness of the electronic recoil data. We use this updated simulation to study the width of the electronic recoil band, finding that its dominant contribution comes from electron-ion recombination fluctuations, followed in magnitude of contribution by fluctuations in the S1 signal, fluctuations in the S2 signal, and fluctuations in the total number of quanta produced for a given energy deposition.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗