Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical fiber sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Reduction of Iron (III) Oxide in Microwaves Toward Gasification Studies

The purpose of this study is to reduce hematite (Fe2O3) using hydrogen (H2), carbon monoxide (CO), and methane (CH4) gases using microwave irradiation. Conventional temperature programmed reduction of iron phase transformation under H2, CO, and CH4 agree with the literature. Furthermore, the activation energy for the iron phase transformation in a conventional reactor was in the order of H2>CO>CH4, suggesting that CH4 was the best reductant to initiate the reduction at a much lower temperature than CO, and CO was significantly better than H2 atmosphere. Due to the uneven temperature distribution, the apparent activation energy of microwave reduction under H2 was approximately 1/4th when compared to the conventional reduction in H2. X-ray diffraction (XRD) analysis showed a mixed oxide phase in microwave reduction as opposed to the clear phase transformation in conventional studies. To combat the temperature measurement issues in microwave studies, fiber optic sensors and Forward Looking InfraRed (FLIR) sensors were used to acquire the actual temperature distribution in the catalyst bed. Therefore, a reasonably accurate activation energy estimation was achieved in the catalyst bed. Combining these with the characterization and quantification of the different iron phases in microwave reduction will provide a blueprint for future microwave-assisted gasification studies.

Aireddy, Divakar Reddy↗

Multi-Parameter Optical Fiber for Distributed Sensing of Humidity, CH4, CO2, and Corrosion

This work describes the use of the optical fiber sensor (OFS) for successful monitoring of humidity, CH4, and CO2 based on the strain produced along the single-mode fiber (SMF) sensor. This is enabled by absorption of H2O/gases onto the commercially available polyacrylate coated jacketed portion of the fiber resulting in a change in strain. Under equilibrium, a differential microstrain was observed along the jacketed portion of the SMF with N2, CH4, and CO2 at different relative humidity (RH) conditions. The strain response of the SMF under various mixed gas composition and different RH conditions were also measured and made calibration curves accordingly. Linear regression and principal component analysis of the strain datasets provided deconvolution of the impact of strain from H2O, N2, CH4, and CO2. Additionally, modified OFS comprised of the Fe coated fiber section was employed to monitor corrosion based on the increase in backscattered intensity amplitude of the light being passed once corrosion of Fe occurs. Also, corrosion of Fe was studied under soil by installing the fiber in soil with protective measures which would prevent the sensor being mechanically disturbed or broken during installation. The corrosion rates were studied by monitoring the rate at which the intensity of backscattered light amplitude attains a steady state value when complete corrosion of Fe with a specific coating thickness occurs.

Mainali, Badri↗

Main Shaft Bending Moment Analysis for a Gamesa G97 2-MW Wind Turbine

In a collaborative project between Siemens Gamesa Renewable Energy and the National Renewable Energy Laboratory (NREL), a cost-effective method to measure dynamic main shaft torque and the influence of non-torque loads was applied to the gearbox of the Gamesa G97 2-megawatt (MW) wind turbine at the NREL Flatirons Campus and verified through a field test campaign that took place in 2023. The method involved the installation of fiber-optic sensors on the ring gear of the gearbox. Additionally, traditional strain gauges and a rotary encoder were installed on the main shaft to measure mechanical torque and orthogonal bending moments. We compare the measured total main shaft bending moments from the field test campaign to those predicted by an updated OpenFAST model of the G97 wind turbine for similar environmental conditions. We also assessed the sensitivity of the predicted bending moment to varying levels of turbulence intensity, shear exponent, and yaw error.

17 WIND ENERGY↗

SATS Enhanced Capabilities and Demonstration of Improved Ramp Rates for In-Cell Testing

This report presents the development of the second-generation Severe Accident Test Station, referred to as SATS 2.0. SATS 2.0 represents a major advancement in addressing critical research needs for the United States nuclear industry, particularly in relation to fuel fragmentation, relocation, and dispersal (FFRD) concerns associated with the nuclear industry’s goal to extend fuel burnup beyond a peak rod average of 62 GWd/tU. The central objective of SATS 2.0 was the deployment a new furnace capable of achieving heating rates up to 100°C/s. This achievement addresses critical capability gaps, enabling assessment of prioritized research objectives established by the Electric Power Research Institute’s (EPRI) Collaborative Research on Advanced Fuel Technologies (CRAFT) working group. These research objectives are directly related to high-burnup loss-of-coolant accident (LOCA) conditions and the effects of prolonged exposure to elevated temperatures, both of which are crucial to enhancing nuclear safety and efficiency. The SATS 2.0 system builds upon prior experience with the original SATS system, which focused on evaluating accident-tolerant fuel (ATF) cladding concepts during accident conditions. However, the new system not only expands upon prior core capabilities by achieving higher heating rates with a better furnace but also plans to incorporate novel auxiliary systems to create a versatile platform for addressing current research needs. For example, a system was developed for the quantification and characterization of fission gas released during high-temperature transients. Additionally, in situ measurement capabilities were developed, such as digital image correlation which enabled the real-time capture of strain related to balloon and burst events and fiber-optic sensors that allowed for high-fidelity characterization of temperature gradients. Demonstration tests of the new 12-lamp furnace achieved heating rates up to 120°C/s. Notably, SATS 2.0 demonstrated its capacity to simulate LOCA burst tests at different pressures, yielding burst data that align with historical empirical models. Moreover, the system exhibited its capability to simulate complex conditions observed in anticipated operational occurrences, while effectively mitigating temperature overshoots. These accomplishments mark significant progress toward overcoming FFRD challenges and advancing the United States nuclear industry's safety basis and technical capabilities for extended burnup.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Initial Feasibility Assessment and Broader Strategy Development for Fiber Integration via Advanced Manufacturing

Structural health monitoring is critical for ensuring the operational safety and cost-competitiveness of the developing advanced reactor designs. The extreme operational envelopes of these advanced architectures, having operating temperatures ranging 400°C–1,000°C and heightened displacement damage doses, render conventional commercially available piezoelectric transducers and resistive strain gauges unviable. Optical fiber sensors present an attractive solution for advanced radiation-hardened instrumentation due to their high thermal stability and distributed sensing capabilities. However, their deployment in embedded applications can be hindered by the severe thermomechanical strain driven by the coefficient of thermal expansion mismatch between fused silica glass and structural metal alloys like stainless steel (e.g., SS316L).

36 MATERIALS SCIENCE↗

Large Language Model for Validation, Optical Calibration, and Learning (VOCAL) Distributed Temperature Sensing Interface

Distributed temperature sensing (DTS) using fiber optic sensors (FOS) offers a promising method for temperature measurements in advanced reactors, such as sodium fast reactors and molten salt cooled reactors. To support the calibration and validation of DTS measurements, Argonne National Laboratory developed the Validation, Optical Calibration, and Learning (VOCAL) software package. This report describes the integration of a local large language model (LLM) with a retrieval-augmented generation (RAG) system into the VOCAL interface to serve as an interactive user assistant. The LLM framework enhances the VOCAL platform’s accessibility to users by explaining interface components, clarifying inputs and outputs, and answering user queries dynamically in real-time. The accuracy of the LLM assistant performance was evaluated with 20 queries regarding the interface and its parameters using experimental data from the Thermal Hydraulic Experimental Test Article (THETA) facility. Results demonstrate that the LLM achieved a 95% accuracy rate, with a BERTScore of 0.8816 and SBERT value of 0.7417. Furthermore, validation of the RAG system within the LLM framework showed optimal accuracy with k-values between 1 and 2 using the k-refinement convergence test. The prompt perturbation analysis demonstrated good initial consistency for the RAG system, exhibiting the highest accuracy under punctuation variations and the greatest sensitivity under query reordering. Notably, the model’s errors were limited to data retrieval failures rather than factual hallucinations, reinforcing its baseline reliability. The integration of LLM provides a highly accurate, userfriendly enhancement to the VOCAL platform without disrupting its core computational capabilities for FOS calibration and validation.

Hong, Evan↗

Multi-Parameter Optical Fiber Sensing of Humidity, CH4, CO2, and Corrosion

In this work, the previously demonstrated capability of the optical fiber sensor (OFS) for successful monitoring of humidity has been extended to monitor the humidity, CH4, and CO2 with different gas composition based on the strain produced along the single mode fiber (SMF) sensor. This is enabled by absorption of H2O/gases on to the commercially available polyacrylate coated jacketed portion of the fiber resulting a change in strain. Under equilibrium, a differential microstrain was observed along the jacketed portion of the SMF with N2, CH4, and CO2 at different humidity conditions, while the unjacketed portion of the fiber was used only for sensing pressure/temperature induced strain. In case of N2 at 800 psig pressure, the observed microstrain was approximately 80, 65, 50 and 35 µε at 100, 75.0, 46.8, and 23.4 RH% respectively. Comparatively, a microstrain of approximately 95 µε was observed with 100% RH CH4 which demonstrates that SMF produces a measurable CH4 response alongside water. Similarly, the observed microstrain with CO2 was approximately 105, 90, 85, 80, and 70 µε at 100, 75.0, 46.8, 23.4, and 0 RH% respectively. Linear regression and principal component analysis of these dataset provided deconvolution of the impact of strain from H2O, CH4, and CO2 enabling good cross sensitivity. Additionally, modified OFS comprising of Fe coated fiber section was employed to monitor corrosion, using Fe as corrosion proxy, under harsh corrosive environment.

Mainali, Badri↗

Multi-Parameter Optical Fiber Sensing of Humidity, CH4, CO2, and Corrosion

In this work, the previously demonstrated capability of the optical fiber sensor (OFS) for successful monitoring of humidity has been extended to monitor the humidity, CH4, and CO2 with different gas composition based on the strain produced along the single mode fiber (SMF) sensor. This is enabled by absorption of H2O/gases on to the commercially available polyacrylate coated jacketed portion of the fiber resulting a change in strain. Under equilibrium, a differential microstrain was observed along the jacketed portion of the SMF with N2, CH4, and CO2 at different humidity conditions, while the unjacketed portion of the fiber was used only for sensing pressure/temperature induced strain. In case of N2 at 800 psig pressure, the observed microstrain was ~80, ~65, ~50 and ~35 µε at 100, 75.0, 46.8, and 23.4 RH% respectively. Comparatively, a microstrain of ~95 µε was observed with 100% RH CH4 which demonstrates that SMF produces a measurable CH4 response alongside water. Similarly, the observed microstrain with CO2 was ~105, ~90, ~85, ~ 80, and ~70 µε at 100, 75.0, 46.8, 23.4, and 0 RH% respectively. Linear regression and principal component analysis of these dataset provided deconvolution of the impact of strain from H2O, CH4, and CO2 enabling good cross sensitivity. Additionally, modified OFS comprising of Fe coated fiber section was employed to monitor corrosion based on the increase in backscattered intensity amplitude of the light being passed once corrosion occurs.

Mainali, Badri↗

Evaluating the Feasibility of Using Strain Measured During Sinusoidal Rate Pumping Tests to Characterize an Aquifer

Pumping tests with sinusoidal variation in pumping rate have been proposed as a method for improving aquifer characterization. These tests can interrogate a larger aquifer volume than slug tests and they can be more sensitive to small variations in drawdown. Current methods of using sinusoidal variations of rate are based on measuring pressure signals from the reservoir or aquifer, which requires access to monitoring wells. An alternative approach has been developed that measures the strain in the vadose zone instead of pressure in the reservoir. An instrument has been developed at Clemson University that can measure small strains using optical fiber sensors, and we propose that it can be used to measure strain during sinusoidal pumping tests. The objective of this project is to evaluate the feasibility of measuring and interpreting the vertical strain in the vadose zone generated during a sinusoidal rate pumping tests to estimate aquifer and/or overburden properties. Pumping tests were performed at a site with a water table at 9 m and saturated saprolite from 9 to 30m depth. Sinusoidal pumping tests in the saprolite used different pumping amplitudes and periods while pressure was measured at three piezometers and vertical strain was measured in the vadose zone from 1 to 7 m depth. The delay time of the pressure increased linearly with distance, and it increased with the square root of the period, while the amplitude of the pressure decreased with distance and increased with amplitude. Vertical strain in the vadose zone varied with the same period as the pumping rate and the delay times were similar to those for pressures measured at similar radial distances. Delay times for the strain increased with an increasing propagation of the strain field. The hydraulic diffusivity was estimated using delay times for pressure and strain, and the results were compared with the values estimated from a constant-rate pumping test. The hydraulic diffusivity from the constant rate test was 0.039 m2/sec, whereas it was 0.053 (±0.05) m2/sec and 0.035 (±0.03) m2/sec from the pressure data and 0.08 (±0.022) m2/sec and 0.035 (±0.001) m2/sec from the strain data from sinusoidal tests of various periods and amplitudes. There is no statistical difference among these values. This study indicates that strain measurements in the vadose zone can be used to estimate aquifer properties during sinusoidal pumping tests.

Blais, Riley↗

A High-Temperature Multipoint Hydrogen Sensor Using an Intrinsic Fabry–Perot Interferometer in Optical Fiber

This paper presents a multiplexable fiber optic chemical sensor with the capability of monitoring hydrogen gas concentration at high temperatures up to 750 °C. The Pd-nanoparticle infused TiO 2 films coated on intrinsic Fabry–Perot interferometer (IFPI) array were used as sensory films. Strains induced upon exposure to hydrogen with varied concentrations can be monitored by IFPI sensors. The fiber sensor shows a repetitive and reversible response when exposed to a low level (1–6%) of hydrogen gas. Uniform sensory behavior across all the sensing cavities is demonstrated and reported in this paper.

47 OTHER INSTRUMENTATION↗

Glass 3D Printing of Microfluidic Pressure Sensor Interrogated by Fiber-Optic Refractometry

This letter reports a novel fused silica microfluidic device with pressure sensing capability that is fabricated by integrated additive and subtractive manufacturing (IASM) method. The sensor consists of a capillary and a 3D printed glass reservoir, where the reservoir volume change under pressure manifests liquid level deviation inside the capillary, thus realizing the conversion between small pressure change into large liquid level variation. Thanks to the design flexibility of this unique IASM method, the proposed microfluidic device is fabricated with liquid-in-glass thermometer configuration, where the reservoir is sealed following a novel 3D printing assisted glass bonding process. And liquid level is interrogated by a fiber-optic sensor based on multimode interference (MMI) effect. This proposed microfluidic device is attractive for chemical and biomedical sensing because it is flexible in design, and maintains good chemical and mechanical stability, and adjustable sensitivity and range.

42 ENGINEERING↗

Demonstration of Embedded Sensors in Ceramic Structures

The Transformational Challenge Reactor (TCR) program seeks to demonstrate an advanced 3D printed nuclear reactor core. A binder jet additive manufacturing process is used to fabricate the complex SiC ceramic components of the TCR core. After printing, the components are densified via chemical vapor infiltration (CVI). This process allows complex cavities to be created in which sensors can be placed at strategic locations. Inserting the sensors during the CVI process allows the sensors to be embedded within the component as it is infiltrated. The primary challenge for embedding the sensors is identifying the sensors and sensor sheath materials that can survive the temperatures (>1,000°C) and chemical exposure to H 2 and HCl during CVI. The embedded sensors that are being investigated for use during TCR operation include thermocouples, self-powered neutron detectors, and spatially distributed fiber-optic temperature sensors. This report describes the CVI materials compatibility tests and initial trials for embedding functional sensors. Mo is identified as the most suitable sensor sheath material based on its availability in small diameter tubing, relatively low neutron absorption cross section, and compatibility with H 2 , HCl, and the surrounding SiC matrix at the process temperatures. Amorphous SiO2 fiber-optic samples with Au and Cu metal coatings were successfully embedded in SiC along with bare fibers, although the metal coatings showed some evidence of localized melting during CVI. Initial experiments attempting to embed functional sensors showed that the sensors can be embedded in 3D printed SiC parts, but there are still challenges that must be overcome to ensure that the sensors and sensor sheaths do not fail during CVI. In particular, Nb-sheathed Mo-Nb thermocouples failed at temperatures far lower than expected despite thermodynamic calculations and materials compatibility tests that show the Nb sheath to be compatible with the CVI environment. One potential explanation for the large expansion of the Nb sheath could be related to hydride formation in the lower temperature region of the sheath. Future work will focus on Mo-sheathed thermocouples instead of Nb. The fiberoptic sensors tested during the instrumented experiment broke due to the lack of mechanical protection after their polymer-based coatings were vaporized. Future instrumented experiments will use metal-coated optical fibers for strain sensing to provide additional mechanical protection. However, custom coatings with higher melting points than commercially available Au and Cu might be required. Regardless, fiber-optic sensors are still candidates for spatially distributed temperature measurements since they can be inserted into an embedded metal sheath after CVI.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Corrosion of Silica-Based Optical Fibers in Various Environments

This research article explores the potential of optical fibers as sensors, highlighting their ability to measure various parameters such as temperature, pressure, stress, and radiation dose. The study focuses on investigating the material compatibility of optical fibers in challenging sensing environments like Gen II/II+ and advance nuclear reactors, as well as concentrated solar power (CSP) plants. Material compatibility tests were conducted to determine the feasibility of using fluorine and germanium optical fiber sensors in these environments. The study found that raw fibers were corrosion-resistant to lead bismuth eutectic at 600 °C, regardless of the coating. In molten salt environments, raw fibers were incompatible with FLiNaK but showed corrosion resistance to MgCl₂-NaCl-KCl. However, the survivability of raw fiber optics improved with a gold coating in FLiNaK. Raw fiber optics were found to be incompatible in high-temperature steam at 1200 °C and in a pressurized water reactor (PWR) at 300 °C.

Leong, Amanda (ORCID:0000000307134493)↗

TRUST Sensors in Environments: Fiber Optic Displacement (SE-FOD)

The objective of the Delivery Environments (DE) Testbeds to Reduce Uncertainty in Simulations and Tests (TRUST) project is to quantify and help increase confidence in specific areas of computational and experimental capabilities that are applicable to the development, on-target assessment, and qualification of current and future delivery environments. More complete quantification of confidence in experimental and computational capabilities and the sufficient increase of confidence in those capabilities is critical to improving weapons engineering design, qualification, and assessment efforts that are critical to the current and future stockpile. Under the TRUST work package, engineers use and provide feedback on analysis tools and experimental results and create databases for efficient and responsive engineering which are currently under development.

42 ENGINEERING↗

Characterization and equalization of intensity-modulated voltage sensors

We test fiber-optic voltage sensors based on reflection from a piezoelectric transducer. Detailed characterization confirms a 60 dB dynamic range, and our equalization approach accurately recovers transient excitations, indicating the versatility of this sensor design in electric grid monitoring.

Lukens, Joseph↗