Search NASA⌕ Search

SEARCH · Search NASA

Results for “passive detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Toward ultrafast, ultra-stable imaging arrays: Superlattice doping to enhance the performance of backside-illuminated 3D-hybridized silicon photodetectors

In this paper, the authors report the latest results on their development of superlattice-doped, thinned, backside-illuminated (BSI), 3D-integrated photodiode detectors—a step toward their ultimate goal of demonstrating ultrafast, ultrastable CMOS imaging arrays. As with most silicon-based photodetectors, backside-illumination and backside surface passivation are keys to achieve the highest performance capability. The two-dimensional (2D) doping technique developed at the Jet Propulsion Laboratory (JPL) has proved to result in a highly efficient, highly stable detector response when combined with a variety of detectors. Here, JPL's 2D-doping has been combined with Sandia's BSI photodetectors hybridized with custom fanout wafer via copper Direct Bond Interconnect (DBI®), a technology that is rapidly becoming industry standard for BSI CMOS imaging arrays. The prototype detectors were packaged and evaluated with respect to their response to low energy electrons. The authors find that the responsivity of 2D-doped BSI detectors is higher than devices prepared using other surface passivation techniques (i.e., ion implantation). The success of the work described herein verifies that the 2D-doping processes previously developed for Sandia's frontside-illuminated photodetectors are generally applicable to BSI detectors and demonstrates for the first time that JPL's 2D-doping process is compatible with the Cu-DBI® technology.

Jewell, April D.↗

A passive chevron replicator

Instrument design provides replicate function between device storage area and guardrail detector in order that nondestructive read-out of memory can be achieved. Use of guardrail detectors in magnetic domain (bubble) circuits is proposed method of increasing detector signal output by increasing detector size without dedicating an excessive amount of device chip area to detector portion.

Oeffinger, T. R.↗

New segmented target for studies of neutron unbound systems

The study of neutron-unbound systems using invariant mass spectroscopy is often performed using low-intensity radioactive ion beams. Low reaction yields can be countered by using thick targets but at the expense of larger uncertainties in the reconstructed invariant mass. In this work, we present a new segmented target designed to address this trade-off. It is composed of three mm thick passive beryllium targets interleaved between four thick position sensitive silicon detectors. In the first experiment to use this new system the half-life of two-neutron unbound was measured to be (stat) (syst) ps, which agrees with a previous measurement made by the MoNA Collaboration.

47 OTHER INSTRUMENTATION↗

Low-frequency attenuator circuit

Circuit uses only single operational amplifier and few passive components to remove background noise from miniature "wristwatch" pulse detector. It can be applied to other systems where background noise is slowly varying, such as ultrasonics, strain-gage sensors, and accelerometers.

Cash, W. H., Jr.↗

LDEF radiation measurements: preliminary results

The Long Duration Exposure Facility (LDEF), retrieved by the Space Shuttle mission STS-32 after nearly 6 yr in orbit, is the focus of a broad-based study of the radiation environment in low Earth orbit (LEO) and its effects on materials. A combination of passive techniques has been used to study this environment via detectors which were contained in experiments aboard the LDEF spacecraft and through analysis of induced radioactivities. Preliminary results for absorbed dose measurements and for induced activities in various materials are presented. A number of effects have been observed which reflect the anisotropy of the charged particle flux in low Earth orbit. Quantitative results from these measurements should provide an accurate means of confirming environmental flux models and techniques for predicting radiation encountered in future LEO missions, particularly those of extended duration.

NASA Discipline Number 00-00↗

Instrumentation for investigation of the depth-dose distribution by the Liulin-5 instrument of a human phantom on the Russian segment of ISS for estimation of the radiation risk during long term space flights

Described is the Liulin-5 experiment and instrumentation, developed for investigation of the space radiation doses depth distribution in a human phantom on the Russian Segment of the International Space Station (ISS). Liulin-5 experiment is a part of the international project MATROSHKA-R on ISS. The experiment MATROSHKA-R is aimed to study the depth dose distribution at the sites of critical organs of the human body, using models of human body-anthropomorphic and spherical tissue-equivalent phantoms. The aim of Liulin-5 experiment is long term (4-5 years) investigation of the radiation environment dynamics inside the spherical tissue-equivalent phantom, mounted in different places of the Russian Segment of ISS. Energy deposition spectra, linear energy transfer spectra, flux and dose rates for protons and the biologically-relevant heavy ion components of the galactic cosmic radiation will be measured simultaneously with near real time resolution at different depths of the phantom by a telescope of silicon detectors. Data obtained together with data from other active and passive dosimeters will be used to estimate the radiation risk to the crewmembers, verify the models of radiation environment in low Earth orbit, validate body transport model and correlate organ level dose to skin dose. Presented are the test results of the prototype unit. The spherical phantom will be flown on the ISS in 2004 year and Liulin-5 experiment is planned for 2005 year. c2004 COSPAR. Published by Elsevier Ltd. All rights reserved.

Cosmic Radiation↗

The Moon Mineralogy (M3) Imaging Spectrometer: Early Assessment of the Spectral, Radiometric, Spatial and Uniformity Properties

The Moon Mineralogy Mapper's (M3) is a high uniformity and high signal-to-noise ratio NASA imaging spectrometer that is a guest instrument on the Indian Chandrayaan-1 Mission to the Moon. The laboratory measured spectral, radiometric, spatial, and uniformity characteristics of the M3 instrument are given. The M3 imaging spectrometer takes advantage of a suite of critical enabling capabilities to achieve its measurement requirement with a mass of 8 kg, power usage of 15 W, and volume of 25X18X12 cm. The M3 detector and spectrometer are cooled by a multi-stage passive cooler. This paper presents early M3 performance assessment results.

Green, Robert O.↗

Complex Signal Kurtosis and Independent Component Analysis for Wideband Radio Frequency Interference Detection

Radio-frequency interference (RFI) has negatively implicated scientific measurements across a wide variation passive remote sensing satellites. This has been observed in the L-band radiometers SMOS, Aquarius and more recently, SMAP [1, 2]. RFI has also been observed at higher frequencies such as K band [3]. Improvements in technology have allowed wider bandwidth digital back ends for passive microwave radiometry. A complex signal kurtosis radio frequency interference detector was developed to help identify corrupted measurements [4]. This work explores the use of ICA (Independent Component Analysis) as a blind source separation technique to pre-process radiometric signals for use with the previously developed real and complex signal kurtosis detectors.

microwave↗

RFI Detection and Mitigation using Independent Component Analysis as a Pre-Processor

Radio-frequency interference (RFI) has negatively impacted scientific measurements of passive remote sensing satellites. This has been observed in the L-band radiometers Soil Moisture and Ocean Salinity (SMOS), Aquarius and more recently, Soil Moisture Active Passive (SMAP). RFI has also been observed at higher frequencies such as K band. Improvements in technology have allowed wider bandwidth digital back ends for passive microwave radiometry. A complex signal kurtosis radio frequency interference detector was developed to help identify corrupted measurements. This work explores the use of Independent Component Analysis (ICA) as a blind source separation (BSS) technique to pre-process radiometric signals for use with the previously developed real and complex signal kurtosis detectors.

independent component analysis↗

Design and Technical Study of Neutrino Detector Spacecraft

A neutrino detector is proposed to be developed for use on a space probe in close orbit of the Sun. The detector will also be protected from radiation by a tungsten shield Sun shade, active veto array and passive cosmic shielding. With the intensity of solar neutrinos substantially greater in a close solar orbit than on the Earth only a small 250 kg detector is needed. It is expected that this detector and space probe studying the core of the Sun, its nuclear furnace and particle physics basic properties will bring new knowledge beyond what is currently possible for Earth bound solar neutrino detectors.

Design and Technical Study↗

The Modeled Performance of the ORNL Matched Filter Detector for Seismic Signatures of Multi-Axle Tractor Trailers

The MINOS program seeks methods to passively monitor the transfer of special materials, which are reproducible and quantitatively defensible. To date, we have demonstrated that short-period seismometers deployed near vehicle tracks can detect and monitor signatures of multi-axle tractor trailers impacting small road obstacles as means to detect and identify some transfer activities. In this report, we model the seismic velocity signal output from a tractor-trailer impacting a small obstacle (a template waveform) to parameterize a matched filter that identifies signals with similar shapes buried in noise, and that indicate repeating events (target waveforms). We then use this model to perform thousands of synthetic experiments, in which we apply our detector to identify noisy waveforms output from a similarly modeled vehicle data set; we process all data in the same manner as we process real data collected from the Oak Ridge National Laboratory (ORNL) seismic network. Our experiments, while limited, reveal that the matched filter shows a high discrimination capability, and at very low SNR values (at visibility thresholds). This means that template waveforms can match target waveforms that are sourced by models that share the same vehicle speed (target vehicles), and have a low probability of mis-identification. In particular, a matched filter designed to detect a five-axle tractor-trailer will reliably identify that target vehicle down to an SNR of 11.25 dB, and within ±0.1 km/hr, while successfully screening target vehicles with three axles.

42 ENGINEERING↗

Results and Lessons from MODIS Thermal Emissive Bands Calibration: Pre-launch to On-orbit

MODIS is a major instrument for the NASA EOS Terra (launched in December 1999) and Aqua (launched in May 2002) missions. It was designed and built to enhance and extend its heritage sensors' measurements and data records with applications covering a wide range of studies of the Earth's land, oceans, and atmosphere. Its 16 thermal emissive bands (TEB), each with 10 detectors, are located on the two cold focal plane assemblies (FPAs) controlled by a passive radiative cooler. Because of instrument design complexity and stringent calibration requirements, extensive calibration and characterization activities were conducted pre-launch by the sensor vendor for both Terra and Aqua MODIS. For TEB, these activities include characterization of detectors' noise and non-linearity and evaluation of their radiometric performance in thermal vacuum at difference instrument temperatures and FPA temperatures. In addition TEB system level response versus scan-angle (RVS) and relative spectral response (RSR) were characterized. MODIS TEB radiometric calibration transfer from pre-launch to on-orbit was performed using spectral bands' responses to the instrument on-board blackbody and a laboratory blackbody calibration source (BCS) traceable to NIST standards. This paper provides a summary of MODIS TEB pre-launch and on-orbit calibration and characterization activities, challenges, data analysis results, and lessons learned with focus on sensors' radiometric performance. A comparison between Terra and Aqua MODIS TEB performance is also presented. A similar summary for the reflective solar bands (RSB) is reported in a separate paper in these proceedings.

Xiong, X.↗

Study of meteoroid impact craters on various materials (AO 138-1). Attempt at dust debris collection with stacked detectors (AO 138-2)

Part of the Long Duration Exposure Facility (LDEF) tray allocated to French experiments, known as FRECOPA payload, was devoted to the study of dust particles. Two passive experiments were flown: one composed of a set of glass and metallic samples and one composed of multilayer thin foils detectors. In addition to these experiments, a broad variety of materials were exposed to the bombardment of microparticles and provide more data. Thick target experiment comprises selected metallic (Al, Au, Cu, W, Stainless Steel) 250 microns thick and glass surfaces 1.5 mm thick. Crater size distribution from these thick target experiments enable, with the aid of lab calibrations by solid particle accelerators, the evaluation of the incident microparticle flux in the near earth environment. The aim of the multiple foil penetration and collection experiment is primarily to study the feasibility of multilayer thin film detectors acting as energy sorters in order to collect micrometeoroids, if not in their original shape, at least as 'breakup' fragments suitable for chemical analysis. Foil thicknesses range from 0.75 to 5 microns of Al.

Mandeville, Jean Claude↗

Effect of space exposure of pyroelectric infrared detectors

Pyroelectric detectors are one of many different types of infrared radiation detectors. The pyroelectric detectors are of interest for long term space use because they do not require cooling during operation. Also, they can detect at very long wavelengths and they have a relatively flat spectral response. A disadvantage is that the radiation must be chopped in order to be detected by a pyroelectric detector. The objective was to determine the effects of launch and space exposure on the performance of commercially available pyroelectric detectors. The approach was to measure certain detector parameters before and after flight and try to determine the amount and cause of the degradation. The experiment was passive: no data was taken during flight. It is concluded that lithium-tantalate and strontium-barium-niobate are suitable materials for pyroelectric detectors for long term space applications.

Robertson, James B.↗

Apollo 15 surface science summary.

The Apollo 15 mission was the fourth manned lunar landing and the northernmost location yet visited. The landing site on the southeastern edge of the Imbrium Basin afforded the opportunity of studying several unique lunar features, the Apennine Mountains, Hadley Rille, and the Imbrium Basin fill. Detailed geological study of the data returned from the mission provided new insight into the structure and history of the Basin. A third Apollo Lunar Surface Experiment Package was deployed during the mission containing seven experiments: Passive Seismometer (PSE), Heat Flow (HFE), Surface Magnetometer (LSM), Suprathermal Ion Detector (SIDE), Cold Cathode Gauge (CCGE), Solar Wind Spectrometer (SWS), and a Dust Detector. We have been able to triangulate on the sources of moonquakes and to observe simultaneous nighttime and daytime changes in the moon's magnetic field, solar wind flux, and the neutral and ionized components of the moon's tenuous atmosphere.

Beattie, D. A.↗

Sealed position sensitive hard X-ray detector having large drift region for all sky camera with high angular resolution

A sealed position sensitive proportional counter filled with two atmospheres of 95% xenon and 5% methane, and containing a drift region of 24 atm cm, has operated in a stable manner for many months. The detector contains G-10 frames to support the anode and cathode wires. The detector was sealed successfully by a combination of vacuum baking the G-10 frames at 150 C for two weeks followed by assembly into the detector in an environment of dry nitrogen, and the use of passive internal getters. The counter is intended for use with a circumferential cylindrical collimator. Together they provide a very broad field of view detection system with the ability to locate cosmic hard X-ray and soft gamma ray sources to an angular precision of a minute of arc. A set of instruments based on this principle have been proposed for satellites to detect and precisely locate cosmic gamma ray bursts.

Gorenstein, P.↗

ISS and Space Shuttle Radiation Measurements at Solar Minimum

A summary of 2008-2011 ISS and Space Shuttle radiation dosimetry results for inside vehicle radiation monitoring in low-Earth orbit will be presented. Results include new data from ISS Expedition 22-25/20A radiation area monitors (RAM) and Shuttle Missions STS127-STS133 passive radiation dosimeters (PRD). ISS 20A radiation measurement locations included three Node 2 crew quarters locations at NOD2S5_CQ, NOD2P5_CQ and CQ-3 (Deck), as well as ESA Columbus, and JAXA Kibo locations. ISS 20A and STS127-STS133 missions were flown at 51.6 inclination with an altitude range of 330-350 km. The passive radiation results will be presented in terms of measured daily dose obtained using luminescence detectors (i.e., Al2O3:C, LiF:Mg,Ti and CaF2:Tm). In addition, preliminary results from the DOSIS 2 Project, in collaboration with the German Space Agency (DLR) will be presented. SRAG s participation to the DOSIS 2 exposure on ISS (11/16/2009-05/26/2010) involved passive radiation measurements at 10 different shielding locations inside the ESA Columbus Module.

Gaza, Ramona↗

Passive and active neutron signatures of 233 U for nondestructive assay

The thorium fuel cycle is emerging as an attractive alternative to conventional nuclear fuel cycles, as it does not require the enrichment of uranium for long-term sustainability. The operating principle of this fuel cycle is the irradiation of 232 Th to produce 233 U, which is fissile and sustains the fission chain reaction. 233 U poses unique challenges for nuclear safeguards, as it is associated with a uniquely extreme γ-ray environment from 232 U contamination, which limits the feasibility of the γ-ray-based assay, as well as more conservative accountability requirements than for 235 U set by the International Atomic Energy Agency. Consequently, instrumentation used for safeguarding 235 U in traditional fuel cycles may be inapplicable. It is essential that the nondestructive signatures of 233 U be characterized so that nuclear safeguards can be applied to thorium fuel-cycle facilities as they come online. In this work, a set of 233 U 3 O 8 plates, containing 984 g 233 U, was measured at the National Criticality Experiments Research Center. A high-pressure 4 He gaseous scintillation detector, which is insensitive to γ-rays, was used to perform a passive fast neutron spectral signature measurement of 233 U 3 O 8 , and was used in conjunction with a pulsed deuterium-tritium neutron generator to demonstrate the differential die-away signature of this material. Furthermore, an array of 3 He detectors was used in conjunction with the same neutron generator to measure the delayed neutron time profile of 233 U, which is unique to this nuclide. These measurements provide a benchmark for future nondestructive assay instrumentation development, and demonstrate a set of key neutron signatures to be leveraged for nuclear safeguards in the thorium fuel cycle.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗