Search NASA⌕ Search

SEARCH · Search NASA

Results for “owner”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Benchmarking thermal energy storage cost for industrial process heat

Process heat accounts for roughly half of industrial energy demand, and currently 95% of process heat is derived from the combustion of natural gas, oil, and coal. Electrification of industrial heating could be an alternative, potentially expanding locations suitable for manufacturing; however, industrial facility owners may desire energy storage to stabilize energy costs. In this work, the economic benefits of pairing thermal storage with electrified process heat to reduce the average price paid for energy are analyzed. Cost savings focus on energy arbitrage, or leveraging flexible energy pricing schemes, alone. The cost of natural gas combustion across decades (2019-2060) is compared to the costs of electricity and thermal energy storage in four United States Independent System Operator (ISO) regions. Systems installed today may not yield positive net present value (NPV) compared to the use of natural gas. However, using estimated electricity prices, systems installed in 2030 using arbitrage alone could be profitable when compared to natural gas in some regions of the U.S. Furthermore, if capital expenditures could be reduced by 50% for sensible thermal storage systems by 2030, profitable systems are found across all regions. This implies that electrification of industrial process heat, when paired with inexpensive thermal energy storage systems, could be less expensive than brownfield natural gas systems, using arbitrage as the only source of revenue and without a dependency on any future policy drivers such as pricing externalities that could further incentivize the electrification of industrial process heat.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Regional difference and related cooling electricity savings of air pollutant affected natural ventilation in commercial buildings across the US

Maintaining indoor air pollutants under acceptable levels is significant to protect occupants from exposure to excessive air pollutants in natural ventilation. In this paper, using the representative air pollutant concentration data, we present the natural ventilation usability with associated cooling energy saving potentials in different location settings (urban and city center, suburban and rural) of the US under the influence of local weather conditions and major outdoor air pollutants, i.e. PM2.5, PM10 and ozone. It is found that the impacts of air pollutants on natural ventilation are usually higher in urban/suburban areas than rural areas (up to 25% difference) with the PM2.5 being the most significant outdoor air pollutant affecting natural ventilation usage. Furthermore, ozone could become increasingly influential on natural ventilation as moving from urban to suburban/rural areas. As to the cooling energy saving considering the impacts of outdoor air pollutants, natural ventilation is estimated to save approximately 10%–40% cooling energy (800–2600 kWh per small commercial building) annually in different location settings of investigated areas across the US. The following economic analysis demonstrates that these electricity savings lead to approximately 80–540 dollars annual savings of building operation cost per building. If the time of use rate is adopted, these cost savings could further increase by approximately 20% (Los Angeles) to more than 50% (Albuquerque) depending on different rate structures, which further demonstrates the potential of adopting natural ventilation as a sustainability measurement with benefits for building owners without compromising occupants health.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The economic impacts of carbon emission trading scheme on building retrofits: A case study with U.S. medium office buildings

As a popular emission reduction tool, the carbon emission trading scheme (ETS) can potentially add an economic incentive for building owners to retrofit buildings in addition to the cost savings in energy. However, the additional economic benefits of building retrofits brought by ETS has not been quantitively investigated yet. Here, in order to fill this gap, this study proposed a systematic economic evaluation method to investigate the economic impacts of ETS on building retrofits. The reduction of the payback period and the increase of the return on investment are adopted as evaluation metrics. Using medium office buildings as an example, this study predicted the economic impacts of ETS on building retrofits at four locations in the U.S., and three different carbon prices were investigated. The results show that carbon prices have significant economic impacts on building retrofits. With the relatively low forecasted time-variant carbon prices (around 10 USD per ton), the economic impacts of ETS on building retrofits are small. When carbon prices increase, the impacts of ETS would be up to 25% for 50 USD per ton (current prices in European Union) and 51% for 100 USD per ton. Furthermore, locations with more fossil energy have higher relative changes in the payback period and ROI but are more sensitive to carbon prices.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Ten questions on future and extreme weather data for building simulation and analysis in a changing climate

Weather plays a significant role in building operations as it directly influences HVAC loads and in turn the building energy and thermal performance. In a changing climate, future trends and extreme weather events become critical concerns in the global building decarbonization and clean energy transition. This paper aims to address ten key questions concerning extreme and future weather data for building applications, and more importantly to identify research gaps and guide the curation and selection of future and extreme weather data for use in building performance simulation and assessment. The paper intends to inform architects and engineers, operators, owners, policy makers, and other stakeholders on considering the impacts of future and extreme weather data and adopting strategies for selecting and applying this data in various use cases related to building design, operation, and retrofit for energy efficiency, electrification, and climate resilience.

Yan, Da↗

Alkali-silica reaction expansion model for confined concrete with stress-dependency and casting direction anisotropy

Alkali-silica reaction (ASR) is a deleterious chemical reaction between alkali hydroxyl ions and types of silica found in some aggregates of concrete. Owners and regulators of nuclear power plants aim to ensure the safety of the concrete structures with optimal maintenance strategies. A new model was developed for predicting the expansion of concrete structures affected by alkali-silica reaction. The model includes a novel combination of existing models as an alkali-silica reaction advancement model, a casting direction anisotropic expansion model, a stress-dependent anisotropic expansion model, and a material property evolution model dependent on the degree of ASR expansion. The model parameters were calibrated based on existing literature data and data generated by previous efforts of this study. The calibrated model was then validated with the experiments carried out in previous efforts of this study. The model was shown to accurately predict the ASR-expansion of large-scale reinforced concrete specimens with confinement.

36 MATERIALS SCIENCE↗

Advances in building data management for building performance standards using the SEED platform

Reducing energy consumption and greenhouse gas emissions in the built environment is a critical step in achieving emission goals to mitigate climate change impacts. Local, federal, and international jurisdictions are deploying several methods to reduce energy and emissions such as voluntary and mandatory benchmarking and building performance standards, requiring building owners to reach energy and emission targets. Jurisdictions leveraging benchmarking and building performance standards require knowledge of the buildings covered; which is a large task due to staffing constraints, limited information on building characteristics and tax parcel data, and the need for advanced data management techniques to align datasets. This paper describes an open-source platform's recent advances to create consistent taxonomies, identify erroneous data, enable auditability, and track building performance. The paper concludes with two use cases on how the platform has been used by jurisdictions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Facets of hydro power and future trends in a Nordic Context

Hydropower technologies bolster high penetration of variable renewable energies (VREs) in the net zero emissions scenarios. Nevertheless, there are various challenges to meeting the ambitious goal, such as stability, reliability, resiliency, security, lack of reactive power, voltage support and inertia, large-scale storage deployment and coordination, interconnectedness, demand-side response, higher thermal cycles with increased start/stops, and inadequate Levelized Cost of Energy (LCOE) for system-wise VRE integration and profitability. This survey conducts a bottom-up analysis to unveil the opportunities to utilize hydropower facilities and disentangle the nested problem for intertwining design features, control algorithms, operation, optimization approaches, incentives, services, and market mechanisms using a three-pillar framework perspective: grid owners, power producers, and machine designers. The survey identified emerging trends in real-time and capacity markets, flexible power systems, and enhanced grid capabilities, including advanced voltage support and updated grid codes. These developments present significant opportunities for hydropower, such as achieving super-flexibility through hybridization, expanded reactive power capabilities, and advanced operational modes like a synchronous condenser and power adequator functionalities. These opportunities require novel design philosophies — including new winding, stator, and rotor configurations, optimized ventilation, and active cooling systems — to enhance performance under stressed grid and climate conditions. Finally, integrating climate and energy models for multi-basin optimization with finer spatial and temporal granularity enhances the planning accuracy for water management of hydropower while addressing environmental challenges. The review delivers helpful prospective suggestions and tools that would serve researchers, power engineers, and stakeholders in making decisions about hydropower technologies and services in 2050 and beyond.

13 HYDRO ENERGY↗

How Do Electricity Pricing Programs Impact the Selection of Energy Efficiency Measures? - A Case Study with U.S. Medium Office Buildings

Building owners usually select energy efficiency measures (EEMs) by referring to return on investment (ROI). Current studies tend to apply static energy price to estimate ROI. However, more and more buildings are adopting dynamic electricity pricing programs. To understand how electricity pricing programs impact the selection of EEMs, this paper presents an analysis of the ROIs of EEMs under different pricing programs using U.S. medium office buildings as an example. Eight EEMs in four typical cities are selected as case studies. Considering five electricity pricing programs scenarios (one static program and four dynamic programs), EEMs are selected based on their ROIs. The main findings are: (1) The ROIs of EEMs change under different pricing programs. (2) In Honolulu, Buffalo, and Denver, replacing interior fixtures with higher-efficiency fixtures has a significantly higher ROI than the rest EEMs under all five pricing programs. However, the ROI of this EEM in Honolulu ranges from 28% to 47% for different pricing programs. (3) Similarly, in Fairbanks, replace heating coil with higher-efficiency coil produce higher ROI than the rest under all five pricing programs. (4) For other EEMs, their ROI rankings vary according to electricity pricing programs.

demand response↗

MPC solution for optimal load shifting for buildings with ON/OFF staged packaged units: Experimental demonstration, and lessons learned

Small and medium-sized commercial buildings (SMCB) are significant demand response resources, and it is important to develop grid-responsive control algorithms that exploit those resources and create financial benefits for building owners and HVAC service providers. Furthermore, unlike large-sized commercial buildings, there is an opportunity to have universally applicable control solutions for many SMCBs since those buildings have a consistent HVAC system configuration: SMCBs are commonly served by multiple-staged air conditioning units controlled by their own thermostats. Despite the demand response potential and scalability, however, very few control solutions are available for SMCBs. Typical model predictive control (MPC) and heuristic control approaches for cooling load shifting that lower thermostat setpoints before an electric price jump are suitable mainly for large-sized commercial buildings where a continuous capacity modulation is possible, e.g., via dampers in variable air volume terminal units. However, those approaches can cause undesired, high peaks for SMCBs due to the nature of ON/OFF unit staging and narrow thermostat deadbands. This could discourage the use of advanced grid-responsive controls for SMCBs due to the concern of high demand charges, and has to be resolved. This paper presents a MPC solution that overcomes this challenge. It has a hierarchical MPC structure where an upper level MPC is responsible for electrical load shifting in response to an electric price signal while a lower level MPC is responsible for coordinating compressor stages to eliminate unnecessary peaks and follows the setpoints determined by the upper level MPC. In this work, two one-month, comprehensive laboratory tests have been carried out to demonstrate load shifting and cost savings for the algorithm. Interesting trade-offs between energy efficiency and load flexibility were observed and are discussed, and lessons learned for applying MPCs for SMCBs are also presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Real time side-by-side experimental validation of energy and comfort performance of a zero net energy retrofit package for small commercial buildings

Making buildings zero-net energy (ZNE) is one of the major strategies for achieving carbon emission reduction goals. For this strategy to be successful, it entails a very significant reduction in energy use – 50% or more. In small commercial buildings, however, owners and building management teams usually have limited resources for identifying, analyzing, and procuring appropriate retrofit measures for reducing such use. An approach to overcome this limitation is the development of bundles of energy efficiency measures that can be presented to building owners/operators as a comprehensive package. The research presented in this paper focuses on an experimental evaluation of the impacts of a retrofit package developed for small office buildings in California. Performing this evaluation in a full-scale whole-building integrated systems test facility allowed a side-by-side evaluation in real time, against a reference case, of the impact of the retrofit package not only on energy use but also on visual and thermal comfort. Here, the retrofit package evaluated is comprised of a combination of HVAC, lighting (including daylighting), and plug load measures. The evaluation occurred at different times of the year in order to account for seasonal variations in environmental conditions, including solar angles and weather. The experimental facility allowed testing for two different façade orientations: south and west. Results show that the proposed ZNE retrofit package can save significant amounts of energy for small commercial buildings. During cooling-prevalent periods, total energy savings were 65% for south orientation and 68% for west orientation; during heating-prevalent periods total energy savings were 22% for south orientation and 25% for west orientation. Measurements indicate that the ZNE retrofit package resulted in small but not very significant changes in comfort levels for building occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

On data-driven energy flexibility quantification: A framework and case study

Building energy flexibility is an important resource for a sustainable and resilient power grid, and an important measure to reduce utility costs for building owners. Quantifying energy flexibility for existing buildings can provide critical insights in optimizing their operation. Data-driven methods for building energy modeling and analytics are gaining popularity due to the increasingly available sensor and meter infrastructure, affordable computational resources, and advanced modeling algorithms. However, their application in quantifying the energy flexibility of real buildings is still limited due to the heterogeneous data types and limited data availability. Here, this study proposes a framework for building-level data-driven energy flexibility quantification that considers different levels of data availability and use cases. Two case studies with real building data collected at different scales were conducted to demonstrate the proposed framework for different purposes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An open control sequence specification to scale building demand flexibility via analytics software

For over two decades, researchers and practitioners have showcased the ability of large commercial buildings to provide grid services by shedding or shifting load. Various utility demand response (DR) and virtual power plant (VPP) programs throughout the United States are presently utilizing these demand-side resources. However, growth of these programs have been limited, in part due to the high cost necessary to integrate the DR control strategies into the building automation system (BAS). Implementing these strategies involves adjusting control sequences, necessitating dozens of hours of customized programming per building, limiting their adoption to large organizations and progressive owners. Recent efforts by researchers and industry have demonstrated the capability of energy management and information systems (EMIS), originally designed for fault detection and diagnostics, to interface with existing BAS and perform supervisory control to optimize building operations. While these approaches are quickly being adopted by industry, demand flexibility (DF) control strategies remain limited in product offerings. One of the challenges is the lack of documented best-practice DF sequences, despite the rich literature on field implementations. This paper develops a new open-specification for a zone-based temperature adjustment shed strategy for commercial building HVAC systems, describing the specification’s implementation in two EMIS tools in both experimental and field settings. Both implementations successfully reduced electric load by at least 40% on average during the called event, while maintaining temperature limits. This study’s detailed process from specification to deployment shows the potential for scalability as well as highlights challenges related to integration with heterogeneous BAS products.

Granderson, Jessica↗

Ice storage model-predictive control in an office building with PV: scenario, error and sensitivity analysis

Thermal energy storage (TES) can enable more building-sited renewable electricity generation and lower utility bill costs for buildings owners and occupants, especially when there are high demand and variable time-of-use (TOU) charges. A model predictive control (MPC) strategy can offer additional savings over a schedule-based control with added complexity and reliance on forecasts. Here, this study examines savings for medium office buildings with chiller plants in three locations with building-installed solar photovoltaics (PV) to understand the impact of MPC. Control setpoints are fixed by a schedule-based control or optimized by nonlinear MPC. These control setpoints are actuated within EnergyPlus building models to simulate the utility cost of the chiller plant. NLP solutions can be unstable or unrealistic, but our results show that by regularizing the NLP, the solutions can be reasonably followed by the building model. MPC models make simplifications that lead to errors once the controller is participating in and changing the operation of the building. These errors average 9 % across the cases, showing that the most important parts of the system are represented. The no-thermal load costs are computed to show that the optimization can in some cases achieve both the minimum TOU and minimum monthly demand costs by demand management while reducing TOU energy costs by energy arbitrage. The MPC saves 35–66 % in the annual chiller plant operating costs, which is an additional savings above the schedule by 1–33 %. PV and TES are complementary and mostly independent, but a load with PV often results in better performance for the schedule. Our case study and sensitivity analysis show the importance of modeling and optimization for complex rates, but also the circumstances wherein a simpler strategy achieves the same performance with less potential for error.

14 SOLAR ENERGY↗

Evaluating the current perceived cost of ownership for buses and trucks in China

Decarbonizing commercial vehicles, including buses, trucks, and special purpose vehicles, is essential for China to achieve its carbon neutrality target by 2060. However, understanding the adoption barriers of alternative fuel technologies for commercial vehicles has largely been limited to the total cost of ownership approach that mainly considers tangible costs. Additionally, this study proposes a perceived cost of ownership (PCO) model, which monetizes both tangible and implicit costs, including charging annoyance for buses and trucks by size and classification under different use scenarios. In the case study for China's current bus and truck market, the PCO of alternative fuel technologies, such as battery electric vehicles (BEVs) and fuel cell electric vehicles (FCEVs) are 27%–129% and 31%–86% higher than the most economically competitive powertrains – the compressed natural/liquefied petroleum gas technology and hybrid electric technology. BEVs could be cost-effective in the mini/midsize bus segment or in the daily short-distance driving scenario, and FCEVs could firstly be deployed in cities with a low hydrogen price. Though the implicit costs caused by range anxiety and charging annoyance account for at least 27% of BEV's PCO, making BEV uncompetitive, the battery swapping technique could reduce the implicit cost and overall cash outflow for BEV owners.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Opportunities for installed combined heat and power (CHP) to increase grid flexibility in the U.S.

Increasing use of renewable energy requires sufficient grid flexibility to address uncertainty and variability in electricity generation. Previous studies suggest that combined heat and power (CHP) systems may support grid flexibility but they do not consider operating hours. In this paper, we used CHP operating data and determined annual and monthly availability of the installed CHP capacity from various sectors (e.g., utility, independent power producer, commercial, and industrial) in all seven U.S. independent system operators (ISOs) and regional transmission organizations (RTOs). Also, we estimated hourly CHP availability installed in five facility types (i.e., hospitals, universities, hotels, offices, and manufacturing) in the state of New York. The results show that regardless of ISO/RTO, sector, or season, more than 40% of the installed CHP capacity (0.7–8.7 GW) was not fully utilized in 2019; the results are similar for 2018. This available CHP capacity accounted for up to 9% of the ISO/RTO's peak electric demand, which may yield cost savings up to $16 billion by avoiding installation costs of new natural gas combustion or combined-cycle turbines. To exploit the available CHP capacity to enhance grid flexibility, we recommend different policy implications including flexible contract lengths between CHP owners and grid operators, improved market designs, and simplified interconnection standards.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Shedding light on the economic costs of long-duration power outages: A review of resilience assessment methods and strategies

Here this paper provides a literature review of methods and modeling techniques to estimate the cost of power system outages, along with the value of outage mitigation or system resilience. Regulators, policymakers, and infrastructure owners have a growing need to understand the methods for estimating the benefits of resilience improvements of electric infrastructure against natural and man-made disasters. There is a broad literature that estimates the cost of short-duration outages and a small but developing literature on estimating the cost of long-duration outages. This article reviews the models used to estimate the cost of outages and discusses their relative strengths. Additionally, this paper identifies key questions from stakeholders regarding resilience investment and maps them to the relevant models that would help answer them. We include recommendations for future work to include recent advances in regional economic modeling that can estimate region and demographic-specific costs and the distributional consequences of potential resilience projects.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Novel artificial neural network model for instantaneous power losses and operational efficiency mapping of MW-scale vanadium redox flow battery for improved technoeconomic analysis

A novel data-driven, machine-learning-based method for modeling the instantaneous power losses of a distribution-sited 2 MW/8MWh vanadium redox flow battery (VRFB), a grid-scale electrochemical storage technology, is introduced and compared against benchmark empirical modeling approaches, including symmetric and asymmetric models, as well as a recent convex hull modeling approach. The novel loss modeling method introduces several advantages over the benchmark models and over simplistic efficiency estimates, the most significant of which is that the model can accurately reflect the stepwise and non-linear parasitic losses associated with the duty cycles of mechanical auxiliary systems like pump motor drives and blower fans. Residuals of the models are compared; the proposed data driven model features significantly improved accuracy over the benchmark models. The model's coefficient of determination is also improved relative to that of the benchmark models. Furthermore, a novel method for visualization of operational efficiency of the grid-scale storage technology is introduced. To demonstrate the benefits of the novel data-driven method for modeling the VRFB, the benchmark models and the proposed models are embedded into an Open DSS distribution network model to study two applications of the grid-scale electrical storage system: load leveling for grid support and energy arbitrage. This article demonstrates that the accuracy of the instantaneous power loss model significantly impacts the understanding of the state of charge of the VRFB. In turn, the accuracy of the efficiency modeling of the VRFB impacts the understanding of the potential economic value and technical benefits to the distribution network operators. In conclusion, the presented power loss modeling approach is, therefore, highly relevant for utility-stakeholders, battery asset owners, system engineers, system designers, and financial planners interested in evaluating or optimizing the operation of grid-scale VRFBs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Aerial drone fleet deployment optimization with endogenous battery replacements for direct delivery of time-sensitive products

Aerial drones offer a distinct potential to reduce the delivery time and energy consumption for the delivery of time-sensitive and small products. However, there is still a need in the relevant industry to understand the performance of drone-based delivery under different business needs and drone operating conditions. We studied a drone deployment optimization problem for direct delivery of time-sensitive products with release dates to customers maintaining a specified time window. This paper presents a new mixed-integer programming model, new valid inequalities, a new greedy heuristic algorithm, and a Genetic algorithm to help business owners optimally schedule and route their drone fleet minimizing the required fleet size, the required number of additional batteries, and total energy consumption. A realistic feature of the optimization method is that instead of replacing the drone battery after each return to the depot, it keeps track of the remaining energy in the drone battery and decides on battery replacements accounting for the drone routing and the user-specified minimum required battery energy. Numerical results based on real data from drone flight tests and prepared food delivery industry provide insights into the effect of different practical drone operating parameters on the required fleet size, the required number of battery replacements, and energy consumption. Here, results demonstrate that the proposed heuristic algorithm substantially outperforms the accelerated CPLEX in runtime while sacrificing the solution quality by a small amount. Additionally, results show that using a mixed fleet of hexacopter and quadcopter drones reduces the total energy consumption by 48.52% compared to using a homogeneous fleet of only hexacopters.

Drone energy consumption↗