Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical transmission systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Reflection Effects in Multimode Fiber Systems Utilizing Laser Transmitters

A number of optical communication lines are now in use at NASA-Kennedy for the transmission of voice, computer data, and video signals. Now, all of these channels use a single carrier wavelength centered near 1300 or 1550 nm. Engineering tests in the past have given indications of the growth of systematic and random noise in the RF spectrum of a fiber network as the number of connector pairs is increased. This noise seems to occur when a laser transmitter is used instead of a LED. It has been suggested that the noise is caused by back reflections created at connector fiber interfaces. Experiments were performed to explore the effect of reflection on the transmitting laser under conditions of reflective feedback. This effort included computer integration of some of the instrumentation in the fiber optic lab using the Lab View software recently acquired by the lab group. The main goal was to interface the Anritsu Optical and RF spectrum analyzers to the MacIntosh II computer so that laser spectra and network RF spectra could be simultaneously and rapidly acquired in a form convenient for analysis. Both single and multimode fiber is installed at Kennedy. Since most are multimode, this effort concentrated on multimode systems.

Bates, Harry E.↗

Hyperspectral imaging of exciton confinement within a moiré unit cell with a subnanometer electron probe

Electronic and optical excitations in two-dimensional systems are distinctly sensitive to the presence of a moiré superlattice. Here we used cryogenic transmission electron microscopy and spectroscopy to simultaneously image the structural reconstruction and associated localization of the lowest-energy intralayer exciton in a rotationally aligned WS 2 -WSe 2 moiré superlattice. In conjunction with optical spectroscopy and ab initio calculations, we determined that the exciton center-of-mass wave function is confined to a radius of approximately 2 nanometers around the highest-energy stacking site in the moiré unit cell. Our results provide direct evidence that atomic reconstructions lead to the strongly confining moiré potentials and that engineering strain at the nanoscale will enable new types of excitonic lattices.

36 MATERIALS SCIENCE↗

Multimodal correlative study of Hall transport and magnetic phases in Fe/Gd multilayer systems

The Fe/Gd multilayer system hosts a number of magnetic phases, such as stripe, mixed stripe and skyrmion, skyrmion lattice, and isolated skyrmions for a wide range of temperature and magnetic field. We report different Hall transport signals in a Fe/Gd system through multimodal correlative resonant soft x-ray scattering (RSXS), Hall effect, magneto-optic Kerr effect, and transmission x-ray microscopy measurements. The simultaneous nature of the RSXS and Hall transport measurements allowed us to accurately connect various features in the transport data with the specific magnetic phases. We found that the topological Hall effect (THE) shows peaks with opposite signs, which we attribute to two different mechanisms. Our multimodal correlative study indicates that the sign reversal in THE occurs when the system transforms to and from a skyrmion lattice and low density isolated skyrmion phases. We propose that the skyrmion lattice contributes to the THE through a Berry phase induced emergent magnetic field mechanism in one case, and a skew scattering mechanism corresponding to the isolated low density skyrmion state.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Opportunistic Hybrid Communications Systems for Distributed PV Coordination

A full-scale, operational implementation of the opportunistic hybrid communications systems for distributed photovoltaic (PV) coordination was successfully developed, simulated, and validated in this 3-year project. The system is considered hybrid because it uses different communications pathways from the scale of residential PV inverters to a transmission network; primary technologies harnessed include Low-Power Wireless Personal Area Network (LoWPAN), Power Line Communication (PLC), WiFi mesh, Worldwide Interoperability for Microwave Access (WiMAX), Ethernet cable, and Optical Ethernet systems. It is opportunistic in that it chooses to route messages through each of these systems based on recent data about latency and availability to ensure reliable message passing.

14 SOLAR ENERGY↗

Development of an Attenuated Total Reflectance–Ultraviolet–Visible Probe for the Online Monitoring of Dark Solutions

Optical spectroscopy is a valuable tool for on-line monitoring of a variety of processes. Ultraviolet-visible (UV-vis) spectroscopy in particular, can monitor the concentration of analytes as well as identify speciation and oxidation state. However, it can be difficult to impossible to employ UV-vis based sensors on chemical systems that are very dark (i.e., high optical density) as exceedingly short pathlengths are required (for transmission approaches) or effective means of backscattering are needed (for reflectance approaches). Examples of processes that would benefit significantly from the use of optical sensors and encounter these challenges include used nuclear fuel recycling and molten salts with high concentrations of dissolved uranium. Utilizing an attenuated total reflectance (ATR) UV-vis approach can overcome these challenges and allow for the measurement of solutions orders of magnitude more concentrated than transmission UV-vis. However, determining ideal sensor specifications for varied processes can be time consuming and expensive. Here, in this study, we evaluate the ability for a novel ATR-UV-vis probe to measure very concentrated solutions of Co(II) and Ni(II) nitrate as well as organic dyes (methylene blue, acid red 1, and crystal violet). This sensor design provides a modular method for exploring possible “pathlengths” by altering the exposed ATR fiber length. Also studied were approaches to loading and measuring the sensor cell. These results are compared to a traditional 1 cm cuvette measured by transmission UV-vis. It was found that the ATR-UV-vis probe was capable of measuring solutions 600 times more concentrated than the 1 cm cuvette. Advanced data analysis in the form of multivariate curve resolution (MCR) was used to analyze the speciation of methylene blue over a large concentration range. The application of this novel ATR-UV-vis probe to the interrogation of dark solutions is a promising avenue for use in on-line monitoring of nuclear processes.

47 OTHER INSTRUMENTATION↗

Acquisition and description of Mariner 10 television science data at Mercury

The Mariner 10 television science subsystem was an improved version of the Mariner 9 system, using 1500-mm-focal-length optics. An elaborate picture-taking sequence resulted in transmission of over 4000 frames back to earth during two flyby encounters with Mercury. These sequences utilized a real-time data rate of 117.6 kbit/s, resulting in coverage of about 75% of the lighted portion of Mercury's surface at a resolution of better than 2 km. The complete set of useful images, which amounted to about 3000 frames, was processed with three different types of digital image-processing enhancements.

Danielson, G. E., Jr.↗

NASA/USRA advanced space design program: The laser powered interorbital vehicle

A preliminary design is presented for a low-thrust Laser Powered Interorbital Vehicle (LPIV) intended for cargo transportation between an earth space station and a lunar base. The LPIV receives its power from two iodide laser stations, one orbiting the earth and the other located on the surface of the moon. The selected mission utilizes a spiral trajectory, characteristic of a low-thrust spacecraft, requiring 8 days for a lunar rendezvous and an additional 9 days for return. The ship's configuration consists primarily of an optical train, two hydrogen plasma engines, a 37.1 m box beam truss, a payload module, and fuel tanks. The total mass of the vehicle fully loaded is 63300 kg. A single plasma, regeneratively cooled engine design is incorporated into the two 500 N engines. These are connected to the spacecraft by turntables which allow the vehicle to thrust tangentially to the flight path. Proper collection and transmission of the laser beam to the thrust chambers is provided through the optical train. This system consists of the 23 m diameter primary mirror, a convex parabolic secondary mirror, a beam splitter and two concave parabolic tertiary mirrors. The payload bay is capable of carrying 18000 kg of cargo. The module is located opposite the primary mirror on the main truss. Fuel tanks carrying a maximum of 35000 kg of liquid hydrogen are fastened to tracks which allow the tanks to be moved perpendicular to the main truss. This capability is required to prevent the center of mass from moving out of the thrust vector line. The laser beam is located and tracked by means of an acquisition, pointing and tracking system which can be locked onto the space-based laser station. Correct orientation of the spacecraft with the laser beam is maintained by control moment gyros and reaction control rockets. Additionally an aerobrake configuration was designed to provide the option of using the atmospheric drag in place of propulsion for a return trajectory.

Source record↗

Laser powered interorbital vehicle

A preliminary design of a low-thrust Laser Powered Interorbital Vehicle (LPIV) intended for cargo transportation between an Earth space station and a lunar base is presented. The selected mission utilizes a spiral trajectory, characteristic of a low-thrust spacecraft, requiring eight days for a lunar rendezvous and an additional nine days for return. The ship's configuration consists primarily of an optical train, two hydrogen plasma engines, a 37.1 m box-beam truss, a payload module, and propellant tanks. The total mass of the vehicle, fully loaded, is 63,300 kg. A single plasma, regeneratively cooled engine design is incorporated into the two 500 N engines. These are connected to the spacecraft by turntables that allow the vehicle to thrust tangential to the flight path. Proper collection and transmission of the laser beam to the thrust chambers is provided through the optical train. This system consists of a 23-m-diameter primary mirror, a convex parabolic secondary mirror, a beam splitter, and two concave parabolic tertiary mirrors. The payload bay is capable of carrying 18,000 kg of cargo and is located opposite the primary mirror on the main truss. Fuel tanks carrying a maximum of 35,000 kg of liquid hydrogen are fastened to tracks that allow the tanks to be moved perpendicular to the main truss. This capability is required to prevent the center of mass from moving out of the thrust vector line. The laser beam is located and tracked by means of an acquisition, pointing, and tracking system that can be locked onto the space-based laser station. Correct orientation of the spacecraft with the laser beam is maintained by control moment gyros and reaction control rockets. In addition, an aerobrake configuration was designed to provide the option of using the atmospheric drag in place of propulsion for a return trajectory.

Clarke, M. T.↗

Real-Time X-Ray Transmission Microscopy for Fundamental Studies Solidification

High resolution real-time X-ray Transmission Microscopy, XTM, has been applied to obtain information fundamental to solidification of optically opaque metallic systems. We have previously reported the measurement of solute profile in the liquid, phase growth, and detailed solid-liquid interfacial morphology of aluminum based alloys with exposure times less than 2 seconds. Recent advances in XTM furnace design have provided an increase in real-time magnification (during solidification) for the XTM from 4OX to 16OX. The increased magnification has enabled for the first time the XTM imaging of real-time growth of fibers and particles with diameters of 5 micrometers. We have applied this system to study of the kinetics of formation and morphological evolution of secondary fibers and particles in Al-Bi monotectic alloys to observe a previously unreported velocity dependent thermo-capillary depletion mechanism for Bi rich liquid which can penetrate many fiber diameters into the solid-liquid interface. In this talk we will discuss application of the XTM to the study the fundamentals of monotectic and eutectic solidification, the enhancement of XTM data with precise solid liquid interfacial temperature and thermal gradient measurement techniques, and the application of this technology to the study of the fundamentals of solidification in microgravity,

Curreri, Peter A.↗

Characterization of Measurement Error Sources in Doppler Global Velocimetry

Doppler global velocimetry uses the absorption characteristics of iodine vapor to provide instantaneous three-component measurements of flow velocity within a plane defined by a laser light sheet. Although the technology is straightforward, its utilization as a flow diagnostics tool requires hardening of the optical system and careful attention to detail during data acquisition and processing if routine use in wind tunnel applications is to be achieved. A development program that reaches these goals is presented. Theoretical and experimental investigations were conducted on each technology element to determine methods that increase measurement accuracy and repeatability. Enhancements resulting from these investigations included methods to ensure iodine vapor calibration stability, single frequency operation of the laser and image alignment to sub-pixel accuracies. Methods were also developed to improve system calibration, and eliminate spatial variations of optical frequency in the laser output, spatial variations in optical transmissivity and perspective and optical distortions in the data images. Each of these enhancements is described and experimental examples given to illustrate the improved measurement performance obtained by the enhancement. The culmination of this investigation was the measured velocity profile of a rotating wheel resulting in a 1.75% error in the mean with a standard deviation of 0.5 m/s. Comparing measurements of a jet flow with corresponding Pitot measurements validated the use of these methods for flow field applications.

Meyers, James F.↗

Satellite Hyperspectral Imaging Simulation

Simulation of generic pushbroom satellite hyperspectral sensors have been performed to evaluate the potential performance and validation techniques for satellite systems such as COIS(NEMO), Warfighter-1(OrbView-4) and Hyperion(EO-1). The simulations start with a generation of synthetic scenes from material maps of studied terrain. Scene-reflected radiance is corrected for atmospheric effects and convolved with sensor spectral response using MODTRAN 4 radiance and transmissions calculations. Scene images are further convolved with point spread functions derived from Optical Transfer Functions (OTF's) of the sensor system. Photon noise and etectorr/electronics noise are added to the simulated images, which are also finally quantized to the sensor bit resolution. Studied scenes include bridges and straight roads used for evaluation of sensor spatial resolution, as well as fields of minerals, vegetation and manmade materials used for evaluation of sensor radiometric response and sensitivity. The scenes are simulated with various seasons and weather conditions. Signal-to-noise ratios and expected performance are estimated for typical satellite system specifications and are discussed for all the scenes.

Zanoni, Vicki↗

Satellite Hyperspectral Imaging Simulation

Simulations of generic pushbroom satellite hyperspetral sensors have been performed to evaluate the potential performance and validation techniques for satellite systems such as COIS (NEMO), Warfighter-1 (OrbView-4), and Hyperion (EO-1). The simulaitons start with a generation of synthetic scenes form material maps of studied terrain. Scene-reflected radiance is corrected for atmospheric effects and convolved with sensor spectral response uwing MODTRAN 4 radiance and transmission calculations. Scene images are further convolved with point spread functions derived from Optical Transfer Functions (OTF's) of the sensor system. Photon noise and detector/electronics noise are added to the simulated images, which are also finally quantized to the sensor bit resolution. Studied scenes include bridges and straight roads used for evaluation of sensor spatial resolution, as well as fields of minerals, vegetation, and manmade materials used for evaluation of sensor radiometric response and sensitivity. The scenes are simulated with various seasons and weather conditions. Signal-to-noise ratos and expected performance are estimated for typica satellite system specifications and are discussed for all the scenes.

Zanoni, Vicki↗

InGaAsP Avalanche Photodetectors for Non-Gated 1.06 micrometer Photon-Counting Receivers

The efficient detection of single photons at 1.06 micron is of considerable interest for lidar/ladar systems designed for remote sensing an d ranging as well as for free-space optical transmission in photon-st arved applications. However, silicon-based single photon avalanche diodes (SPADs) used at shorter wavelengths have very low single photon d etection efficiency (approximately 1 - 2%) at 1.06 micron, and InP/In GaAs SPADs designed for telecommunications wavelengths near 1.5 micro n exhibit high dark count rates that generally inhibit non-gated (free-running) operation. To bridge this "single photon detection gap" for wavelengths just beyond 1 micron, we have developed high performance , large area (80 - 200 micron diameter) InP-based InGaAsP quaternary absorber SPADs optimized for operation at 1.06 micron and based on a highly reliable planar geometry avalanche photodiode structure. We wil l show that dark count rates are sufficiently low to allow for non-ga ted operation while achieving detection efficiencies far surpassing t hose found for Si SPADs. At a detection efficiency of 10%, 80 micron diameter devices exhibit dark count rates below 1000 Hz and count rate s of at least 3 MHz when operated at -40 C. Significantly higher dete ction efficiencies (30 - 50%) are achievable with acceptable tradeoff s in dark count rate. In this paper, we will also discuss performance modeling for these devices and compare their behavior with longer wav elength InP-based InGaAs ternary absorber SPADs fabricated on a relat ed device design platform.

Itzler, Mark A.↗

Near field excited state imaging via stimulated electron energy gain spectroscopy of localized surface plasmon resonances in plasmonic nanorod antennas

Continuous wave (cw) photon stimulated electron energy loss and gain spectroscopy (sEELS and sEEGS) is used to image the near field of optically stimulated localized surface plasmon resonance (LSPR) modes in nanorod antennas. An optical delivery system equipped with a nanomanipulator and a fiber-coupled laser diode is used to simultaneously irradiate plasmonic nanostructures in a (scanning) transmission electron microscope. The nanorod length is varied such that the m = 1, 2, and 3 LSPR modes are resonant with the laser energy and the optically stimulated near field spectra and images of these modes are measured. Various nanorod orientations are also investigated to explore retardation effects. Optical and electron beam simulations are used to rationalize the observed patterns. As expected, the odd modes are optically bright and result in observed sEEG responses. The m = 2 dark mode does not produce a sEEG response, however, when tilted such that retardation effects are operative, the sEEG signal emerges. Thus, we demonstrate that cw sEEGS is an effective tool in imaging the near field of the full set of nanorod plasmon modes of either parity.

36 MATERIALS SCIENCE↗

Tissue-mimicking phantoms for performance evaluation of photoacoustic microscopy systems

Phantom-based performance test methods are critically needed to support development and clinical translation of emerging photoacoustic microscopy (PAM) devices. While phantoms have been recently developed for macroscopic photoacoustic imaging systems, there is an unmet need for well-characterized tissue-mimicking materials (TMMs) and phantoms suitable for evaluating PAM systems. Our objective was to develop and characterize a suitable dermis-mimicking TMM based on polyacrylamide hydrogels and demonstrate its utility for constructing image quality phantoms. TMM formulations were optically characterized over 400–1100 nm using integrating sphere spectrophotometry and acoustically characterized using a pulse through-transmission method over 8–24 MHz with highly confident extrapolation throughout the usable band of the PAM system. This TMM was used to construct a spatial resolution phantom containing gold nanoparticle point targets and a penetration depth phantom containing slanted tungsten filaments and blood-filled tubes. These phantoms were used to characterize performance of a custom-built PAM system. The TMM was found to be broadly tunable and specific formulations were identified to mimic human dermis at an optical wavelength of 570 nm and acoustic frequencies of 10–50 MHz. Imaging results showed that tungsten filaments yielded 1.1–4.2 times greater apparent maximum imaging depth than blood-filled tubes, which may overestimate real-world performance for vascular imaging applications. Nanoparticles were detectable only to depths of 120–200 µm, which may be due to the relatively weaker absorption of single nanoparticles vs. larger targets containing high concentration of hemoglobin. The developed TMMs and phantoms are useful tools to support PAM device characterization and optimization, streamline regulatory decision-making, and accelerate clinical translation.

Hsu, Hsun-Chia↗

Designing ITER motional Stark effect line shift (MSE-LS) spectrometers

As a part of ITER beam aided diagnostics, the design of Motional Stark Effect (MSE) diagnostic observing the emission from the Balmer-α line is underway. The physics of Stark splitting shows that the Stark manifold is polarization dependent, and the energy splitting results in a line shift proportional to the electric field. Due to the challenges of maintaining the calibration of the plasma facing mirrors in ITER, the conventional MSE polarimetry measurement technique is replaced with a spectral approach that is deemed more favorable in the ITER environment. The MSE line shift (LS) diagnostic is designed to quantify the Lorentz electric field magnitude by measuring the Stark manifold using visible spectroscopy. In the presence of large magnetic fields and high energy heating beams of 1 MeV, the expected Stark splitting is much larger than in typical devices. The MSE-LS design has unique challenges requiring careful consideration and modeling of its viewing geometry and photon budget. The MSE-LS approach on ITER is promising but has stringent demands on the allowable errors for the statistical and systematic fitting uncertainties. In this study, a full system model and numerical simulations of data for each sightline are completed. For a range of optical transmission fractions, photon noise analysis is conducted to determine the statistical uncertainties. This provides guidance on the spectrometer throughput, dispersion at the detector, optics, and other design choices. A conceptual design of a high throughput spectrometer with a volume phase transmission grating is presented.

Instruments & Instrumentation↗

Photon Detection System Calibration for DUNE

Photon Detection System Calibration for DUNE Not scheduled 20m Conference Center (University of California, Irvine) Poster New Technologies for Neutrino Physics Poster session Speaker Denis Torres (South Dakota School of Mines and Technology) Description The Deep Underground Neutrino Experiment (DUNE) is a long baseline neutrino oscillation experiment that relies on a precise Photon Detection System (PDS) to provide accurate timing information, enhance sensitivity to low-energy and non-beam events, and support detector performance studies in liquid argon time projection chambers. Achieving these goals requires a well-understood and stable optical calibration strategy that operates reliably under cryogenic conditions. In this poster, I will present PDS calibration studies performed in ProtoDUNE, focusing on the characterization of the ultraviolet (UV) light calibration system and key optical components in the light-delivery chain. I will discuss measurements of optical fiber transmission, SMA-to-SMA connector and feedthrough interface losses, and diffuser assemblies, emphasizing wavelength dependence, attenuation, and performance under cryogenic thermal cycling and stability tests. These studies provide quantitative inputs for understanding light transport, uniformity, and long-term reliability of the PDS in large-scale liquid argon detectors, and they directly inform calibration strategies for the DUNE Far Detector.

Torres Muñoz, Denis [South Dakota Sch. Mines Tech.↗