Closed-loop pulse shaping with <1ps resolution over >2ns records using STILETTO combined with Three Phase Spectral Interferometry (3PSI)
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
We conducted a series of plate impact experiments to examine the efficacy of < 111>-oriented gadolinium gallium garnet (GGG) single crystals as high-impedance optical window for Photonic Doppler velocimetry (PDV) under shock and double-shock loading. At ~ 123 GPa, shocked GGG remains fully transparent to 1550 nm light for at least 250 ns without any signal degradation. Above 135 GPa, PDV data measured through GGG exhibit a gradual loss of fringe contrast following shock entrance, which eventually leads to transparency loss. The duration for which shocked GGG remains transparent decreases with increasing pressure, and at ~ 148 GPa, it becomes opaque within ~ 20–30 ns. This limits the use of GGG as an interferometry window between ~ 110–140 GPa under single shock loading. Within this pressure range, the refractive index of GGG increases linearly with density: n = 1.552 + 0.054ρ. In contrast to single shock loading, where GGG becomes opaque rapidly above ~ 140 GPa, double-shocked GGG remains optically transparent for over 100 ns when it is first shocked to ~ 123 GPa and then reshocked to significantly higher pressures (215–233 GPa). Our findings raise the exciting possibility of GGG being used as a high-impedance optical window in multi-shock and shock-ramp loading experiments.
In order to efficiently image a non-absorbing sample (a phase object), dedicated phase contrast optics are required. Typically, these optics are designed with the assumption that the sample is weakly scattering, implying a linear relation between a sample’s phase and its transmission function. In the strongly scattering, nonlinear case, the standard optics are ineffective, and the transfer functions used to characterize them are uninformative. We use the Fisher information (FI) to assess the efficiency of various phase imaging schemes and to calculate an information transfer function (ITF). We show that a generalized version of Zernike phase contrast is efficient given sufficient prior knowledge of the sample. We show that with no prior knowledge, a random sensing measurement yields a significant fraction of the available information. Finally, we introduce a generalized approach to common path interferometry that can be optimized to prioritize sensitivity to particular sample features. Each of these measurements can be performed using Fourier lenses and phase masks.
Subpicosecond coincidence timing from nonlocal intensity interference of entangled photons allows quantum interferometry for plasmas. Using a warm plasma dispersion relation, we correlate phase measurement sensitivity with different plasma properties or physics mechanisms over six orders of magnitude. Due to Nα (α≤−1/2) scaling with the photon number N, quantum interferometry using entangled light can probe small signals in plasmas not previously accessible. As an example, it is predicted that plasmas will induce shifts to a Gaussian dip, a well-known quantum optics phenomenon that is yet to be demonstrated for plasmas.
Sub-picosecond coincidence timing from nonlocal intensity interference of entangled photons allows quantum interferometry for plasmas. Using a warm plasma dispersion relation, we correlate phase measurement sensitivity with different plasma properties or physics mechanisms over 6 orders of magnitude. Due to N α (α ≤ - 1/2) scaling with the photon number N, quantum interferometry using entangled light can probe small signals in plasmas not previously accessible. As an example, it is predicted that plasmas will induce shifts to a Gaussian dip, a well-known quantum optics phenomenon.
Dedicated spectrometers for terahertz radiation with [0.3, 30] THz frequencies using traditional optomechanical interferometry are substantially less common than their infrared and microwave counterparts. This paper presents the design and initial performance measurements of a tabletop Fourier transform spectrometer (FTS) for multi-terahertz radiation using infrared optics in a Michelson arrangement. This is coupled to a broadband pyroelectric photodetector designed for [0.1, 30] THz frequencies. We measure spectra of narrowband and broadband input radiation to characterize the performance of this instrument above 10 THz, where signal-to-noise is high. This paves the groundwork for planned upgrades to extend below 10 THz. We also briefly discuss potential astroparticle physics applications of such FTS instruments to broadband axion dark matter searches, whose signature comprises low-rate monochromatic photons with unknown frequency.
The carrier-envelope offset phase (CEP) of a few-cycle optical pulse is commonly used to control electron dynamics on the attosecond timescale, whereas lasing spectra from transitions between rotational states are generally emitted over much longer durations, typically nanoseconds. Here, we demonstrate CEP control of the rotational lasing spectra corresponding to the transition from B 2 Σ$^+_u$ to X 2 Σ$^+_g$ (1) in N$^+_2$ cations, transforming its lineshape from a symmetric Lorentzian profile to an asymmetric Fano type–and vice versa. This lineshape modulation arises from the interference between the B-X coherence initiated by the main pulse and the supercontinuum (self seed) by self-phase modulation, resembling an “f-to-3f" interferometry. Additionally, for lasing lines with lower rotational quantum numbers, we observe a stronger coupling between adjacent lasing peaks, which originates from the amplification of both even- and odd-order rotational coherent emission lines. Our study presents a general framework for controlling lasing lineshapes and provides new insights into sub-optical-cycle dynamics in air lasing.
Abstract The extreme miniaturization of a cold-atom interferometer accelerometer requires the development of novel technologies and architectures for the interferometer subsystems. Here, we describe several component technologies and a laser system architecture to enable a path to such miniaturization. We developed a custom, compact titanium vacuum package containing a microfabricated grating chip for a tetrahedral grating magneto-optical trap (GMOT) using a single cooling beam. In addition, we designed a multi-channel photonic-integrated-circuit-compatible laser system implemented with a single seed laser and single sideband modulators in a time-multiplexed manner, reducing the number of optical channels connected to the sensor head. In a compact sensor head containing the vacuum package, sub-Doppler cooling in the GMOT produces 15 μK temperatures, and the GMOT can operate at a 20 Hz data rate. We validated the atomic coherence with Ramsey interferometry using microwave spectroscopy, then demonstrated a light-pulse atom interferometer in a gravimeter configuration for a 10 Hz measurement data rate and T = 0–4.5 ms interrogation time, resulting in Δ g / g = 2.0 × 10 −6 . This work represents a significant step towards deployable cold-atom inertial sensors under large amplitude motional dynamics.
We propose a novel search technique for axions with a C P -violating monopole coupling g ˜ Q to bulk Standard Model charges Q ∈ { B , L , B − L } . Gradients in the static axion field configurations sourced by matter induce achromatic circular photon birefringence via the axion-photon coupling g ϕ γ . Circularly polarized light fed into an optical or (open) radio-frequency (RF) Fabry-Pérot (FP) cavity develops a phase shift that accumulates up to the cavity finesse: the fixed axion spatial gradient prevents a cancellation known to occur for an axion dark-matter search. The relative phase shift between two FP cavities fed with opposite circular polarizations can be detected interferometrically. This time-independent signal can be modulated up to nonzero frequency by altering the cavity orientations with respect to the field gradient. Multiwavelength co-metrology techniques can be used to address chromatic measurement systematics and noise sources. With Earth as the axion source, we project reach beyond current constraints on the product of couplings g ˜ Q g ϕ γ for axion masses m ϕ ≲ 10 − 5 eV . If shot-noise-limited sensitivity can be achieved, an experiment using high-finesse RF FP cavities could reach a factor of ∼ 10 5 into new parameter space for g ˜ Q g ϕ γ for masses m ϕ ≲ 4 × 10 − 11 eV . Published by the American Physical Society 2024
=A fast wave interferometer (FWI), which can measure ion mass density, has been developed on DIII-D for its use on future fusion reactors, as well as for the study of ion behavior in current plasma devices. The frequency of the fast waves used for the FWI is around 60 MHz, and require antennas and coaxial cables or waveguides, which, unlike traditional mirror-based optical interferometers, are less susceptible to neutron/gamma-ray radiation and are relatively immune to impurity deposition and erosion as well as alignment issues. The bulk ion density evaluated using FWI show good agreement with that derived from CO 2 interferometry within about 15%. When the ion mass density measurement by FWI is combined with an electron density measurement from CO 2 interferometry, Z eff measurements are also enabled and are in agreement with those from visible Bremsstrahlung measurements. Additionally, large-bandwidth FWI measurements clearly resolve 10–100 kHz coherent modes and demonstrate its potential as a core fluctuation diagnostic, sensitive to both magnetic and ion density perturbations.
A guided cold-atom inertial sensor system comprises an atom trap integrated platform, a laser system, a magnetic field system, a control system, and a computing system. The laser system and magnetic field system are adapted to form a magneto-optical trap (MOT) about a suspended waveguide of the atom trap integrated platform made of membrane integrated photonics. After loading cold atoms from a MOT, the photonic atom trap integrated platform generates one-dimensional guided atoms with an evanescent field optical dipole trap (EF-ODT) along the optical waveguide to create guided atomic accelerometers/gyroscopes. Motion of atomic wavepackets in a superposition state is created along the guided atom geometry by way of state-dependent momentum kicks. The light-pulse sequence of guided atom interferometry splits, redirects, and recombines atomic wavepackets, which allows measurement of atom interference fringes sensitive to inertial forces via a probe laser.
Conventional spectroscopy uses classical light to detect matter properties through the variation of its response with frequencies or time delays. Quantum light opens up new avenues for spectroscopy by utilizing parameters of the quantum state of light as novel control knobs and through the variation of photon statistics by coupling to matter. This Roadmap article focuses on using quantum light as a powerful sensing and spectroscopic tool to reveal novel information about complex molecules that is not accessible by classical light. It aims at bridging the quantum optics and spectroscopy communities which normally have opposite goals: manipulating complex light states with simple matter e.g. qubits versus studying complex molecules with simple classical light, respectively. Here, articles cover advances in the generation and manipulation of state-of-the-art quantum light sources along with applications to sensing, spectroscopy, imaging and interferometry.
The project aimed to drive strong-field excitation of bound electronic coherences in gas-phase atoms and molecules using a novel source of near-single-cycle optical field transients, based on industrial-grade Yb:solid-state laser technology. Key objectives included generating near-single cycle field transients and isolated attosecond pulses, reconstructing time-dependent wave packets in atoms and molecules, probing their decoherence using attosecond interferometry, and controlling the dynamic evolution of systems on attosecond to few-femtosecond timescales. A secondary goal of the project was to develop field-resolved measurement platforms as a novel approach for studying electron dynamics in atomic and molecular systems.
The shock wave response of [100] lithium fluoride (LiF) single crystals at high stresses is of long-standing interest due to their extensive use as optical windows in dynamic compression experiments. The report of melting in shock compressed LiF single crystals between 134 GPa and 152 GPa – based on a single sound speed datum [J. Appl. Phys. 117, 045901 (2015)] – was surprising because good optical transmission was previously demonstrated in LiF shock compressed to ~200 GPa [J. Appl. Phys. 116, 033515 (2014)]. To address these apparent differences, we report on plate impact experiments on [100] LiF single crystals shock compressed to 168 GPa. Wave profiles were measured using laser interferometry to determine Hugoniot states and longitudinal sound speeds in shock compressed LiF. The measured Hugoniot states are in good agreement with those measured in previous studies. However, the measured sound speeds presented here show no evidence of melting up to 168 GPa. In particular, the abrupt drop reported previously in sound speed at 152 GPa was not observed in the present work. Furthermore, our results establish a lower bound of 168 GPa for the onset of melting in shock compressed LiF single crystals.
X-ray lasers have evolved from a Star Wars missile defense system to a table-top research tool: (1) LLNL proposes X-ray laser schemes in the 1970’s, (2) First X-ray lasers demonstrated in early 1980’s were nuclear pumped, (3) Demonstrated the world’s shortest wavelength, highest energy laser, (4) First laboratory X-ray laser demonstrated on Novette in 1984, (5) A decade of progress using the Nova laser (5 kJ) from 1985 to 1996, (6) X-ray lasers produced at the COMET table-top facility (<10 J) since 1997, (7) X-ray lasers used for plasma interferometry and other applications, (8) 10 Hz X-ray laser at 18.9 nm demonstrated in 2004 using 0.15 J drive, (9) 100 Hz X-ray laser at 13.9 nm produces 1 µJ of saturated output using 0.9 J drive from diode-pumped optical laser in 2014.
The major accomplishments of my project were successfully developing and testing the laser interferometry diagnostic on the Plasma Liner Experiment (PLX) at Los Alamos National Laboratory (LANL). This diagnostic helped advance my research by providing a simpler way to obtain electron density measurements of magnetized plasmas compared to other electron density diagnostics such as triple Langmuir probes. The laser used was a 561 nm continuous wave (CW) diode-pumped solid state (DPSS) laser. The PLX laser interferometry diagnostic consists of two parts. These include the launching and receiving sides of the laser diagnostic. The launching side consists of the main laser beam from the DPSS laser being split into five chords(probe beams) and a reference beam which are then directed with fiber optic couplers into fiber optic cables which transmit the probe beamsto the PLX vacuum chamber. The probe beams then pass through the plasma in the chamber and into the receiving side optics where they are again directed through fiber optic cables to be combined with the reference beam. The combined beams are transmitted via multi-mode fiber optic cables to photodiodes to convert the light signals into electrical signals. Before the electrical signals get digitized, they pass through bandpass and low pass filters to eliminate electromagnetic noise and unwanted frequencies. The electrical signals are then processed by IQ demodulators to determine phase angle difference between the probe and reference beams for each chord in order to calculate line-integrated electron density.
The periodic longitudinal density modulation of relativistic electrons at the resonant wavelength (microbunching) is a fundamental aspect of free-electron lasers (FELs). In one case, microbunching fractions reached 20% at saturation of a self-amplified spontaneous emission (SASE) FEL resulting in gains of 1 million at 530 nm. In that experiment the $\textit{z}$-dependent gain of coherent optical transition radiation (COTR) was also measured. In laser-driven plasma accelerators (LPAs), microbunching at visible wavelengths has also been recently reported as evidenced by significant COTR enhancements measured in near-field and far-field images on a single shot for the first time. An analytical model for COTR interferometry (COTRI) addresses both cases. The broadband microbunching observed in the LPA case could act as a seed for a SASE FEL experiment with tunability in principle over the visible regime.
Talbot–Lau x-ray interferometry is a grating-based phase-contrast technique, which enables measurement of refractive index changes in matter with micrometric spatial resolution. The technique has been established using a variety of hard x-ray sources, including synchrotron, free-electron lasers, and x-ray tubes, and could be used in the optical range for low-density plasmas. The tremendous development of table-top high-power lasers makes the use of high-intensity, laser-driven K-alpha sources appealing for Talbot–Lau interferometer applications in both high-energy-density plasma experiments and biological imaging. To this end, we present the first, to the best of our knowledge, feasibility study of Talbot–Lau phase-contrast imaging using a high-repetition-rate laser of moderate energy (100 mJ at a repetition rate of 10 Hz) to irradiate a copper backlighter foil. The results from up to 900 laser pulses were integrated to form interferometric images. A constant fringe contrast of 20% is demonstrated over 100 accumulations, while the signal-to-noise ratio continued to increase with the number of shots. Phase retrieval is demonstrated without prior ex-situ phase stepping. Instead, correlation matrices are used to compensate for the displacement between reference acquisition and the probing of a PMMA target rod. The steps for improved measurements with more energetic laser systems are discussed. The final results are in good agreement with the theoretically predicted outcomes, demonstrating the applicability of this diagnostic to a range of laser facilities for use across several disciplines.