Search NASA⌕ Search

SEARCH · Search NASA

Results for “oscillations control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Beam Shaping and Oscillation for Metals Additive Manufacturing

Additive Manufacturing (AM) is pivotal for next-generation industrial manufacturing but is hampered by process control challenges leading to unwanted defects and sub-optimal material properties. Our research builds on prior work that utilized beam oscillation techniques to mitigate these issues (Wu et al., 2023). We focus on investigating the influence of beam oscillation frequency on melt pool dynamics, utilizing in-situ synchrotron material characterization from the ESRF (Chen et al., 2026). Preliminary findings indicated that beam oscillation results in unique fluid flow patterns and enhanced melting stability. These findings suggested the possibility of optimized AM process control, including minimized defects and tailored thermal histories. We proposed further research to explore the effects of beam oscillation frequencies comprehensively, using the in-situ characterization capabilities at the ESRF. The goal was to quantify this relationship, offering a pathway to more precise AM process control and optimization. Our research is expected to offer new scientific insights into the fluid mechanics and thermal behaviour in AM, contributing to its broader applicability and commercial viability.

36 MATERIALS SCIENCE↗

Operation and Control of Electric Vehicle Charger with Enhanced Dynamic Performance Under Non-Ideal Grid Voltage Condition

This paper presents a three-phase electric vehicle charger connected to the grid, featuring multiple boost converters on the DC side, specifically designed to ensure smooth, oscillation-free power transfer during unsymmetrical voltage sags. Precise control mechanisms are implemented on the boost converter side to regulate both voltage and current on the electric vehicle side, thereby maintaining optimal charging conditions. The control architecture for both the grid-connected and boost converter components is based on the Lyapunov energy function, which is employed to achieve superior dynamic performance and stability. The system's robustness and reliability are demonstrated through its ability to maintain stable operation and efficient power transfer despite fluctuations in grid conditions. Furthermore, the implementation of Lyapunov-based control ensures rapid response and minimal energy loss, enhancing the overall efficiency of the system. To validate the effectiveness of this approach, a comprehensive model of the system was developed and tested using MATLAB/Simulink, with detailed computer simulations conducted across various significant case studies.

DC-DC boost converter↗

Improving the nonlinear control performance of the supply fan at air handling units using a gain scheduling control strategy

Due to its nonlinear nature, the supply fan at air handling units with the controller tuned at the design condition tends to be aggressive and oscillate under partial load conditions. Here, the objective of this paper is to develop and validate a gain scheduling control strategy to improve its nonlinear control performance. First, a control-oriented model, which does not require numerous physical parameters and extensive test data, is developed to study the nonlinearity of the fan system. Based on the theoretical model and experimental verifications, the issue of an aggressive response with a conventional fixed-gain controller is caused by the fact that the system gain is proportional to the ratio of the duct static pressure to the fan speed. To address the issue, a scheduling function of the measurable duct static pressure and fan speed is proposed to be included in the conventional fixed-gain controller to compensate for the fan system gain variation. The gain scheduling control strategy is found to approximately maintain the identical control performance under all operation conditions. Most importantly, the gain scheduling control strategy can be readily implemented without intensive computation and additional measurements, showing a promising potential in industrial applications.

42 ENGINEERING↗

Adapting Optimal Velocity Tracking Control to Account for WEC Constraints and Power-Take-Off Efficiencies: Preprint

Wave energy converters (WECs) come in many different forms, from point absorbers, oscillating water columns, to bulge wave devices. This paper focuses on the control of point absorber WECs, which typically have a narrow-banded frequency response and, therefore, control is well placed to improve the energy capture of such WECs. The acausal nature of the control problem means that theoretically optimal control is almost impossible to achieve inpractice; however optimal velocity tracking (OVT) offers a simple and robust approximation to optimal control that can achieve better power capture than passive linear damping methods, albeit with necessarily higher force demands. OVT is a form of impedance matching and the magnitude of the power-take off (PTO) force demand is often not linearly proportional to the WEC velocity, which can lead to PTO force and speed combinations far from the optimalPTO efficiency. The highly non-linear PTO force and speed to efficiency mapping can, without remedial measures, severely diminish the effectiveness of OVT techniques. In this paper, limits to the movement and force of the PTO are demonstrated, allowing OVT to be more easily applied in practice. The effect of PTO efficiency is explored, and a potential solution to the problem of adapting control to account for efficiency is presented. Both aspects of the work presented highlight the requirement for co-design of the WEC, PTO, and controller.

conversion efficiency↗

Parameter-Varying Hydrodynamic Model of a Single Vane in a Variable-Geometry Oscillating Surge Wave Energy Converter: Preprint

This paper presents a study on the time-varying hydrodynamic modeling of an individual flap of a variable geometry oscillating surge wave energy converter (VGOSWEC). The WEC design incorporates controlled surfaces that can modify their orientation relative to the wave motion, reducing hydrodynamic pressure and related loads. This research focuses on characterizing the behavior of the oscillating WEC using a simplified model and three methods for achieving a continuous time-variant model: discrete hydrodynamic parameters, interpolation of hydrodynamic parameters, and a fitting function. The results of this study contribute to the understanding of time-varying hydrodynamic effects in variable geometry oscillating WECs. The findings provide insights into the potential for reducing structural loads and improving the overall performance of such devices. Further research and development in this area could lead to advancements in WEC technologies, enabling their integration into the competitive energy market.

HYDRO ENERGY,TIDAL AND WAVE POWER↗

Inter-Area Oscillation Damping with Type-5 Wind Power Plant

This paper investigates the potential of using brushless excitation (BLE) for not only riding through the fault but also to damp inter-area power oscillation with the help of a synchronous generator (SG) used in Type 5 Wind Power Plant (WPP). In BLE, an auxiliary synchronous generator (ASG) behaving like an exciter is coupled and driven by the rotor of the main SG. The BLE's field current's ASG is fed by two separate loops of the automatic voltage regulator (AVR) and power system stabilizer (PSS). The AVR system implements a control loop to regulate the generator terminal voltage, VT. For the PSS, the kinetic energy of the wind turbine is utilized according to the estimated rotational speed of the synchronous generator shaft of the SG. It may mitigate the necessity of any curtailment of active power for damping. The effectiveness of the proposed control scheme is verified with a three-phase short circuit fault in a two-area power system.

brushless↗

Inter-Area Oscillation Damping with Type-5 Wind Power Plant: Preprint

This paper investigates the potential of using brushless excitation (BLE) for not only riding through the fault but also to damp inter-area power oscillation with the help of a synchronous generator (SG) used in Type 5 Wind Power Plant (WPP). In BLE, an auxiliary synchronous generator (ASG) behaving like an exciter is coupled and driven by the rotor of the main SG. The BLE's field current's ASG is fed by two separate loops of the automatic voltage regulator (AVR) and Power System Stabilizer (PSS). The AVR system implements a control loop to regulate the generator terminal voltage, VT. For the PSS, the kinetic energy of the wind turbine is utilized according to the estimated rotational speed of the synchronous generator shaft of the SG. It mitigates the necessity of any curtailment of active power for damping. The effectiveness of the proposed control scheme is verified with a three-phase short circuit fault in a two-area power system.

brushless↗

Parameter-Varying Hydrodynamic Model of a Single Vane in a Variable-Geometry Oscillating Surge Wave Energy Converter

This paper presents a preliminary study on the parameter-varying hydrodynamic modeling of an individual vane of a variable-geometry oscillating surge wave energy converter (VGOSWEC). The WEC design incorporates controlled surfaces that can modify their orientation relative to the wave motion, reducing hydrodynamic pressure and related loads. This research focuses on characterizing the behavior of the oscillating WEC using a simplified model and three methods for achieving a continuous parameter-varying model: coarse hydrodynamic parameters, interpolation of hydrodynamic parameters, and a fitting function. The results of this study contribute to the understanding of parameter-varying hydrodynamic effects in variable geometry oscillating WECs. The findings provide insights into the potential for reducing structural loads and improving the overall performance of such devices. Further research and development in this area could lead to advancements in WEC technologies, enabling their integration into the competitive energy market.

analytical models↗

Sensor enabled data-driven predictive analytics for modeling and control with high penetration of DERs in distribution systems

The electric power grid is undergoing a tremendous transformation due to the increasing penetration of renewable energy resources beginning with wind and more recently with the distributed energy resources (DERs) such as solar and battery storage. DERs have dramatically changed the role of the distribution systems in the overall power grid, and they are expected to contribute a significant portion of power generation in the future. If current trends for DERs continue, system operation and control will need to change dramatically for improved grid reliability and resiliency. As renewable resources increase in penetration, new and challenging operational, planning, and design problems are expected to emerge. Some of the key challenges that arise in the planning and operation of the future grid are: 1) Quantifying the impact of high DER penetration in distribution systems on bulk grid behavior over multiple time scales. 2) Identifying whether a particular DER configuration/settings have a large impact on the overall grid behavior. These challenges can be addressed in an offline manner using detailed T&D grid models and they can also be addressed in an online manner using sensor measurements. In particular, the advancement and planned growth in sensor technology in power grid over various voltage levels provide us with a unique opportunity to tackle these challenges from a data analytic perspective without needing detailed T&D grid models. A few questions that naturally arise when addressing the challenges from DERs using sensor data are: 1) How can we use limited sensor measurements to monitor & control voltage stability and small signal stability of the bulk system? 2) How can we ensure that the developed data analytic methods are robust to data availability and quality issues? 3) How can we compute the developed analytics in a scalable manner using streaming measurements? In this project, we addressed the aforementioned challenges arising from DERs and answered the questions raised above on how to effectively use the sensor measurements to enhance the reliability and performance of the electric grid. Thus, the overarching goal of this project is to develop effective reduced/representative system models from data that make the computational complexity sufficiently manageable so as to be useful to simulate, analyze, and even control complex non-linear power systems dynamics with large penetrations of DERs. In order to achieve the objective, the project team established a four-fold technical approach 1) Formulated a combined transmission-distribution co-simulation framework for data generation and validation, 2) Derived reduced/representative models of power systems based on data-driven methods for efficient computation and appropriate representation of system behavior, 3) Developed data driven characterization of power system behavior based on transfer operator theory, machine learning and optimization for model estimation, 4) Incorporated a scalable data management and processing architecture using distributed Kafka streaming applications that coordinate input data streams to the developed data analytics. The key accomplishments of the project are: 1) Development of a scalable multi-timescale T&D co-simulation framework (both for steady state and for dynamic co-simulation) using commercial solvers (PSSE and GridLAB-D). The steady-state T&D co-simulation interface is shared with our industry partner (PJM). 2) A structured reduced order dynamic model of distribution systems that can represent partial motor stalling along with a systematic procedure to derive the model parameters. 3) A PMU based online method to monitor, localize and mitigate fault-induced delayed voltage recovery using DER reactive support and load control in distribution systems. 4) Development of linear operator based robust methodologies for dynamic state estimation, uncertainty quantification, system identification and trajectory prediction for power system dynamics. 5) An adaptive damping control for utilizing wind energy resources to provide oscillation damping and system stability. 6) Implementation of Kafka-based framework for efficient processing of streaming data using Linux-based local virtual environment.

DER integration↗

Stability-preserving Lossy Compression for Large-scale Partial Differential Equations

Checkpoint/Restart (C/R) strategies are vital for fault tolerance in PDE-based scientific simulations, yet traditional checkpointing incurs significant I/O overhead. Lossy compression offers a scalable solution by reducing checkpoint data size, but conventional methods often lack control over physical invariants (e.g., energy), leading to instability such as oscillations or divergence in Partial Differential Equations (PDE) systems. This paper introduces a stability-preserving compression approach tailored for PDE simulations by explicitly controlling kinetic and potential energy perturbations to ensure stable restarts. Extensive experiments conducted across diverse PDE configurations demonstrate that our method maintains numerical stability with minimal error magnification—even across multiple checkpoint-restart cycles—outperforming state-of-the-art lossy compressors. Parallel evaluations on the Frontier supercomputer show up to 8.4× improvement in checkpoint write performance and 6.3× in read performance, while maintaining relative L2 errors ∼ 2e-6 throughout continued simulation. These results provide practical guidance for balancing compression accuracy, stability, and computational efficiency in large-scale PDE applications.

Gong, Qian [ORNL] (ORCID:0000000235704142)↗

A comprehensive review of nonlinear oscillators in hydrokinetic energy harnessing using flow-induced vibrations

A comprehensive review of hydrokinetic energy converters based on alternating lift technology (ALT) is provided. Emphasis is on nonlinear oscillators based on Flow Induced Vibration (FIV) or Oscillation (FIO). Due to strong coupling in Fluid-Structure Interaction (FSI), and in order to maximize the hydrokinetic harnessed energy, design of nonlinear oscillators and analysis by model tests or computational fluid dynamics dominates this area. Research confirmed that the nonlinear oscillator can harvest energy from a stochastic excitation modeled by a generic wide spectrum, and overcome the most severe oscillator limitations: specifically, the need for continuous frequency tuning due to the narrow bandwidth response, and low efficiency outside the narrow bandwidth oscillator response. This review covers the following aspects of nonlinear oscillators in ALT converters: (1) Geometric changes in oscillator cross-section; e.g., circular, square, rectangular, or trilateral shapes. (2) Passive turbulence control of FIV/FIO. (3) Position based nonlinear stiffness. (4) Multi-cylinder synergistic FIV/FIO. (5) Mechanically linked oscillators. (6) Velocity-based, nonlinear, adaptive harnessing damping.

42 ENGINEERING↗

Electrical Control of the Nuclear Spin States of Rare-Earth Adatoms

Rare-earth adatoms on surfaces have been studied for potential atomic-scale magnetic storage, quantum sensing, and quantum computing applications. Despite accumulating experimental efforts, a comprehensive description of the electronic configurations of the adatoms remains elusive. Here, we investigate two charge states and several electronic configurations, including 5d and 6s valence shells, for a Sm adatom on a MgO substrate using multiconfigurational ab initio methods, for the possibility of using the Sm nuclear spin levels as qubits. For the configurations in a neutral charge state, we find that the electronic ground state is a singlet, and thus the hyperfine interaction associated with the 147 Sm nucleus is absent, which may greatly enhance nuclear spin coherence time. The degeneracy of the nuclear levels is lifted by the nuclear quadrupole interaction. We show that the splitting of the nuclear levels can be controlled by a static electric field, and that Rabi oscillations between the nuclear levels can be induced by a time-dependent electric field. For the configurations in a singly charged state, electronic Kramers doublets are formed. The electronic configurations including an unpaired 6s orbital exhibit a strong hyperfine Stark effect due to a large Fermi contact contribution to the hyperfine interaction. In these configurations, electric-field-induced Rabi oscillations between the electronic-nuclear levels can occur at frequencies up to 3 orders of magnitude higher than those for the neutral charge state. The proposed system may be experimentally observed within scanning tunneling microscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lyapunov stability of smart inverters using linearized distflow approximation

Fast-acting smart inverters that utilize preset operating conditions to determine real and reactive power injection/consumption can create voltage instabilities (over-voltage, voltage oscillations and more) in an electrical distribution network if set-points are not properly configured. In this work, linear distribution power flow equations and droop-based Volt–Var and Volt–Watt control curves are used to analytically derive a stability criterion using Lyapunov analysis that includes the network operating condition. The methodology is generally applicable for control curves that can be represented as Lipschitz functions. The derived Lipschitz constants account for smart inverter hardware limitations for reactive power generation. A local policy is derived from the stability criterion that allows inverters to adapt their control curves by monitoring only local voltage, thus avoiding centralized control or information sharing with other inverters. The criterion is independent of the internal time-delays of smart inverters. Simulation results for inverters with and without the proposed stabilization technique demonstrate how smart inverters can mitigate voltage oscillations locally and mitigate real and reactive power flow disturbances at the substation under multiple scenarios. The study concludes with illustrations of how the control policy can dampen oscillations caused by solar intermittency and cyberattacks.

42 ENGINEERING↗

A Strategy for Forced Oscillation Suppression

Wide-area time-synchronized measurements have recently revealed troublesome forced oscillations (FOs) within modern synchronized power grids. In some cases, these FOs represent a dangerous hazard to the system. Recent research has focused on locating the source of FOs to provide operators with knowledge for mitigating their impact locally. This paper presents a complementary mitigation strategy, which is to purposely induce a second oscillation into the grid which cancels the impact of the FO. Such a strategy is complementary in that it may provide valuable time to operators attempting to locate the FOs source and to determine how to rectify it. This paper presents a suppression control strategy which modulates controllable devices to automatically cancel the impact of the FO without the need for locating the source of the original FO. The strategy is based upon tuned feedback control. In this study, the approach is demonstrated on a simulation system via modulation of inverter-based generation.

42 ENGINEERING↗

Alternative analysis of the MINERVE ZPR oscillation experiments

Delayed neutrons are of fundamental importance in the field of nuclear reactor dynamics and control. However, the precursor yield fraction for a given nuclear reactor are dependent on the properties of the reactor. Thus, in-pile experiments, such as oscillation experiments are conducted in order to measure those values. In this work, an alternative analysis of the piston oscillation experiments that have been conducted in the MINERVE reactor in 2013 is performed. A new method which evolves effective terms that cancel out undesired drifts of the flux during the experiments is presented. The evaluation of the uncertainty on the values of the response function is also presented. Moreover, the effective delayed neutron fraction β{sub eff} is evaluated and is compared to results in previous works. As the analysis has led to an estimation of β{sub eff} with a large uncertainty, it has been deduced that the oscillation experiments that have been conducted in MINERVE are not a reliable method of experimentation to determine the value of β{sub eff} in the reactor and that the noise experiments are better suited for that purpose.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Data-Driven Adaptive Damping Controller for Wind Power Plants with Doubly-Fed Induction Generators: Preprint

This paper presents an adaptive damping controller for wind power plants in which the turbines are equipped with doubly-fed induction generators. The controller is designed to respond to an input control signal that is triggered according to the system operating conditions. A processing unit continuously estimates the electromechanical modes of oscillation based on real-time streaming data acquired from a phasor measurement unit that is strategically positioned on the grid. The decision to trigger (or not trigger) the control signal is automatic, based on the relative damping of the dominant mode. The modes are estimated using the dynamic mode decomposition algorithm with time-delay embedding. Numerical simulations performed on the two-area system demonstrate that the proposed controller enhances the rotor angle stability for both small-signal and large disturbances, and is adaptive to changing grid conditions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Idealized Simulations of the Tropical Climate and Variability in the Single Column Atmosphere Model (SCAM): Radiative-Convective Equilibrium

To explore the interactions among column processes in the Community Atmosphere Model (CAM), the single-column version of CAM (SCAM) is integrated for 1000 days in radiative-convective equilibrium (RCE) with tropical values of boundary conditions, spanning a parameter or configuration space of model physics versions (v5 vs. v6), vertical resolution (standard and 60 levels), sea surface temperature (SST), and some interpretation-driven experiments. The simulated time-mean climate is reasonable, near observations and RCE of a cyclic cloud-resolving model. Updraft detrainment in the deep convection scheme produces distinctive grid-scale structures in humidity and cloud, which also interact with radiative transfer processes. These grid artifacts average out in multi-column RCE results reported elsewhere, illustrating the nuts-and-bolts interpretability that SCAM adds to the hierarchy of model configurations. Multi-day oscillations of precipitation arise from descent of warm convection-capping layers starting near the tropopause, eventually reset by a burst of convective deepening. Experiments reveal how these oscillations depend critically on an internal parameter that controls the number of neutral buoyancy levels allowed for determining cloud top and computing dilute convective available potential energy in the deep convection scheme, and merely modified a little by disabling cloud-base radiation (heating of cloud base). This strong dependence of transient behavior in 1D on this parameter will be tested in the second part of this work, in which SCAM is coupled to a parameterized dynamics of two-dimensional, linearized gravity wave, and in the 3D simulations in future study.

Meteorology & Atmospheric Sciences↗

Electrical Systems of Pumped Storage Hydropower Plants: Electrical Generation, Machines, Power Electronics, and Power Systems

Adjustable-speed (AS) pumped storage hydropower (PSH) technology has the potential to become a large, consistent contributor to grid stability enabling higher penetrations of wind and solar energy on the future U.S. power system. AS-PSH has high-value characteristics, such as fast response to provide ancillary services to the grid, because it is a power converter interface with the grid (like battery storage), but at the same time it has the energy content large enough to supply both short-term (seconds-to-minutes) and long-term (minutes-to-hours) of energy needs, like more conventional power plants. However, designs must be optimized to lower the capital expenditure (CapEx) and to provide a high-quality grid interface capability (e.g. power quality, ancillary service provider, fault-tolerant or fault ride-through capability), which is a primary factor in the acceptance of AS-PSH into a utility’s generation mix. This CapEx will be greatly affected by the cost savings associated with the civil structure, turbine design, power electronics, control systems, or unique generator designs. A holistic design must be considered to get a full picture of the benefits of the technology proposed. The AS-PSH can be controlled to reduce the impact of transient disturbance on a power system and at the same time can be controlled to minimized subsequent component fatigue and potential oscillation modes within the plant, with the overall impact in reducing the operational expenditures (OpEx).Generating clean power to meet standards such as Institute of Electrical and Electronics Engineers (IEEE) 519 and International Electrotechnical Commission (IEC) 1000-3-2 will be a continuing challenge. For many technology developers, however, improved AS-PSH technologies will become a key component of generator-storage systems of the future given the prospects of increased performance and decreasing costs, and the ever-increasing penetration of renewables (e.g wind power and solar power).

13 HYDRO ENERGY↗